862 resultados para ELECTROCHEMICAL-DFT CORRELATION
Resumo:
Electrodes consisting of Pt nanoparticles dispersed on thin films of niobium oxide were prepared onto titanium substrates by a sol-gel method. The physical characterization of these electrodes was carried out by X-ray diffraction, scanning electron microscopy and energy dispersive X-ray analysis. The mean size of the Pt particles was found to be 10.7 nm. The general aspects of the electrochemical behavior were studied by cyclic voltammetry in 1 mol L-1 HClO4 aqueous solution. The response of these electrodes in relation to the oxidation of formaldehyde and methanol in acidic media was also studied.
Resumo:
TLC autographic assays revealed in the hexane extract of Iryanthera juruensis (Myristicaceae) the presence of two compounds, with antioxidant properties towards beta-carotene. They were isolated and identified as 3-methyl-sargachromenol (1) and sargachromenol (2). Further investigation of the hexane extract led to isolations of 3-methyl-sargaquinoic acid (3) and sargaquinoic acid (4). The electrochemical behaviour of these compounds was studied in CH2Cl2/Bu4NBF4 at glassy carbon electrode. The phenolic group in both tocotrienols 1 and 2 are oxidized at +0.23V and +0.32V and their oxidation potentials are correlated with the observed antioxidant activities and oxidation mechanism of alpha-tocopherol. The reductive voltametric behaviour of quinone function in both plastoquinones 3 and 4 is discussed.
Resumo:
The electrochemical reduction of p-nitrobenzenesulfonyl chloride (NBSCl) in dimethylsulfoxide (DMSO) solution is used here as a model to investigate the role of sulfinic acid derivative in this compound's global reduction process. Cyclic voltammetric experiments reveal the production of sulfinic acid derivative, which is important in chemical reactions involving the original compound and other intermediates. This paper also discusses the probable mechanisms of the reduction.
Resumo:
Electrode kinetics and study of 'transition state' with applied potential in case of [M - antibiotics - cephalothin] system were reported at pH = 7.30 ± 0.01 at suitable supporting electrolyte at 25.0ºC. The M = Co or Ni and antibiotics were doxycycline, chlortetracycline, oxytetracycline, tetracycline, minocycline, amoxicillin and chloramphenicol used as primary ligands and cephalothin as secondary ligand. Kinetic parameters viz. transfer coefficient (a), degree of irreversibility (l), diffusion coefficient (D) and rate constant (k) were determined. The values of a and k varied from 0.41 to 0.59 and 2.60 X 10-3 cm s-1 to 9.67 X 10-3 cm s-1 in case of [Co - antibiotics - cephalothin] system. In case of [Ni - antibiotics - cephalothin], a and k varied from 0.41 to 0.58 and 2.34 X 10-3 cm s-1 to 9.19 X 10-3 cm s-1 respectively confirmed that transition state behaves between oxidant and reductant response to applied potential and it adjusts it self in such a way that the same is located midway between dropping mercury electrode and solution interface. The values of rate constant confirmed the quasireversible nature of electrode processes. The stability constants (logb) of complexes were also determined.
Resumo:
Bis-(µ2-oxo)-tetrakis{[1-feniltriazene-1,3-diil)-2-(phenyltriazenil)benzene copper(II) is a tetranuclear complex which shows four Cu(II) ions coordinated by four 1,2-bis(phenyltriazene)benzene bridged ligands, with one diazoaminic deprotonated chain, and two O2- ligands. The complex reduces at E1/2 = -0.95 V vs Fc+/Fc, a two electrons process. Cyclic voltammetric and spectroelectrochemical studies showed a reversible process. When immobilized on carbon paste electrode, the complex electrocatalyses the reduction of O2 dissolved on aqueous solution at -0.3 V vs SCE potential. The obtained current shows linearity with O2 concentration.
