874 resultados para Medical rationalities
Resumo:
This paper presents work in progress, to develop an efficient and economic way to directly produce Technetium 99metastable (99mTc) using low-energy cyclotrons. Its importance is well established and relates with the increased global trouble in delivering 99mTc to Nuclear Medicine Departments relying on this radioisotope. Since the present delivery strategy has clearly demonstrated its intrinsic limits, our group decided to follow a distinct approach that uses the broad distribution of the low energy cyclotrons and the accessibility of Molybdenum 100 (100Mo) as the Target material. This is indeed an important issue to consider, since the system here presented, named CYCLOTECH, it is not based on the use of Highly Enriched (or even Low Enriched) Uranium 235 (235U), so entirely complying with the actual international trends and directives concerning the use of this potential highly critical material. The production technique is based on the nuclear reaction 100Mo (p,2n) 99mTc whose production yields have already been documented. Until this moment two Patent requests have already been submitted (the first at the INPI, in Portugal, and the second at the USPTO, in the USA); others are being prepared for submission on a near future. The object of the CYCLOTECH system is to present 99mTc to Nuclear Medicine radiopharmacists in a routine, reliable and efficient manner that, remaining always flexible, entirely blends with established protocols. To facilitate workflow and Radiation Protection measures, it has been developed a Target Station that can be installed on most of the existing PET cyclotrons and that will tolerate up to 400 μA of beam by allowing the beam to strike the Target material at an adequately oblique angle. The Target Station permits the remote and automatic loading and discharge of the Targets from a carriage of 10 Target bodies. On other hand, several methods of Target material deposition and Target substrates are presented. The object was to create a cost effective means of depositing and intermediate the target material thickness (25 - 100μm) with a minimum of loss on a substrate that is able to easily transport the heat associated with high beam currents. Finally, the separation techniques presented are a combination of both physical and column chemistry. The object was to extract and deliver 99mTc in the identical form now in use in radiopharmacies worldwide. In addition, the Target material is recovered and can be recycled.
Resumo:
Soft-tissue and bone necrosis, although rare in childhood, occasionally occur in the course of infectious diseases, either viral or bacterial, and seem to be the result of hypoperfusion on a background of disseminated intravascular coagulation. Treatment consists in correction of septic shock and control of necrosis. Necrosis, once started, shows extraordinarily rapid evolution, leading to soft-tissue and bone destruction and resulting in anatomic, functional, psychological, and social handicaps. Ten mutilated children were treated from January 1986 to January 1999 in Hospital de Dona Estefaˆ nia, Lisbon, Portugal. One was recovering from hemolytic-uremic syndrome with a severe combined immunodeficiency, another malnourished, anemic child had malaria, and three had chicken pox (in one case complicated by meningococcal septicemia). There were three cases of meningococcal and two of pyocyanic septicemia (one in a burned child and one in a patient with infectious mononucleosis). The lower limbs (knee,leg, foot) were involved in five cases, the face (ear, nose, lip) in four, the perineum in three, the pelvis (inguinal region, iliac crest) in two, the axilla in one, and the upper limb (radius, hand) in two. Primary prevention is based on early recognition of risk factors and timely correction. Secondary prevention consists of immediate etiologic and thrombolytic treatment to restrict the area of necrosis. Tertiary prevention relies on adequate rehabilitation with physiotherapy and secondary operations to obtain the best possible functional and esthetic result.
Resumo:
A Masters Thesis, presented as part of the requirements for the award of a Research Masters Degree in Economics from NOVA – School of Business and Economics
Resumo:
The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.
Resumo:
The purpose of this work project is to evaluate Cascais’ potential of becoming a reference in Health Care and Medical Tourism in the near future. It is done a careful research about the industry, followed by a thorough analysis of the region. It is concluded that it holds many key characteristics and conditions for the development of this kind of clusters, even though it lacks consumers’ perception regarding this product. Some guidelines are suggested in order to position Cascais as a competitive player in this field.
Resumo:
ABSTRACT - Objectives: We attempted to show how the implementation of the key elements of the World Health Organization Patient Safety Curriculum Guide Multi-professional Edition in an undergraduate curriculum affected the knowledge, skills, and attitudes towards patient safety in a graduate entry Portuguese Medical School. Methods: After receiving formal recognition by the WHO as a Complementary Test Site and approval of the organizational ethics committee , the validated pre-course questionnaires measuring the knowledge, skills, and attitudes to patient safety were administered to the 2nd and3rd year students pursuing a four-year course (N = 46). The key modules of the curriculum were implemented over the academic year by employing a variety of learning strategies including expert lecturers, small group problem-based teaching sessions, and Simulation Laboratory sessions. The identical questionnaires were then administered and the impact was measured. The Curriculum Guide was evaluated as a health education tool in this context. Results: A significant number of the respondents, 47 % (n = 22), reported having received some form of prior patient safety training. The effect on Patient Safety Knowledge was assessed by using the percentage of correct pre- and post-course answers to construct 2 × 2 contingency tables and by applying Fishers’ test (two-tailed). No significant differences were detected (p < 0.05). To assess the effect of the intervention on Patient Safety skills and attitudes, the mean and standard deviation were calculated for the pre and post-course responses, and independent samples were subjected to Mann-Whitney’s test. The attitudinal survey indicated a very high baseline incidence of desirable attitudes and skills toward patient safety. Significant changes were detected (p < 0.05) regarding what should happen if an error is made (p = 0.016), the role of healthcare organizations in error reporting (p = 0.006), and the extent of medical error (p = 0.005). Conclusions: The implementation of selected modules of the WHO Patient Safety Curriculum was associated with a number of positive changes regarding patient safety skills and attitudes, with a baseline incidence of highly desirable patient safety attitudes, but no measureable change on the patient safety knowledge, at the University of Algarve Medical School. The significance of these results is discussed along with implications and suggestions for future research.
Resumo:
Equity research report
Resumo:
BACKGROUND/OBJECTIVES: This study aims to assess whether patent foramen ovale (PFO) closure is superior to medical therapy in preventing recurrence of cryptogenic ischemic stroke or transient ischemic attack (TIA). METHODS: We searched PubMed for randomized trials which compared PFO closure with medical therapy in cryptogenic stroke/TIA using the items: "stroke or cerebrovascular accident or TIA" and "patent foramen ovale or paradoxical embolism" and "trial or study". RESULTS: Among 650 potentially eligible articles, 3 were included including 2303 patients. There was no statistically significant difference between PFO-closure and medical therapy in ischemic stroke recurrence (1.91% vs. 2.94% respectively, OR: 0.64, 95%CI: 0.37-1.10), TIA (2.08% vs. 2.42% respectively, OR: 0.87, 95%CI: 0.50-1.51) and death (0.60% vs. 0.86% respectively, OR: 0.71, 95%CI: 0.28-1.82). In subgroup analysis, there was significant reduction of ischemic strokes in the AMPLATZER PFO Occluder arm vs. medical therapy (1.4% vs. 3.04% respectively, OR: 0.46, 95%CI: 0.21-0.98, relative-risk-reduction: 53.2%, absolute-risk-reduction: 1.6%, number-needed-to-treat: 61.8) but not in the STARFlex device (2.7% vs. 2.8% with medical therapy, OR: 0.93, 95%CI: 0.45-2.11). Compared to medical therapy, the number of patients with new-onset atrial fibrillation (AF) was similar in the AMPLATZER PFO Occluder arm (0.72% vs. 1.28% respectively, OR: 1.81, 95%CI: 0.60-5.42) but higher in the STARFlex device (0.64% vs. 5.14% respectively, OR: 8.30, 95%CI: 2.47-27.84). CONCLUSIONS: This meta-analysis does not support PFO closure for secondary prevention with unselected devices in cryptogenic stroke/TIA. In subgroup analysis, selected closure devices may be superior to medical therapy without increasing the risk of new-onset AF, however. This observation should be confirmed in further trials using inclusion criteria for patients with high likelihood of PFO-related stroke recurrence.