997 resultados para Indústria - Consumo de energia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper analyses the sustainability under the environmental (ecological) perspective of Water Supply and Sanitary Sewers Systems from Uberaba city, MG. It was accomplished in this analysis, An Environmental Sustainability Assessment of those systems, by the means of specific sustainability indicators proposed for Uberaba, but which may be used for other simi-lar cities. To the characterization of the systems, visitations were made to the main units as well as a documental was elaborated. The definition of the level or stage of the sustainability by the indicators was made based on a literature review, on interviews with the technicians and managers of the systems and based on the characterization and observation of the system reality, being attributed to them the following classification: Non Sustainable, Low Sustaina-bility, Medium Sustainability and High Sustainability. It was verified that the indicators that have lower compatibility to the process of sustainability to the studied systems are those rela-ted to the water physical losses, to the water per capita consumption, to the electricity con-sumption and to the sludge from the water treatment plants disposal untreated into a water body, for the Water Supply System. And those ones related to the attendance with sewage treatment, to the electricity consumption and to the usage of the treated sewage, for the Sani-tary Sewers, all of them classified as Non Sustainable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A crescente evolução da utilização das Tecnologias de Informação (TI), nomeadamente em instituições e empresas, faz com que exista um aumento no consumo da energia elétrica e elevados custos de manutenção associados. Com esta situação, existe cada vez mais a preocupação em arranjar formas/técnicas de baixar este consumo, isto é, a necessidade de gerir estes consumos de forma a que se consiga baixar a fatura energética. O presente trabalho tem como objetivo estudar possibilidades de eficiência energética associado a um parque informático distribuído, nomeadamente estudar o que pode ser feito para reduzir consumos num edifício escolar, utilizando como caso de estudo uma escola do Instituto Politécnico de Leiria. Esta dissertação apresenta diferentes propostas de modo a que se consigam reduzir os consumos energéticos, nomeadamente com a substituição de equipamentos por outros mais eficientes. Numa parte inicial, o trabalho abrange uma visão global sobre técnicas que têm vindo a ser desenvolvidas para melhorar a eficiência energética em sistemas computacionais. Efetuaram-se medições de consumos, tanto em equipamentos como em sala, durante um período experimental, de modo a obter conclusões sobre os valores obtidos com a substituição dos equipamentos existentes por equipamentos eficientes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Na ultima década, a necessidade da definição de objectivos de gestão por parte das entidades gestoras, e a correspondente necessidade de verificação do cumprimento dos objectivos estabelecidos, levaram à implementação de iniciativas para o estudo e desenvolvimento de metedologias no domínio de avaliação de desempenho dos serviços de saneamento. O presente trabalho tem como principal objectivo, a avaliação do desempenho das nove infraestruturas em exploração pela SIMLIS, SA, tendo-se seleccionado, para este efeito, doze indicadores de desempenho,distribuídos pelos domínios da qualidade da água tratada; da eficiência e fiabilidade da ETAR; da utilização de água, energia e materiais; e da gestão de subprodutos. Como aspectos da avaliação de desempenho foram seleccionados, a conformidade com a licença de descarga, a qualidade da água rejeitada no meio recetor, a eficiência global da ETAR, o consumo de energia, o consumo de reagentes, a utilização de águas residuais tratadas, a produção e valorização de lamas e a produção de biogás. Para o processo de avaliação de desempenho, definiu-se um período de análise de um ano, nomeadamente o ano de 2013, para o qual se estabeleceram metas para cada um dos indicadores a avaliar. Conclui-se que a avaliação de desempenho é uma ferramenta essencial à gestão, pois permitiu analisar, não só o desempenho global da entidade gestora, mas também, avaliar o desempenho individual de cada uma das infraestruturas. Foi ainda possível, em alguns casos, avaliar o desempenho das ETAR em função do tipo de processo de tratamento utilizado. O uso adequado desta ferramenta de avaliação de desempenho permitiu à SIMLIS, de uma forma mais eficiente, aplicar acções correctivas quando identificados problemas e optimizar recursos, sendo usada como ferramenta de apoio à decisão.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O crescente consumo de energia, bem como a possibilidade de esgotamento dos recursos não renováveis, tem fomentado a busca de fontes de energia alternativas. O biodiesel é um biocombustível obtido a partir de fontes renováveis e a sua utilização permite reduzir as emissões de gases com efeito de estufa. Nos últimos anos tem-se produzido biodiesel a partir de óleos alimentares usados (OAU), sendo que com esta aplicação valoriza-se um resíduo e simultaneamente produz-se um combustível “verde”. O biodiesel é produzido através das reações de transesterificação e/ou esterificação entre triglicerídeos e/ou ácidos gordos livres e um álcool, na presença de um catalisador. O rendimento do processo está estritamente relacionado com o tipo de catalisador e as condições que este opera. O principal objetivo do presente trabalho consistiu na avaliação do efeito de alguns parâmetros operacionais no desempenho de uma lípase imobilizada (Novozyme® 435), nomeadamente: (i) índice de acidez do óleo, (ii) razão mássica de enzima/óleo e (iii) método regeneração da enzima com vista à sua reutilização. Também foi objeto de estudo do presente trabalho a produção em contínuo, num (bior)reator tubular de leito fixo, de ésteres metílicos de ácidos gordos (FAME) usando a referida enzima. Registou-se um aumento rendimento em com o incremento do índice de acidez do óleo usado, o que indicia que a enzima catalisa simultaneamente as reações de esterificação e transesterificação. Relativamente à razão mássica de enzima/óleo, dentro da gama testada verificou-se um aumento do rendimento em FAME com a concentração da enzima em meio reacional. Dos vários solventes testados, a aplicação de solvente tert-butanol na regeneração (com incubação) da enzima foi o que melhores resultados teve. Finalmente, os resultados obtidos no ensaio de produção de FAME num biorreator contínuo são motivadores, criando expectativas de uma possível aplicação industrial no futuro.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The consumption of energy on the planet is currently based on fossil fuels. They are responsible for adverse effects on the environment. Renewables propose solutions for this scenario, but must face issues related to the capacity of the power supply. Wind energy offshore emerging as a promising alternative. The speed and stability are greater winds over oceans, but the variability of these may cause inconvenience to the generation of electric power fluctuations. To reduce this, a combination of wind farms geographically distributed was proposed. The greater the distance between them, the lower the correlation between the wind velocity, increasing the likelihood that together achieve more stable power system with less fluctuations in power generation. The efficient use of production capacity of the wind park however, depends on their distribution in marine environments. The objective of this research was to analyze the optimal allocation of wind farms offshore on the east coast of the U.S. by Modern Portfolio Theory. The Modern Portfolio Theory was used so that the process of building portfolios of wind energy offshore contemplate the particularity of intermittency of wind, through calculations of return and risk of the production of wind farms. The research was conducted with 25.934 observations of energy produced by wind farms 11 hypothetical offshore, from the installation of 01 simulated ocean turbine with a capacity of 5 MW. The data show hourly time resolution and covers the period between January 1, 1998 until December 31, 2002. Through the Matlab R software, six were calculated minimum variance portfolios, each for a period of time distinct. Given the inequality of the variability of wind over time, set up four strategies rebalancing to evaluate the performance of the related portfolios, which enabled us to identify the most beneficial to the stability of the wind energy production offshore. The results showed that the production of wind energy for 1998, 1999, 2000 and 2001 should be considered by the portfolio weights calculated for the same periods, respectively. Energy data for 2002 should use the weights derived from the portfolio calculated in the previous time period. Finally, the production of wind energy in the period 1998-2002 should also be weighted by 1/11. It follows therefore that the portfolios found failed to show reduced levels of variability when compared to the individual production of wind farms hypothetical offshore

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O gradual consumo de energia primária a nível mundial deu origem a uma crise não só ambiental como também económica, proveniente das limitações das reservas energéticas e do fornecimento. Estas inquietações têm levado a um estudo cada vez mais aprofundado no que concerne à eficiência energética de edifícios. É neste contexto que surge o estudo da aplicação dos materiais de mudança de fase (PCM) na térmica dos edifícios. O presente trabalho consiste no estudo da influência da introdução de materiais de mudança de fase no comportamento térmico de um edifício. Foi analisada uma simulação numérica para um sistema solar passivo de ganho direto, por um programa de simulação designado EXTEND™. Efetuou-se, também, o estudo paramétrico de determinadas propriedades associadas aos materiais de mudança de fase. Após a análise, foi testado o impacto, em termos de conforto, da utilização de materiais de mudança de fase em sistemas solares passivos de ganho direto.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A pressão causada sobre os recursos energéticos é impulsionada pela evolução demográfica e pelo crescimento económico, que se vem registando principalmente nos países em desenvolvimento. Segundo várias estatísticas, a procura pela energia incide principalmente sobre os combustíveis fósseis, os quais, representam cerca de do mix de consumo mundial de energia primária. A incerteza sobre as reservas das fontes energéticas não renováveis, e os problemas ambientais derivados da sua conversão noutros tipos de energia, levaram a uma implementação de medidas com rumo à sustentabilidade e eficiência energética. Desta forma, o aumento da utilização sobre as fontes energéticas renováveis é de extrema importância. A biomassa é uma das fontes energéticas de maior relevo. A utilização de biomassa em caldeiras, oferece benefícios económicos, sociais e ambientais, tais como poupança financeira no combustível, conservação dos recursos fósseis e redução de emissões poluentes. As caldeiras desenvolvidas por empresas como a Ventil, são uma solução para a produção de energia térmica pela combustão da biomassa. Estes sistemas caracterizam-se por serem energeticamente eficientes nas várias componentes da sua operação. Assim, pretende-se fazer uma caracterização dos consumos energéticos associados à operação de uma caldeira Ventil de, nomeadamente o consumo de energia elétrica de equipamentos associados. Também será considerado um balanço energético da caldeira e determinado o seu rendimento. Desta forma, concluiu-se que a potência do sistema é de MJ/s, apresentando um rendimento de. Foram detetados motores mal dimensionados e apresentadas alternativas de substituição. Com um investimento de seria possível reduzir a fatura energética em, obtendo um payback de anos. No entanto, a fatura energética do sistema ultrapassa os anuais, sendo que do investimento é na compra do combustível e os restantes são relativos ao consumo de energia elétrica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

No panorama energético atual, medidas de desenvolvimento sustentável têm uma preponderância cada vez mais significativa e, sendo os edifícios responsáveis por 40% da energia consumida na EU, enquadra-se o desafio de integrar medidas de eficiência energética nos novos edifícios desde a fase de conceção. Sendo que este setor se encontra em contínua expansão, a redução dos consumos passará largamente pela otimização do comportamento térmico dos edifícios e dos sistemas energéticos que os equipam. No presente trabalho estudou-se o papel da inércia térmica na redução das necessidades de energia para climatização de edifícios com o objetivo de identificar estratégias destinadas ao melhoramento do comportamento térmico e desempenho energético de edifícios construídos com recurso à técnica construtiva LSF, caracterizados por uma fraca inércia térmica quando comparados com edifícios em tudo semelhantes mas construídos recorrendo a tecnologias convencionais sem esquecer as questões relacionadas com a respetiva viabilidade económica. Com resultado geral destaca-se desde logo a importância do local onde é mais benéfico adicionar massa térmica (paredes exteriores, cobertura, paredes interiores), assim como a necessidade de utilização de um material com elevada densidade energética e baixo custo. A análise comparativa dos diferentes modelos de edifício simulados com recurso ao software DesignBuilder/EnergyPlus, foi realizada recorrendo a uma metodologia em que cada modelo construtivo é avaliado considerando quatro níveis de isolamento térmico e duas condições de cargas térmicas