Resumo:
Vi omges i vardagen av alla sorters plaster, som kemiskt kallas för polymerer. Vi anknyter dem oftast till vardagliga föremål såsom muggar, leksaker eller platskassar. Det finns dock en särklass av polymerer som fås elektriskt ledande genom en så kallad dopningsprocess. Dopning innebär i detta fall oxidation eller reduktion av konjugerade dubbelbindningar i polymerstrukturen. Detta har lett till utveckling av elektriska apparater där dyra, och i vissa fall även sällsynta, metall och halvledarmaterial ersätts genom av elektriskt ledande polymerer (plaster). Utöver elektronisk ledningsförmåga uppvisar dessa polymerer också jonisk ledningsförmåga. Denna kombination av unika egenskaper möjliggör skapandet av t.ex. nya sensormaterial som kan överföra kemisk information till en mätbar elektronisk signal. Detta öppnar i sin tur möjligheter att göra snabba, billiga och känsliga sensorer för bl.a. mediciniska analyser. I denna avhandling karakteriserades elektrokemiskt och spektroelektrokemiskt N- och ring-substituerade polyanilinfilmer. Polyanilin (PANI) hör till de mest studerade elektriskt ledande polymererna. Den är stabil och lätt att framställa. Substituerade polyaniliner har ändå studerats måttligt, mest p.g.a. att substituerade PANIs ledningsförmåga är lägre än PANIs och deras framställning kan vara svår. De nya grupperna i PANI-kedjan ger dock en möjlighet att binda ytterligare molekyler av intresse till PANI-kedjan, som t.ex. jonselektiva grupper. Kovalent bundna selektiva molekyler ger upphov till stabila, känsliga och selektiva sensormaterial. Karakteriseringen av de studerade polymerer är viktig för den fundamentala förståelsen av deras unika egenskaper och för utvecklingen av framtidens sensormaterial. -------------------------------------- Käytämme joka päivä monenlaisia muoveja, joita kutsutaan kemiassa myös polymeereiksi. Olemme tottuneet yhdistämään muovit arkisiin esineisiin kuten mukeihin, leluihin tai muovikasseihin. On kuitenkin olemassa erityisiä polymeerejä, jotka voidaan saada sähköä johtaviksi hapetus- ja pelkistysreaktioiden avulla. Tästä johtuen on kehitteillä sähköisiä laitteita, joissa kalliit ja jossain tapauksissa myös harvinaisia metalleja sisältävät osat ja puolijohteet voidaan korvata johdepolymeereillä (eli muoveilla). Sähkönjohtavuuden lisäksi johdepolymeereillä on myös ionijohtavuutta. Näiden erityislaatuisten ominaisuuksien yhdistelmä on mahdollistanut mm. sensorimateriaalin kehittämisen, sillä kemiallinen tieto voidaan kääntää mitattavaksi sähköiseksi signaaliksi. Tämä taas omalta osaltaan mahdollistaisi nopeiden, halpojen ja herkkien sensorien valmistuksen, mm. diagnostiikkaan. Tässä väitöksessä on tutkittu sähkökemiallisesti valmistettuja N- ja rengassubstituoituja polyaniliinikalvoja. Polyaniliini (PANI) on yksi eniten tutkituista johdepolymeereistä. Se on stabiili ja helppo valmistaa. Substituoidut polyaniliinit ovat herättäneet vain kohtalaista tieteellistä kiinnostusta, lähinnä, koska niiden sähköinen johdekyky on alhaisempi kuin PANIn. Myös niiden valmistus voi olla vaikeaa. Substituoidut molekyylit PANI-ketjussa mahdollistavat kuitenkin, että niihin voi liittää uusia molekyylejä, esim. ioniherkkiä ryhmiä. Kovalentisti sitoutuneilla selektiivisillä molekyyleillä saadaan tehtyä stabiileja, herkkiä ja selektiivisiä sensorimateriaaleja. Väitöksessä käytettyjen polymeerien karakterisointi on tärkeää, jotta niiden erityisominaisuuksia pystyttäisiin ymmärtämään paremmin ja myös kehittämään sopivia tulevaisuuden sensorimateriaaleja.
