775 resultados para LITHIUM FLUORIDES
Resumo:
When the electro-optic and acousto-optic effects are combined into a single device, the resulting acousto-electro-optic (AEO) modulator shows improved flexibility to overcome some limitations of the individual modulators or their cascade combinations. By using optical interferometry, it is possible to investigate the AEO modulator behavior as a function of this applied voltage. By this way, a lithium niobate AEO modulator is positioned in one of the arms of a Mach-Zehnder interferometer and operates at 62 MHz frequency, which constitutes the intermediate frequency of the heterodyne interferometer. Operating the AEO modulator in the acousto-optic small diffraction efficiency regime, the photodetected signal amplitude and phase are analyzed, and the induced phase shift, transmission curve and linearity response are obtained. The experimental results show good agreement with that expected from the coupled-mode theory. The possibility of linear control of the optical phase shift by the external voltage, from 0 to 2 p radians, is demonstrated.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The projected rotational velocity together with lithium abundance and the onset of the dilution by the deepening in mass of the convective envelope provide a key tool to investigate the so far poorly understood processes at work in stellar interiors of solar-analog stars. To investigate the link between abundances, convection and rotational velocities in solar-analog G dwarf stars, we study a bona fide sample of 118 selected solar-analog G dwarf stars presenting measured lithium abundances, rotational velocities, and fundamental parameters together with computed evolutionary tracks (Toulouse-Geneva code) for a range of stellar masses around 1 M and metallicity consistent with the solar-analog range. The aim of this work is to build up an evolution of lithium and rotation as a function of stellar age, mass, effective temperature, and convection. We analyze the evolutionary status of the sample of 118 solar-analog G dwarf in the HR diagram based on Hipparcos data and using a grid of stellar models in the effective temperature and mass range of the solar-analog stars. We discuss the deepening (in mass) of the convective envelope and the influence on the Li abundances and projected rotational velocities. We determined the stellar mass and the mass of the convective envelope for a bona fide sample of 118 selected solar-analog G dwarf and checked the evolutionary link between the rotational velocity, lithium abundance, and the deepening of the convective envelope. Fast rotators (vsini 6 km s��1) are also stars with high Li content. Slow rotators present a wide range of values of log n(Li). Our results shed new light on the lithium and rotational behavior in G dwarf stars. We confirmed the presence of a large Li abundance spread among the solar-analog stars and concluded that the solar twins probably share a similar mixing history with the Sun
Resumo:
OBJETIVO: Avaliar a posição do supercílio em diferentes idades, utilizando medidas angulares. MÉTODOS: Foram avaliados indivíduos com idade de 4 a 6 anos (Grupo de crianças) e igual ou superior a 50 anos (Grupo de idosos), separados em faixas etárias, avaliando-se a posição do supercílio por meio de imagens digitais, utilizando medidas angulares. As imagens foram tomadas em posição primária do olhar, utilizando filmadora Sony Lithium, e posteriormente transferidas para computador MacIntosh G4 e processadas pelo programa NIH 1,58. Os parâmetros analisados foram: ângulo interno, externo e vertical da cauda do supercílio. As comparações foram entre sexos, faixas etárias e lateralidade. Os resultados obtidos foram submetidos à análise estatística. RESULTADOS: A comparação das medidas angulares mostrou que houve diferença significativa na posição da cauda do supercílio entre os grupos estudados quando comparados dentro do grupo com faixa etária semelhante. Porém, comparando-se crianças e adultos, houve diferença em todos os tipos de ângulos estudados. CONCLUSÕES: A posição do supercílio avaliada por medidas angulares mostrou diferenças entre crianças e idosos, revelando associação positiva com a idade.
Resumo:
OBJETIVO: Estabelecer o padrão de normalidade do ritmo de piscar em crianças normais em idade pré-escolar. MÉTODOS: Avaliaram-se 200 crianças de 4 a 6 anos, saudáveis, usando tomada de imagens digitais, nos planos frontal e lateral, em estado de vigília, em posição primária do olhar, estando o objeto de observação localizado na altura da pupila. Para a tomada das imagens foi utilizada uma filmadora Sony Lithium, sendo as mesmas gravadas em fitas 8 mm, transferidas para um computador MacIntosh G4 e processadas pelo programa iMovie, estudando-se: o tempo de abertura e o tempo de fechamento palpebral, o tempo de piscar completo e o ritmo de movimentos palpebrais por minuto, durante 3 minutos. Os resultados foram avaliados por estatística descritiva e gráfico de linhas. RESULTADOS: O piscar completo foi mais freqüente que o incompleto. O ritmo do piscar completo aumenta com o aumento da idade. Para o piscar incompleto, os valores foram semelhantes em todas as idades avaliadas. O tempo de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em meninos e meninas. O tempo de fechamento foi mais lento que o tempo de abertura palpebral. CONCLUSÕES: O ritmo de piscar completo aumenta com a idade. Os tempos de fechamento e de abertura palpebral e o tempo de piscar completo foram semelhantes em ambos os sexos, em todas as idades estudadas, sendo o fechamento mais lento que a abertura palpebral.
