874 resultados para Dual-energy x-ray absorptiometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymer based scintillator composites have been fabricated by combining poly(vinylidene fluoride) (PVDF) and Gd2O3:Eu nanoparticles (50nm). PVDF has been used since it is a flexible and stable binder matrix and highly resistance to thermal and light deterioration. Gd2O3:Eu has been selected as scintillator material due to its wide band gap, high density and suitable visible light yield. The structural, mechanical, thermal and electrical characteristics of the composites were studied as a function of filler content, together with their performance as scintillator material. The introduction of Gd2O3:Eu nanoparticles into the PVDF matrix does not influence the morphology of the polymer or the degree of crystallinity. On the other hand, an increase of the Young´s modulus with respect to PVDF matrix is observed for filler contents of 0.1-0.75 wt.%. The introduction of Gd2O3:Eu into the PVDF matrix increases dielectric constant and DC electrical conductivity as well as the visible light yield in the nanocomposite, being this increase dependent upon Gd2O3:Eu content and X-ray input power. In this way, Gd2O3:Eu/PVDF composites shows suitable characteristics to be used as X-ray radiation transducers, in particular for large area applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La idea principal del proyecto abarca el estudio de parámetros y fenómenos físicos. Los avances logrados se aplicarán al desarrollo de software y metodologías para cuantificación de materiales mediante microanálisis con sonda de electrones y microscopía electrónica de barrido. El microanálisis no es una técnica absoluta, sino que requiere de estándares de referencia, para obviar el uso de ciertos parámetros geométricos y atómicos difíciles de conocer con una precisión adecuada. Para contar con un método sin estándares debe abordarse la determinación de parámetros atómicos e instrumentales, que es uno de los aspectos que se desea encarar en este proyecto. Por otro lado, también se pretende incluir los parámetros estudiados en un software de cuantificación desarrollado por integrantes del proyecto. Otro de los propósitos del plan de trabajo es estudiar la potencialidad de la resolución espacial de una microsonda de electrones con el fin de desarrollar una metodología para caracterizar interfases, bordes de granos e inclusiones, con resolución submicrométrica, ya que los métodos tradicionales de cuantificación se restringen al caso de muestras planas y homogéneas dentro del volumen de interacción, pero la caracterización de inhomogeneidades a nivel micrométrico no ha sido desarrollada todavía, salvo algunas excepciones. The main idea of this project involves the study of physical parameters and phenomena. The concretion of the different goals will permit the elaboration of softeare and methodologies for materials characterization by means of electron probe microanalysis and scanning microscopy. Electron probe microanalysis is not an absolute technique, but requires reference standards in order not to involve certain geometrical and atomic parameters for which high uncertainties cannot be avoided. In order to have standardless method, the determination of atomic and instrumental parameters must be accomplished, as will be faced through this project. Complementary, the parameters studied will be included in a quantification software developed in our research group of FaMAF. Another objective of this activity plan is to study the spatial resolution potentiality of a focalized electron beam, with the aim of characterizing interphases, grain boundaries and inclusions with submicron sensitivity, since the traditional quantification procedures are restricted to flat homogeneous samples, whereas the characterization of inhomogeneities has not been developed yet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is an important carcass quality parameter. The aim of this work is to obtain a calibration equation for the Computed Tomography (CT) scans with the Partial Least Square Regression (PLS) technique in order to predict the LMP of the carcass and the different cuts and to study and compare two different methodologies of the selection of the variables (Variable Importance for Projection — VIP- and Stepwise) to be included in the prediction equation. The error of prediction with cross-validation (RMSEPCV) of the LMP obtained with PLS and selection based on VIP value was 0.82% and for stepwise selection it was 0.83%. The prediction of the LMP scanning only the ham had a RMSEPCV of 0.97% and if the ham and the loin were scanned the RMSEPCV was 0.90%. Results indicate that for CT data both VIP and stepwise selection are good methods. Moreover the scanning of only the ham allowed us to obtain a good prediction of the LMP of the whole carcass.