1000 resultados para Daño térmico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No panorama energético atual, medidas de desenvolvimento sustentável têm uma preponderância cada vez mais significativa e, sendo os edifícios responsáveis por 40% da energia consumida na EU, enquadra-se o desafio de integrar medidas de eficiência energética nos novos edifícios desde a fase de conceção. Sendo que este setor se encontra em contínua expansão, a redução dos consumos passará largamente pela otimização do comportamento térmico dos edifícios e dos sistemas energéticos que os equipam. No presente trabalho estudou-se o papel da inércia térmica na redução das necessidades de energia para climatização de edifícios com o objetivo de identificar estratégias destinadas ao melhoramento do comportamento térmico e desempenho energético de edifícios construídos com recurso à técnica construtiva LSF, caracterizados por uma fraca inércia térmica quando comparados com edifícios em tudo semelhantes mas construídos recorrendo a tecnologias convencionais sem esquecer as questões relacionadas com a respetiva viabilidade económica. Com resultado geral destaca-se desde logo a importância do local onde é mais benéfico adicionar massa térmica (paredes exteriores, cobertura, paredes interiores), assim como a necessidade de utilização de um material com elevada densidade energética e baixo custo. A análise comparativa dos diferentes modelos de edifício simulados com recurso ao software DesignBuilder/EnergyPlus, foi realizada recorrendo a uma metodologia em que cada modelo construtivo é avaliado considerando quatro níveis de isolamento térmico e duas condições de cargas térmicas internas. A análise energética e económica foi realizada tendo como referência um período de 20 anos. O custo das soluções construtivas foi maioritariamente obtido através da ferramenta computacional Gerador de Preços, da Cype, SA©, tendo-se considerado um consumo energético anual constante e igual às necessidades de climatização anuais, assim como taxas de atualização de capital e de inflação do custo da energia constantes. De uma forma geral conclui-se que edifícios do tipo LSF melhorados através da adição criteriosa de massa térmica em determinados elementos construtivos, apresentam necessidades de climatização anuais na maioria dos casos estudados, inferiores àquelas verificadas em edifícios convencionais com inércia térmica média/forte. Conclui-se, também, que o método construtivo LSF se apresenta mais eficaz em termos energéticos e económicos quando comparado com soluções semelhantes construídas com recurso a um método convencional. Na secção seguinte são identificadas as principais conclusões deste trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Macaíba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O crescimento da demanda energética, prevista para a metade do século XXI, com números embasados no crescimento demográfico e de consumo dos países em desenvol- vimento, sugere a busca por fontes energéticas renováveis e de menor impacto ao meio ambiente, conforme os tratados da política internacional. Portanto, o fornecimento de energia suplementar se torna vital nas sociedades modernas e sua extensão até o mar tem se constituído uma recente preocupação do ponto de vista enérgico e ecológico. Várias formas de conversão de energia foram desenvolvidas no decorrer dos anos, com destaque para a energia dos gradientes térmicos. A Plataforma Continental Sul do Bra- sil (PSCB) possui alta variabilidade espacial e temporal nos campos de temperatura, de forma que existe a necessidade de uma análise das regiões de maior potencial energético com respeito ao gradiente vertical de temperatura. Neste estudo, foram utilizados dados do modelo OCCAM com uma grade de resolu- ção horizontal de 0, 25o e resolução vertical de 66 níveis, distribuídos ao longo de um sistema de coordenadas vertical. Foram utilizadas imagens de temperatura superfícial do mar (TSM) obtidas a partir do sensor AVHRR (Advanced Very High Resolution Ra- diometer) de forma a realizar a validação dos dados do modelo OCCAM. A análise da média dos dados do modelo indicou um sítio energético de maior viabilidade devido oC ao padrão médio do gradiente térmico de aproximadamente 0, 17 ao longo da coluna vertical (545 m de profundidade) no oceano. Neste local, foram coletados os dados, e aplicados a um módulo de conversão de energia térmica dos oceanos que vem sendo desenvolvido na Universidade Federal do Rio Grande - FURG. A região de estudo de- monstrou possuir um local com ótimo potencial energético, onde a produção máxima de energia pode alcançar 111, 9MW , associada com um padrão variabilidade tempo- ral dominante de 12 meses. Este sítio energético demonstra maior eficiência durante o período de verão e outono ao longo dos anos e sua média para todo o período é de 94, 3MW . Neste estudo, duas correntes: Corrente do Brasil (CB) e a Contra Corrente Costeira (CCC), com águas de origem tropical e subantártica com aportes continentais, respecti- vamente, tem alta correlação com os valores dos gradientes térmicos e com os significa- tivos eventos de conversão energética. O sítio energético demonstrou alta estabilidade à sazonalidade e à gama de eventos meteorológicos e oceanográficos, de forma que pode ser qualificado como uma fonte suplementar a matriz energética do país para um futuro próximo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O arroz (Oryza sativa, L.), como todos os cereais, pode ser contaminado por fungos responsáveis por danos tecnológicos, nutricionais e toxicológicos, dentre eles a produção de micotoxinas. Diversas toxinas