990 resultados para G1


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the intrapulpal temperature variation after bleaching treatment with 35% hydrogen peroxide using different sources of activation. Material and Methods: Twenty-four human teeth were sectioned in the mesiodistal direction providing 48 specimens, and were divided into 4 groups (n=12): (G1) Control - Bleaching gel without light activation, (G2) Bleaching gel + halogen light, (G3) Bleaching gel + LED, (G4) Bleaching gel + Nd: YAG Laser. The temperatures were recorded using a digital thermometer at 4 time points: before bleaching gel application, 1 min after bleaching gel application, during activation of the bleaching gel, and after the bleaching agent turned from a dark-red into a clear gel. Data were analyzed statistically by the Dunnet's test, ANOVA and Tukey's test (alpha=0.05). Results: The mean intrapulpal temperature values (degrees C) in the groups were: G1: 0.617 +/- 0.41; G2: 1.800 +/- 0.68; G3: 0.975 +/- 0.51; and G4: 4.325 +/- 1.09. The mean maximum temperature variation (MTV) values were: 1.5 degrees C (G1), 2.9 degrees C (G2), 1.7 degrees C (G3) and 6.9 degrees C (G4). When comparing the experimental groups to the control group, G3 was not statistically different from G1 (p>0.05), but G2 and G4 presented significantly higher (p<0.05) intrapulpal temperatures and MTV. The three experimental groups differed significantly (p<0.05) from each other. Conclusions: The Nd: YAG laser was the activation method that presented the highest values of intrapulpal temperature variation when compared with LED and halogen light. The group activated by LED light presented the lowest values of temperature variation, which were similar to that of the control group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of different cleaning media on the adhesion of resin cement to feldspathic ceramic after etching.Materials and Methods: The cementation surfaces of ceramic blocks (N = 20, n = 5 per group) were etched with 10% hydrofluoric acid (HF) gel for 20 s and rinsed for 60 s. They were then randomly assigned to 4 groups: G1: air-water spray+drying (control); G2: ultrasonic cleaning in distilled water for 4 min+drying; G3: ultrasonic cleaning in 99.5% acetone for 4 min+drying; G4: ultrasonic cleaning in 70% alcohol for 4 min+drying. The ceramic blocks were silanized and cemented (RelyX ARC) to the composite blocks. Subsequently, the microtensile bond strength test (mu TBS) was performed. In addition, EDS analysis was made to assess the elemental composition of the conditioned and cleaned ceramic surfaces.Results: A significantly higher mean mu TBS was obtained when specimens had been ultrasonically cleaned in distilled water (G2: 18.8 +/- 0.4 MPa) (p < 0.05) compared to other groups (G1: 16.6 +/- 0.5; G3: 16.1 +/- 0.9; G4: 15.8 +/- 1.4) (one-way ANOVA). EDS analysis indicated the presence of F- only in G1. Dissolved precipitates after HF etching were removed by ultrasonic cleaning.Conclusion: Cleaning the HF-etched ceramic surface ultrasonically in distilled water is recommended, instead of rinsing it with air-water spray only.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of surface treatment on the shear bond strength between a Co-Cr alloy and two ceramics.Materials and Methods: Forty-eight metal cylinders were made (thickness: 4 mm, height: 3.7 mm) according ISO TR 11405. The 48 metallic cylinders were divided into four groups (n = 12), according to the veneering ceramic (StarLight Ceram and Duceram Kiss) and surface treatments: air-particle abrasion with Al(2)O(3) or tungsten drill (W). Gr1: StarLight + Al(2)O(3); Gr2: StarLight + W; Gr3: Duceram + Al(2)O(3); and Gr4: Duceram + W. The specimens were aged using thermal cycling (3000 x, 5 to 55 degrees C, dwell time: 30 seconds, transfer time: 2 seconds). The shear test was performed with a universal testing machine, using a load cell of 100 kg (speed: 0.5 mm/min) and a specific device. The bond strength data were analyzed using ANOVA and Tukey's test (5%), and the failure modes were analyzed using an optical microscope (30x).Results: The means and standard deviations of the shear bond strengths were (MPa): G1 (57.97 +/- 11.34); G2 (40.62 +/- 12.96); G3 (47.09 +/- 13.19); and G4 (36.80 +/- 8.86). Ceramic (p = 0.03252) and surface treatment (p = 0.0002) significantly affected the mean bond strength values.Conclusions: Air-particle