929 resultados para Lateral Logic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

α2-Adrenoceptor activation with moxonidine (α2-adrenergic/imidazoline receptor agonist) into the lateral parabrachial nucleus (LPBN) enhances angiotensin II/hypovolaemia-induced sodium intake and drives cell dehydrated rats to ingest hypertonic sodium solution besides water. Angiotensin II and osmotic signals are suggested to stimulate meal-induced water intake. Therefore, in the present study we investigated the effects of bilateral injections of moxonidine into the LPBN on food deprivation-induced food intake and on meal-associated water and 0.3 M NaCl intake. Male Holtzman rats with cannulas implanted bilaterally into the LPBN were submitted to 14 or 24 h of food deprivation with water and 0.3 M NaCl available (n = 6-14). Bilateral injections of moxonidine (0.5 nmol/0.2 μl) into the LPBN increased meal-associated 0.3 M NaCl intake (11.4 ± 3.0 ml/120 min versus vehicle: 2.2 ± 0.9 ml/120 min), without changing food intake (11.1 ± 1.2 g/120 min versus vehicle: 11.2 ± 0.9 g/120 min) or water intake (10.2 ± 1.5 ml/120 min versus vehicle: 10.4 ± 1.2 ml/120 min) by 24 h food deprived rats. When no food was available during the test, moxonidine (0.5 nmol) into the LPBN of 24 h food-deprived rats produced no change in 0.3 M NaCl intake (1.0 ± 0.6 ml/120 min versus vehicle: 1.8 ± 1.1 ml/120 min), nor in water intake (0.2 ± 0.1 ml/120 min versus vehicle: 0.6 ± 0.3 ml/120 min). The results suggest that signals generated during a meal, like dehydration, for example, not hunger, induce hypertonic NaCl intake when moxonidine is acting in the LPBN. Thus, activation of LPBN inhibitory mechanisms seems necessary to restrain sodium intake during a meal. © 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the critical problems in implementing an intelligent grinding process is the automatic detection of workpiece surface burn. This work uses fuzzy logic as a tool to classify and predict burn levels in the grinding process. Based on acoustic emission signals, cutting power, and the mean-value deviance (MVD), linguistic rules were established for the various burn situations (slight, intermediate, severe) by applying fuzzy logic using the Matlab Toolbox. Three practical fuzzy system models were developed. The first model with two inputs resulted only in a simple analysis process. The second and third models have an additional MVD statistic input, associating information and precision. These two models differ from each other in terms of the rule base developed. The three developed models presented valid responses, proving effective, accurate, reliable and easy to use for the determination of ground workpiece burn. In this analysis, fuzzy logic translates the operator's human experience associated with powerful computational methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proton radiation therapy is a precise form of radiation therapy, but the avoidance of damage to critical normal tissues and the prevention of geographical tumor misses require accurate knowledge of the dose delivered to the patient and the verification of his position demand a precise imaging technique. In proton therapy facilities, the X-ray Computed Tomography (xCT) is the preferred technique for the planning treatment of patients. This situation has been changing nowadays with the development of proton accelerators for health care and the increase in the number of treated patients. In fact, protons could be more efficient than xCT for this task. One essential difficulty in pCT image reconstruction systems came from the scattering of the protons inside the target due to the numerous small-angle deflections by nuclear Coulomb fields. The purpose of this study is the comparison of an analytical formulation for the determination of beam lateral deflection, based on Molière's theory and Rutherford scattering with Monte Carlo calculations by SRIM 2008 and MCNPX codes. © 2010 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to growing urbanization and industrialization, the environment is suffering from pollution of rivers, degradation of soils and deteriorated air quality. Quality indices appear to be useful to evaluate the conditions of these media. The aim of this study was the development of a water quality index using a fuzzy inference system, since such an approach has proved advantageous in addressing problems that are subjective by nature or for which the data are uncertain. The methodology employed was based on this inference system, and considered the nine water quality parameters employed by CETESB (Companhia de Tecnologia de Saneamento Ambiental, São Paulo, Brazil) to evaluate water quality. After assessment of the data using the index, a comparison was made with the WQI (Water Quality Index), which is used for the monitoring of various water bodies, including in the study region. The results obtained using the index developed on the basis of fuzzy inference were found to be more useful than those derived from the method currently used by CETESB, since losses and/or omissions concerning individual parameters were minimized. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was performed to evaluate the influence of mandibular lateral excursion, group function and canine guidance on vestibular cervical dental abfraction (VCDA). Thirty-six individuals of both sexes, aged 20 to 45 years, with full natural dentition with at least one tooth with VCDA were selected at the San Marcos University Clinic. We evaluated number of teeth with VCDA per side (left and right), tooth type and lateral excursive movement (canine guidance or group function) affecting it. The results showed no statistical difference (p > 0.05). The tooth type most often showing VCDA was the first lower premolar, with 30.8% on the right side and 36.4% on the left. Moderate positive correlation was found between age and VCDA (R = 0.40). It is concluded that group function during lateral excursion may contribute to presence of VCDA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the effects of end-to-side nerve repair performed only with fibrin glue containing nerve growth in rats. Methods: Seventy two Wistar rats were divided into six equal groups: group A was not submitted to nerve section; group B was submitted to nerve fibular section only. The others groups had the nerve fibular sectioned and then repaired in the lateral surface of an intact tibial nerve, with different procedures: group C: ETS with sutures; group D: ETS with sutures and NGF; group E: ETS with FG only; group F: ETS with FG containing NGF. The motor function was accompanied and the tibial muscle mass, the number and diameter of muscular fibers and regenerated axons were measured. Results: All the analyzed variables did not show any differences among the four operated groups (p>0.05), which were statistically superior to group B (p<0.05), but inferior to group A (p>0.05). Conclusion: The end-to-side nerve repair presented the same recovery pattern, independent from the repair used, showing that the addition of nerve growth factor in fibrin glue was not enough for the results potentiating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of irrigation systems that consume lower water and energy in agriculture is important to supply the growing global demand for food. In this way, it's important to develop techniques that will increase the uniformity of water application on drip irrigation systems. The aim of the work was to compare the provision of lateral lines in drip irrigation, through the formation of wet bulbs in soil and physical parameters of radish, composed of single spacing between drippers in relation to lateral lines composed of two segments, each one composed by different spacing between emitters. Two distributions of evaluation were carried out: 1) conventional drip lateral lines with 20 cm emitter spacing were compared to proposed drip lines, with 24 emitter spacing in the initial section and 20 cm emitter spacing in the final section; 2) conventional drip lateral lines with 30 cm emitter spacing were compared to proposed drip lines, with 36 emitter spacing in the initial section and 30 cm emitter spacing in the final section. The experiment was carried out in a greenhouse of the Sao Manuel Experimental Farm, located at Sao Manuel, SP. The experimental design was entirely randomized, with six treatments and four replications. Results showed no difference among treatments for the most of the evaluated variables. So it is possible to conclude that the use of different spacing between emitters in the same lateral line can be used to increase the line length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-pressure compensating drip hose is widely used for irrigation of vegetables and orchards. One limitation is that the lateral line length must be short to maintain uniformity due to head loss and slope. Any procedure to increase the length is appropriate because it represents low initial cost of the irrigation system. The hypothesis of this research is that it is possible to increase the lateral line length combining two points: using a larger spacing between emitters at the beginning of the lateral line and a smaller one after a certain distance; and allowing a higher pressure variation along the lateral line under an acceptable value of distribution uniformity. To evaluate this hypothesis, a nonlinear programming model (NLP) was developed. The input data are: diameter, roughness coefficient, pressure variation, emitter operational pressure, relationship between emitter discharge and pressure. The output data are: line length, discharge and length of the each section with different spacing between drippers, total discharge in the lateral line, multiple outlet adjustment coefficient, head losses, localized head loss, pressure variation, number of emitters, spacing between emitters, discharge in each emitter, and discharge per linear meter. The mathematical model developed was compared with the lateral line length obtained with the algebraic solution generated by the Darcy-Weisbach equation. The NLP model showed the best results since it generated the greater gain in the lateral line length, maintaining the uniformity and the flow variation under acceptable standards. It had also the lower flow variation, so its adoption is feasible and recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of non-pressure compensating drip hose in horticultural and annual cycle fruits is growing in Brazil. In this case, the challenge for designers is getting longer lateral lines with high values of uniformity. The objective of this study was to develop a model to design longer lateral lines using non-pressure compensating drip hose. Using the developed model, the hypotheses to be evaluated were: a) the use of two different spacing between emitters in the same lateral line allows longer length; b) it is possible to get longer lateral lines using high values of pressure variation in the lateral lines since the distribution uniformity stays below allowable limits. A computer program was developed in Delphi based on the model developed and it is able to design lateral lines in level using non-pressure compensating drip hose. The input data are: desired distribution uniformity (DU); initial and final pressure in the lateral line; coefficients of relationship between emitter discharge and pressure head; hose internal diameter; pipe cross-sectional area with the dripper; and roughness coefficient for the Hazen-Williams equation. The program allows calculate the lateral line length with three possibilities: selecting two spacing between emitters and defining the exchange point; using two pre-established spacing between emitters and calculating the length of each section with different spacing; using one emitter spacing. Results showed that the use of two sections with different spacing between drippers in the lateral line didn't allow longer length but got better uniformity when compared with lateral line with one spacing between emitters. The adoption of two spacing increased the flow rate per meter in the final section which represented approximately 80% of the lateral line total length and this justifies their use. The software allowed DU above 90% with pressure head variation of 40% and the use of two spacing between emitters. The developed model/software showed to be accurate, easy to handle and useful for lateral line design using non-pressure compensating drip hose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To compare autogenous bone (AT) and fresh-frozen allogeneic bone (AL) in terms of histomorphometrical graft incorporation and implant osseointegration after grafting for lateral ridge augmentation in humans. Materials and methods: Thirty-four patients were treated with either AL (20 patients) or AT (14 patients) onlay grafts. During implant installation surgery 6 months after grafting, cylindrical biopsies were harvested perpendicularly to the lateral aspect of the augmented alveolar ridge. Additionally, titanium mini-implants were installed in the grafted regions, also perpendicularly to the ridge; these were biopsied during second-stage surgery. Histological/histomorphometric analysis was performed using decalcified and non-decalcified sections. Results: Histological analysis revealed areas of necrotic bone (NcB) occasionally in contact with or completely engulfed by newly formed vital bone (VB) in both AT and AL groups (55.9 ± 27.6 vs. 43.1 ± 20.3, respectively; P = 0.19). Statistically significant larger amounts of VB (27.6 ± 17.5 vs. 8.4 ± 4.9, respectively; P = 0.0002) and less soft connective tissue (ST) (16.4 ± 15.6 vs. 48.4 ± 18.1, respectively; P ≤ 0.0001) were seen for AT compared with AL. No significant differences were observed between the groups regarding both bone-to-implant contact (BIC) and the bone area between implant threads (BA) on the mini-implant biopsies. Conclusion: Allogeneic bone block grafts may be an option in cases where a limited amount of augmentation is needed, and the future implant can be expected confined within the inner aspect of the bone block. However, the clinical impact of the relatively poor graft incorporation on the long-term performance of oral implants placed in AL grafts remains obscure. © 2013 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bilateral injections of the GABAA agonist muscimol into the lateral parabrachial nucleus (LPBN) disrupt satiety and induce strong ingestion of water and 0.3M NaCl in fluid-replete rats by mechanisms not completely clear. In the present study, we investigated the effects of the blockade of central muscarinic cholinergic receptors with atropine injected intracerebroventricularly (i.c.v.) on 0.3M NaCl and water intake induced by muscimol injections into the LPBN in fluid-replete rats. Male Holtzman rats with stainless steel cannulas implanted bilaterally into the LPBN and unilaterally into the lateral ventricle (LV) were used. Bilateral injections of muscimol (0.5nmol/0.2μL) into the LPBN induced 0.3M NaCl (32.2±9.9mL/4h, vs. saline: 0.4±0.2mL/4h) and water intake (11.4±4.4mL/4h, vs. saline: 0.8±0.4mL/4h) in fluid-replete rats previously treated with i.c.v. injection of saline. The previous i.c.v. injection of atropine (20nmol/1μL) reduced the effects of LPBN-muscimol on 0.3M NaCl (13.5±5.0mL/4h) and water intake (2.9±1.6mL/4h). The i.c.v. injection of atropine did not affect 0.3M NaCl (26.8±6.2mL/2h, vs. saline i.c.v.: 36.5±9.8mL/2h) or water intake (14.4±2.5mL/2h, vs. saline i.c.v.: 15.6±4.8mL/2h) in rats treated with furosemide+captopril subcutaneously combined with bilateral injections of moxonidine (α2-adrenoceptor/imidazoline agonist, 0.5nmol/0.2μL) into the LPBN, suggesting that the effect of atropine was not due to non-specific inhibition of ingestive behaviors. The results show that active central cholinergic mechanisms are necessary for the hypertonic NaCl and water intake induced by the blockade of the inhibitory mechanisms with injections of muscimol into the LPBN in fluid-replete rats. The suggestion is that in fluid-replete rats the action of LPBN mechanisms inhibits facilitatory signals produced by the activity of central cholinergic mechanisms to maintain satiety. © 2012 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The relationship between the immune response and red and white blood cell homeostasis is cited in literature, but no studies regarding the balance of these cell populations following maxillary bone-graft surgeries can be found. Aim: The aim of this study was to evaluate the possible impairments in the blood cell balance following fresh-frozen allogeneic bone-graft augmentation procedures in patients who needed maxillary reconstruction prior to implants. Material and Methods: From 33 patients elected to onlay bone grafting procedures, 20 were treated with fresh-frozen bone allografts and 13 with autologous bone grafts. Five blood samples were collected from each patient in a 6-month period (baseline: 14, 30, 90, and 180 days postsurgery), and the hematological parameters (erythrogram, leukogram, and platelets count) were accessed. Results: All evaluated parameters were within the reference values accepted as normal, and significant differences were found for the eosinophils count when comparing the treatments (30 days, p=.035) and when comparing different periods of evaluation (allograft-treated group, baseline×180 days, p≤.05 and 90×180 days, p≤.01; autograft-treated group, 30×90 days, p≤.05 and 30×180 days, p≤.05). Conclusions: Both autologous and fresh-frozen allogeneic bone grafts did not cause any impairment in the red and white blood cell balance, based on quantitative hemogram analysis, in patients subjected to maxillary reconstruction. © 2011 Wiley Periodicals, Inc.