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rosickyite, the natural monoclinic gamma -form of sulphur, exists in only a few localities around the globe. In the old asphalt mine at La Presta, Neuchatel. Switzerland, rosickyite occurs locally as small, but very well formed crystals suitable for crystallographic studies. It grows as an alteration product of pyrite-rich asphalt. Rosickyite from La Presta mine is pure molecular sulphur, as revealed by gas chromatography-mass spectrometry. The X-ray powder diffraction data of La Presta rosickyite does not match the one previously published for this species. Therefore, a single crystal study was undertaken and a new indexed X-ray powder diffraction diagram for natural rosickyite is proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: To test the hypothesis that intervals with superior beat-to-beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance. METHODS: Coronary repositioning precision in consecutive heartbeats was measured on x-ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T2 -prep now follows (T2 -post) rather than precedes the imaging part of the sequence. The performance of T2 -post was quantitatively compared (signal-to-noise [SNR], contrast-to-noise [CNR], vessel sharpness) to that of T2 -prep in vivo. RESULTS: Coronary repositioning precision is <1 mm at peak systole and in mid diastole. When comparing systolic T2 -post to diastolic T2 -prep, CNR and vessel sharpness remained unchanged (both P = NS) but SNR for muscle and blood increased by 104% and 36% (both P < 0.05), respectively. CONCLUSION: Windows with improved coronary repositioning precision exist in the cardiac cycle: one in peak systole and one in mid diastole. Peak-systolic imaging necessitates a re-design of conventional coronary MRA pulse sequences and leads to image quality very similar to that of conventional mid-diastolic data acquisition but improved SNR. J. Magn. Reson. Imaging 2015;41:1251-1258. © 2014 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantitative ultrasound (QUS) appears to be developing into an acceptable, low-cost and readily-accessible alternative to dual X-ray absorptiometry (DXA) measurements of bone mineral density (BMD) in the detection and management of osteoporosis. Perhaps the major difficulty with their widespread use is that many different QUS devices exist that differ substantially from each other, in terms of the parameters they measure and the strength of empirical evidence supporting their use. But another problem is that virtually no data exist outside of Caucasian or Asian populations. In general, heel QUS appears to be most tested and most effective. Some, but not all heel QUS devices are effective assessing fracture risk in some, but not all populations, the evidence being strongest for Caucasian females > 55 years old, though some evidence exists for Asian females > 55 and for Caucasian and Asian males > 70. Certain devices may allow to estimate the likelihood of osteoporosis, but very limited evidence exists supporting QUS use during the initiation or monitoring of osteoporosis treatment. Likely, QUS is most effective when combined with an assessment of clinical risk factors (CRF); with DXA reserved for individuals who are not identified as either high or low risk using QUS and CRF. However, monitoring and maintenance of test and instrument accuracy, precision and reproducibility are essential if QUS devices are to be used in clinical practice; and further scientific research in non-Caucasian, non-Asian populations clearly is compulsory to validate this tool for more widespread use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Summary : Aim: To assess the number of immigrants with pulmonary tuberculosis detected by chest x-ray screening at the Swiss border. Method: All adult immigrants entering Switzerland in 2004 were screened by chest x-ray (CXR). The number of radiological abnormalities suggestive of pulmonary tuberculosis, and the proportion requiring treatment for tuberculosis, were assessed retrospectively. The frequency of symptoms among immigrants with documented TB was compared with a sample of immigrants with a normal CXR. Results: Among 8995 immigrants, 8240 had a normal CXR, 630 had some abnormality not suggestive of active TB and 125 (1.4%) had a CXR suggestive of pulmonary TB. A final diagnosis of tuberculosis requiring treatment was made in SO (1 l with positive smear and culture, 16 with positive culture and 23 with negative culture), 57 had fibrotic lesions and 18 had another disease or a normal x-ray on control. The prevalence of symptoms did not differ between 27 immigrants with documented TB (smear+/culture+: 82%, smear-/ culture+: 75%), and 23 with smear-/culturetuberculosis (91%), but lower in 57 immigrants with fibrotic lesions (60%). Cough was more frequent among the 27 immigrants with documented TB (70%) than among 198 smokers without TB (37%) and among 229 non-smokers without TB (15%) Conclusions: Only 22% (27/125) of immigrants with CXR abnormalities suggestive of pulrnonary tuberculosis were documented by smear and/or culture and 40% (50/125) needed antituberculous treatment. 