905 resultados para Compound semiconductor device
Resumo:
The research trend for harvesting energy from the ambient vibration sources has moved from using a linear resonant generator to a non-linear generator in order to improve on the performance of a linear generator; for example, the relatively small bandwidth, intolerance to mistune and the suitability of the device for low-frequency applications. This article presents experimental results to illustrate the dynamic behaviour of a dual-mode non-linear energy-harvesting device operating in hardening and bi-stable modes under harmonic excitation. The device is able to change from one mode to another by altering the negative magnetic stiffness by adjusting the separation gap between the magnets and the iron core. Results for the device operating in both modes are presented. They show that there is a larger bandwidth for the device operating in the hardening mode compared to the equivalent linear device. However, the maximum power transfer theory is less applicable for the hardening mode due to occurrence of the maximum power at different frequencies, which depends on the non-linearity and the damping in the system. The results for the bi-stable mode show that the device is insensitive to a range of excitation frequencies depending upon the input level, damping and non-linearity.
Resumo:
This paper investigates the feasibility of using an energy harvesting device tuned such that its natural frequency coincides with higher harmonics of the input to capture energy from walking or running human motion more efficiently. The paper starts by reviewing the concept of a linear resonant generator for a tonal frequency input and then derives an expression for the power harvested for an input with several harmonics. The amount of power harvested is estimated numerically using measured data from human subjects. Assuming that the input is periodic, the signal is reconstructed using a Fourier series before being used in the simulation. It is found that although the power output depends on the input frequency, the choice of tuning the natural frequency of the device to coincide with a particular higher harmonic is restricted by the amount of damping that is needed to maximize the amount of power harvested, as well as to comply with the size limit of the device. It is also found that it is not feasible to tune the device to match the first few harmonics when the size of the device is small, because a large amount of damping is required to limit the motion of the mass.
Resumo:
The development of an experimental switching stiffness device fcr shock isolation is presented. The system uses magnetic forces to exert a restoring force, which results in an effective stiffness that is used to isolate a payload. When the magnetic force is turned on and off, a switchable stiffness is obtained. Characterization of the physical properties of the device is presented. They are estimated in terms of the percentage stiffness change and effective damping ratio when switched between two constant stiffness states. Additionally, the setup is used to implement a control strategy to reduce the shock response and minimize residual vibration. The system was found to be very effective for shock isolation. The response is reduced by around 50 percent compared with passive isolation showing good correlation with theoretical predictions, and the effective damping ratio in the system following the shock was increased from about 4.5 percent to 13 percent. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
This work deals with the nonlinear piezoelectric coupling in vibration-based energy harvesting, done by A. Triplett and D.D. Quinn in J. of Intelligent Material Syst. and Structures (2009). In that paper the first order nonlinear fundamental equation has a three dimensional state variable. Introducing both observable and control variables in such a way the controlled system became a SISO system, we can obtain as a corollary that for a particular choice of the observable variable it is possible to present an explicit functional relation between this variable one, and the variable representing the charge harvested. After-by observing that the structure in the Input-Output decomposition essentially changes depending on the relative degree changes, presenting bifurcation branches in its zero dynamics-we are able in to identify this type of bifurcation indicating its close relation with the Hartman - Grobman theorem telling about decomposition into stable and the unstable manifolds for hyperbolic points.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A boa constrictor was presented with a short oblique compound fracture of the rostral third of the right maxilla. The fracture was reduced and biomaterial was placed around the fracture. A computed tomography scan at 1.5 mo post-surgery showed that the fracture had healed with slight displacement of the bone fragments.
Resumo:
The objective of this experiment was to evaluate effects of treatments with intravaginal progesterone (N) device and/or 48 h temporary weaning (TW) on reproductive performance of postpartum anestrous crossbred Angus x Nelore cows, throughout the breeding season (BS). Anestrous cows (n = 296; 53 5 DPP, body condition score between 2.5 and 3.5, on a 1-5 scale) were assigned randomly to four treatments (2 x 2 factorial design): (1) Control Group (no treatment; n = 73); (2) TW Group (48 h TW beginning on day 0 of BS; n = 70); (3) P4 Group (Intravaginal P4 device between days -7 and 0 of BS; n = 73); and (4) P4+TW Group (Intravaginal P4 device between days -7 and 0 of BS followed by 48h TW; n=70). on day 0 of BS (when P4 devices were removed and TW was initiated), cows had their ovaries evaluated by ultrasonography aiming to evaluate size of the largest follicle. Signs of behavioral estrus were observed twice a day (morning and evening), between days 0 and 25 of BS, and cows observed in estrus were inseminated 12 h later. Between days 26 and 80 of BS, cows were submitted to natural service. Pregnancy diagnosis was conducted by transrectal ultrasonography on days 32 and 53 (pregnancies by AI) and 114 (pregnancies by natural service). Rates of detection of estrus during the first 3 days and within 25 days of BS were greater in cows receiving TW (45.0% compared with 9.6% and 50.0% compared with 29.5%, respectively; P < 0.01). Conception rate in cows inseminated in the first 3 days of BS was greater in cows treated with P4 (54.8% compared with 11.1 %; P < 0.01). Combining P4+TW increased pregnancy rate in the first 3 days (Control: 1.4%, TW: 4.3%, P4: 8.2% and P4+TW: 24.3%; P < 0.01) and in 25 days of BS (Control: 10.9%, TW: 7.1%, P4: 13.7% and P4+TW: 28.6%; P < 0.05). Pregnancy rate at the end of BS did not differ among treatment groups. In conclusion, TW alone increased estrous behavior whereas P4 alone benefited conception. Combining P4 with TW improved pregnancy rate with direct benefits to behavioral estrus and conception. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.
