893 resultados para Muscular Force


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Falls are a major concern in the elderly population with chronic joint disease. To compare muscular function and functional mobility among older women with knee osteoarthritis with and without a history of falls, 15 elderly women with a history of falls (74.20 ± 4.46 years) and 15 without a history of falls (71.73 ± 4.73 years) were studied. Muscular function, at the angular speed of 60, 120, and 180º/s, was evaluated using the Biodex Isokinetic Dynamometer. The sit-to-stand task was performed using the Balance Master System and the Timed Up and Go test was used to determine functional mobility. After collection of these data, the history of falls was investigated. A statistically significant difference was detected in the time taken to transfer the center of gravity during the sit-to-stand test (means ± SD; non-fallers: 0.35 ± 0.16 s; fallers: 0.55 ± 0.32 s; P = 0.049, Student t-test) and in the Timed Up and Go test (medians; non-fallers: 10.08 s; fallers: 11.59 s; P = 0.038, Mann-Whitney U-test). The results indicated that elderly osteoarthritic women with a history of falls presented altered functional mobility and needed more time to transfer the center of gravity in the sit-to-stand test. It is important to implement strategies to guarantee a better functional performance of elderly patients to reduce fall risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to evaluate breathing pattern, thoracoabdominal motion and muscular activity during three breathing exercises: diaphragmatic breathing (DB), flow-oriented (Triflo II) incentive spirometry and volume-oriented (Voldyne) incentive spirometry. Seventeen healthy subjects (12 females, 5 males) aged 23 ± 5 years (mean ± SD) were studied. Calibrated respiratory inductive plethysmography was used to measure the following variables during rest (baseline) and breathing exercises: tidal volume (Vt), respiratory frequency (f), rib cage contribution to Vt (RC/Vt), inspiratory duty cycle (Ti/Ttot), and phase angle (PhAng). Sternocleidomastoid muscle activity was assessed by surface electromyography. Statistical analysis was performed by ANOVA and Tukey or Friedman and Wilcoxon tests, with the level of significance set at P < 0.05. Comparisons between baseline and breathing exercise periods showed a significant increase of Vt and PhAng during all exercises, a significant decrease of f during DB and Voldyne, a significant increase of Ti/Ttot during Voldyne, and no significant difference in RC/Vt. Comparisons among exercises revealed higher f and sternocleidomastoid activity during Triflo II (P < 0.05) with respect to DB and Voldyne, without a significant difference in Vt, Ti/Ttot, PhAng, or RC/Vt. Exercises changed the breathing pattern and increased PhAng, a variable of thoracoabdominal asynchrony, compared to baseline. The only difference between DB and Voldyne was a significant increase of Ti/Ttot compared to baseline. Triflo II was associated with higher f values and electromyographic activity of the sternocleidomastoid. In conclusion, DB and Voldyne showed similar results while Triflo II showed disadvantages compared to the other breathing exercises.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis properties and influence of modification techniques of porous silicon were studied by Atomic Force Microscope (AFM). This device permits to visualize the surface topography and to study properties of the samples on atomic scale, which was necessary for recent investigation. Samples of porous silicon were obtained by electrochemical etching. Nickel particles were deposited by two methods: electrochemical deposition and extracting from NiCl2 ethanol solution. Sample growth was conducted in Saint-Petersburg State Electrotechnical University, LETI. Kelvin probe force microscopy (KPFM) and Magnetic force microscopy (MFM) were utilized for detailed information about surface properties of the samples. Measurements showed the difference in morphology correlating with initial growth conditions. Submicron size particles were clearly visible on surfaces of the treated samples. Although their nature was not clarified due to limitations of AFM technique. It is expected that surfaces were covered by nanometer scale Ni particles, which can be verified by implication of RAMAN device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anesthetics can affect the structure and biological function of tissues and systems differentially. The aim of the present study was to compare three injectable anesthetics generally used in experiments with animals in terms of the degree of hemolysis and glycogenolysis occurring after profound anesthesia. Twenty-four male Wistar rats (330-440 g) were divided into three groups (N = 8): chloral hydrate (CH), ketamine + xylazine (KX), Zoletil 50® (zolazepam and tiletamine) + xylazine (ZTX). After deep anesthesia, total blood was collected. The liver and white (WG) and red gastrocnemius (RG) muscles were also immediately removed. The degree of serum hemolysis was quantified on the basis of hemoglobin concentration (g/L). Hepatic and muscular glycogen concentrations (mmol/kg wet tissue) were quantified by the phenol-sulfuric method. The CH and KX groups exhibited serum hemolysis (4.0 ± 2.2 and 1.9 ± 0.9 g/L, respectively; P < 0.05) compared to the ZTX group, which presented none. Only KX induced elevated glycogenolysis (mmol/kg wet tissue) in the liver (86.9 ± 63.2) and in WG (18.7 ± 9.0) and RG (15.2 ± 7.2; P < 0.05). The CH and ZTX groups exhibited no glycogenolysis in the liver (164.4 ± 41.1 and 176.8 ± 54.4, respectively), WG (28.8 ± 4.4, 32.0 ± 6.5, respectively) or RG (29.0 ± 4.9; 25.3 ± 8.6, respectively). Our data indicate that ZTX seems to be an appropriate general anesthetic for studies that seek to simultaneously quantify the concentration of glycogen and serum biochemical markers without interferences. ZTX is reasonably priced, found easily at veterinary markets, quickly induces deep anesthesia, and presents a low mortality rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erythropoietin (EPO) has been well characterized as a renal glycoprotein hormone regulating red blood cell production by inhibiting apoptosis of erythrocyte progenitors in hematopoietic tissues. EPO exerts regulatory effects in cardiac and skeletal muscles. Duchenne muscular dystrophy is a lethal degenerative disorder of skeletal and cardiac muscle. In