internas. A análise energética e económica foi realizada tendo como referência um período de 20 anos. O custo das soluções construtivas foi maioritariamente obtido através da ferramenta computacional Gerador de Preços, da Cype, SA©, tendo-se considerado um consumo energético anual constante e igual às necessidades de climatização anuais, assim como taxas de atualização de capital e de inflação do custo da energia constantes. De uma forma geral conclui-se que edifícios do tipo LSF melhorados através da adição criteriosa de massa térmica em determinados elementos construtivos, apresentam necessidades de climatização anuais na maioria dos casos estudados, inferiores àquelas verificadas em edifícios convencionais com inércia térmica média/forte. Conclui-se, também, que o método construtivo LSF se apresenta mais eficaz em termos energéticos e económicos quando comparado com soluções semelhantes construídas com recurso a um método convencional. Na secção seguinte são identificadas as principais conclusões deste trabalho.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente relatório de projeto explicita as etapas da elaboração e os resultados obtidos através da realização de um projeto de reabilitação energética de um complexo de piscinas interiores. Esta reabilitação energética tem por objetivo a redução dos custos energéticos através da subtração de consumos supérfluos de energia ou da melhoria da eficiência energética dos equipamentos. Para alcançar estes objetivos recorreu-se à simulação dinâmica do edifício de modo a estimar múltiplas variáveis energéticas e identificar quais os setores e equipamentos que maior influência têm no consumo energético do complexo em estudo. Para a realização da simulação, recorreu-se a um software desenvolvido pelo DOE dos Estados Unidos da América, o Energy Plus, com o auxílio do Design Builder, que permite a criação e edição do modelo de forma mais fácil e acessível. Os valores retirados da simulação foram posteriormente comparados com valores reais. Com o complexo caraterizado e os principais consumidores identificados foi possível iniciar o estudo das medidas de melhoria da eficiência energética. As principais medidas estudadas incidiram na instalação de coberturas isotérmicas nas piscinas para reduzir a perda de energia através da evaporação e da radiação, a introdução de fontes de energia renovável como alternativa energética, substituição de elementos do sistema de iluminação e o aproveitamento de energia dissipada em equipamentos. Com este estudo, a entidade gestora do complexo encontra-se mais informada e pronta a tomar decisões que influenciem de forma significativa o consumo de energia no complexo, podendo optar pela instalação de alguma das medidas propostas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Public Lightning is an important part of municipality’s nighttime landscape. Lighting can be used to enhance public safety and security while improving the aesthetic appeal of the surrounding properties but with the current global financial crisis, such lighting systems must also be sustainable. Most climate policy efforts focus on the state and international level, however national governments won’t be able to meet their international commitments without local action. In Portugal, the Public Lighting is responsible for 3% of energy consumption. The problem is that the trend is to increase (about 4-5% per year) which represents very high costs for the municipal authorities. In terms of numbers are analyzed in this thesis 45 of 278 existent in Continental Portugal what represents only 16,2 % of the counties. This where the local authorities in Portugal that had a Sustainable Energy Action Plan (SEAP) that had been accepted and made available in the Covenant of Mayors website until the end of year 2013. It is important that the Covenant of Mayors will increase the local authorities awareness for energy efficiency and especially to public lighting because there is still a long way to go in terms of energy consumption reduction. In future works it would be interesting to see the payback of the EolGreen post in a real scenario due to lack of energy consumption from the grid it would allow to have a pretty high initial investment even with the maintenance that those technologies need.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tesis (Ingeniero Eléctrico). -- Universidad de La Salle. Faculltad de Ingeniería. Programa de Ingeniería Eléctrica, 2014

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tesis (Ingeniero Eléctrico). -- Universidad de La Salle. Faculltad de Ingeniería. Programa de Ingeniería Eléctrica, 2013