Resumo:
Aim: To evaluate the effect of a space-maintaining device fixed to the lateral wall of the maxillary sinus after the elevation of the sinus mucosa on bone filling of the sinus cavity. Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane accomplished through lateral antrostomy in four monkeys, a titanium device was affixed to the lateral sinus wall protruding into the sinus cavity to maintain the mucosa elevated without the use of grafting material. The healing of the tissue around the implants was evaluated after 3 and 6 months. Ground sections were prepared and analyzed histologically. Results: The void under the elevated sinus membrane, originally filled with the blood clot, was reduced after 3 as well as after 6 months of healing of about 56% and 40.5%, respectively. In seven out of eight cases, the devices had perforated the sinus mucosa. The formation of mineralized bone and bone marrow amounted to about 42% and 69% after 3 and 6 months, respectively. The connective tissue represented about 53% and 23% of the newly formed tissue after 3 and 6 months, respectively. Conclusions: New bone formation was found below the devices. However, shrinkage of the newly formed tissue was observed both after 3 and 6 months of healing. Hence, the space-maintaining function of the devices used in the present study has to be questioned.
Resumo:
Background and Objectives: Bone remodeling is characterized as a cyclic and lengthy process. It is currently accepted that not only this dynamics is triggered by a biological process, but also biochemical, electrical, and mechanical stimuli are key factors for the maintenance of bone tissue. The hypothesis that low-level laser therapy (LLLT) may favor bone repair has been suggested. The purpose of this study was to evaluate the bone repair in defects created in rat lower jaws after stimulation with infrared LLLT directly on the injured tissue.Study Design/Materials and Methods: Bone defects were prepared on the mandibles of 30 Holtzman rats allocated in two groups (n = 15), which were divided in three evaluation period (15, 45, and 60 days), with five animals each. control group-no treatment of the defect; laser group-single laser irradiation with a GaAlAs semiconductor diode laser device (lambda = 780 nm; P = 35 mW t = 40 s; circle minus = 1.0 mm; D = 178 J/cm(2); E = 1.4 J) directly on the defect area. The rats were sacrificed at the preestablished periods and the mandibles were removed and processed for staining with hematoxylin and eosin, Masson's Trichrome and picrosirius techniques.Results: the histological results showed bone formation in both groups. However, the laser group exhibited an advanced tissue response compared to the control group, abbreviating the initial inflammatory reaction and promoting rapid new bone matrix formation at 15 and 45 days (P < 0. 05). on the other hand, there were no significant differences between the groups at 60 days.Conclusion: the use of infrared LLLT directly to the injured tissue showed a biostimulating effect on bone remodeling by stimulating the modulation of the initial inflammatory response and anticipating the resolution to normal conditions at the earlier periods. However, there were no differences between the groups at 60 days.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
An investigation was made on the adsorption and kinetics of photodegradation of potassium hydrogenphthalate in an aqueous suspension of TiO2. Two models, Langmuir and Freundlich, were used to describe the adsorption process and the model proposed by Langmuir-Hinshelwood (L-H) was employed to describe the kinetics of the photodecomposition reactions of hydrogenphthalate. The results of the adsorptions were fitted to the models proposed by Langmuir and Freundlich. Adsorption was found to be a function of the temperature, with adsorption capacity increasing from 2.4 to 4.5 mg/g when the temperature rose from 20 to 30 degrees C. The kinetic model indicates that the rate constant, k, of the first order reaction, is high in the 10.0 to 100 mg/l interval, which is coherent with the low value of the adsorption constant, K. The results fitted to the L-H model led to an equation that, within the range of concentrations studied here, theoretically allows one to evaluate the photodegradation rate. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)