2/11 smear-positive immigrants would not have been detected by a questionnaire on symptoms. Rapport de synthèse : Le but de l'étude est d'évaluer le rendement du dépistage radiologique de la tuberculose pulmonaire chez les immigrés à l'entrée en Suisse. Méthode: parmi les immigrés adultes entrés en Suisse en 2004, qui ont tous passé un contrôle radiologique, le nombre de porteurs de clichés thoraciques suspects de tuberculose et la proportion de cas chez lesquels un traitement antituberculeux a été prescrit ont été évalués rétrospectivement. La fréquence des symptômes chez les immigrés atteints de tuberculose a été comparée à celle d'un groupe contrôle sans tuberculose. Résultats: parmi 8995 immigrés, 8240 avaient un cliché thoracique normal, 630 étaient porteurs d'une anomalie non suspecte de tuberculose active et 125 (1.4%) montraient des signes radiologiques suspects de tuberculose. Un diagnostic final de tuberculose nécessitant un traitement a été posé dans 50 cas (11 cas à frottis et culture positifs, 16 cas à culture positive, 23 cas à culture négative), 57 présentaient des lésions cicatricielles compatibles avec une ancienne tuberculose et 18 avaient une autre affection pulmonaire ou un cliché normal au contrôle. La prévalence des plaintes n'était pas différente entre les 27 immigrés porteurs d'une tuberculose documentée (frottis+ /culture+: 82%, frottis-/culture+ : 75%) et les 23 immigrés atteints d'une tuberculose non documentée (frottis-/culture-: 91%), mais elle était plus élevée que chez les 57 immigrés porteurs de lésions cicatricielles (59%). La toux était plus fréquente chez les 27 tuberculeux documentés (70%) que chez 198 fumeurs sans tuberculose (37%) et chez 229 non fumeurs sans tuberculose (15%). Conclusions: seuls 22% (27/125) des immigrés dont le cliché thoracique est suspect de tuberculose sont porteurs d'une tuberculose documentée par examen direct ou culture et 40% (50/125) nécessitent un traitement antituberculeux. Deux immigrants sur les 11 cas frottis positifs n'auraient pas été dépistés par un questionnaire.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The age of the patient is of prime importance when assessing the radiological risk to patients due to medical X-ray exposures and the total detriment to the population due to radiodiagnostics. In order to take into account the age-specific radiosensitivity, three age groups are considered: children, adults and the elderly. In this work, the relative number of examinations carried out on paediatric and geriatric patients is established, compared with adult patients, for radiodiagnostics as a whole, for dental and medical radiology, for 8 radiological modalities as well as for 40 types of X-ray examinations. The relative numbers of X-ray examinations are determined based on the corresponding age distributions of patients and that of the general population. Two broad groups of X-ray examinations may be defined. Group A comprises conventional radiography, fluoroscopy and computed tomography; for this group a paediatric patient undergoes half the number of examinations as that of an adult, and a geriatric patient undergoes 2.5 times more. Group B comprises angiography and interventional procedures; for this group a paediatric patient undergoes a one-fourth of the number of examinations carried out on an adult, and a geriatric patient undergoes five times more.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Full-field X-ray microscopy is a valuable tool for 3D observation of biological systems. In the soft X-ray domain organelles can be visualized in individual cells while hard X-ray microscopes excel in imaging of larger complex biological tissue. The field of view of these instruments is typically 10(3) times the spatial resolution. We exploit the assets of the hard X-ray sub-micrometer imaging and extend the standard approach by widening the effective field of view to match the size of the sample. We show that global tomography of biological systems exceeding several times the field of view is feasible also at the nanoscale with moderate radiation dose. We address the performance issues and limitations of the TOMCAT full-field microscope and more generally for Zernike phase contrast imaging. Two biologically relevant systems were investigated. The first being the largest known bacteria (Thiomargarita namibiensis), the second is a small myriapod species (Pauropoda sp.). Both examples illustrate the capacity of the unique, structured condenser based broad-band full-field microscope to access the 3D structural details of biological systems at the nanoscale while avoiding complicated sample preparation, or even keeping the sample environment close to the natural state.