947 resultados para Materiali compositi, CFRP, Combined Loading Compression (CLC) test method
Resumo:
The need for a stronger and more durable building material is becoming more important as the structural engineering field expands and challenges the behavioral limits of current materials. One of the demands for stronger material is rooted in the effects that dynamic loading has on a structure. High strain rates on the order of 101 s-1 to 103 s-1, though a small part of the overall types of loading that occur anywhere between 10-8 s-1 to 104 s-1 and at any point in a structures life, have very important effects when considering dynamic loading on a structure. High strain rates such as these can cause the material and structure to behave differently than at slower strain rates, which necessitates the need for the testing of materials under such loading to understand its behavior. Ultra high performance concrete (UHPC), a relatively new material in the U.S. construction industry, exhibits many enhanced strength and durability properties compared to the standard normal strength concrete. However, the use of this material for high strain rate applications requires an understanding of UHPC’s dynamic properties under corresponding loads. One such dynamic property is the increase in compressive strength under high strain rate load conditions, quantified as the dynamic increase factor (DIF). This factor allows a designer to relate the dynamic compressive strength back to the static compressive strength, which generally is a well-established property. Previous research establishes the relationships for the concept of DIF in design. The generally accepted methodology for obtaining high strain rates to study the enhanced behavior of compressive material strength is the split Hopkinson pressure bar (SHPB). In this research, 83 Cor-Tuf UHPC specimens were tested in dynamic compression using a SHPB at Michigan Technological University. The specimens were separated into two categories: ambient cured and thermally treated, with aspect ratios of 0.5:1, 1:1, and 2:1 within each category. There was statistically no significant difference in mean DIF for the aspect ratios and cure regimes that were considered in this study. DIF’s ranged from 1.85 to 2.09. Failure modes were observed to be mostly Type 2, Type 4, or combinations thereof for all specimen aspect ratios when classified according to ASTM C39 fracture pattern guidelines. The Comite Euro-International du Beton (CEB) model for DIF versus strain rate does not accurately predict the DIF for UHPC data gathered in this study. Additionally, a measurement system analysis was conducted to observe variance within the measurement system and a general linear model analysis was performed to examine the interaction and main effects that aspect ratio, cannon pressure, and cure method have on the maximum dynamic stress.
Resumo:
We have investigated the influence of long-term confined dynamic compression and surface motion under low oxygen tension on tissue-engineered cell-scaffold constructs. Porous polyurethane scaffolds (8 mm x 4 mm) were seeded with bovine articular chondrocytes and cultured under normoxic (21% O(2)) or hypoxic (5% O(2)) conditions for up to 4 weeks. By means of our joint-simulating bioreactor, cyclic axial compression (10-20%; 0.5 Hz) was applied for 1 h daily with a ceramic ball, which simultaneously oscillated over the construct surface (+/-25 degrees; 0.5 Hz). Culture under reduced oxygen tension resulted in an increase in mRNA levels of type II collagen and aggrecan, whereas the expression of type I collagen was down-regulated at early time points. A higher glycosaminoglycan content was found in hypoxic than in normoxic constructs. Immunohistochemical analysis showed more intense type II and weaker type I collagen staining in hypoxic than in normoxic cultures. Type II collagen gene expression was slightly elevated after short-term loading, whereas aggrecan mRNA levels were not influenced by the applied mechanical stimuli. Of importance, the combination of loading and low oxygen tension resulted in a further down-regulation of collagen type I mRNA expression, contributing to the stabilization of the chondrocytic phenotype. Histological results confirmed the beneficial effect of mechanical loading on chondrocyte matrix synthesis. Thus, mechanical stimulation combined with low oxygen tension is an effective tool for modulating the chondrocytic phenotype and should be considered when chondrocytes or mesenchymal stem cells are cultured and differentiated with the aim of generating cartilage-like tissue in vitro.
Resumo:
BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.