fúngicas produzidas pelo gênero Fusarium tem sido relatadas em arroz, no entanto a fumonisina B1 (FB1) é pouco estudada neste grão. As principais características da FB1 é a alta solubilidade em solventes polares, estabilidade a altas temperaturas além de efeitos neurotóxicos e carcinogênicos. Assim o objetivo deste trabalho foi avaliar o efeito do tratamento térmico e hidrotérmico nos teores de fumonisina B1 e nas características químicas de arroz comercial. Na primeira etapa do trabalho foi adaptado um método para detecção e quantificação de FB1 em arroz cru e após cocção, por HPLC-FL. O método foi avaliado quanto aos indicativos de eficiência destacando-se o LOD (30 µg.kg-1) e a recuperação ( 90% para arroz cru e 86% pra arroz cozido). Na segunda etapa realizou-se o levantamento de ocorrência de FB1 em 05 diferentes amostras comerciais de arroz integral, branco e parboilizado da cidade de Rio Grande, RS, totalizando 9 amostras. Foi detectada a presença de FB1 em 7 das 9 amostras, sendo que os maiores índices foram encontrados em amostras de arroz parboilizado e integral apresentando níveis de contaminação entre 30 e 170 µg.kg-1. A terceira etapa do trabalho consistiu no estudo do efeito de tratamentos térmicos sobre os níveis de FB1 em amostras após aplicação de calor. Foram testados tratamento hidrotérmico com evaporação, tratamento hidrotérmico com autoclavagem e tratamento térmico seco. O maior nível de redução dos teores iniciais de FB1 foi 82,8% quando se empregou tratamento térmico seco a 125 °C/3 min. Ainda foram avaliados os efeitos do t ratamento hidrotérmico com evaporação de água na composição química e na digestibilidade protéica. Esta característica proporcionou aumento de até 100% na digestibilidade in vitro das proteínas e reduziu em média 73% do teor de contaminação com FB1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemical changes in clay minerals has been widely studied in order to improve its properties for use in various applications. However kaolinite has strong hydrogen bonds between their adjacent layers hindering the process changes in its structure. With the objective to facilitate the process of intercalation monobasic potassium phosphate, bibasic potassium phosphate and potassium acetate we was performed on kaolinite heat treatment at 600 °C and activated acidic with phosphoric acid and 5 to 10 mol L-1. The samples they were characterized by energy dispersive spectroscopy (EDS), X-Ray Diffraction (XRD), Infrared Spectroscopy Fourier Transform (FTIR) and Thermogravimetric Analysis (TG) and Differential Thermal Analysis (DTG) and the superficial and textural changes the samples with heat treatment and acid activation they were characterized by scanning electron microscopy (SEM) and Textural Analysis of Adsorption/desorption N2. With the help of the techniques found that, the heat treatment becomes more susceptible to acid activation kaolinite making the samples with two treatments show larger amounts of phosphorus. It was also found that bibasic potassium phosphate binds more strongly the structure of kaolinite by having a structure with two-coordinating oxygens and intercalation with potassium acetate in acid-activated kaolin increases the interlayer distance of the kaolinite and the intercalation occurs with higher response index (RI) for samples with acid activation to 5 mol /L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El Daño renal se refiere a la perdida de las funciones normales del riñón, que puede ser de forma transitoria o permanente. La Diabetes es un factor predisponente a desarrollar problemas renales, el objetivo de la investigación fue determinar daño renal en pacientes Diabéticos que consultan en la Unidad Comunitaria de Salud Familiar El Transito, San Miguel. La metodología empleado el estudio es Prospectiva, Transversal, Descriptivo, de laboratorio. La población estuvo constituida por 200 pacientes diabéticos, de los cuales se muestrearon 132; de estos 35 eran del sexo masculino y 97 del sexo femenino, a los que se les aplico una guía de entrevista en los que se conocieron datos generales, se realizaron las pruebas de laboratorio como Glucosa, Creatinina, Nitrógeno Ureico, Urea y Examen General de Orina. Resultados Obtenidos se detectó daño renal en los diferentes estadios de enfermedad, el 59.1% de los pacientes se encuentran en estadio I, el 24.2% resulto en estadio II, el 15.2% en estadio III y el estadio IV con un 1.5%. Los estadio de daño renal de acuerdo al sexo femenino se encontró en estadio I 57.8%, en estadio II fue un 23.8%, estadio III se registró 16.4% y estadio IV solo el 2%. En el sexo masculino se obtuvo que el 62.9% presentaba estadio I, el 25.7% en estadio II y un 11.4% en estadio III. Según el daño renal y la edad de los pacientes, entre las edades de 30-40 años se encontró en estadio I el 44.4%, entre las edades de 41-50 años en estadio II un 26.7%, en estadio III entre las edades de 51-60 años 19.4%. Se encontró el 90.2% de los pacientes con glucosa sérica aumentada. Los valores de creatinina estaban en un 66.7% valores normales y solo el 33.3% aumentada. Los valores normales de Urea fueron del 83.3% y el 14.4% aumentados. Según los resultados de proteínas en orina se registró el 68.9% negativo y el 31.1% positivo. La presencia de glucosa en orina se encontró un 51.5% Negativo y el 48.4% de la población resulto positivo. Conclusión: estadísticamente se aceptó la hipótesis propuesta que más del 14% de los pacientes diabéticos tenían Daño Renal; ya que los pacientes en estadio II al IV que se consideraron con Daño Renal fueron el 40.9%. Palabras Clave: Daño Renal, Diabetes.