Resumo:
Computational material science with the Density Functional Theory (DFT) has recently gained a method for describing, for the first time the non local bonding i.e., van der Waals (vdW) bonding. The newly proposed van der Waals-Density Functional (vdW-DF) is employed here to address the role of non local interactions in the case of H2 adsorption on Ru(0001) surface. The later vdW-DF2 implementation with the DFT code VASP (Vienna Ab-initio Simulation Package) is used in this study. The motivation for studying H2 adsorption on ruthenium surface arose from the interest to hydrogenation processes. Potential energy surface (PES) plots are created for adsorption sites top, bridge, fcc and hcp, employing the vdW-DF2 functional. The vdW-DF yields 0.1 eV - 0.2 eV higher barriers for the dissociation of the H2 molecule; the vdW-DF seems to bind the H2 molecule more tightly together. Furthermore, at the top site, which is found to be the most reactive, the vdW functional suggests no entrance barrier or in any case smaller than 0.05 eV, whereas the corresponding calculation without the vdW-DF does. Ruthenium and H2 are found to have the opposite behaviors with the vdW-DF; Ru lattice constants are overestimated while H2 bond length is shorter. Also evaluation of the CPU time demand of the vdW-DF2 is done from the PES data. From top to fcc sites the vdW-DF computational time demand is larger by 4.77 % to 20.09 %, while at the hcp site it is slightly smaller. Also the behavior of a few exchange correlation functionals is investigated along addressing the role of vdW-DF. Behavior of the different functionals is not consistent between the Ru lattice constants and H2 bond lengths. It is thus difficult to determine the quality of a particular exchange correlation functional by comparing equilibrium separations of the different elements. By comparing PESs it would be computationally highly consuming.
Resumo:
Objective: To evaluate the possible association between the scale of Alvarado (EA) and macroscopic appearance (MA) of the appendix in patients with acute appendicitis.Methods: after receiving the diagnosis of acute appendicitis, EA data were collected. During appendectomy, MA data were collected. Data from patients without appendicitis were excluded. The Spearman correlation test was used to compare EA with Appendix MA (p < 0.05). Other variables were represented by simple frequency. The confidence interval (CI) of 95% was calculated for the correlation test.Results: Data were collected from 67 consecutive patients. The mean age was 37.1 ± 12.5 years and 77.6% of patients were male. The Spearman correlation test used for EA and MA was + 0.77 (95% CI 0.65-0.85, p < 0.0001).Conclusion: although correlation was not perfect, our data indicate that a high score on the scale of Alvarado in patients with appendicitis is correlated with advanced stages of the inflammatory process of acute appendicitis.
Resumo:
Objective: To correlate anatomical and functional changes of the oral cavity, pharynx and larynx to the severity of obstructive sleep apnea syndrome (OSAS). Methods : We conducted a cross-sectional study of 66 patients of both genders, aged between 21 and 59 years old with complaints of snoring and / or apnea. All underwent full clinical evaluation, including physical examination, nasolarybgoscopy and polisonography. We classified individuals into groups by the value of the apnea-hypopnea index (AHI), calculated measures of association and analyzed differences by the Kruskal-Wallis and chi-square tests. Results : all patients with obesity type 2 had OSAS. We found a relationship between the uvula projection during nasoendoscopy and OSAS (OR: 4.9; p-value: 0.008; CI: 1.25-22.9). In addition, there was a major strength of association between the circular shape of the pharynx and the presence of moderate or severe OSAS (OR: 9.4, p-value: 0.002), although the CI was wide (1.80-53.13). The septal deviation and lower turbinate hypertrophy were the most frequent nasal alterations, however unrelated to gravity. Nasal obstruction was four times more common in patients without daytime sleepiness. The other craniofacial anatomical changes were not predictors for the occurrence of OSAS. Conclusion : oral, pharyngeal and laryngeal disorders participate in the pathophysiology of OSAS. The completion of the endoscopic examination is of great value to the evaluation of these patients.
