980 resultados para GRAFT SUBSTITUTES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Percutaneous endovascular procedures have become the standard treatment of arteriovenous fistulae and graft stenosis. This study evaluates the immediate results of angiographic procedures performed by nephrologists in patients with dysfunctional arteriovenous fistulae and arteriovenous graft stenosis. Patients and Methods. A retrospective analysis was performed on patients referred to the three Interventional Nephrology units between April and June, 2010. Clinical data were recorded. Results. A total of 113 procedures were performed: 59 in arteriovenous fistulae and 54 in arteriovenous graft stenosis. The main reasons for referral were increased venous pressure (21%), limb oedema (21%) and decreased intra-access flow (20%). Stenoses were detected in 85% of the procedures, mostly in patients with arteriovenous graft stenosis (56%). The main locations of stenosis were the outflow vein (cephalic/basilic) in arteriovenous fistulae (34%) and venous anastomosis in arteriovenous graft stenosis(48%). Angioplasty was performed in 73% of procedures where stenoses were detected. The immediate success rate was 91% for arteriovenous fistulae and 83% for arteriovenous graft stenosis. Partial success was obtained in 11% of angiographies. The complication rate was 7%. Conclusions. Physical examination findings led, in at least half the cases, to angiography referral and enabled the diagnosis and treatment of stenoses. For this reason, we advocate that this tool should be included in any vascular access monitoring programme. Our results support the safety of these procedures performed by nephrologists and their efficacy in the recovery of dysfunctional arteriovenous fistulae and arteriovenous graft stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To characterise clinically the patients with C4d in peritubular capillaries deposits (C4dPTCD) and/or circulating anti-HLA class I/II alloantibodies. To determine the correlation between positive C4dPTCD and circulating anti-HLA class I/II alloantibodies during episodes of graft dysfunction. Subjects and Methods: C4d staining was performed in biopsies with available frozen tissue obtained between January 2004 and December 2006. The study was prospective from March 2005, when a serum sample was obtained at the time of biopsy to detect circulating anti-HLA class I/II alloantibodies. Results: We studied 109 biopsies in 86 cadaver renal transplant patients. Sixteen of these (14.7%) presented diffuse positive C4dPTCD. There was a 13.5% rate of +C4dPTCD incidence within the first six months of transplantation and 16% after six months (p>0.05). Half of the +C4dPTCD in the first six months was associated with acute humoral rejection. After six months, the majority of +C4dPTCD (n=7/8) was present in biopsies with evidence of interstitial fibrosis/tubular atrophy and/or transplant glomerulopathy. The C4dPTCD was more frequent in patients with positive anti-HCV antibodies(p<0.0001), a previous renal transplant (p=0.007), and with a panel reactivity antibody (PRA) ≥ 50%(p=0.0098). The anti-HCV+ patients had longer time on dialysis (p=0.0019) and higher PRA(p=0.005). Circulating anti-HLA I/II alloantibodies were screened in 46 serum samples. They were positive in 10.9% of samples, all obtained after six months post transplant. Circulating alloantibodies were absent in 92.5% of the C4d negative biopsies. Conclusion: We found an association between the presence of C4dPTCD and 2nd transplant recipients,higher PRA and the presence of anti-HCV antibodies. The presence of HCV antibodies is not a risk factor for C4dPTCD per se, but appears to reflect longer time on dialysis and presensitisation. In renal dysfunction a negative alloantibody screening is associated with a reduced risk of C4dPTCD (<10%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projecto apresentado para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ensino de Inglês

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: There is much controversy regarding the current indications and contraindications for digital replantation. PRESENTATION OF CASE: Three patients with absolute contraindications for digital replantation according to classical criteria are presented (Case 1: multilevel amputation of the hand and fingers; Case 3: avulsion of the thumb; Case 4: index amputation proximal to the insertion of the flexor digitorum superficialis). In addition a patient with a very distal digital amputation (Case 2), whose indication for replantation is controversial is also presented. In all cases, the patients were replanted and showed good functional and aesthetical results. DISCUSSION: Most authors advocate that the classical indications for replantation have been validated by experience, are predicated on the potential for long-term function, and should be followed in most if not all cases. However, some surgeons have been adopting a more liberal attitude with good results. CONCLUSION: The clinical cases presented in this paper suggest that the standard criteria for digital replantation should not be followed rigidly but instead should be regarded as a general guide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transplant glomerulopathy is a sign of chronic kidney allograft damage. It has a distinct morphology and is associated with poor allograft survival. We aimed to assess the prevalence and clinic-pathologic features of transplant glomerulopathy, as well as determine the functional and histological implications of its severity. We performed a single-centre retrospective observational study during an eight-year period. Kidney allograft biopsies were diagnosed and scored according to the Banff classification, coupled with immunofluorescence studies. The