954 resultados para Layered perovskites,Photo-Induced Current Transient Spectroscopy,PICTS,deep states,2D perovskites
Resumo:
Laser induced plasma (LIP) emissions from some metal oxide targets were studied with corresponding metal targets of pure quality as a reference. Atomic emissions in the visible region were used in the spectroscopic procedures of LIP characterization. The studies were meant to throw light into LIP dynamics and they provided many experimental results which improved the general awareness of plasma state.When target materials were photo-ablated with an energetically suitable laser pulse, they developed electric charges in them.An electrical signal which was delivered from the target served as an alternative probe signal for the diagnostics of LIP and to track different charged states in the plasma. The signal showed a double peak distribution with positive polarity and a modified time of flight with various voltage levels of a given polarity.The expansion dynamics of LIP in magnetic field were also investigated by monitoring the voltage transients generated at the target.
Resumo:
Dental caries persists to be the most predominant oral disease in spite of remarkable progress made during the past half- century to reduce its prevalence. Early diagnosis of carious lesions is an important factor in the prevention and management of dental caries. Conventional procedures for caries detection involve visual-tactile and radiographic examination, which is considered as “gold standard”. These techniques are subjective and are unable to detect the lesions until they are well advanced and involve about one-third of the thickness of enamel. Therefore, all these factors necessitate the need for the development of new techniques for early diagnosis of carious lesions. Researchers have been trying to develop various instruments based on optical spectroscopic techniques for detection of dental caries during the last two decades. These optical spectroscopic techniques facilitate noninvasive and real-time tissue characterization with reduced radiation exposure to patient, thereby improving the management of dental caries. Nonetheless, a costeffective optical system with adequate sensitivity and specificity for clinical use is still not realized and development of such a system is a challenging task.Two key techniques based on the optical properties of dental hard tissues are discussed in this current thesis, namely laser-induced fluorescence (LIF) and diffuse reflectance (DR) spectroscopy for detection of tooth caries and demineralization. The work described in this thesis is mainly of applied nature, focusing on the analysis of data from in vitro tooth samples and extending these results to diagnose dental caries in a clinical environment. The work mainly aims to improve and contribute to the contemporary research on fluorescence and diffuse reflectance for discriminating different stages of carious lesions. Towards this, a portable and compact laser-induced fluorescence and reflectance spectroscopic system (LIFRS) was developed for point monitoring of fluorescence and diffuse reflectance spectra from tooth samples. The LIFRS system uses either a 337 nm nitrogen laser or a 404 nm diode laser for the excitation of tooth autofluorescence and a white light source (tungsten halogen lamp) for measuring diffuse reflectance.Extensive in vitro studies were carried out on extracted tooth samples to test the applicability of LIFRS system for detecting dental caries, before being tested in a clinical environment. Both LIF and DR studies were performed for diagnosis of dental caries, but special emphasis was given for early detection and also to discriminate between different stages of carious lesions. Further the potential of LIFRS system in detecting demineralization and remineralization were also assessed.In the clinical trial on 105 patients, fluorescence reference standard (FRS) criteria was developed based on LIF spectral ratios (F500/F635 and F500/F680) to discriminate different stages of caries and for early detection of dental caries. The FRS ratio scatter plots developed showed better sensitivity and specificity as compared to clinical and radiographic examination, and the results were validated with the blindtests. Moreover, the LIF spectra were analyzed by curve-fitting using Gaussian spectral functions and the derived curve-fitted parameters such as peak position, Gaussian curve area, amplitude and width were found to be useful for distinguishing different stages of caries. In DR studies, a novel method was established based on DR ratios (R500/R700, R600/R700 and R650/R700) to detect dental caries with improved accuracy. Further the diagnostic accuracy of LIFRS system was evaluated in terms of sensitivity, specificity and area under the ROC curve. On the basis of these results, the LIFRS system was found useful as a valuable adjunct to the clinicians for detecting carious lesions.
Resumo:
Over the past few years, a little word with big potential has been rapidly entering into the world's consciousness-'nano'. Nanoscience and technology is a multidisciplinary field, involving the fabrication and understanding of matter at the finest level of a few nanomters.This thesis is about the synthesis and laser induced studies of nanosized ZnO,a versatile material with a wide range of applications.After synthesizing colloids and films of nano ZnO,the samples are studied using different optical methods.Interactions of intense laser beams with nanosized particles are found to open up many interesting scenarios with possible applications in the field of photonics.
