890 resultados para Electrical load
Resumo:
Salvador (BA, Brazil) is an endemic area for human T-cell lymphotrophic virus type 1 (HTLV-1). The overall prevalence of HTLV-1 infection in the general population has been estimated to be 1.76%. HTLV-1 carriers may develop a variety of diseases such as adult T-cell leukemia/lymphoma, HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and infective dermatitis associated with HTLV-1 (IDH). IDH is a chronic and severe form of childhood exudative and infective dermatitis involving mainly the scalp, neck and ears. It has recently been observed that 30% of patients with IDH develop juvenile HAM/TSP. The replication of HTLV-1 has been reported to be greater in adult HAM/TSP patients than in asymptomatic HTLV-1 carriers. In the current study, the proviral load of 28 children and adolescents with IDH not associated with HAM/TSP was determined and the results were compared to those obtained in 28 HTLV-1 adult carriers and 28 adult patients with HAM/TSP. The proviral load in IDH patients was similar to that of patients with HAM/TSP and much higher than that found in HTLV-1 carriers. The high levels of proviral load in IDH patients were not associated with age, duration of illness, duration of breast-feeding, or activity status of the skin disease. Since proviral load is associated with neurological disability, these data support the view that IDH patients are at high risk of developing HAM/TSP.
Resumo:
Transcutaneous electrical nerve stimulation (TENS) is a type of therapy used primarily for analgesia, but also presents changes in the cardiovascular system responses; its effects are dependent upon application parameters. Alterations to the cardiovascular system suggest that TENS may modify venous vascular response. The objective of this study was to evaluate the effects of TENS at different frequencies (10 and 100 Hz) on venous vascular reactivity in healthy subjects. Twenty-nine healthy male volunteers were randomized into three groups: placebo (n=10), low-frequency TENS (10 Hz, n=9) and high-frequency TENS (100 Hz, n=10). TENS was applied for 30 min in the nervous plexus trajectory from the superior member (from cervical to dorsal region of the fist) at low (10 Hz/200 μs) and high frequency (100 Hz/200 μs) with its intensity adjusted below the motor threshold and intensified every 5 min, intending to avoid accommodation. Venous vascular reactivity in response to phenylephrine, acetylcholine (endothelium-dependent) and sodium nitroprusside (endothelium-independent) was assessed by the dorsal hand vein technique. The phenylephrine effective dose to achieve 70% vasoconstriction was reduced 53% (P<0.01) using low-frequency TENS (10 Hz), while in high-frequency stimulation (100 Hz), a 47% increased dose was needed (P<0.01). The endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) responses were not modified by TENS, which modifies venous responsiveness, and increases the low-frequency sensitivity of α1-adrenergic receptors and shows high-frequency opposite effects. These changes represent an important vascular effect caused by TENS with implications for hemodynamics, inflammation and analgesia.
Resumo:
Heterotopic ossification (HO) is a metaplastic biological process in which there is newly formed bone in soft tissues, resulting in joint mobility deficit and pain. Different treatment modalities have been tried to prevent HO development, but there is no consensus on a therapeutic approach. Since electrical stimulation is a widely used resource in physiotherapy practice to stimulate joint mobility, with analgesic and anti-inflammatory effects, its usefulness for HO treatment was investigated. We aimed to identify the influence of electrical stimulation on induced HO in Wistar rats. Thirty-six male rats (350-390 g) were used, and all animals were anesthetized for blood sampling before HO induction, to quantify the serum alkaline phosphatase. HO induction was performed by bone marrow implantation in both quadriceps of the animals, which were then divided into 3 groups: control (CG), transcutaneous electrical nerve stimulation (TENS) group (TG), and functional electrical stimulation (FES) group (FG) with 12 rats each. All animals were anesthetized and electrically stimulated twice per week, for 35 days from induction day. After this period, another blood sample was collected and quadriceps muscles were bilaterally removed for histological and calcium analysis and the rats were killed. Calcium levels in muscles showed significantly lower results when comparing TG and FG (P<0.001) and between TG and CG (P<0.001). Qualitative histological analyses confirmed 100% HO in FG and CG, while in TG the HO was detected in 54.5% of the animals. The effects of the muscle contractions caused by FES increased HO, while anti-inflammatory effects of TENS reduced HO.
Resumo:
The growing population in cities increases the energy demand and affects the environment by increasing carbon emissions. Information and communications technology solutions which enable energy optimization are needed to address this growing energy demand in cities and to reduce carbon emissions. District heating systems optimize the energy production by reusing waste energy with combined heat and power plants. Forecasting the heat load demand in residential buildings assists in optimizing energy production and consumption in a district heating system. However, the presence of a large number of factors such as weather forecast, district heating operational parameters and user behavioural parameters, make heat load forecasting a challenging task. This thesis proposes a probabilistic machine learning model using a Naive Bayes classifier, to forecast the hourly heat load demand for three residential buildings in the city of Skellefteå, Sweden over a period of winter and spring seasons. The district heating data collected from the sensors equipped at the residential buildings in Skellefteå, is utilized to build the Bayesian network to forecast the heat load demand for horizons of 1, 2, 3, 6 and 24 hours. The proposed model is validated by using four cases to study the influence of various parameters on the heat load forecast by carrying out trace driven analysis in Weka and GeNIe. Results show that current heat load consumption and outdoor temperature forecast are the two parameters with most influence on the heat load forecast. The proposed model achieves average accuracies of 81.23 % and 76.74 % for a forecast horizon of 1 hour in the three buildings for winter and spring seasons respectively. The model also achieves an average accuracy of 77.97 % for three buildings across both seasons for the forecast horizon of 1 hour by utilizing only 10 % of the training data. The results indicate that even a simple model like Naive Bayes classifier can forecast the heat load demand by utilizing less training data.
Resumo:
With the new age of Internet of Things (IoT), object of everyday such as mobile smart devices start to be equipped with cheap sensors and low energy wireless communication capability. Nowadays mobile smart devices (phones, tablets) have become an ubiquitous device with everyone having access to at least one device. There is an opportunity to build innovative applications and services by exploiting these devices’ untapped rechargeable energy, sensing and processing capabilities. In this thesis, we propose, develop, implement and evaluate LoadIoT a peer-to-peer load balancing scheme that can distribute tasks among plethora of mobile smart devices in the IoT world. We develop and demonstrate an android-based proof of concept load-balancing application. We also present a model of the system which is used to validate the efficiency of the load balancing approach under varying application scenarios. Load balancing concepts can be apply to IoT scenario linked to smart devices. It is able to reduce the traffic send to the Cloud and the energy consumption of the devices. The data acquired from the experimental outcomes enable us to determine the feasibility and cost-effectiveness of a load balanced P2P smart phone-based applications.
Resumo:
F/A-18-monitoimihävittäjän ohjaajan tehtävän kognitiiviset vaatimukset ovat korkeat. Kognitiivisen kuormituksen taso vaikuttaa hävittäjäohjaajan suoritustasoon ja subjektiivisiin tun-temuksiin. Yerkesin ja Dodsonin periaatteen mukaisesti erittäin matala tai erittäin korkea kuormituksen taso laskee suoritustasoa. Optimaalinen kuormituksen taso ja suoritustaso saa-vutetaan jossain ääripäiden välillä. Hävittäjäohjaajan kognitiivisen kuormituksen tasoon vaikuttaa lentotehtävän suorittamiseen vaadittava henkinen ponnistelu. Vaadittavan ponnistelun taso riippuu tehtävien vaatimustasosta ja määrästä, tehtäviin käytettävissä olevasta ajasta sekä yksilöllisistä ominaisuuksista. Tutkimuksessa mitattiin kognitiivisen kuormituksen tasoa subjektiivisen arvioinnin menetelmällä NASA-TLX (National Aeronautics and Space Administration - Task Load Index) ja MCH (Modified Cooper-Harper) -mittareilla. Tutkimuksessa selvitettiin mittareiden havaintoarvojen muutosta, sensitiivisyyttä ja yhdenmukaisuutta kognitiivisen kuormituksen tason muuttuessa. Tutkimuksen mittauksiin osallistui 35 Suomen ilmavoimien aktiivisessa palveluksessa olevaa F/A-18-monitoimihävittäjäohjaajaa. Koehenkilöiden lentotuntien keskiarvo F/A-18-monitoimihävittäjällä oli 598 tuntia ja keskihajonta 445 tuntia. Koehenkilöiden tehtävänä oli lentää F/A-18-virtuaalisimulaattorilla 11 ILS (Instrument Landing System) -mittarilähestymistä eri aloitusetäisyyksiltä kiitotien kynnyksestä. Kognitiivisesti kuormitta-van mittarilähestymistehtävän aikana kuormituksen tasoa nostettiin lisätehtävillä ja vähentä-mällä tehtäviin käytettävissä olevaa aikaa. Koehenkilöitä pyydettiin ponnistelemaan mahdollisimman paljon tehtävien suorittamisen aikana hyvän suoritustason ylläpitämiseksi. Tulosten perusteella mittareiden havaintoarvot muuttuivat kognitiivisen kuormituksen tason muuttuessa. Käytettävissä olevan ajan vaikutus kognitiivisen kuormituksen tasoon oli tilastollisesti erittäin merkitsevä. Mittarit olivat sensitiivisiä kognitiivisen kuormituksen tason muutokselle ja antoivat yhdenmukaisia havaintoarvoja.
Resumo:
Kotkan jakelualueella käytetään historiallisista syistä keskijänniteverkossa kahta jänniteta-soa, 10 kV ja 20 kV. Eri jännitetasojen lisäksi Kotkan jakelualueen 110/20 päämuuntajien kytkentäryhmänä on käytössä YNyn0, kun taas muualla verkossa käytetään YNd11 kyt-kentäryhmää. Jännitetasoista ja kytkentäryhmistä johtuen Kotkan jakeluverkon yhteenkyt-kettävyys ympäröivän verkon kanssa on haastavaa. Työn tavoitteena on selvittää Kotkan kaupungin keskijänniteverkon nykytila ja käytettä-vyys häiriötilanteissa pahimpana mahdollisena aikana, sekä löytää mahdolliset ongelma-kohdat. Verkon nykytila tarkasteltiin verkkotietojärjestelmän avulla käyttäen laskennallisia tuloksia, jotka skaalattiin vastaamaan kovemman pakkastalven kuormitusta. Skaalaus teh-tiin useamman vuoden takaiseen tilanteeseen, jolloin yleinen taloustilanne oli parempi ja verkon kuormitus suurempi, jolloin verkko ei tule alimitoitetuksi taloustilanteen parantuessa. Tulevaisuuden varalta muodostettiin alueen tulevaisuuden kuormitusennusteet käyttämällä historiatietoja sekä tulevaisuuden näkymiä apuna. Työn keskeisimmäksi sisällöksi muodostui selvittää tarve usean käyttöjännitteen säilyttä-miselle sekä erilaisten kytkentäryhmien ylläpitämiseen ja kosketusjänniteongelman ratkai-seminen. Alueen sähköverkon kehittämiseksi tehtiin useita eri vaihtoehtoja, joita vertailtiin elinkaarikustannusperiaatteella toisiinsa. Vertailun pohjalta saatiin investointistrategia ehdo-tukset, joiden pohjalta verkkoyhtiö voi tehdä tulevaisuuteen sijoittuvia ratkaisuja.
Resumo:
The objective was to determine the glycemic index and glycemic load of tropical fruits and the potential risk for chronic diseases. Nine fruits were investigated: coconut water (for the purpose of this study, coconut water was classified as a “fruit”), guava, tamarind, passion fruit, custard apple, hog plum, cashew, sapodilla, and soursop. The GI and GL were determined according to the Food and Agriculture Organization protocol. The GL was calculated taking into consideration intake recommendation guidelines; 77.8% of the fruits had low GI although significant oscillations were observed in some graphs, which may indicate potential risks of disease. Coconut water and custard apple had a moderate GI, and all fruits had low GL. The fruits evaluated are healthy and can be consumed following the daily recommended amount. However, caution is recommended with fruits causing early glycemic peak and the fruits with moderated GI (coconut water and custard apple).
Resumo:
Today, renewable energy technologies and modern power electronics have made it feasible to implement low voltage direct current (LVDC) microgrids (MGs) ca-pable to island operation. Such LVDC networks are particularly useful in remote areas. However, there are still pending issues in island operated LVDC MGs like electrical safety and controlled operation, which should be addressed before wide-scale implementation. This thesis is focused on the overall protection of an island operated LVDC network concept, including protection against electrical shocks, mains equipment protection and protection of photovoltaic (PV) power sources and battery energy storage systems (BESSs). The topic is approached through ex-amination of the safety hazards and the appropriate methods to protect against them, comprising considerations for earthing system selection and realisation of the protection system.
Resumo:
The electricity distribution sector will face significant changes in the future. Increasing reliability demands will call for major network investments. At the same time, electricity end-use is undergoing profound changes. The changes include future energy technologies and other advances in the field. New technologies such as microgeneration and electric vehicles will have different kinds of impacts on electricity distribution network loads. In addition, smart metering provides more accurate electricity consumption data and opportunities to develop sophisticated load modelling and forecasting approaches. Thus, there are both demands and opportunities to develop a new type of long-term forecasting methodology for electricity distribution. The work concentrates on the technical and economic perspectives of electricity distribution. The doctoral dissertation proposes a methodology to forecast electricity consumption in the distribution networks. The forecasting process consists of a spatial analysis, clustering, end-use modelling, scenarios and simulation methods, and the load forecasts are based on the application of automatic meter reading (AMR) data. The developed long-term forecasting process produces power-based load forecasts. By applying these results, it is possible to forecast the impacts of changes on electrical energy in the network, and further, on the distribution system operator’s revenue. These results are applicable to distribution network and business planning. This doctoral dissertation includes a case study, which tests the forecasting process in practice. For the case study, the most prominent future energy technologies are chosen, and their impacts on the electrical energy and power on the network are analysed. The most relevant topics related to changes in the operating environment, namely energy efficiency, microgeneration, electric vehicles, energy storages and demand response, are discussed in more detail. The study shows that changes in electricity end-use may have radical impacts both on electrical energy and power in the distribution networks and on the distribution revenue. These changes will probably pose challenges for distribution system operators. The study suggests solutions for the distribution system operators on how they can prepare for the changing conditions. It is concluded that a new type of load forecasting methodology is needed, because the previous methods are no longer able to produce adequate forecasts.
Resumo:
The development of new procedures for quickly obtaining accurate information on the physiological potential of seed lots is essential for developing quality control programs for the seed industry. In this study, the effectiveness of an automated system of seedling image analysis (Seed Vigor Imaging System - SVIS) in determining the physiological potential of sun hemp seeds and its relationship with electrical conductivity tests, were evaluated. SVIS evaluations were performed three and four days after sowing and data on the vigor index and the length and uniformity of seedling growth were collected. The electrical conductivity test was made on 50 seed replicates placed in containers with 75 mL of deionised water at 25 ºC and readings were taken after 1, 2, 4, 8 and 16 hours of imbibition. Electrical conductivity measurements at 4 or 8 hours and the use of the SVIS on 3-day old seedlings can effectively detect differences in vigor between different sun hemp seed lots.
Resumo:
D-luokan vahvistimien etu perinteisiin A- tai AB-luokan vahvistimiin nähden on niitten korkea hyötysuhde ja pieni koko. Lisäksi ne ovat edullisia ja niihin voidaan asentaa pienemmät jäähdytyslevyt kuin perinteisiin vahvistimiin korkean hyötysuhteen ansiosta. Tässä tutkimuksessa asennetaan Peavey Solo –kitaravahvistimen pääteasteena toimivan AB-luokan päätevahvistimen tilalle tehokkaampi ja uudempaa vahvistinluokkaa edustava D-luokan vahvistin. Tutkimuksessa selvitetään, miten D-luokan vahvistimella toteutettu kytkentä toimii verrattuna alkuperäiseen kytkentään tutkimalla kitaravahvistimelle tyypillisiä sähköisiä ominaisuuksia. Työ toteutetaan mittauksin. Koska työssä olevissa kytkennöissä on jännitteisiä osia, on siinä perehdyttävä sähköturvallisuuteen. D-luokan vahvistin asettaa tietyt sähkötekniset kestävyysvaatimukset kytkennän teholähteelle ja kaiutinelementille, jolloin työssä paneudutaan myös niiden valintaan. D-luokan vahvistimeen päivitetyn kytkennän tuottamat äänenpainetasot olivat valtaosassa mittauksia suuremmat kuin alkuperäisellä kytkennällä. Äänenpainetasojen mittaustilanteissa myös kuormalle syötetyt tehot olivat suuremmat päivitetyllä kytkennällä verrattuna alkuperäiseen. Suurin päivitetyn kytkennän kuorman teho 72,72 W saavutettiin, kun kaiutinelementin yli oli 24,12 V:n jännitteen tehollisarvo ja kuorman teho oli noin 36 kertaa suurempi kuin alkuperäisellä kytkennällä. D-luokan vahvistimen mitatut harmonisen särön arvot ovat huomattavasti pienempiä kuin alkuperäisellä vahvistimella. Muokkaamattoman vahvistimen mitatusta sähköisestä taajuusvasteeesta nähdään, että alkuperäinen vahvistin korostaa tiettyjä taajuuksia, kun D-luokan vahvistimen taajuusvaste on sen sijaan likimain tasainen. Akustinen taajuusvaste ei ole niin tasainen D-luokan vahvistimeen päivitetyllä kytkennällä kuin alkuperäisellä kytkennällä ja sillä on myös kapeampi taajuusalue. Jos päivitetyn kytkennän sointia haluttaisiin parantaa, pitäisi tutkia lisää akustiseen taajuusvasteeseen vaikuttavia asioita.
Resumo:
Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.
Resumo:
The impact of ventricular rate (VR) on the outcome of electrical cardioversion (ECV) of acute atrial fibrillation (AF) is currently unknown. We aimed to determine the effect of VR during acute AF on the success of ECV, recurrence of AF and occurrence of post-cardioversion complications in 30 days follow-up. All ECVs performed in patients with acute atrial fibrillation lasting <48 hours in 2 Finnish university hospitals during 2003-2010 and 1 central hospital during 2010 were retrospectively identified. A total of 6,624 ECVs were performed in 2,821 consecutive patients. VR≤60 BPM was defined low and VR≥160 BPM high. The median VR before ECV was 109 BPM. The success rate of ECV was 94.2%. Bradycardia occurred in 62 (0.9%) and thromboembolic complications in 39 (0.6%) ECVs. Low VR was observed before 75 (1.1%) ECVs and male sex was its only independent predictor. High VR was observed in 165 (2.5%) ECVs. The independent predictors of high VR were younger age, <12 h episode duration, no previous history of AF and alcohol abuse. Low or high VR were not related to the success of ECV, incidence of thromboembolic or bradycardic complications, or recurrence of AF, although VR was significantly (p<0.001) lower in the patients in whom AF recurred. In conclusion, ECV of acute AF is an effective procedure and VR during AF does not affect its efficacy, the maintenance of sinus rhythm or the incidence of bradycardic, thromboembolic or other complications during 30 days follow-up after ECV. Low VR is predominately observed in male patients, while high VR was a feature related to a shorter history of AF and high alcohol-intake.