abrasion with Al(2)O(3) improved the shear bond strength between metal and ceramics used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The transmission of light through translucent posts was observed, and the microhardness of light-cured cement used to secure these posts was evaluated at different depths. Methods: Fifteen single-rooted standard bovine teeth, 16 mm in size, were used. The root canals were prepared using #3 drills Light-Post (five teeth) and Aestheti Post (five teeth) systems (BISCO), with a working-length of 12 mm. In five teeth, translucent posts were cemented (Light-Post #2), while another five teeth received opaque posts (Aestheti Post #2). The roots were painted with black nail varnish to prevent the passage of light through the lateral walls of the roots. The root canals of all the specimens were treated with the All-Bond 2 adhesive system (BISCO) and cemented with light-cured cement (Enforce, Dentsply). All the roots were transversally cut to obtain six specimens 1.5 mm thick. Every two sections corresponded to a specific region of the root (cervical, middle, apical), making it possible to observe the cement microhardness at different levels. The groups (n=10) were defined as: G1: translucent post (TP)/cervical region; G2: TP/middle region; G3: TP/apical region; G4: Opaque post (OP)/cervical region; G5: OP/middle region; G6: PO/apical region. Five root canals were only filled with cement for use as a control (G7). Then, Vickers microhardness analyses were performed. Results: In G3, G5 and G6, the cement was not sufficiently hard to allow for microhardness analysis. When submitted to the ANOVA test, G1 (35.07), G2 (24.28) and G4 (28.64) presented no statistical differences. When the previous groups were compared to G7 (51.00) using the Kruskal-Wallis test, a statistical difference was found. Conclusion: Translucent posts allow cement polymerization up to the middle portion of the root.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose:This study evaluated the microtensile bond strength of two resin cements to dentin either with their corresponding self-etching adhesives or employing the three-step etch-and-rinse technique. The null hypothesis was that the etch-and-rinse adhesive system would generate higher bond strengths than the self-etching adhesives.Materials and Methods:Thirty-two human molars were randomly divided into four groups (N = 32, n = 8/per group): G1) ED Primer self-etching adhesive + Panavia F; G2) All-Bond 2 etch-and-rinse adhesive + Panavia F; G3) Multilink primer A/B self-etching adhesive + Multilink resin cement; G4) All-Bond 2 + Multilink. After cementation of composite resin blocks (5 x 5 x 4 mm), the specimens were stored in water (37 degrees C, 24 hours), and sectioned to obtain beams (+/- 1 mm2 of adhesive area) to be submitted to microtensile test. The data were analyzed using 2-way analysis of variance and Tukey's test (alpha = 0.05).Results:Although the cement type did not significantly affect the results (p = 0.35), a significant effect of the adhesive system (p = 0.0001) was found on the bond strength results. Interaction terms were not significant (p = 0.88751). The etch-and-rinse adhesive provided significantly higher bond strength values (MPa) with both resin cements (G2: 34.4 +/- 10.6; G4: 33.0 +/- 8.9) compared to the self-etching adhesive systems (G1: 19.8 +/- 6.6; G3: 17.8 +/- 7.2) (p < 0.0001). Pretest failures were more frequent in the groups where self-etching systems were used.Conclusion:Although the cement type did not affect the results, there was a significant effect of changing the bonding strategy. The use of the three-step etch-and-rinse adhesive resulted in significantly higher bond strength for both resin cements on dentin.CLINICAL SIGNIFICANCEDual polymerized resin cements tested could deliver higher bond strength to dentin in combination with etch-and-rinse adhesive systems as opposed to their use in combination with self-etching adhesives.(J Esthet Restor Dent 22:262-269, 2010).