999 resultados para Fluxo de potência ótimo
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP
Resumo:
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA
Resumo:
This work describes the experimental implementation of a shunt active power filter applied to a three-phase induction generator. The control strategy of active filter turned to the excitation control of the machine and to decrease the harmonics in the generator output current. Involved the implementation of a digital PWM switching, and was made a comparison of two techniques for obtaining the reference currents. The first technique is based on the synchronous dq reference method and the second on the theory of instantaneous power. The comparison is performed via simulation and experimental results. To obtain the experimental results, was mounted a bench trial and the control and communications needed were implemented using DSP - MS320F2812. The simulation results and experimental data proved the efficiency of the filter to apply, highlighting the technique of instantaneous power
Resumo:
This work presents a description of models development at DigSILENT PowerFactoryT M program for the transient stability study in power systems with wind turbine. The main goal is to make available means to use a dynamic simulation program in power systems, widely published, and utilize it as a tool that helps in programs results evaluations used for this intent. The process of simulations and analyses results starts after the models setting description phase. The results obtained by the DigSILENT PowerFactoryT M and ATP, program chosen to the validation also international recognized, are compared during this phase. The main tools and guide lines of PowerFactoryT M program use are presented here, directing these elements to the solution of the approached problem. For the simulation it is used a real system which it will be connected a wind farm. Two different technologies of wind turbines were implemented: doublyfed induction generator with frequency converter, connecting the rotor to the stator and to the grid, and synchronous wind generator with frequency converter, interconnecting the generator to the grid. Besides presenting the basic conceptions of dynamic simulation, it is described the implemented control strategies and models of turbine and converters. The stability of the wind turbine interconnected to grid is analyzed in many operational conditions, resultant of diverse kinds of disturbances
Resumo:
This work presents a description of models development at DigSILENT PowerFactoryTM program for the transient stability study in power systems with wind turbine. The main goal is to make available means to use a dynamic simulation program in power systems, widely published, and utilize it as a tool that helps in programs results evaluations used for this intent. The process of simulations and analyses results starts after the models setting description phase. The results obtained by the DigSILENT PowerFactoryTM and ATP, program chosen to the validation also international recognized, are compared during this phase. The main tools and guide lines of PowerFactoryTM program use are presented here, directing these elements to the solution of the approached problem. For the simulation it is used a real system which it will be connected a wind farm. Two different technologies of wind turbines were implemented: doubly-fed induction generator with frequency converter, connecting the rotor to the stator and to the grid, and synchronous wind generator with frequency converter, interconnecting the generator to the grid. Besides presenting the basic conceptions of dynamic simulation, it is described the implemented control strategies and models of turbine and converters. The stability of the wind turbine interconnected to grid is analyzed in many operational conditions, resultant of diverse kinds of disturbances
Resumo:
The power system stabilizers are used to suppress low-frequency electromechanical oscillations and improve the synchronous generator stability limits. This master thesis proposes a wavelet-based power system stabilizer, composed of a new methodology for extraction and compensation of electromechanical oscillations in electrical power systems based on the scaling coefficient energy of the maximal overlap discrete wavelet transform in order to reduce the effects of delay and attenuation of conventional power system stabilizers. Moreover, the wavelet coefficient energy is used for electric oscillation detection and triggering the power system stabilizer only in fault situations. The performance of the proposed power system stabilizer was assessed with experimental results and comparison with the conventional power system stabilizer. Furthermore, the effects of the mother wavelet were also evaluated in this work
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The scarcity of natural resources and the search for alternative energy sources promote a rapid change in the energy world. Among the renewable energy sources, solar energy is the most promising, presenting technology of greatest growth rate nowadays. Researchers around the world are seeking ways to facilitate their progress, developing technologies with higher efficiency and lower cost. As a contribution to global progress, this master thesis proposes the development of a strategy of maximum power tracking based on perturbation and observation method for photovoltaic systems. The proposed control strategy is based on active power balance of the system, with a reduced number of sensors. It also allows the PV system to act as a regulator of the power quality at the point of commom coupling (PCC), compensating the harmonic distortion and power factor of the current netw
Resumo:
The use of Field Programmable Gate Array (FPGA) for development of digital control strategies for power electronics applications has aroused a growing interest of many researchers. This interest is due to the great advantages offered by FPGA, which include: lower design effort, high performance and highly flexible prototyping. This work proposes the development and implementation of an unified one-cycle controller for boost CFP rectifier based on FPGA. This controller can be applied to a total of twelve converters, six inverters and six rectifiers defined by four single phase VSI topologies and three voltage modulation types. The topologies considered in this work are: full-bridge, interleaved full-bridge, half-bridge and interleaved half-bridge. While modulations are classified in bipolar voltage modulation (BVM), unipolar voltage modulation (UVM) and clamped voltage modulation (CVM). The proposed project is developed and prototyped using tools Matlab/Simulink® together with the DSP Builder library provided by Altera®. The proposed controller was validated with simulation and experimental results
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Composites based on PEEK + PTFE + CARBON FIBER + Graphite (G_CFRP) has increased application in the top industries, as Aerospace, Aeronautical, Petroleum, Biomedical, Mechanical and Electronics Engineering challenges. A commercially available G_CFRP was warmed up to three different levels of thermal energy to identify the main damage mechanisms and some evidences for their intrinsic transitions. An experimental test rig for systematize a heat flux was developed in this dissertation, based on the Joule Effect. It was built using an isothermal container, an internal heat source and a real-time measurement system for test a sample by time. A standard conical-cylindrical tip was inserted into a soldering iron, commercially available and identified by three different levels of nominal electrical power, 40W (manufacturer A), 40W (manufacturer B), 100W and 150W, selected after screening tests: these power levels for the heat source, after one hour of heating and one hour of cooling in situ, carried out three different zones of degradation in the composite surface. The bench was instrumented with twelve thermocouples, a wattmeter and a video camera. The twelve specimens tested suffered different degradation mechanisms, analyzed by DSC (Differential Scanning Calorimetry) and TG (Thermogravimetry) techniques, Scanning Electron Microscopy (SEM) and Energy-Dispersive X-Rays (EDX) Analysis. Before and after each testing, it was measured the hardness of the sample by HRM (Hardness Rockwell M). Excellent correlations (R2=1) were obtained in the plots of the evaporated area after one hour of heating and one hour of cooling in situ versus (1) the respective power of heat source and (2) the central temperature of the sample. However, as resulting of the differential degradation of G_CFRP and their anisotropy, confirmed by their variable thermal properties, viscoelastic and plastic properties, there were both linear and non-linear behaviour between the temperature field and Rockwell M hardness measured in the radial and circumferential directions of the samples. Some morphological features of the damaged zones are presented and discussed, as, for example, the crazing and skeletonization mechanism of G_CFRP
Resumo:
Experiments were performed to study the effect of surface properties of a vertical channel heated by a source of thermal radiation to induce air flow through convection. Two channels (solar chimney prototype) were built with glass plates, forming a structure of truncated pyramidal geometry. We considered two surface finishes: transparent and opaque. Each stack was mounted on a base of thermal energy absorber with a central opening for passage of air, and subjected to heating by a radiant source comprises a bank of incandescent bulbs and were performed field tests. Thermocouples were fixed on the bases and on the walls of chimneys and then connected to a data acquisition system in computer. The air flow within the chimney, the speed and temperature were measured using a hot wire anemometer. Five experiments were performed for each stack in which convective flows were recorded with values ranging from 17 m³ / h and 22 m³ / h and air flow velocities ranging from 0.38 m / s and 0.56 m / s for the laboratory tests and air velocities between 0.6 m/s and 1.1m/s and convective airflows between 650 m³/h and 1150 m³/h for the field tests. The test data were compared to those obtained by semi-empirical equations, which are valid for air flow induced into channels and simulated data from 1st Thermodynamics equation. It was found that the chimney with transparent walls induced more intense convective flows than the chimney with matte finish. Based on the results obtained can be proposed for the implementation of prototype to exhaust fumes, mists, gases, vapors, mists and dusts in industrial environments, to help promote ventilation and air renewal in built environments and for drying materials, fruits and seeds
Resumo:
A lagarta Anticarsia gemmatalis (Hübner) e os percevejos fitófagos são pragas importantes na cultura da soja no Brasil. Este trabalho objetivou avaliar o controle desses insetos após o tratamento com inseticidas, sob diferentes velocidades do fluxo de ar junto à barra de pulverização nessa cultura. O experimento foi desenvolvido em Botucatu, na cultura da soja [Glycine max (L.) Merrill], var. Conquista (safra 2007/08), no delineamento experimental de blocos ao acaso (quatro velocidades do fluxo de ar: 0, 9, 11 e 29 km h-1), mais testemunha, totalizando cinco tratamentos e quatro repetições. No estádio de desenvolvimento vegetativo (V10) realizou uma aplicação do inseticida deltametrina na dosagem de 6,5 g do i.a. ha-1 para o controle de lagartas e no estádio de desenvolvimento reprodutivo (R6) aplicou o inseticida tiametoxam associado com lambda-cialotrina na dosagem de 25,38 + 19,08 g do i.a. ha-1 para o controle de percevejos. A aplicação foi feita com um pulverizador Advanced Vortex 2000, com pontas de pulverização jato cônico JA2, conferindo um volume de calda de 200 L ha-1. As avaliações antes e após a aplicação foram realizadas pelo método de batidas no pano. Avaliaram-se os danos causados por percevejos, considerando-se a porcentagem de danos às sementes, ao poder germinativo e à produtividade. No geral, o número médio de lagartas e percevejos foram significativamente menores nas parcelas tratadas em relação ao obtido na testemunha. Não houve diferença de produtividade entre os tratamentos. A porcentagem de emergência e sementes picadas por percevejos foram significativamente menores nos tratamentos que receberam o controle em comparação à testemunha.
Resumo:
O cultivo consorciado entre a espécie forrageira e a cultura produtora de grãos garante a produção de forragem no outono-inverno, além de palha para cobertura do solo em sistema semeadura direta. O aporte de matéria seca radicular no perfil do solo possibilita a melhoria da qualidade estrutural do solo. Objetivou-se com este experimento verificar as alterações nos atributos físicos e físico-hídricos do solo com o cultivo de milho solteiro e consorciado com Brachiaria brizantha. O experimento foi conduzido na Fazenda Experimental Lageado (UNESP, Botucatu-SP), entre os anos agrícolas de 2002/2003 e 2003/2004. Foram coletadas amostras com estrutura preservada de solo, por meio de anéis volumétricos, nas camadas de 0 a 20 e 20 a 40 cm de profundidade, em trincheiras abertas em parcelas cultivadas com milho e mantidas em pousio na entressafra, bem como em parcelas cultivadas com milho consorciado com B. brizantha na linha de semeadura, mantendo a forrageira para pastagem após a colheita do milho. A partir dessas amostras, foi avaliado o Intervalo Hídrico Ótimo (IHO), por meio de curvas de resistência à penetração e de retenção de água, em amostras com diferentes densidades do solo. O cultivo solteiro de milho na safra de verão é suficiente para melhorar as características físicas e estruturais do solo na camada de 0 a 20 cm. O cultivo de braquiária em consórcio com o milho por dois anos consecutivos melhora as condições físicas e estruturais do solo na camada de 20 a 40 cm, com redução da resistência mecânica à penetração e aumento da densidade crítica do solo.
Resumo:
Este projeto teve por objetivo avaliar a eficácia de herbicidas para controle de plantas aquáticas submersas das espécies Egeria densa e Egeria najas. O estudo foi realizado em três etapas consecutivas: em laboratório, em caixas d'água e numa represa de pequeno porte, sem fluxo de água. Na primeira etapa, avaliou-se a eficiência de 23 herbicidas utilizados em áreas agrícolas e disponíveis no mercado brasileiro. As elevadas concentrações em que os herbicidas foram efetivos inviabilizam programas de controle fundamentados em uma única aplicação. No experimento em caixas d'água, foram avaliados os efeitos de doses crescentes de fluridone, nas formulações líquida e granulada, no controle de Egeria densa e Egeria najas. Foram testadas as concentrações de 10, 20, 40, 80 e 150 ppb de fluridone na formulação líquida e 20, 40, 80 e 150 ppb na granulada. Após uma única aplicação, os resultados indicaram que o fluridone, nas concentrações de 80 e 150 ppb, em ambas as formulações, foi eficaz no controle dessas duas espécies. No experimento em represa de pequeno porte sem fluxo de água, avaliou-se o efeito da manutenção das concentrações de fluridone no controle de Egeria najas. Uma represa de 1.980 m² foi tratada com sete aplicações de fluridone, na formulação líquida, visando a manutenção das concentrações do ingrediente ativo na água entre 10 e 20 ppb. Os resultados indicaram que o controle proporcionado pelo herbicida foi superior a 99%. Não houve modificação significativa nas características relacionadas à qualidade da água.