Resumo:
OBJETIVO: Avaliar quantitativamente as mudanças da posição palpebral e as medidas da fenda palpebral de indivíduos acima dos 50 anos. MÉTODOS: Estudo observacional, tendo sido avaliados 325 indivíduos, com idade acima de 50 anos, segundo distância intercantal, largura e altura da fenda palpebral, ângulo palpebral externo e interno, distância entre o reflexo pupilar e a margem da pálpebra superior (distância reflexo-margem) e a área total da fenda palpebral. Utilizou-se filmadora Sony Lithium para obtenção das imagens digitais, com o indivíduo fixando um objeto a 1 metro de distância, sendo as imagens transferidas posteriormente para computador McIntosh G4 e processadas pelo programa NIH 1.58. Os dados foram submetidos à análise estatística. RESULTADOS: Os participantes apresentavam dermatocálase (96,5%), ptose do supercílio (60,8%), prolapso de gordura orbital (50,0%) ou ptose palpebral (39,1%). As alterações foram bilaterais em 68,8% dos indivíduos. A distância intercantal aumentou com a idade; a largura da fenda palpebral, a distância reflexo-margem e a medida do ângulo externo diminuíram nos mais idosos. As diferenças foram mais significativas quando os olhos foram estudados separadamente. CONCLUSÃO: A distância intercantal aumenta, ao passo que a largura da fenda palpebral, a distância reflexo-margem e a área total da fenda palpebral diminuem com o aumento da idade.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os cimentos ionoméricos representam importante opção de material restaurador em Odontologia e sua adesão à estrutura dental, diminuindo a infiltração marginal, somada à liberação de flúor, inibindo o metabolismo de microrganismos acidogênicos e favorecendo a remineralização dental, podem diminuir a ocorrência de cárie secundária. A aplicação tópica de géis acidulados ou neutros contendo flúor tem sido largamente utilizada em Odontologia. No entanto, este procedimento pode afetar a integridade dos materiais restauradores, aumentando sua rugosidade e a retenção de placa bacteriana. Dessa forma, o presente estudo avaliou o período de tempo no qual o cimento ionomérico Vitremer mantém sua capacidade inibitória sobre Streptococcus mutans ATCC 25175 e a adesão dos mesmos sobre a superfície do material, bem como a influência da aplicação tópica de flúor acidulado e neutro sobre esses parâmetros microbiológicos e as características superficiais daquele material. Verificou-se que a atividade antimicrobiana do cimento ionomérico Vitremer se mantém por aproximadamente quatro dias e não é recuperada com o uso de flúor gel acidulado ou neutro. Observou-se, também, que Streptococcus mutans ATCC 25175 adere ao material restaurador testado sendo que a aplicação tópica de flúor não influenciou esta adesão. As características superficiais desses materiais não se alteraram com a aplicação dos géis.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Despite a plethora of in situ studies and clinical trials evaluating the efficacy of fluoridated dentifrices on caries control, in vitro pH cycling models are still broadly used because they mimic the dynamics of mineral loss and gain involved in caries formation. This paper critically reviews the current literature on existing pH-cycling models for the in vitro evaluation of the efficacy of fluoridated dentifrices for caries control, focusing on their strengths and limitations. A search was undertaken in the MEDLINE electronic journal database using the keywords "pH-cycling", "demineralization", "remineralization", "in vitro", "fluoride", "dentifrice". The primary outcome was the decrease of demineralization or the increase of remineralization as measured by different methods (e. g.: transverse microradiography) or tooth fluoride uptake. Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. One hundred and sixteen studies were included, of which 42 addressed specifically the comparison of dentifrices using different pH-cycling models. The other studies included meta-analysis or reviews, data about the effect of different fluoride sources on de-remineralization, different methods for analysis de-remineralization and chemical variables and characteristics of dental hard tissues that might have influence on de-remineralization processes. Generally, the studies presented ability to detect known results established by clinical trials, to demonstrate dose-related responses in the fluoride content of the dentifrices, and to provide repeatability and reproducibility between tests. In order to accomplish these features satisfactorily, it is mandatory to take into account the type of substrate and baseline artificial lesion, as well as the adequate response variables and statistical approaches to be used. This critical review of literature showed that the currently available pH-cycling models are appropriate to detect dose-response and pH-response of fluoride dentifrices, and to evaluate the impact of new active principles on the effect of fluoridated dentifrices, as well as their association with other anti-caries treatments.