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the cohesive strength of composite using self-etching adhesive systems (SE) in the lubrication of instruments between layers of composite. The specimens were made by using a Teflon (R) device. SE were used at the interface to lubricate the instruments: Group 1(G1) - control group, no lubricant was used; Group 2(G2) -Futurabond (R) M; Group 3(G3) - Optibond (R) All-In-One; Group 4(G4) - Clearfil (R) SE Bond; Group 5(G5) - Futurabond (R) NR; Group 6(G6) - Adper (R) SE Plus; Group 7(G7) - One Up Bond (R) F. Specimens were submitted to the tensile test to evaluate the cohesive strength. Data were submitted to the ANOVA and Tukey tests. ANOVA showed a value of p = 0.00. The average means (SD): G2 = 11.33(+/-3.44) a, G3 = 15.36(+/-4.06) ab, G4 = 18.9(+/-4.72) bc, G7 = 19.62(+/-4.46) bc, G5 = 21.02(+/-5.09) bc, G6 = 23.39(+/-4.17) cd, and G1 = 28.49(+/-2.89) d. All SE decreased the cohesive strength of the composite, except for Adper (R) SE Plus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the cohesive strength between composite and different light-curing characterizing materials (LCCM), which were prepared using the intrinsic technique.Materials and Methods: One hundred composite specimens were made by using a prefabricated Teflon device, and a layer of LCCM was applied at the interface. The specimens were divided into 5 groups (n = 20): group 1 (control), no LCCM was used; group 2: application of White Kolor Plus Pigment (Kerr) LCCM; group 3: White Tetric Color Pigment (Ivoclar/Vivadent) LCCM; group 4: Brown Kolor Plus Pigment (Kerr) LCCM; group 5: Black Tetric Color Pigment (Ivoclar/Vivadent) LCCM. All materials were used according to the manufacturers' instructions. Specimens were submitted to a tensile test in a universal testing machine (EMIC DL-200MF) to evaluate the cohesive strength at the composite interface. Data were subjected to one-way ANOVA and Tukey's test (alpha = 5%).Results: ANOVA showed a p-value = 0.0001, indicating that there were significant differences among the groups. The mean values in MPa (+/- standard deviation) obtained for the groups were: G1: 28.5 (+/-2.74)a; G2: 23.5 (+/-2.47)b; G3: 20.3 (+/-2.49)b; G4: 10.5 (+/-2.40)c; G5: 9.66 (+/-3.06)c. The groups with the same letters presented no significant differences. The control group presented statistically significantly higher cohesive strengths when compared to the other groups. The groups in which Brown Kolor Plus Pigment and Black Tetric Color Pigment LCCM were used showed significantly lower cohesive strengths when compared to the groups in which White Kolor Plus Pigment and White Tetric Color Pigment LCMM were used.Conclusion: The use of LCCM produced with the intrinsic technique reduced the cohesive strength of composite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. Material and methods. A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. Results. All groups showed significantly higher Delta E values than Group G1, with the exception of Group G8. Variations in the Delta E values at 14 days were significant when compared with those obtained at baseline and after 12 months. Conclusions. Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The objective of the present study was to evaluate a prefabricated intraradicular threaded pure titanium post, designed and developed at the Sao Jose dos Campos School of Dentistry - UNESP, Brazil. This new post was designed to minimize stresses observed with prefabricated post systems and to improve cost-benefits. Materials and and methods: Fracture resistance testing of the post/core/root complex, fracture analysis by microscopy and stress analysis by the finite element method were used for post evaluation. The following four prefabricated metal post systems were analyzed: group 1, experimental post; group 2, modification of the experimental post; group 3, Flexi Post, and group 4, Para Post. For the analysis of fracture resistance, 40 bovine teeth were randomly assigned to the four groups (n=10) and used for the fabrication of test specimens simulating the situation in the mouth. The test specimens were subjected to compressive strength testing until fracture in an EMIC universal testing machine. After fracture of the test specimens, their roots were sectioned and analyzed by microscopy. For the finite element method, specimens of the fracture resistance test were simulated by computer modeling to determine the stress distribution pattern in the post systems studied. Results: The fracture test presented the following averages and standard deviation: G1 (45.63 +/- 8.77), G2 (49.98 +/- 7.08), G3 (43.84 +/- 5.52), G4 (47.61 +/- 7.23). Stress was homogenously distributed along the body of the intraradicular post in group 1, whereas high stress concentrations in certain regions were observed in the other groups. These stress concentrations in the body of the post induced the same stress concentration in root dentin. Conclusions: The experimental post (original and modified versions) presented similar fracture resistance and better results in the stress analysis when compared with the commercial post systems tested (08/2008PA/CEP).