Resumo:
A silver target kept under partial vacuum conditions was irradiated with focused nanosecond pulses at 1:06 mm from a Nd:YAG laser. The electron emission monitored with a Langmuir probe shows a clear twin-peak distribution. The first peak which is very sharp has only a small delay and it indicates prompt electron emission with energy as much as 60 5 eV. Also the prompt electron emission shows a temporal profile with a width that is same as that for the laser pulse whereas the second peak is broader, covers several microseconds, and represents the low-energy electrons (2 0:5 eV) associated with the laser-induced silver plasma as revealed by time-of-flight measurements. It has been found that prompt electrons ejected from the target collisionally excite and ionize ambient gas molecules. Clearly resolved rotational structure is observed in the emission spectra of ambient nitrogen molecules. Combined with time-resolved spectroscopy, the prompt electrons can be used as excitation sources for various collisional excitation–relaxation experiments. The electron density corresponding to the first peak is estimated to be of the order of 1017 cm?--3 and it is found that the density increases as a function of distance away from the target. Dependence of probe current on laser intensity shows plasma shielding at high laser intensities.
Resumo:
Thermal diffusivity measurements are carried out in certain organic liquids using the pulsed dual beam thermal lens technique. The 532 nm pulses from a frequency doubled Q-switched Nd:YAG laser are used as the heating source and an intensity stabilized He-Ne laser serves as the probe beam. Experimental determination of the characteristic time constant of the transient thermal lens signal is verified theoretically. Measured thermal diffusivity values are in excellent agreement with literature values.
Resumo:
A pulsed Nd-YAG laser beam is used to produce a transient refractive index gradient in air adjoining the plane surface of the sample material. This refractive index gradient is probed by a continuous He-Ne laser beam propagating parallel to the sample surface. The observed deflection signals produced by the probe beam exhibit drastic variations when the pump laser energy density crosses the damage threshold for the sample. The measurements are used to estimate the damage threshold for a few polymer samples. The present values are found to be in good agreement with those determined by other methods.
Resumo:
Vibrational overtone spectroscopy of X-H (X=C,N,O) containing molecules is an area of recent interest. The spectroscopic studies of higher vibrational levels yield valuable informations, regarding,the molecular structure, intra- and inter-molecular interactions, radiationless transitions, intra-molecular vibrational relaxations, multiphoton excitations and chemical reactivities, which cannot be z obtained by other spectroscopic methods. This thesis presents the results of experimental investigations on the overtone spectra of some organic compounds in the liquid phase for the characterization of CH bonds. The spectra in the fifth overtone region (1fiV=6) are recorded using a dual beam thermal lens setup and the lower overtones (.AV=2-5) are recorded spectrophotometrically.The thesis is presented in six chapters.
Resumo:
Electrical gas discharges have been the subject of numerous investigations from the last century due to their growing interest in technological and fundamental applications. Absorption of electromagnetic radiation by a gas discharge result into a change in electrical impedance due to a significant perturbations in the steady state population of excited levels and the degree of ionization. This change in impedance produced by resonant absorption of radiation is known as optogalvanic COG) effect. where as that is produced by injecting electrons in to the discharge by photoelectric emission is usually known as photoemission optogalvanic (FOG) effect. With the development of lasers and sophisticated electronic equipment. these effects have established their importance in analytical and spectroscopic measurements. The present thesis deals with the work carried out by the author in the field optogalvanic effect during the past few years at the Department of Physics in Cochin University of Science| and "Fechnology. The results and the observation are summarized in nine chapters and the references to the literature is made at the end of each chapter
Resumo:
In the pre—laser era it was difficult to believe that the optical properties of a medium depend upon the intensity of the radiation incident on it. The basis for this conclusion is that the electric field strength associated with the conventional light sources used before the advent of lasers was much smaller than (103 V/cm) the field sttrengths of atomic or interatomic fields (2 107 —- 10” V/cm). The radiation with such low intensity is not able to affect atomic fields to the extent of changing optical parameters. The invention of laser in 1960 was a turning point. The high degree of coherence of the laser radiation provides high spatial concentration of optical power. With the availability of the femtosecond lasers it has become possible to get extremely high peak powers 2 1013 W/cmz). At such high fields, the relationship between electric ‘polarization P and the electric field strength E ceases to be linear and several nonlinear effects begin to occur. Nonlinear absorption, a branch of nonlinear optics, refers to the interaction between radiation and matter accompanied by absorption of more than one photon. Nonlinear absorption has acquired great importance after the invention of high power lasers. One of the objectives of the present work is to investigate the nonlinear absorption processes occurring in fullerene, selected organic solvents and laser dyes. Fullerenes and laser dyes were chosen because of their highly nonlinear behaviour. Fullerenes, the most beautiful among molecules, offer fascinating field of research owinglto their significant structural properties. As toluene, benzene and carbon disulphide are themost widely used solvents for fullerenes, it seems important to study the nonlinear properties of these liquids as well. Like fullerenes, laser dyes also possess highly delocalized 7r electrons which are responsible for their nonlinear absorption. Dye lasers were the fulfillment of an experimenter’s pipe dream - to have a laser that is easily tunable over a wide range of wavelengths. A better understandingof the photophysical properties of laser dyes can significantly enhance the development and technology of dye lasers. We studied the nonlinear absorption properties of two rhodamine dyes to have some insight into their nonlinear optical properties.
Resumo:
The first direct observation of a hyperfine splitting in the optical regime is reported. The wavelength of the M1 transition between the F = 4 and F = 5 hyperfine levels of the ground state of hydrogenlike ^209 Bi^82+ was measured to be \lamda_0 = 243.87(4) nm by detection of laser induced fluorescence at the heavy-ion storage ring ESR at GSI. In addition, the lifetime of the laser excited F = 5 sublevel was determined to be \tau_0 = 0.351(16) ms. The method can be applied to a number of other nuclei and should allow a novel test of QED corrections in the previously unexplored combination of strong magnetic and electric fields in highly charged ions.
Resumo:
The concept of a "Superheavy Quasiatom" is discussed. Radiative transition times are compared with the lifetime of the intermediate system, cross sections are calculated within a two-collision model and induced transitions and their anisotropic emission are discussed. Recent experimental and theoretical results are presented from collision systems obtained with I-beams bombarding various heavy targets, giving combined Z-values between 120 and 145. Results include the energy dependence of the peak structure interpreted as M X-rays from superheavy quasiatoms and the anisotropy of X-ray emission referred to the beam direction. The data are discussed within the models available. These cannot explain the streng emission of anisotropic radiation in the X-ray energy range of quasiatomic M X-rays at small bombarding energies.
Resumo:
Femtosecond laser pulses are applied to the study of the dynamics and the pathways of multiphoton-induced ionization, autoionization, and fragmentation of Na_2 in molecular-beam experiments. In particular, we report on first results obtained studying electronic autoionization (leading to Na_2{^+} + {e ^-}) and autoionization-induced fragmentation (leading to Na{^+} + Na + {e ^-}) of a bound doubly excited molecular state. The final continuum states are analyzed by photoelectron spectroscopy and by measuring the mass and the released kinetic energy of the corresponding ionic fragments with a time-of-flight arrangement.
Resumo:
We report time-resolved experiments studying the dynamics of the Na_3 B-X system. Femtosecond pump-probe techniques combined with ion time-of-flight (TOF) and zero kinetic energy (ZEKE) photoelectron spectroscopy allow us to observe the three-dimensional wavepacket motion in the excited Na_3 B state and in the Na_3 X state. The ground state wavepacket is induced by stimulated emission pumping during the pump pulse. The X-state dynamics is dominated by the three vibrational modes of the Na_3. Furthermore we observed pseudorotational wavepacket motion in the B state. We do not observe a fragmentation of the B state within a time interval of 10 ps.
Resumo:
This study describes a combined empirical/modeling approach to assess the possible impact of climate variability on rice production in the Philippines. We collated climate data of the last two decades (1985-2002) as well as yield statistics of six provinces of the Philippines, selected along a North-South gradient. Data from the climate information system of NASA were used as input parameters of the model ORYZA2000 to determine potential yields and, in the next steps, the yield gaps defined as the difference between potential and actual yields. Both simulated and actual yields of irrigated rice varied strongly between years. However, no climate-driven trends were apparent and the variability in actual yields showed no correlation with climatic parameters. The observed variation in simulated yields was attributable to seasonal variations in climate (dry/wet season) and to climatic differences between provinces and agro-ecological zones. The actual yield variation between provinces was not related to differences in the climatic yield potential but rather to soil and management factors. The resulting yield gap was largest in remote and infrastructurally disfavored provinces (low external input use) with a high production potential (high solar radiation and day-night temperature differences). In turn, the yield gap was lowest in central provinces with good market access but with a relatively low climatic yield potential. We conclude that neither long-term trends nor the variability of the climate can explain current rice yield trends and that agroecological, seasonal, and management effects are over-riding any possible climatic variations. On the other hand the lack of a climate-driven trend in the present situation may be superseded by ongoing climate change in the future.