Resumo:
Because of the growing concerns regarding fluoride ingestion by young children and dental fluorosis, it is necessary to develop new dentifrices. Objective: The aim of this study was to evaluate the effect of dentifrices with calcium citrate (Cacit) and sodium trimetaphosphate (TMP) on enamel demineralization. Material and Methods: Enamel blocks (n=70), previously selected through surface hardness analysis, were submitted to daily treatment with dentifrices diluted in artificial saliva and to a pH-cycling model. The fluoride concentration in dentifrices was 0, 250, 450, 550, 1,000 and 1,100 mu g F/g. Crest (TM) was used as a positive control (1,100 mu g F/g). Cacit (0.25%) and TMP (0.25%) were added to dentifrices with 450 and 1,000 mu g F/g. Surface hardness was measured again and integrated loss of subsurface hardness and fluoride concentration in enamel were calculated. Parametric and correlation tests were used to determine difference (p<0.05) and dose-response relationship between treatments. Results: The addition of Cacit and TMP did not provide a higher fluoride concentration in enamel, however it reduced (p<0.05) mineral loss when compared to other dentifrices; the dentifrice with Cacit and TMP and a low fluoride concentration presented similar results when compared to a dentifrice with 1,100 mu g F/g (p>0.05). Conclusions: Dentifrices with 450 and 1,000 mu g F/g, Cacit and TMP were as effective as a gold standard one.
Resumo:
Although the prevalence of caries has decreased dramatically over the past decades, it has become a polarised disease, with most of subjects presenting low caries levels and few individuals accounting for most of the caries affected surfaces. Thus it become evident for the need of clinical approaches directed at these high-risk patients, in order to overcome problems related to compliance and low attendance at dental care centres. Slow-release fluoride devices were developed based on the inverse relationship existing between intra-oral fluoride levels and dental caries experience. The two main types of slow-release devices - copolymer membrane type and glass bead - are addressed in the present review. A substantial number of studies have demonstrated that these devices are effective in raising intra-oral F concentrations at levels able to reduce enamel solubility, resulting in a caries-protective effect. Studies in animals and humans demonstrated that the use of these devices was able to also protect the occlusal surfaces, not normally protected by conventional fluoride regimens. However, retention rates have been shown to be the main problem related to these devices and still requires further improvements. Although the results of these studies are very promising, further randomised clinical trials are needed in order to validate the use of these devices in clinical practice. The concept of continuously providing low levels of intra-oral fluoride has great potential for caries prevention in high caries-risk groups.
Resumo:
Objectives: The aim of this in vitro study was to assess the effects of saliva substitutes (modified with respect to calcium, phosphates, and fluorides) in combination with a high-concentrated fluoride toothpaste on demineralised dentin.Methods: Before and after demineralisation of bovine dentin specimens (subsurface lesions; 37 degrees C, pH 5.0, 5 d), one-quarter of each specimen's surface was covered with nail varnish (control of sound/demineralised tissue). Subsequently, specimens were exposed to original Saliva natura (saturation with respect to octacalciumphosphate [S(OCP)]: 0.03; SN 0), or to three lab-produced Saliva natura modifications (S(OCP): 1, 2, and 3; SN 1-3) for 2 and 5 weeks (37 degrees C). An aqueous solution (S(OCP): 2.5) served as positive control (PC). Two times daily (2 min each), Duraphat toothpaste (5000 ppm F(-); Colgate)/saliva substitute slurry (ratio 1:3) was applied gently. Differences in mineral losses (Delta Delta Z) and lesion depths (Delta LD) between values before and after exposure were microradiographically evaluated.Results: After both treatment periods specimens immersed in SN 0 revealed significantly higher mineral losses (lower Delta Delta Z values) and lesion depths (lower Delta LD) compared to PC (p < 0.05; ANOVA). After 5 weeks, specimens stored in SN 1 and 2 showed significantly higher mineral losses compared to PC (p < 0.05), while those stored in SN 3 showed similar results (p > 0.05). No differences in mineral loss could be observed between SN 2 and 3 (p > 0.05).Conclusions: Under the conditions of this limited protocol, the combination of Saliva natura solutions slightly saturated with respect to OCP in combination with a high-concentrated fluoride toothpaste enabled remineralisation of dentin in vitro. Crown Copyright (c) 2009 Published by Elsevier Ltd. All rights reserved.
Resumo:
Esta revisão visa ser uma introdução à aplicação de materiais cerâmicos em dispositivos de armazenamento de energia, em especial baterias secundárias de íons lítio, dispositivos nos quais os materiais cerâmicos, especialmente óxidos, são muito importantes em todas as partes do dispositivo. A revisão está focada nos materiais cerâmicos para catodos e anodos, partes chaves destes dispositivos. Ela tem por principal finalidade ser uma fonte de informação para aqueles que desejem trabalhar com o desenvolvimento de materiais cerâmicos para tais tipos de dispositivos. Aspectos relacionados à nanotecnologia e materiais óxidos nanoestruturados para esta área são discutidos ao final do artigo.