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate, by scanning electronic microscopy (SEM), the cleaning of the root canal walls after instrumentation and irrigation with 2.5% sodium hypochlorite (NaOCl) associated with 2% chlorhexidine (CHX) gel or liquid, combined or not with 17% ethylenediamine tetra-acetic acid (EDTA).Study design. Sixty single-root human teeth were subjected to standardized root canal instrumentation with different irrigants (n = 10): G1) NaOCl + CHX liquid; G2) NaOCl + CHX liquid + EDTA + saline solution; G3) NaOCl + CHX gel; G4) NaOCl + CHX gel + EDTA + saline solution; G5) saline solution; G6) saline solution + EDTA. After instrumentation, the teeth were prepared for SEM analysis (x500 and x2,000) to evaluate the cleaning of the cervical, middle, and apical thirds. The area analyzed was quantified according to the percentage of open and closed tubules, and data were statistically analyzed by analysis of variance and Tukey tests (P = .05).Results. The number of open tubules was highest in G4 in all root thirds, showing statistically significant difference from G1, G2, and G5 (P < .05). G1 presented higher quantity of closed tubules significant than G2.Conclusion. Irrigation with NaOCl and CHX gel followed by EDTA and saline solution produced greater cleaning of the root canal walls. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e82-e87)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito do 5-fluorouracil (5FU) injetado intralesionalmente na cabeça do pterígio no período pré-operatório. MÉTODOS: Foram estudados 53 olhos (52 pacientes), sendo 28 pterígios primários e 25 recidivados, divididos em dois grupos: grupo 1 (G1), composto por indivíduos que receberam a injeção de 5-fluorouracil 30 dias antes do procedimento cirúrgico e grupo 2 (G2), no qual o 5-fluorouracil foi injetado 10 dias antes da cirurgia. Todas as cirurgias foram realizadas seguindo-se a mesma técnica cirúrgica, pelo mesmo cirurgião. Os pacientes foram reavaliados 7, 30 e 60 dias após a cirurgia. Os resultados observados foram submetidos à análise estatística. RESULTADOS: A amostra estudada foi constituída por 52,8% de pterígios primários e 47,2% de recidivados, sendo composta igualmente por indivíduos de ambos os sexos. Não ocorreram complicações decorrentes da infiltração da droga. A recidiva foi mais freqüente nos pterígios recidivados e no G1. CONCLUSÃO: O uso intralesional de 5-fluorouracil no pré-operatório do pterígio não provocou efeitos deletérios aos olhos estudados. Houve menor recorrência quando usado o 5-fluorouracil 10 dias antes da exérese cirúrgica, em relação à aplicação 30 dias antes do procedimento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Análise vocal acústica é método simples e rápido de avaliação vocal e permite diferenciar vozes normais de alteradas. em crianças, poucas pesquisas analisam os parâmetros vocais acústicos normais nas diversas idades. OBJETIVOS: Estabelecer parâmetros acústicos vocais de normalidade em crianças de 4 a 12 anos. CASUÍSTICA E MÉTODOS: 240 crianças distribuídas por idade em quatro subgrupos: G1 (n-60; 4-5 anos), G2 (n-60; 6-7 anos), G3 (n-60; 8-9 anos) e G4 (n-60; 10-12 anos). Os pais responderam um questionário de avaliação e as crianças foram submetidas à avaliação da acuidade auditiva (Pesquisa das Emissões Otoacústicas Transientes), às análises vocais acústicas e ao exame otorrinolaringológico (nasofibroscopia/ videolaringoscopia). RESULTADOS: Foram estabelecidos os valores normais dos parâmetros acústicos vocais estudados de acordo com as faixas etárias e o gênero. Com o aumento da idade, observou-se diminuição de f0 e do APQ e aumento do SPI com diferença estatística. Os parâmetros vocais não diferiram entre os gêneros até a idade de 12 anos. CONCLUSÕES: A caracterização dos padrões vocais normativos de crianças é importante ferramenta para outras pesquisas. Algumas das alterações constatadas mostraram relação com a idade como a diminuição de f0 e do APQ e aumento do SPI, sem haver diferença com relação ao gênero.