epidemiology, clinical presentation, outcomes (patient and graft survival) and anti-HLA alloantibodies were evaluated. Transplant glomerulopathy was diagnosed in 60 kidney transplant biopsies performed for clinical reasons in 49 patients with ABO compatible renal transplant and a negative T-cell complement dependent cytotoxicity crossmatch at transplantation. The estimated prevalence of transplant glomerulopathy was 7.4% and its cumulative prevalence increased over time. C4d staining in peritubular capillaries (27.6%) was lower than the frequency of anti-HLA antibodies (72.5%), the majority against both classes I and II. Transplant glomerulopathy was associated with both acute (mainly glomerulitis and peritubular capillaritis) and chronic histologic abnormalities. At diagnosis, 30% had mild, 23.3% moderate and 46.7% severe transplant glomerulopathy. The severity of transplant glomerulopathy was associated with the severity of interstitial fibrosis. Other histological features, as well as clinical manifestations and graft survival, were unrelated to transplant glomerulopathy severity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To retrospectively review the hybrid treatment of the aortic arch with supra-aortic debranching and endo- vascular stent-graft repair in a single institution. Methods: From 2007 to 2010, all patients submitted to aortic debranching procedures were entered into a prospective database analysis. For the present study, only patients with sealing zones 0 and 1, according to the Ishimaru classification, were included. Procedure-related morbimortality was analysed for the open and endovascular procedures. Results: During the study period, we electively performed 6 total aortic debranching and 4 partial aortic debranching procedures in 10 patients. According to the etiology the indications were: 6 aortic arch aneurysms, 2 post-dissection aneu- rysms, 1 false aneurysm and 1 type I endoleak following TEVAR. The proximal sealing zone was Ishimaru zone 0 in six patients and zone 1 in four patients. The TEVAR procedure was delayed in all patients with a completion success of 80% (1 patient died from ruptured aortic aneurysm; 1 patient denied the second procedure and was lost to follow-up). The 30d mortality rate was 10% (patient mentioned above). The main morbidity was: 1 axillar venous thrombosis, 1 case of subclinical myocardial infarction, 1 case of terminal renal insufficiency and 1 case of prolonged ventilation. No permanent cerebral or peripheral neurologic deficit was noted. Conclusions: The hybrid repair of the aortic arch is a feasible and reproducible procedure, and our results are similar to the previously published series. Medium and long-term results are necessary to confirm whether the technique can be regarded as a safe alternative to open surgery in high-risk patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau Mestre em Engenharia Biomédica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 50-year-old post-menopausal recipient of a kidney allograft with bone pain, osteoporosis, persistent hypercalcaemia and elevated parathormone (PTH) levels, despite a satisfactory graft function, was treated with bisphosphonates and cinacalcet starting, respectively, 5 and 6 months after renal transplantation (RT). Sixteen months after treatment, there was improvement of bone mineral density (BMD) measured by dualenergy X-ray absorptiometry (DEXA). A bone biopsy was taken, unveiling a surprising and worrisome result. Post-RT bone disease is different from classic CKD-MBD and should be managed distinctly, including, in some difficult cases, an invasive evaluation through the performance of a bone biopsy, as suggested in the KDIGO guidelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine if mid-term outcome following endovascular aneurysm repair (EVAR) with the Endurant Stent Graft (Medtronic, Santa Rosa, CA, USA) is influenced by severe proximal neck angulation. METHODS: A retrospective case-control study was performed using data from a prospective multicenter database. All measurements were obtained using dedicated reconstruction software and center-lumen line reconstruction. Patients with neck length >15 mm, infrarenal angle (β) >75°, and/or suprarenal angle (α) >60°, or neck length >10 mm with β >60°, and/or α >45° were compared with a matched control group. Primary endpoint was primary clinical success. Secondary endpoints were freedom from rupture, type 1A endoleak, stent fractures, freedom from neck-related reinterventions, and aneurysm-related adverse events. Morphological neck variation over time was also assessed. RESULTS: Forty-five patients were included in the study group and were compared with a matched control group with 65 patients. Median follow-up time was 49.5 months (range 30.5-58.4). The 4-year primary clinical success estimates were 83% and 80% for the angulated and nonangulated groups (p = .42). Proximal neck angulation did not affect primary clinical success in a multivariate model (hazard ratio 1.56, 95% confidence interval 0.55-4.41). Groups did not differ significantly in regard to freedom from rupture (p = .79), freedom from type 1A endoleak (p = .79), freedom from neck-related adverse events (p = .68), and neck-related reinterventions (p = .68). Neck angle reduction was more pronounced in patients with severe proximal neck angulation (mean Δα -15.6°, mean Δβ -30.6°) than in the control group (mean Δα -0.39°, mean Δβ -5.9°) (p < .001). CONCLUSION: Mid-term outcomes following EVAR with the Endurant Stent Graft were not influenced by severe proximal neck angulation in our population. Despite the conformability of the device, moderate aortic neck remodeling was identified in the group of patients with angulated neck anatomy on the first computed tomography scan after implantation with no important