954 resultados para IT-solutions
Resumo:
Background: Many chronic liver diseases lead to progressive hepatic fibrosis, a condition that can ultimately result in loss of organ function and severe portal hypertension necessitating hepatic transplantation. Within the last few decades, studies have been conducted to demonstrate the possibility of drug modulation of hepatic fibrogenesis. Regarding biliary obstruction, it has been suggested that administration of corticosteroids could promote better late outcomes for children with biliary atresia submitted to Kasai`s portoenterostomy. Models used to test potential antifibrogenic drugs such as pentoxifylline (PTX) have not included growing animals. Methods: In this experimental study, 119 young rats (21st or 22nd days) were submitted to laparotomy and common bile duct ligation (CBDL) or to sham surgery (SHAM). Animals were allocated into 5 groups, according to surgical procedure, and administered the following solutions: (1) CBDL + distilled water, (2) SHAM + distilled water, (3) CBDL + PTX, (4) CBDL + prednisolone (PRED), and (5) CBDL + PTX + PRED (PTX + PRED). Each group was further divided into 2 subgroups according to the length of the experiment (15 or 30 days). At the end of the defined period, animals were weighed, and a hepatic fragment was collected from each one for analyses. Results: The PTX animals exhibited increased weight gain compared to animals in the PRED or PTX + PRED groups. Animals from the 3 therapeutic groups (PTX, PRED, and PTX + PRED) showed diminished collagen-filled area in portal spaces. Total portal space area was increased in the PTX group. Conclusions: Hepatic fibrosis induced by bile duct ligation in young rats could be modulated by pharmacologic interventions. Administration of PTX or PRED, or the combination of both, resulted in diminished collagen-filled areas in portal spaces. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Fleet enemas are hypertonic solutions with an osmotic action and a high concentration of phosphate. When retained in the human body they have a great toxic potential, causing severe hydro-electrolyte disorders in children, especially in newborns. We report the case of a previously healthy 8-day-old newborn who needed neonatal intensive care treatment after the inadvertent administration of an osmotically active hypertonic phosphate enema. Taking into account that phosphate removal by peritoneal dialysis (PD) strongly depends on total dialysate turnover, we chose continuous flow PD (CFPD) as the treatment option, with a successful outcome. Clinical experience with this dialytic modality is limited to a few case reports in pediatric and adult patients. To the best of our knowledge, we report here the first description of CFPD in the setting of acute phosphate nephropathy in the neonatal period. The modality of PD described here has potential as an alternative management option as it is a highly efficient, methodologically simple, and low-cost method without any need for sophisticated equipment. Physicians and parents should be aware of the adverse effects of a hypertonic phosphate enema and should never use these medications in infants and newborns.
Resumo:
Background: Splanchnic perfusion is prone to early injury and persists despite normalization of global hemodynamic variables in sepsis. Volume replacement guided by oxygen derived variables has been recommended in the management of septic patients. Our hypothesis was that a hypertonic isoneotic solution Would improve the benefits of crystalloids replacement guided by mixed venous oxygen saturation. Methods: Seventeen anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live E. coli in 30 minutes. They were then randomized into three groups: control group (n = 3) bacterial infusion without treatment; normal saline (n = 7), initial fluid replacement with 32 mL/kg of normal saline during 20 minutes; hypertonic solution (n = 7), initial fluid replacement with 4 mL/kg of hypertonic solution during 5 minutes. After 30 and 60 Minutes, additional boluses of normal saline were administered when mixed venous oxygen saturation remained below 70%. Mean arterial pressure, cardiac output; regional blood flows, systemic and regional oxygen-derived variables, and lactate levels were assessed. Animals were observed for 90 minutes and then killed. Hystopathological analysis including apoptosis detection using terminal deoxynucleotidil transferase mediated dUTP-biotin nick end labeling was performed. Results: A hypodynamic septic shock was observed after bacterial infusion. Both the fluid-treated groups presented similar transient benefits in systemic and regional variables. A greater degree of gut epithelial cells apoptosis was observed in normal saline-treated animals. Conclusions: Although normalization of mixed venous oxygen saturation was not associated with restoration of markers of splanchnic or other systemic perfusion variables, the initial fluid savings with hypertonic saline and its latter effect on gut apoptosis may be of interest in sepsis management.
Resumo:
Objective: To evaluate in chest X-rays and high-resolution computed tomographies of patients with pleural tuberculosis, the incidence of parenchymal and mediastinal lung lesions suggestive of active disease. Methods: Prospective study (2008-2009) evaluating the radiographic and tomographic abnormalities of 88 HIV-negative patients with pleural tuberculosis (unilateral effusion). The images were reviewed by 3 independent specialists, and the observed changes were classified according to previously established criteria: presence or absence of signs suggestive of disease activity, and nonspecific findings. Results: Abnormal changes were observed in chest X-rays of 22 (25%) patients and in the computed tomography of 55 (63%). Images compatible with active pulmonary tuberculosis were detected by radiography in 9 (10%) patients and by tomography in 38 (43%). Only 4 (4.5%) patients had tomography images suggestive of residual disease. Conclusion: The present study demonstrates that pulmonary involvement is quite common in pleural tuberculosis. This finding is mainly observed in high-resolution computed tomography and has important epidemiological implications, since patients with pleural tuberculosis are significant sources of infection and disease dissemination. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to evaluate the efficacy of a cost-effective intra-oral appliance for obstructive sleep apnea syndrome built into a large teaching hospital. Out of 20 evaluated and treated patients, 14 concluded the study: eight men and six women, with a mean age of 42-46 (mean + SD) years and mean body mass index of 27.66. Inclusion criteria were mild or moderate apnea-hypopnea index (AHI) according to a polysomnographic study. All patients were treated with the monobloco intra-oral appliance. They were then submitted to a follow-up polysomnographic study after 60 days using the appliance. An orofacial clinical evaluation was carried out with the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) questionnaire and with clinical evaluation questionnaire devised by the Orofacial Pain Team before and 60 days after fitting the intra-oral appliance. The AHI showed a statistically meaningful (p = 0.002) reduction from 15.53 to 7.82 events per hour, a non-statistically significant oxygen saturation increase from 83.36 to 84.86 (p = 0.09), and Epworth`s sleepiness scale reduction from 9.14 to 6.36 (p = 0.001). Three patients did not show any improvement. The most common side effect during the use of the appliance/device was pain and facial discomfort (28.57%), without myofascial or temporomandibular joint pain as evaluated by the RDC/TMD questionnaire. The intra-oral device produced a significant reduction of the apnea-hypopnea index during the study period with the use of the monobloco intra-oral appliance. Patients did not show prior myofascial pain or 60 days after use of the intra-oral appliance.