Resumo:
CONTEXT: Magnetic resonance imaging (MRI) combined with magnetic resonance spectroscopy imaging (MRSI) emerged as a promising test in the diagnosis of prostate cancer and showed encouraging results. OBJECTIVE: The aim of this systematic review is to meta-analyse the diagnostic accuracy of combined MRI/MRSI in prostate cancer and to explore risk profiles with highest benefit. EVIDENCE ACQUISITION: The authors searched the MEDLINE and EMBASE databases and the Cochrane Library, and the authors screened reference lists and contacted experts. There were no language restrictions. The last search was performed in August 2008. EVIDENCE SYNTHESIS: We identified 31 test-accuracy studies (1765 patients); 16 studies (17 populations) with a total of 581 patients were suitable for meta-analysis. Nine combined MRI/MRSI studies (10 populations) examining men with pathologically confirmed prostate cancer (297 patients; 1518 specimens) had a pooled sensitivity and specificity on prostate subpart level of 68% (95% CI, 56-78%) and 85% (95% CI, 78-90%), respectively. Compared with patients at high risk for clinically relevant cancer (six studies), sensitivity was lower in low-risk patients (four studies) (58% [46-69%] vs 74% [58-85%]; p>0.05) but higher for specificity (91% [86-94%] vs 78% [70-84%]; p<0.01). Seven studies examining patients with suspected prostate cancer at combined MRI/MRSI (284 patients) had an overall pooled sensitivity and specificity on patients level of 82% (59-94%) and 88% (80-95%). In the low-risk group (five studies) these values were 75% (39-93%) and 91% (77-97%), respectively. CONCLUSIONS: A limited number of small studies suggest that MRI combined with MRSI could be a rule-in test for low-risk patients. This finding needs further confirmation in larger studies and cost-effectiveness needs to be established.
Resumo:
PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.
Resumo:
BACKGROUND Besides carpal tunnel and cubital tunnel syndrome, other nerve compression or constriction syndromes exist at the upper extremity. This study was performed to evaluate and summarize our initial experience with endoscopically assisted decompression. MATERIALS AND METHODS Between January 2011 and March 2012, six patients were endoscopically operated for rare compression or hour-glass-like constriction syndrome. This included eight decompressions: four proximal radial nerve decompressions, and two combined proximal median nerve and anterior interosseus nerve decompressions. Surgical technique and functional outcomes are presented. RESULTS There were no intraoperative complications in the series. Endoscopy allowed both identifying and removing all the compressive structures. In one case, the proximal radial neuropathy developed for 10 years without therapy and a massive hour-glass nerve constriction was observed intraoperatively which led us to perform a concurrent complementary tendon transfer to improve fingers and thumb extension. Excellent results were achieved according to the modified Roles and Maudsley classification in five out of six cases. All but one patient considered the results excellent. The poorest responder developed a CRPS II and refused post-operative physiotherapy. CONCLUSION Endoscopically assisted decompression in rare compression syndrome of the upper extremity is highly appreciated by patients and provides excellent functional results. This minimally invasive surgical technique will likely be further described in future clinical studies.
Resumo:
Computer tomography (CT)-based finite element (FE) models of vertebral bodies assess fracture load in vitro better than dual energy X-ray absorptiometry, but boundary conditions affect stress distribution under the endplates that may influence ultimate load and damage localisation under post-yield strains. Therefore, HRpQCT-based homogenised FE models of 12 vertebral bodies were subjected to axial compression with two distinct boundary conditions: embedding in polymethylmethalcrylate (PMMA) and bonding to a healthy intervertebral disc (IVD) with distinct hyperelastic properties for nucleus and annulus. Bone volume fraction and fabric assessed from HRpQCT data were used to determine the elastic, plastic and damage behaviour of bone. Ultimate forces obtained with PMMA were 22% higher than with IVD but correlated highly (R2 = 0.99). At ultimate force, distinct fractions of damage were computed in the endplates (PMMA: 6%, IVD: 70%), cortex and trabecular sub-regions, which confirms previous observations that in contrast to PMMA embedding, failure initiated underneath the nuclei in healthy IVDs. In conclusion, axial loading of vertebral bodies via PMMA embedding versus healthy IVD overestimates ultimate load and leads to distinct damage localisation and failure pattern.
Resumo:
Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.
Resumo:
Effects of Combined Bevacizumab and Paclitaxel on Tumor Interstitial Fluid Pressure in a Preclinical Breast Cancer Model by Ricardo H. Alvarez Several mechanisms of cell resistance are often accountable for unsuccessful chemotherapy against cancer. Another reason, which has received increased attention, is the inefficient transport of anticancer drugs into tumor tissue. These impaired transports of chemotherapy into the tumor have been attributed to abnormal microvasculature and to pathologically increased tumor hypertension also called: interstitial fluid pressure (IFP). The pathophysiological processes leading to elevated tumor IFP are poorly understood. Here, in a preclinical breast cancer model, it is argued that a condition of raised IFP is a major factor in preventing optimal access of systemically administered chemotherapy agents. In our experimental model, we used a GILM2 human breast cancer in xenografts; mice were treated with different doses of paclitaxel –a widely used antimicrotubular agent, and bevacizumab –monoclonal antibody against vascular endothelial growth factor (VEGF). The proposed research project is designed to test the hypothesis that paclitaxel in combination with bevacizumab decreases the tumor IPF by restoring tumor permeability and increasing chemotherapy delivery. We demonstrated that the combination of paclitaxel and bevacizumab produced greater tumor control than either agent given alone and this combination reduced the IFP, producing an increment of 75% of apoptosis compared with the control arm. In addition, the intra-tumor paclitaxel quantification by liquid chromatography/Mass Spectrometry (LC/MS) demonstrated that lower dose of both agents showed a synergistic effect compared with high dose of treatment, where there is no significantly increase of paclitaxel into the tumor. These preclinical results are likely to have broad implications for the utility of anti-angiogenic therapies alone and in combination with chemotherapeutic agents.