further remodeling afterwards. No device integrity failures were encountered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The decrease in the number of cadaveric donors has proved a limiting factor in the number of liver transplants, leading to the death of many patients on the waiting list. The living donor liver transplantation is an option that allows, in selected cases, increase the number of donors. One of the most serious complications in liver transplantation is hepatic artery thrombosis, in the past considered potentially fatal without urgent re-transplantation. A white male patient, 48 years old, diagnosed with hepatocellular carcinoma in chronic liver failure caused by hepatitis B virus, underwent living donor liver transplantation (right lobe). Doppler echocardiography performed in the immediate postoperative period did not identify arterial flow in the right branch, having been confirmed thrombosis of the right hepatic artery in CT angiography. Urgent re-laparotomy was performed, which consisted of thrombectomy and re-anastomosis of the hepatic artery with segmental splenic artery allograft interposition. The patient started anticoagulation and antiplatelet therapy with acetylsalicylic acid. Serial evaluation with Doppler echocardiography showed hepatic artery patency. At present, the patient is asymptomatic. One of the most devastating complications in liver transplantation, and particularly in living liver donor, is thrombosis of the hepatic artery; thus, early diagnosis and treatment is vital. The rapid intervention for revascularization of the graft avoids irreversible ischemia of the bile ducts and hepatic parenchyma, thus avoiding the need for re-transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atheroembolic renal disease, also referred to as cholesterol crystal embolization, is a rare cause of renal failure, secondary to occlusion of renal arteries, renal arterioles and glomerular capillaries with cholesterol crystals, originating from atheromatous plaques of the aorta and other major arteries. This disease can occur very rarely in kidney allografts in an early or a late clinical form. Renal biopsy seems to be a reliable diagnostic test and cholesterol clefts are the pathognomonic finding. However, the renal biopsy has some limitations as the typical lesion is focal and can be easily missed in a biopsy fragment. The clinical course of these patients varies from complete recovery of the renal function to permanent graft loss. Statins, acetylsalicyclic acid, and corticosteroids have been used to improve the prognosis. We report a case of primary allograft dysfunction caused by an early and massive atheroembolic renal disease. Distinctive histology is presented in several consecutive biopsies. We evaluated all the cases of our Unit and briefly reviewed the literature. Atheroembolic renal disease is a rare cause of allograft primary non -function but may become more prevalent as acceptance of aged donors and recipients for transplantation has become more frequent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The clinical importance of humoral-mediated acute rejection has been progressively recognised. Early recognition and treatment with plasmapheresis and intravenous immunoglobulin have recently improved short term prognosis. Case report: In this report we describe the clinical features of three 2nd transplant patients developing severe acute humoral rejection during the first week post-transplant while on anti-thymocyte globulin therapy. Treatment with plasmapheresis/ intravenous immunoglobulin/rituximab resulted in rapid reversal of oliguria,and recovery of renal function within the 1st week of treatment in 2/3 patients. Diagnosis was confirmed by graft biopsies revealing peritubular neutrophiles and C4d deposits. Sequential graft biopsies in all three patients revealed complete histological recovery within two weeks. One patient never recovered renal function, and one patient lost his graft at three months following hemorrhagic shock. After 2 years follow up, the remaining patient maintains a serum creatinine of 1.1mg/dl. Conclusion: The regimen using plasmapheresis plus intravenous immunoglobulin and rituximab was effective in rapidly reversing severe acute humoral rejection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To access the incidence of infectious problems after liver transplantation (LT). Design. A retrospective, single-center study. Materials and Methods. Patients undergoing LT from January 2008 to December 2011 were considered. Exclusion criterion was death occurring in the first 48 hours after LT. We determined the site of infection and the bacterial isolates and collected and compared recipient’s variables, graft variables, surgical data, post-LT clinical data. Results. Of the 492 patients who underwent LT and the 463 considered for this study, 190 (Group 1, 41%) developed at least 1 infection, with 298 infections detected. Of these, 189 microorganisms were isolated, 81 (51%) gram-positive bacteria (most frequently Staphylococcus spp). Biliary infections were more frequent (mean time of 160.4 167.7 days after LT); from 3 months after LT, gram-negative bacteria were observed (57%). Patients with infections after LT presented lower aminotransferase levels, but higher requirements in blood transfusions, intraoperative vasopressors, hemodialysis, and hospital stay. Operative and cold ischemia times were similar. Conclusion. We found a 41% incidence of all infections in a 2-year follow-up after LT. Gram-positive bacteria were more frequent isolated; however, negative bacteria were commonly isolated later. Clinical data after LT were more relevant for the development of infections. Donors’ variables should be considered in future analyses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics