1000 resultados para Estabilidade dimensional
Resumo:
Compared to synthetic aperture radars (SARs), the angular resolution of microwave radiometers is quite poor. Traditionally, it has been limited by the physical size of the antenna. However, the angular resolution can be improved by means of aperture synthesis interferometric techniques. A narrow beam is synthesized during the image formation processing of the cross-correlations measured at zero-lag between pairs of signals collected by an array of antennas. The angular resolution is then determined by the maximum antenna spacing normalized to the wavelength (baseline). The next step in improving the angular resolution is the Doppler-Radiometer, somehow related to the super-synthesis radiometers and the Radiometer-SAR. This paper presents the concept of a three-antenna Doppler-Radiometer for 2D imaging. The performance of this instrument is evaluated in terms of angular/spatial resolution and radiometric sensitivity, and an L-band illustrative example is presented.
Resumo:
The purpose of this study is to clinically validate a new two-dimensional preoperative planning software for cementless total hip arthroplasty (THA). Manual and two-dimensional computer-assisted planning were compared by an independent observer for each of the 30 patients with osteoarthritis who underwent THA. This study showed that there were no statistical differences between the results of both preoperative plans in terms of stem size and neck length (<1 size) and hip rotation center position (<5 mm). Two-dimensional computer-assisted preoperative planning provided successful results comparable to those using the manual procedure, thereby allowing the surgeon to simulate various stem designs easily.
Resumo:
This work is devoted to the problem of reconstructing the basis weight structure at paper web with black{box techniques. The data that is analyzed comes from a real paper machine and is collected by an o®-line scanner. The principal mathematical tool used in this work is Autoregressive Moving Average (ARMA) modelling. When coupled with the Discrete Fourier Transform (DFT), it gives a very flexible and interesting tool for analyzing properties of the paper web. Both ARMA and DFT are independently used to represent the given signal in a simplified version of our algorithm, but the final goal is to combine the two together. Ljung-Box Q-statistic lack-of-fit test combined with the Root Mean Squared Error coefficient gives a tool to separate significant signals from noise.
Resumo:
Diplomityön tarkoituksena on kehittää kolmiulotteinen malli kerrosleijupoltolle. Työn kirjallisuusosa sisältää seuraavat perusteet kerrosleijupolton tekniikasta: yleistiedot, leijutus- ja palamisilmiöt, kiinteän aineen ja kaasun sekoittuminen, päästöt ja lämmönsiirto. Lisäksi palamissysteemin mallinnuksen perusteet ja ratkaisumenetelmät ovat esitelty. Työn mallinnusosassa kehitetty koodi on ohjelmoitu Fortran-ohjelmointikielellä. Kehitetty malli perustuu olemassa olevaan malliin kiertoleijupoltosta. Yhtälö kiintoainekonsentraatioprofiilille on vaihdettu ja kiertovirta on poistettu koodista. Mallilla on tehty herkkyystarkasteluja polttoaineen ja kaasun sekoittumisen sekä reaktiokertoimen vaikutukselle. Visualisointi on tehty ohjelmassa Tecplot 360 ja mallinnustuloksia on vertailtu mitattuihin tuloksiin. Mallin laskemattulokset vastaavat hyvin mittaustuloksia ja kokemusperäisiä tietoja; monissa tapauksissa malli pystyy kvantitatiivisesti kuvaamaan parametrien variointia ja kaikissa tapauksissa malli antaa ainakin kvalitatiivisesti oikeita tuloksia. Työhön liittyvän kehityksen ja mallinnuskokemuksen perusteella on tehty ehdotukset mallin tulevaa kehitystä ja mittauksia varten.
Resumo:
O objetivo deste trabalho foi desenvolver e validar uma metodologia de análise da adaptabilidade e da estabilidade fenotípica baseada em regressão quantílica (RQ). Para tanto, foram simulados valores fenotípicos com distribuição simétrica e com distribuição assimétrica à direita e à esquerda, com ou sem a presença de "outliers". A metodologia proposta foi aplicada a um conjunto de dados provenientes de um experimento com 92 genótipos de alfafa (Medicago sativa), avaliados em 20 ambientes, e comparada às metodologias de Eberhart & Russell e de regressão não paramétrica. A metodologia da RQ proporcionou resultados iguais ou superiores aos obtidos com as metodologias alternativas avaliadas. No entanto, a ocorrência de resultados discordantes entre as metodologias evidencia a importância de se avaliar a simetria na distribuição dos valores fenotípicos. Para distribuições simétricas, na presença de "outliers", deve-se utilizar a RQ com valor de quantil estimado (τ) em 0,50; na ausência de "outliers", pode-se utilizar tanto a metodologia de Eberhart & Russell quanto a RQ (τ = 0,50). Para distribuições assimétricas, indica-se o uso da RQ com τ = 0,25, para assimetria à direita, e com τ = 0,75, para assimetria à esquerda, independentemente da presença de "outliers".
Resumo:
Resumo:O objetivo deste trabalho foi avaliar a resistência de genótipos de feijoeiro aos principais patógenos da cultura, bem como a adaptabilidade e a estabilidade de produção de grãos desses genótipos. Avaliaram-se 26 genótipos de feijoeiro quanto à resistência a Colletotrichum lindemuthianum, Fusarium oxysporum f. sp. phaseolie Xanthomonas axonopodis pv. phaseoli, por meio de inoculação, em laboratório, e em 19 ensaios de valor de cultivo e uso (VCU), em diferentes locais do Estado de São Paulo, nas safras das "águas", "seca" e "inverno", durante os anos agrícolas 2011, 2012 e 2013. Dezoito genótipos foram considerados resistentes: sete deles a C. lindemuthianum, sete a F. oxysporumf. sp. phaseolie quatro a X. axonopodispv. phaseoli. A reação de resistência aos patógenos está associada à estabilidade dos genótipos. Por meio das análises GGE biplot, foi possível identificar genótipos com adaptabilidade e estabilidade superiores às das testemunhas, nos dois grupos de tegumento avaliados, em todas as épocas de semeadura.
Resumo:
Resumo: O objetivo deste trabalho foi verificar a concordância entre as redes neurais artificiais (RNAs) e o método de Eberhart & Russel na identificação de genótipos de feijão-caupi (Vigna unguiculata) com alta adaptabilidade e estabilidade fenotípicas. Utilizou-se o delineamento experimental de blocos ao acaso com quatro repetições. Os tratamentos consistiram de 18 linhagens experimentais e duas cultivares de feijão-caupi. Foram conduzidos quatro ensaios de valor de cultivo e uso nos municípios de Aquidauana, Chapadão do Sul e Dourados, no estado do Mato Grosso do Sul. Os dados de produtividade de grãos foram submetidos às análises de variância individual e conjunta. Em seguida, os dados foram submetidos às análises de adaptabilidade e estabilidade por meio dos métodos de Eberhart & Russell e de RNAs. Houve elevada concordância entre os métodos avaliados quanto à discriminação da adaptabilidade fenotípica dos genótipos de feijão-caupi semiprostrado, o que indica que as RNAs podem ser utilizadas em programas de melhoramento genético. Em ambos os métodos avaliados, os genótipos BRS Xiquexique, TE97-304G-12 e MNC99-542F-5 são recomendados para ambientes desfavoráveis, gerais e favoráveis, respectivamente, por apresentarem produtividade de grãos acima da média geral dos ambientes e alta estabilidade fenotípica.
Resumo:
The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.
Resumo:
Resumo: O objetivo deste trabalho foi determinar a adaptabilidade e a estabilidade de clones de cana-de-açúcar ( Saccharum spp.) de ciclo médio-tardio, quanto à produção de colmos e de açúcar, e a eficiência da conversão de energia solar em produção, na região Noroeste do Estado do Rio Grande do Sul. Treze clones foram avaliados em nove ambientes, em delineamento de blocos ao acaso, com três repetições. As variáveis utilizadas para a análise de efeitos principais aditivos e interações multiplicativas (AMMI) foram: a produtividade de colmos e de açúcar, e a eficiência da conversão de energia solar em produção. Houve interação entre clones e ambientes, e o clone RB996527 destacou-se por ampla adaptação aos ambientes de teste, elevada produtividade de colmos e açúcar, estabilidade e eficiência da conversão de energia solar em produção, tendo superado a testemunha RB867515. Os ambientes com maior produtividade foram São Luiz Gonzaga (primeira-soca) e Santa Rosa (cana-planta e primeira-soca).
Resumo:
In this article we propose a novel method for calculating cardiac 3-D strain. The method requires the acquisition of myocardial short-axis (SA) slices only and produces the 3-D strain tensor at every point within every pair of slices. Three-dimensional displacement is calculated from SA slices using zHARP which is then used for calculating the local displacement gradient and thus the local strain tensor. There are three main advantages of this method. First, the 3-D strain tensor is calculated for every pixel without interpolation; this is unprecedented in cardiac MR imaging. Second, this method is fast, in part because there is no need to acquire long-axis (LA) slices. Third, the method is accurate because the 3-D displacement components are acquired simultaneously and therefore reduces motion artifacts without the need for registration. This article presents the theory of computing 3-D strain from two slices using zHARP, the imaging protocol, and both phantom and in-vivo validation.
Resumo:
Ochratoxin A (OTA), a fungal contaminant of basic food commodities, is known to be highly cytotoxic, but the pathways underlying adverse effects at subcytotoxic concentrations remain to be elucidated. Recent reports indicate that OTA affects cell cycle regulation. Therefore, 3D brain cell cultures were used to study OTA effects on mitotically active neural stem/progenitor cells, comparing highly differentiated cultures with their immature counterparts. Changes in the rate of DNA synthesis were related to early changes in the mRNA expression of neural stem/progenitor cell markers. OTA at 10nM, a concentration below the cytotoxic level, was ineffective in immature cultures, whereas in mature cultures it significantly decreased the rate of DNA synthesis together with the mRNA expression of key transcriptional regulators such as Sox2, Mash1, Hes5, and Gli1; the cell cycle activator cyclin D2; the phenotypic markers nestin, doublecortin, and PDGFRα. These effects were largely prevented by Sonic hedgehog (Shh) peptide (500ngml(-1)) administration, indicating that OTA impaired the Shh pathway and the Sox2 regulatory transcription factor critical for stem cell self-renewal. Similar adverse effects of OTA in vivo might perturb the regulation of stem cell proliferation in the adult brain and in other organs exhibiting homeostatic and/or regenerative cell proliferation.
Resumo:
Les échantillons biologiques ne s?arrangent pas toujours en objets ordonnés (cristaux 2D ou hélices) nécessaires pour la microscopie électronique ni en cristaux 3D parfaitement ordonnés pour la cristallographie rayons X alors que de nombreux spécimens sont tout simplement trop << gros D pour la spectroscopie NMR. C?est pour ces raisons que l?analyse de particules isolées par la cryo-microscopie électronique est devenue une technique de plus en plus importante pour déterminer la structure de macromolécules. Néanmoins, le faible rapport signal-sur-bruit ainsi que la forte sensibilité des échantillons biologiques natifs face au faisceau électronique restent deux parmi les facteurs limitant la résolution. La cryo-coloration négative est une technique récemment développée permettant l?observation des échantillons biologiques avec le microscope électronique. Ils sont observés à l?état vitrifié et à basse température, en présence d?un colorant (molybdate d?ammonium). Les avantages de la cryo-coloration négative sont étudiés dans ce travail. Les résultats obtenus révèlent que les problèmes majeurs peuvent êtres évités par l?utilisation de cette nouvelle technique. Les échantillons sont représentés fidèlement avec un SNR 10 fois plus important que dans le cas des échantillons dans l?eau. De plus, la comparaison de données obtenues après de multiples expositions montre que les dégâts liés au faisceau électronique sont réduits considérablement. D?autre part, les résultats exposés mettent en évidence que la technique est idéale pour l?analyse à haute résolution de macromolécules biologiques. La solution vitrifiée de molybdate d?ammonium entourant l?échantillon n?empêche pas l?accès à la structure interne de la protéine. Finalement, plusieurs exemples d?application démontrent les avantages de cette technique nouvellement développée.<br/><br/>Many biological specimens do not arrange themselves in ordered assemblies (tubular or flat 2D crystals) suitable for electron crystallography, nor in perfectly ordered 3D crystals for X-ray diffraction; many other are simply too large to be approached by NMR spectroscopy. Therefore, single-particles analysis has become a progressively more important technique for structural determination of large isolated macromolecules by cryo-electron microscopy. Nevertheless, the low signal-to-noise ratio and the high electron-beam sensitivity of biological samples remain two main resolution-limiting factors, when the specimens are observed in their native state. Cryo-negative staining is a recently developed technique that allows the study of biological samples with the electron microscope. The samples are observed at low temperature, in the vitrified state, but in presence of a stain (ammonium molybdate). In the present work, the advantages of this novel technique are investigated: it is shown that cryo-negative staining can generally overcome most of the problems encountered with cryo-electron microscopy of vitrified native suspension of biological particles. The specimens are faithfully represented with a 10-times higher SNR than in the case of unstained samples. Beam-damage is found to be considerably reduced by comparison of multiple-exposure series of both stained and unstained samples. The present report also demonstrates that cryo-negative staining is capable of high- resolution analysis of biological macromolecules. The vitrified stain solution surrounding the sample does not forbid the access to the interna1 features (ie. the secondary structure) of a protein. This finding is of direct interest for the structural biologist trying to combine electron microscopy and X-ray data. developed electron microscopy technique. Finally, several application examples demonstrate the advantages of this newly
Resumo:
O presente trabalho teve por objetivo avaliar a estabilidade de melões desidratados obtidos por desidratação osmótica à pressão atmosférica (760 mmHg) e a vácuo parcial (660 mmHg) seguida de secagem convencional. A estabilidade dos produtos foi avaliada segundo suas características físico-químicas, microbiológicas e sensoriais, durante 180 dias de armazenamento, à temperatura ambiente. Ambos os processos resultaram em boa estabilidade físico-química e microbiológica dos produtos que mostraram boa aceitação durante todo o período de armazenamento.
Resumo:
PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.
Resumo:
PURPOSE: To implement and characterize an isotropic three-dimensional cardiac T2 mapping technique. METHODS: A self-navigated three-dimensional radial segmented balanced steady-state free precession pulse sequence with an isotropic 1.7-mm spatial resolution was implemented at 3T with a variable T2 preparation module. Bloch equation and Monte Carlo simulations were performed to determine the influence of the heart rate, B1 inhomogeneity and noise on the T2 fitting accuracy. In a phantom study, the accuracy of the pulse sequence was studied through comparison with a gold-standard spin-echo T2 mapping method. The robustness and homogeneity of the technique were ascertained in a study of 10 healthy adult human volunteers, while first results obtained in patients are reported. RESULTS: The numerical simulations demonstrated that the heart rate and B1 inhomogeneity cause only minor deviations in the T2 fitting, whereas the phantom study showed good agreement of the technique with the gold standard. The volunteer study demonstrated an average myocardial T2 of 40.5 ± 3.3 ms and a <15% T2 gradient in the base-apex and anterior-inferior direction. In three patients, elevated T2 values were measured in regions with expected edema. CONCLUSION: This respiratory self-navigated isotropic three-dimensional technique allows for accurate and robust in vitro and in vivo T2 quantification. Magn Reson Med 73:1549-1554, 2015. © 2014 Wiley Periodicals, Inc.