Resumo:
BACKGROUND CONTEXT The Swiss Federal Office of Public Health mandated a nationwide health technology assessment-registry for balloon kyphoplasty (BKP) for decision making on reimbursement of these interventions. The early results of the registry led to a permanent coverage of BKP by basic health insurance. The documentation was continued for further evidence generation. PURPOSE This analysis reports on the 1 year results of patients after BKP treatment. STUDY DESIGN Prospective multicenter observational case series. PATIENT SAMPLE The data on 625 cases with 819 treated vertebrae were documented from March 2005 to May 2012. OUTCOME MEASURES Surgeon-administered outcome instruments were primary intervention form for BKP and the follow-up form; patient self-reported measures were EuroQol-5D questionnaire, North American Spine Society outcome instrument /Core Outcome Measures Index (including visual analog scale), and a comorbidity questionnaire. Outcome measures were back pain, medication, quality of life (QoL), cement extrusions, and new fractures within the first postoperative year. METHODS Data were recorded preoperatively and at 3 to 6-month and 1-year follow-ups. Wilcoxon signed-rank test was used for comparison of pre- with postoperative measurements. Multivariate logistic regression was used to identify factors with a significant influence on the outcome. RESULTS Seventy percent of patients were women with mean age of 71 years (range, 18-91 years); mean age of men was 65 years (range, 15-93 years). Significant and clinically relevant reduction of back pain, improvement of QoL, and reduction of pain killer consumption was seen within the first postoperative year. Preoperative back pain decreased from 69.3 to 29.0 at 3 to 6-month and remained unchanged at 1-year follow-ups. Consequently, QoL improved from 0.23 to 0.71 and 0.75 at the same follow-up intervals. The overall vertebra-based cement extrusion rates with and without extrusions into intervertebral discs were 22.1% and 15.3%, respectively. Symptomatic cement extrusions with radiculopathy were five (0.8%). A new vertebral fracture within a year from the BKP surgery was observed in 18.4% of the patients. CONCLUSIONS The results of the largest observational study for BKP so far are consistent with published randomized trials and systematic reviews. In this routine health care setting, BKP is safe and effective in reducing pain, improving QoL, and lowering pain_killer consumption and has an acceptable rate of cement extrusions. Postoperative outcome results show clear and significant clinical improvement at early follow-up that remain stable during the first postoperative year.
Resumo:
The purpose of this dissertation was to examine the relationship between key psychosocial and behavioral components of the Transtheoretical Model and the Theory of Reasoned Action for sexual risk reduction in a population of crack cocaine smokers and sex workers, not in drug treatment. ^ The first study examined the results of an analysis of the association between two principal constructs in the Transtheoretical Model, the processes of change and the stages of change for condom use, in a high risk population. In the analysis of variance for all respondents, the overall F-test revealed that people in different stages have different levels of experiential process use, F(3,317) = 17.79, p = 0.0001 and different levels of behavioral process use, F(3,317) = 28.59, p = .0001. For the experiential processes, there was a significant difference between the precontemplation/contemplation stage, and both the action, and maintenance, stages.^ The second study explored the relationship between the Theory of Reasoned Action “beliefs” and the stages-of-change in the same population. In the analysis of variance for all participants, the results indicate that people in different stages did value the positive beliefs differently, F(3,502) = 15.38, p = .0001 but did not value the negative beliefs differently, F(3,502) = 2.08, p = .10. ^ The third study explored differences in stage-of-change by gender, partner type drug use, and HIV status. Three discriminant functions emerged, with a combined χ2(12) = 139.57, p = <.0001. The loading matrix of correlations between predictors and discriminant functions demonstrate that the strongest predictor for distinguishing between the precontemplation/contemplation stage and the preparation, action, and maintenance stages (first function) is partner type (.962). The loadings on the second discriminant function suggest that once partner type has been accounted for, ever having HIV/AIDS (.935) was the best predictor for distinguishing between the first three stages and the maintenance stage. ^ These studies demonstrate that behavioral change theories can contribute important insight to researchers and program planners attempting to alter HIV risk behavior in high-risk populations. ^
Resumo:
OBJECTIVE To validate use of stress MRI for evaluation of stifle joints of dogs with an intact or deficient cranial cruciate ligament (CrCL). SAMPLE 10 cadaveric stifle joints from 10 dogs. PROCEDURES A custom-made limb-holding device and a pulley system linked to a paw plate were used to apply axial compression across the stifle joint and induce cranial tibial translation with the joint in various degrees of flexion. By use of sagittal proton density-weighted MRI, CrCL-intact and deficient stifle joints were evaluated under conditions of loading stress simulating the tibial compression test or the cranial drawer test. Medial and lateral femorotibial subluxation following CrCL transection measured under a simulated tibial compression test and a cranial drawer test were compared. RESULTS By use of tibial compression test MRI, the mean ± SD cranial tibial translations in the medial and lateral compartments were 9.6 ± 3.7 mm and 10 ± 4.1 mm, respectively. By use of cranial drawer test MRI, the mean ± SD cranial tibial translations in the medial and lateral compartments were 8.3 ± 3.3 mm and 9.5 ± 3.5 mm, respectively. No significant difference in femorotibial subluxation was found between stress MRI techniques. Femorotibial subluxation elicited by use of the cranial drawer test was greater in the lateral than in the medial compartment. CONCLUSIONS AND CLINICAL RELEVANCE Both stress techniques induced stifle joint subluxation following CrCL transection that was measurable by use of MRI, suggesting that both methods may be further evaluated for clinical use.
Resumo:
INTRODUCTION An accurate description of the biomechanical behavior of the spine is crucial for the planning of scoliotic surgical correction as well as for the understanding of degenerative spine disorders. The current clinical assessments of spinal mechanics such as side-bending or fulcrum-bending tests rely on the displacement of the spine observed during motion of the patient. Since these tests focused solely on the spinal kinematics without considering mechanical loads, no quantification of the mechanical flexibility of the spine can be provided. METHODS A spinal suspension test (SST) has been developed to simultaneously monitor the force applied on the spine and the induced vertebral displacements. The system relies on cervical elevation of the patient and orthogonal radiographic images are used to measure the position of the vertebras. The system has been used to quantify the spinal flexibility on five AIS patients. RESULTS Based on the SST, the overall spinal flexibility varied between 0.3 °/Nm for the patient with the stiffer curve and 2 °/Nm for the less rigid curve. A linear correlation was observed between the overall spinal flexibility and the change in Cobb angle. In addition, the segmental flexibility calculated for five segments around the apex was 0.13 ± 0.07 °/Nm, which is similar to intra-operative stiffness measurements previously published. CONCLUSIONS In summary, the SST seems suitable to provide pre-operative information on the complex functional behavior and stiffness of spinal segments under physiological loading conditions. Such tools will become increasingly important in the future due to the ever-increasing complexity of the surgical instrumentation and procedures.
Resumo:
Computer tomography (CT)-based finite element (FE) models assess vertebral strength better than dual energy X-ray absorptiometry. Osteoporotic vertebrae are usually loaded via degenerated intervertebral discs (IVD) and potentially at higher risk under forward bending, but the influences of the IVD and loading conditions are generally overlooked. Accordingly, magnetic resonance imaging was performed on 14 lumbar discs to generate FE models for the healthiest and most degenerated specimens. Compression, torsion, bending, flexion and extension conducted experimentally were used to calibrate both models. They were combined with CT-based FE models of 12 lumbar vertebral bodies to evaluate the effect of disc degeneration compared to a loading via endplates embedded in a stiff resin, the usual experimental paradigm. Compression and lifting were simulated, load and damage pattern were evaluated at failure. Adding flexion to the compression (lifting) and higher disc degeneration reduces the failure load (8–14%, 5–7%) and increases damage in the vertebrae. Under both loading scenarios, decreasing the disc height slightly increases the failure load; embedding and degenerated IVD provides respectively the highest and lowest failure load. Embedded vertebrae are more brittle, but failure loads induced via IVDs correlate highly with vertebral strength. In conclusion, osteoporotic vertebrae with degenerated IVDs are consistently weaker—especially under lifting, but clinical assessment of their strength is possible via FE analysis without extensive disc modelling, by extrapolating measures from the embedded situation.