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of two approaches for high-throughput, high-resolution X-ray phase contrast tomographic imaging being used at the tomographic microscopy and coherent radiology experiments (TOMCAT) beamline of the SLS is discussed and illustrated. Differential phase contrast (DPC) imaging, using a grating interferometer and a phase-stepping technique, is integrated into the beamline environment at TOMCAT in terms of the fast acquisition and reconstruction of data and the availability to scan samples within an aqueous environment. A second phase contrast method is a modified transfer of intensity approach that can yield the 3D distribution of the decrement of the refractive index of a weakly absorbing object from a single tomographic dataset. The two methods are complementary to one another: the DPC method is characterised by a higher sensitivity and by moderate resolution with larger samples; the modified transfer of intensity approach is particularly suited for small specimens when high resolution (around 1 mu m) is required. Both are being applied to investigations in the biological and materials science fields.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray microtomography has become a new tool in earth sciences to obtain non-destructive 3D-image data from geological objects in which variations in mineralogy, chemical composition and/or porosity create sufficient x-ray density contrasts.We present here first, preliminary results of an application to the external and internal morphology of Permian to Recent Larger Foraminifera. We use a SkyScan-1072 high-resolution desk-top micro-CT system. The system has a conical x-ray source with a spot size of about 5µm that runs at 20-100kV, 0-250µA, resulting in a maximal resolution of 5µm. X-ray transmission images are captured by a scintillator coupled via fibre optics to a 1024x1024 pixel 12-bit CCD. The object is placed between the x-ray source and the scintillator on a stub that rotates 360°around its vertical axis in steps as small as 0.24 degrees. Sample size is limited to 2 cm due to the absorption of geologic material for x-rays. The transmission images are back projected using a Feldkamp algorithm into a vertical stack of up to 1000 1Kx1K images that represent horizontal cuts of the object. This calculation takes 2 to several hours on a Double-Processor 2.4GHz PC. The stack of images (.bmp) can be visualized with any 3D-imaging software, used to produce cuts of Larger Foraminifera. Among other applications, the 3D-imaging software furnished by SkyScan can produce 3D-models by defining a threshold density value to distinguish "solid" from "void. Several models with variable threshold values and colors can be imbricated, rotated and cut together. The best results were obtained with microfossils devoid of chamber-filling cements (Permian, Eocene, Recent). However, even slight differences in cement mineralogy/composition can result in surprisingly good x-ray density contrasts.X-ray microtomography may develop into a powerful tool for larger microfossils with a complex internal structure, because it is non-destructive, requires no preparation of the specimens, and produces a true 3D-image data set. We will use these data sets in the future to produce cuts in any direction to compare them with arbitrary cuts of complex microfossils in thin sections. Many groups of benthic and planktonic foraminifera may become more easily determinable in thin section by this way.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We found that lumbar spine texture analysis using trabecular bone score (TBS) is a risk factor for MOF and a risk factor for death in a retrospective cohort study from a large clinical registry for the province of Manitoba, Canada. INTRODUCTION: FRAX® estimates the 10-year probability of major osteoporotic fracture (MOF) using clinical risk factors and femoral neck bone mineral density (BMD). Trabecular bone score (TBS), derived from texture in the spine dual X-ray absorptiometry (DXA) image, is related to bone microarchitecture and fracture risk independently of BMD. Our objective was to determine whether TBS provides information on MOF probability beyond that provided by the FRAX variables. METHODS: We included 33,352 women aged 40-100 years (mean 63 years) with baseline DXA measurements of lumbar spine TBS and femoral neck BMD. The association between TBS, the FRAX variables, and the risk of MOF or death was examined using an extension of the Poisson regression model. RESULTS: During the mean of 4.7 years, 1,754 women died and 1,872 sustained one or more MOF. For each standard deviation reduction in TBS, there was a 36 % increase in MOF risk (HR 1.36, 95 % CI 1.30-1.42, p < 0.001) and a 32 % increase in death (HR 1.32, 95 % CI 1.26-1.39, p < 0.001). When adjusted for significant clinical risk factors and femoral neck BMD, lumbar spine TBS was still a significant predictor of MOF (HR 1.18, 95 % CI 1.12-1.23) and death (HR 1.20, 95 % CI 1.14-1.26). Models for estimating MOF probability, accounting for competing mortality, showed that low TBS (10th percentile) increased risk by 1.5-1.6-fold compared with high TBS (90th percentile) across a broad range of ages and femoral neck T-scores. CONCLUSIONS: Lumbar spine TBS is able to predict incident MOF independent of FRAX clinical risk factors and femoral neck BMD even after accounting for the increased death hazard.