this study, we tested the possible therapeutic beneficial effect of recombinant EPO (rhEPO) in dystrophic muscles in mdx mice. Total strength was measured using a force transducer coupled to a computer. Gene expression for myostatin, transforming growth factor-β1 (TGF-β1), and tumor necrosis factor-α (TNF-α) was determined by quantitative real time polymerase chain reaction. Myostatin expression was significantly decreased in quadriceps from mdx mice treated with rhEPO (rhEPO=0.60±0.11, control=1.07±0.11). On the other hand, rhEPO had no significant effect on the expression of TGF-β1 (rhEPO=0.95±0.14, control=1.05±0.16) and TNF-α (rhEPO=0.73±0.20, control=1.01±0.09). These results may help to clarify some of the direct actions of EPO on skeletal muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the effects of intermittent passive manual stretching on various proteins involved in force transmission in skeletal muscle. Female Wistar weanling rats were randomly assigned to 5 groups: 2 control groups containing 21- and 30-day-old rats that received neither immobilization nor stretching, and 3 test groups that received 1) passive stretching over 3 days, 2) immobilization for 7 days and then passive stretching over 3 days, or 3) immobilization for 7 days. Maximal plantar flexion in the right hind limb was imposed, and the stretching protocol of 10 repetitions of 30 s stretches was applied. The soleus muscles were harvested and processed for HE and picrosirius staining; immunohistochemical analysis of collagen types I, III, IV, desmin, and vimentin; and immunofluorescence labeling of dystrophin and CD68. The numbers of desmin- and vimentin-positive cells were significantly decreased compared with those in the control following immobilization, regardless of whether stretching was applied (P<0.05). In addition, the semi-quantitative analysis showed that collagen type I was increased and type IV was decreased in the immobilized animals, regardless of whether the stretching protocol was applied. In conclusion, the largest changes in response to stretching were observed in muscles that had been previously immobilized, and the stretching protocol applied here did not mitigate the immobilization-induced muscle changes. Muscle disuse adversely affected several proteins involved in the transmission of forces between the intracellular and extracellular compartments. Thus, the 3-day rehabilitation period tested here did not provide sufficient time for the muscles to recover from the disuse maladaptations in animals undergoing postnatal development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contact force (CF) sensing technology allows real-time monitoring during catheter ablation for atrial fibrillation (AF). However, the effect of CF sensing technology on procedural parameters and clinical outcomes still needs clarification. Because of the inconsistent results thus far in this area, we performed a meta-analysis to determine whether CF sensing technology can improve procedural parameters and clinical outcomes for the treatment of AF. Studies examining the benefits of CF sensing technology were identified in English-language articles by searching the MEDLINE, Web of Science, and Cochrane Library databases (inception to May 2015). Ten randomized, controlled trials involving 1834 patients (1263 males, 571 females) were included in the meta-analysis (681 in the CF group, 1153 in the control group). Overall, the ablation time was significantly decreased by 7.34 min (95%CI=-12.21 to -2.46; P=0.003, Z test) in the CF group compared with the control group. CF sensing technology was associated with significantly improved freedom from AF after 12 months (OR=1.55, 95%CI=1.20 to 1.99; P=0.0007) and complications were significantly lower in the CF group than in the control group (OR=0.50, 95%CI=0.29 to 0.87; P=0.01). However, fluoroscopy time analysis showed no significantly decreased trend associated with CF-guided catheter ablation (weighted mean difference: -2.59; 95%CI=-9.06 to 3.88; P=0.43). The present meta-analysis shows improvement in ablation time and freedom from AF after 12 months in AF patients treated with CF-guided catheter ablation. However, CF-guided catheter ablation does not decrease fluoroscopy time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: A doença renal crônica associada ao tratamento hemodialítico pode apresentar uma diversidade de complicações músculo-esqueléticas, além de trazer repercussões à função pulmonar. OBJETIVO: Avaliar os efeitos do treinamento muscular inspiratório na força muscular inspiratória, função pulmonar e capacidade funcional em pacientes com insuficiência renal crônica submetidos à hemodiálise. MÉTODO: Ensaio clínico não controlado, composto por 15 indivíduos com diagnóstico médico de insuficiência renal crônica, submetidos à hemodiálise. Foram avaliados pressões inspiratória máxima (PImáx) e expiratória máxima (PEmáx) através da manovacuometria; função pulmonar pela espirometria e a capacidade funcional através da distância percorrida e consumo de oxigênio obtido no teste da caminhada dos seis minutos (TC6M). No período de oito semanas, foi aplicado o protocolo de treinamento muscular respiratório (TMI) durante a sessão de hemodiálise, com carga estabelecida de 40% da PImáx e uma frequência semanal de três dias alternados. RESULTADOS: Houve um aumento significativo na variável distância percorrida após o treinamento (455 ± 98 versus 558 ± 121; p = 0,003). Não foram encontradas diferenças estatísticas na comparação antes e após treinamento nas demais variáveis do estudo. CONCLUSÃO: O estudo não apresentou diferença estatística na força muscular respiratória, na função pulmonar e no consumo de oxigênio. Observou-se apenas um aumento na distância do TC6M.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZrO2 nanocomposites were investigated considering their perspective application in hygroelectric power elements. Scanning probe microscopy (SPM) techniques allowed to visualize the surface topography and electrical properties. In this work was compared spacial charge behaviour of sample in humid and dry air conditions. Also different SPM modes were compared. Kelvin probe force microscopy (KPFM) was applied to characterize the spacial charge distribution on surface of the sample. Measurements showed, that trapped charge is not dissipated and can be manipulated with low voltages. Humidity influence on the electric potential of the sample was shown.