Resumo:
Die laserinduzierte Plasmaspektroskopie (LIPS) ist eine spektrochemische Elementanalyse zur Bestimmung der atomaren Zusammensetzung einer beliebigen Probe. Für die Analyse ist keine spezielle Probenpräparation nötig und kann unter atmosphärischen Bedingungen an Proben in jedem Aggregatzustand durchgeführt werden. Femtosekunden Laserpulse bieten die Vorteile einer präzisen Ablation mit geringem thermischen Schaden sowie einer hohen Reproduzierbarkeit. Damit ist fs-LIPS ein vielversprechendes Werkzeug für die Mikroanalyse technischer Proben, insbesondere zur Untersuchung ihres Ermüdungsverhaltens. Dabei ist interessant, wie sich die initiierten Mikrorisse innerhalb der materialspezifschen Struktur ausbreiten. In der vorliegenden Arbeit sollte daher ein schnelles und einfach zu handhabendes 3D-Rasterabbildungsverfahren zur Untersuchung der Rissausbreitung in TiAl, einer neuen Legierungsklasse, entwickelt werden. Dazu wurde fs-LIPS (30 fs, 785 nm) mit einem modifizierten Mikroskopaufbau (Objektiv: 50x/NA 0.5) kombiniert, welcher eine präzise, automatisierte Probenpositionierung ermöglicht. Spektrochemische Sensitivität und räumliches Auflösungsvermögen wurden in energieabhängigen Einzel- und Multipulsexperimenten untersucht. 10 Laserpulse pro Position mit einer Pulsenergie von je 100 nJ führten in TiAl zum bestmöglichen Kompromiss aus hohem S/N-Verhältnis von 10:1 und kleinen Lochstrukturen mit inneren Durchmessern von 1.4 µm. Die für das Verfahren entscheidende laterale Auflösung, dem minimalen Lochabstand bei konstantem LIPS-Signal, beträgt mit den obigen Parametern 2 µm und ist die bislang höchste bekannte Auflösung einer auf fs-LIPS basierenden Mikro-/Mapping-Analyse im Fernfeld. Fs-LIPS Scans von Teststrukturen sowie Mikrorissen in TiAl demonstrieren eine spektrochemische Sensitivität von 3 %. Scans in Tiefenrichtung erzielen mit denselben Parametern eine axiale Auflösung von 1 µm. Um die spektrochemische Sensitivität von fs-LIPS zu erhöhen und ein besseres Verständnis für die physikalischen Prozesse während der Laserablation zu erhalten, wurde in Pump-Probe-Experimenten untersucht, in wieweit fs-Doppelpulse den laserinduzierten Abtrag sowie die Plasmaemission beeinflussen. Dazu wurden in einem Mach-Zehnder-Interferometer Pulsabstände von 100 fs bis 2 ns realisiert, Gesamtenergie und Intensitätsverhältnis beider Pulse variiert sowie der Einfluss der Materialparameter untersucht. Sowohl das LIPS-Signal als auch die Lochstrukturen zeigen eine Abhängigkeit von der Verzögerungszeit. Diese wurden in vier verschiedene Regimes eingeteilt und den physikalischen Prozessen während der Laserablation zugeordnet: Die Thermalisierung des Elektronensystems für Pulsabstände unter 1 ps, Schmelzprozesse zwischen 1 und 10 ps, der Beginn des Abtrags nach mehreren 10 ps und die Expansion der Plasmawolke nach über 100 ps. Dabei wird das LIPS-Signal effizient verstärkt und bei 800 ps maximal. Die Lochdurchmesser ändern sich als Funktion des Pulsabstands wenig im Vergleich zur Tiefe. Die gesamte Abtragsrate variiert um maximal 50 %, während sich das LIPS-Signal vervielfacht: Für Ti und TiAl typischerweise um das Dreifache, für Al um das 10-fache. Die gemessenen Transienten zeigen eine hohe Reproduzierbarkeit, jedoch kaum eine Energie- bzw. materialspezifische Abhängigkeit. Mit diesen Ergebnissen wurde eine gezielte Optimierung der DP-LIPS-Parameter an Al durchgeführt: Bei einem Pulsabstand von 800 ps und einer Gesamtenergie von 65 nJ (vierfach über der Ablationsschwelle) wurde eine 40-fache Signalerhöhung bei geringerem Rauschen erzielt. Die Lochdurchmesser vergrößerten sich dabei um 44 % auf (650±150) nm, die Lochtiefe um das Doppelte auf (100±15) nm. Damit war es möglich, die spektrochemische Sensitivität von fs-LIPS zu erhöhen und gleichzeitig die hohe räumliche Auflösung aufrecht zu erhalten.