994 resultados para Harrison, Clifford.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Understanding links between the El Nino-Southern Oscillation (ENSO) and snow would be useful for seasonal forecasting, but also for understanding natural variability and interpreting climate change predictions. Here, a 545-year run of the general circulation model HadCM3, with prescribed external forcings and fixed greenhouse gas concentrations, is used to explore the impact of ENSO on snow water equivalent (SWE) anomalies. In North America, positive ENSO events reduce the mean SWE and skew the distribution towards lower values, and vice versa during negative ENSO events. This is associated with a dipole SWE anomaly structure, with anomalies of opposite sign centered in western Canada and the central United States. In Eurasia, warm episodes lead to a more positively skewed distribution and the mean SWE is raised. Again, the opposite effect is seen during cold episodes. In Eurasia the largest anomalies are concentrated in the Himalayas. These correlations with February SWE distribution are seen to exist from the previous June-July-August (JJA) ENSO index onwards, and are weakly detected in 50-year subsections of the control run, but only a shifted North American response can be detected in the anaylsis of 40 years of ERA40 reanalysis data. The ENSO signal in SWE from the long run could still contribute to regional predictions although it would be a weak indicator only

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The global atmospheric electrical circuit sustains a vertical current density between the ionosphere and the Earth's surface, the existence of which is well-established from measurements made in fair-weather conditions. In overcast, but non-thunderstorm, non-precipitating conditions, the current travels through the cloud present, despite cloud layers having low electrical conductivity. For extensive layer clouds, this leads to space charge at the upper and lower cloud boundaries. Using a combination of atmospheric electricity and solar radiation measurements at three UK sites, vertical current measurements have been categorised into clear, broken, and overcast cloud conditions. This approach shows that the vertical “fair weather” current is maintained despite the presence of cloud. In fully overcast conditions with thick cloud, the vertical current is reduced compared to thin cloud overcast conditions, associated with the cloud's resistance contributions. Contribution of cloud to the columnar resistance depends both on cloud thickness, and the cloud's height.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the importance of microphysical cloud processes on the climate system, some topics are under-explored. For example, few measurements of droplet charges in nonthunderstorm clouds exist. Balloon carried charge sensors can be used to provide new measurements. A charge sensor is described for use with meteorological balloons, which has been tested over a range of atmospheric temperatures from -60 to 20 degrees C, in cloudy and clear air. The rapid time response of the sensor (to >10 V s(-1)) permits charge densities from 100 fC m(-3) to 1 nC m(-3) to be determined, which is sufficient for it to act as a cloud edge charge detector at weakly charged horizontal cloud boundaries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic sensors have been added to a standard weather balloon radiosonde package to detect motion in turbulent air. These measure the terrestrial magnetic field and return data over the standard uhf radio telemetry. Variability in the magnetic sensor data is caused by motion of the instrument package. A series of radiosonde ascents carrying these sensors has been made near a Doppler lidar measuring atmospheric properties. Lidar-retrieved quantities include vertical velocity (w) profile and its standard deviation (w). w determined over 1 h is compared with the radiosonde motion variability at the same heights. Vertical motion in the radiosonde is found to be robustly increased when w>0.75 m s−1 and is linearly proportional to w. ©2009 American Institute of Physics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The atmosphere's fair weather electric field is a permanent feature, arising from the combination of distant thunderstorms, Earth's conducting surface, a charged ionosphere and cosmic ray ionization. Despite its ubiquity, no fair weather electricity effect on clouds has been hitherto demonstrated. Here we report surface measurements of radiation emitted and scattered by extensive thin continental cloud, which, after ~2 min delay, shows changes closely following the fair weather electric field. For typical fluctuations in the fair weather electric field, changes of about 10% are subsequently induced in the diffuse short-wave radiation. These observations are consistent with enhanced production of large cloud droplets from charging at layer cloud edges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Foggy air and clear air have appreciably different electrical conductivities. The conductivity gradient at horizontal droplet boundaries causes droplet charging, as a result of vertical current flow in the global atmospheric electrical circuit. The charging is poorly known, as both the current flow through atmospheric water droplet layers and the air conductivity are poorly characterised experimentally. Surface measurements during three days of continuous fog using new instrument techniques show that a shallow (of order 100 m deep) fog layer still permits the vertical conduction current to pass. Further, the conductivity in the fog is estimated to be approximately 20% lower than in clear air. Assuming a fog transition thickness of one metre, this implies a vertical conductivity gradient of order 10 fS m−2 at the boundary. The actual vertical conductivity gradient at a cloud boundary would probably be greater, due to the presence of larger droplets in clouds compared to fog, and cleaner, more conductive clear air aloft.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An improved amplifier for atmospheric fine wire resistance thermometry is described. The amplifier uses a low excitation current (50 mu A). This is shown to ensure negligible self-heating of the low mass fine wire resistance sensor, compared with measured nocturnal surface air temperature fluctuations. The system provides sufficient amplification for a +/- 50 degrees C span using a +/- 5 V dynamic range analog-to-digital converter, with a noise level of less than 0.01 degrees C. A Kelvin four-wire connection cancels the effect of long lead resistances: a 50 m length of screened cable connecting the Reading design of fine wire thermometer to the amplifier produced no measurable temperature change at 12 bit resolution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A highly stable microvolt amplifier for use with atmospheric broadband thermopile radiometers is described. The amplifier has a nominal gain of 500, for bipolar input signals in the range +/- 10 mV from a floating source. The noise level at the input is less than 5 mu V (at 100 k Omega input impedance), permitting instantaneous diffuse solar radiation measurements to 0.5 W m(-2) resolution with 12 bit analog to digital conversion. The temperature stability of gain is better than 5 ppm/degrees C (-4 to 20 degrees C). Averaged over a decade of use, the long term drift of the amplifier gain is less than similar to 0.02%/yr. As well as radiometers measuring solar and terrestrial radiations, the amplifier has also been successfully used with low level signals from thermocouples and ground heat flux plates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A vertical conduction current flows in the atmosphere as a result of the global atmospheric electric circuit. The current at the surface consists of the conduction current and a locally generated displacement current, which are often approximately equal in magnitude. A method of separating the two currents using two collectors of different geometry is investigated. The picoammeters connected to the collectors have a RC time constant of approximately 3 s, permitting the investigation of higher frequency air-earth current changes than previously achieved. The displacement current component of the air-earth current derived from the instrument agrees with calculations using simultaneous data from a co-located fast response electric field mill. The mean value of the nondisplacement current measured over 9 h was 1.76 +/- 0.002 pA m(-2). (c) 2006 American Institute of Physics.