Resumo:
Ion exchange membranes are indispensable for the separation of ionic species. They can discriminate between anions and cations depending on the type of fixed ionic group present in the membrane. These conventional ion exchange membranes (CIX) have exceptional ionic conductivity, which is advantageous in various electromembrane separation processes such as electrodialysis, electrodeionisation and electrochemical ion exchange. The main disadvantage of CIX membranes is their high electrical resistance owing to the fact that the membranes are electronically non conductive. An alternative can be electroactive ion exchange membranes, which are ionically and electronically conducting. Polypyrrole (PPy) is a type of electroactive ion exchange material as well as a commonly known conducting polymer. When PPy membranes are repeatedly reduced and oxidised, ions are pumped through the membrane. The main aim of this thesis was to develop electroactive cation transport membranes based on PPy for the selective transport of divalent cations. Membranes developed composed of PPy films deposited on commercially available support materials. To carry out this study, cation exchange membranes based on PPy doped with immobile anions were prepared. Two types of dopant anions known to interact with divalent metal ions were considered, namely 4-sulphonic calix[6]arene (C6S) and carboxylated multiwalled carbon nanotubes (CNT). The transport of ions across membranes containing PPy doped with polystyrene sulphonate (PSS) and PPy doped with para-toluene sulphonate (pTS) was also studied in order to understand the nature of ion transport and permeability across PPy(CNT) and PPy(C6S) membranes. In the course of these studies, membrane characterisation was performed using electrochemical quartz crystal microbalance (EQCM) and scanning electron microscopy (SEM). Permeability of the membranes towards divalent cations was explored using a two compartment transport cell. EQCM results demonstrated that the ion exchange behaviour of polypyrrole is dependent on a number of factors including the type of dopant anion present, the type of ions present in the surrounding medium, the scan rate used during the experiment and the previous history of the polymer film. The morphology of PPy films was found to change when the dopant anion was varied and even when the thickness of the film was altered in some cases. In nearly all cases the permeability of the membranes towards metal ions followed the order K+ > Ca2+ > Mn2+. The one exception was PPy(C6S), for which the permeability followed the order Ca2+ ≥ K+ > Mn2+ > Co2+ > Cr3+. The above permeability sequences show a strong dependence on the size of the metal ions with metal ions having the smallest hydrated radii exhibiting the highest flux. Another factor that affected the permeability towards metal ions was the thickness of the PPy films. Films with the least thickness showed higher metal ion fluxes. Electrochemical control over ion transport across PPy(CNT) membrane was obtained when films composed of the latter were deposited on track-etched Nucleopore® membranes as support material. In contrast, the flux of ions across the same film was concentration gradient dependent when the polymer was deposited on polyvinylidene difluoride membranes as support material. However, electrochemical control over metal ion transport was achieved with a bilayer type of PPy film consisting of PPy(pTS)/PPy(CNT), irrespective of the type of support material. In the course of studying macroscopic charge balance during transport experiments performed using a two compartment transport cell, it was observed that PPy films were non-permselective. A clear correlation between the change in pH in the receiving solution and the ions transported across the membrane was observed. A decrease in solution pH was detected when the polymer membrane acted primarily as an anion exchanger, while an increase in pH occurred when it functioned as a cation exchanger. When there was an approximately equal flux of anions and cations across the polymer membrane, the pH in the receiving solution was in the range 6 - 8. These observations suggest that macroscopic charge balance during the transport of cations and anions across polypyrrole membranes was maintained by introduction of anions (OH-) and cations (H+) produced via electrolysis of water.
Resumo:
PURPOSE: To investigate relationship between placental thickness during the second and third trimesters and placental and birth weights. METHODS: From January 2011 to June 2012, a total of 250 singleton pregnant women presented at our antenatal clinic were enrolled in this prospective study. All recruited women were assessed at the 1st trimester screening for baseline demographic and obstetric data. The placental thickness was measured trans-abdominally by placing the ultrasound transducer perpendicularly to the plane of the placenta, in the area of the cord insertion at second and third trimester. Pearson's correlation analysis was used to establish the degree of relationship between placental thickness and birth and placental weights. RESULTS: Of 250 recruited participants, 205 women were able to complete the study. The mean age of cases was 26.4±5.1. Values of mean birth and placental weights were 305.56±657.0 and 551.7±104.8 grams respectively. Ultrasonographic measures of placental thickness in second and third trimester and changes between them were 21.68±4.52, 36.26±6.46 and 14.67±5.67 mm respectively. There was a significant positive correlation between placental thickness and birth weight in the second and third trimesters (r=0.15, p=0.03; r=0.14, p=0.04 correspondingly). CONCLUSION: According to our study, birth weight has a positive relation with both second and third trimester placental thickness; however, placental thickness change could not predict low birth weight.
Resumo:
E-cadherin is a cell-cell adhesion molecule and low e-cadherin expression is related to invasiveness and may indicate a bad prognosis in mammary neoplasms. The expression of cell proliferation markers PCNA and especially Ki-67, has also proved to have a strong prognostic value in this tumor class. The expression of these markers was related to the clinical-pathological characteristics of 73 surgically removed mammary tumors in female dogs by immunohistochemistry. There was no statistical correlation between these markers and death by neoplasm, survival time and disease-free interval. However, the loss of e-cadherin expression and marked Ki-67 expression (p=0.016) were considered statistically significant for the diagnosis (p=0.032). When evaluated as independent factors, there was evidence of the relationship between the loss of e-cadherin expression and high PCNA expression with changes in the body status (divided into obese, normal and cachectic) of female dogs (p=0.030); there was also evidence of the relationship between pseudopregnancy and e-cadherin alone (p=0.021) and for ulceration and PCNA alone (p=0.035). The significant correlation between the markers expression and these well known prognostic factors used individually or in combination suggests their prognostic value in canine mammary tumors.
Resumo:
Ipomoea carnea subsp. fistulosa, aguapei or mandiyura, is responsible for lysosomal storage in goats. The shrub contains several alkaloids, mainly swansonine which inhibits lysosomal α-mannosidase and Golgi mannosidase II. Poisoning occurs by inhibition of these hydrolases. There is neuronal vacuolation, endocrine dysfunction, cardiovascular and gastrointestinal injury, and immune disorders. Clinical signs and pathology of the experimental poisoning of goats by Ipomoea carnea in Argentina are here described. Five goats received fresh leaves and stems of Ipomoea. At the beginning, the goats did not consume the plant, but later, it was preferred over any other forage. High dose induced rapid intoxication, whereas with low doses, the course of the toxicosis was more protracted. The goats were euthanized when they were recumbent. Cerebrum, cerebellum, medulla oblongata, pons and colliculi, were routinely processed for histology. In nine days, the following clinical signs developed: abnormal fascies, dilated nostrils and abnormal postures of the head, cephalic tremors and nystagmus, difficulty in standing. Subsequently, the goats had a tendency to fall, always to the left, with spastic convulsions. There was lack in coordination of voluntary movements due to Purkinje and deep nuclei neurons damage. The cochlear reflex originated hyperreflexia, abnormal posture, head movements and tremors. The withdrawal reflex produced flexor muscles hypersensitivity at the four legs, later depression and stupor. Abnormal responses to sounds were related to collicular lesions. Thalamic damage altered the withdrawal reflex, showing incomplete reaction. The observed cervical hair bristling was attributed to a thalamic regulated nociceptive response. Depression may be associated with agonists of lysergic acid contained in Ipomoea. These clinical signs were correlated with lesions in different parts of the CNS.
Resumo:
Electrocoagulation is a process in which wastewater is treated under electrical current. Coagulant is formed during the process through the metal anode dissolution to respective ions which react with hydroxyl ions released in cathode. These metal hydroxides form complexes with pollutant ions. Pollutants are removed among metal hydroxide precipitates. This study was concentrated on describing chemistry and device structures in which electrochemical treatment operations are based on. Studied pollutants were nitrogen compounds, sulphate, trivalent and pentavalent arsenic, heavy metals, phosphate, fluoride, chloride, and bromide. In experimental part, removal of ammonium, nitrate, and sulphate during electrochemical treatment was studied separately. Main objective of this study was to find suitable metal plate material for ammonium, nitrate, and sulphate removal, respectively. Also other parameters such as pH of solution, concentration of pollutant and sodium chloride, and current density were optimized. According to this study the most suitable material for ammonium and sulphate removal by electrochemical treatment was stainless steel. Respectively, iron was the optimum material for nitrate removal. Rise in the pH of solution at the final stage of electrochemical treatment of ammonium, nitrate, and sulphate was detected. Conductivities of solutions decreased during ammonium removal in electrochemical processes. When nitrate and sulphate were removed electrochemically conductivities of solutions increased. Concentrations of residual metals in electrochemically treated solutions were not significant. Based on this study electrochemical treatment processes are recommended to be used in treatment of industrial wastewaters. Treatment conditions should be optimized for each wastewater matrix.
Resumo:
Hemolytic profile of an artificial device chronically implanted in the cardiovascular system may represent the difference between the success and failure in its long-term performance. Last decades have witnessed efforts on the development of methods capable of predicting red blood cell damage in artificial organs. However, all of them have had limited success to predict hemolysis. The primary cause of this problem is that such models do not take into consideration structures of turbulent flow. The present paper demonstrates that microscopic measurable occurrences of the turbulent flow may be linked to red blood cell trauma. This study suggests that if the smallest turbulent eddies dimension is under 10 m m hemolysis is not dependent on the exposure time and the red blood cells damage depends only on the dissipation of the turbulent energy in the erythrocyte membrane. The analysis reported here opens the possibility of mapping the flow field in artificial assist devices based on the smallest eddy length scales. This is a promising new trend and should be considered in the designing requirements of the next generations of artificial organs.