770 resultados para CONSUMO DE ENERGIA ELECTRICA - CALLE 26 DE BOGOTA D.C.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

On the field of the projects of hydraulic systems exists a lot of worries when we talk about the calculate of hydraulic pumps. In this case some facts must be considerate: length of tubes, fluid characteristics, height gauge, temperature, pressure, characteristics of tubes, flow required and others. For that mathematic calculates must be developed with the objective to optimize hydraulic pumps and agree to find an ideal machine (that don't requires more energy than necessary or less energy than it requires; that is the more critical case, cause exists the risk that the fluid pumped do not agree to become in your destiny). The wrong calculate of this machine can super-size its, bringing an excessive energy consumption. Actually it's an important subject because we are in the age of lack of energy what turn it more expensive. So the correct sizing of a hydraulic pump is connected with the fact that you have to uses the enough energy resources avoiding waste. The calculate of ideal pump in the pumping system is studied during years and a lot of specialists in this subject develop equations and theories to calculate its. Some researches study about this subject and all of them become to the same conclusion: to find the ideal pump we have to know the characteristics of fluid (cinematic viscosity), the required flow , overall yield (overall of motor x overall of pump) the high gauge or discharge pressure and the loss of repression. The pressure drop can be calculated with different theories: using Hazen-Williams, Darcy e Weisbach or Chézy (1775 - that starts the researches to calculate the pressure drop). Although the most used theory and what is most near to reality is the Darcy's equation. So, in this job the Darcy's equation were choice to calculate the drop pressure that consider what kind of flow we are studying: laminar or turbulent. The determination of the best pump to be used in the ... ( complete abstract click eletronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study and selection of an equipment of air conditioner for any type of environment, should be made without overestimate or undersizing the project. The undersizing does not provide an adequate comfort temperature if the environment is too hot because the air conditioner does not remove all the heat necessary in the environment. But if the project is oversized, energy consumption is higher and there is an unnecessary cost. To prevent these failures is necessary to make a calculation of the thermal load on the environment and choose the equipment that has a higher cooling capacity than the calculated heat load and closer to the calculated heat load. In this graduate work will be chosen an air-conditioned equipment for bus, showing the calculations made for the thermal load for various types of heat gain in this type of vehicle. The thermal load on vehicles is more complicated to calculate than in areas because there are several factors that vary with the movement of the vehicle. It will also explain the compression refrigeration cycle, which is the cooling system used in vehicles because it is weightless, compact and lower cost. From the calculated heat load, it will be chosen an air conditioner that best suits the project and, finally, a brief presentation of the selected equipment will be made

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente estudo, que foi desenvolvido considerando os dados de quatro municípios do Estado de São Paulo (São Carlos, Araraquara, Matão e Gavião Peixoto), teve como propósito definir um Indicador de Desenvolvimento Regional e teve os seguintes itens pesquisados: consumo energia elétrica residencial e industrial, população, valor adicionado total e o número de empregos gerados. Desses itens foram utilizados o valor adicionado e o número de empregos gerados para definir um indicador de desenvolvimento regional a fim de detectar o desenvolvimento dos municípios estudados, utilização de mão de obra qualificada e a geração de riquezas obtidas e distribuída entre esses municípios. A construção desse Indicador teve como base os dados dos municípios paulistas do período de 2001 a 2007. Após a mensuração do indicador de desenvolvimento regional foram extraídos e analisados os seguintes dados: análise do crescimento desses indicadores que levam ao desenvolvimento dos municípios vizinhos e a formação de um agrupamento produtivo local (cluster). Esses dados também foram utilizados numa análise estatística de regressão para estimar previsão de crescimento desses municípios em função do setor aeronáutico que está se instalando na região estudada. Foi observado também que no período estudado houve um crescimento de consumo de energia elétrica industrial e residencial, propiciando aos seus habitantes uma melhor qualidade de vida, com melhores salários e benefícios comuns. Esse indicador é altamente favorável, pois evidencia que a tendência de agrupamento de empresas no mesmo setor, contribui para o desenvolvimento da sociedade onde está inserida, incentiva o crescimento dos municípios e fomentando as atividades. No período de 2001 a 2005, os municípios de Araraquara, Gavião Peixoto e São Carlos tiveram um crescimento no indicador, de maneira estável... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The materials designed to be used in electroluminescent (EL) devices construction are studied and improved since 1936. Great interests in the development of this kind of devices are mainly due to its low power consumption, flexibility, low cost and easy processing. One class of ELs devices with these characteristics are produced by employing a organic-polymeric/inorganic composite from a conductive polymer blend and an inorganic electroluminescent material (Zn2SiO4:Mn) dispersed in the polymeric matrix. This kind of device operates in d.c. or a.c. potentials, with EL of hundreds candela in the green region of the visible spectrum. However, few studies on the light emission were performed for these devices. In order to characterize devices made from composites, in this work is proposed a method of characterizing the electroluminescence associated with the impedance spectroscopy technique. To implement the technique of impedance spectroscopy was employ an experimental setup consisting of a source of a.c. voltage, an oscilloscope, and a reference resistor. Associated with this system, was use a photo diode and an analog electrometer to characterize the emitted light signal from the sample. The system was implemented allows characterization by impedance spectroscopy in the frequency range from 0.2 Hz up to 2 MHz and voltage amplitudes of 5 mV up to 20 kV. This system permits, at the same time, measurement of the RMS value of the luminance for devices in frequency range from 20 Hz up to 2 MHz. To test the system efficiency, an EL device was characterized showing analogous results to those reported in literature. By doing this, was demonstrated the efficiency of the system for electroluminescence characterization associated with the electrical characterization by impedance spectroscopy, for devices

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solar energy can be considered the largest source of energy available on earth and has attracted in recent decades, attention and interest for its rational use. The use of energy sources in a sustainable manner is essential to the survival of future generations, due to the scarcity of natural resources and their exploitation in a disorderly way. Studies related to the applications of renewable sources becomes then relevant, given its great importance as regards the conscious use of resources provided by nature, with the least possible impact on it. The present study presents an evaluation of generation potential and feasibility of implementing a solar photovoltaic connected to the grid and connected to the roofs of some buildings of the Faculty of Engineering of Guaratinguetá - FEG, to supply the demand of electric energy consumption on campus and attempting to inject a possible surplus power generation in local power grid, increasing network capacity and reducing peak loads

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last decades it has been observed a substantial developing of the electrical energy demand in the societies all over the World. In consequence the electrical energy distribution companies are increasing the quantity of electrical energy through the electrical energy conductor cables, which had grown the sag in the towers of energy transmission. Furthermore, the construction of more transmission towers brings a lot of troubles due environmental protection laws. In this way, looking forward to increase the quantity of electrical energy transmitted through electrical cables conductors, reduce the need of constructing new transmission towers and the sag in them, we suggest in this work the replace of the traditional core of the conductors cables commonly used, made of steel, by a core made by a composite material, which one is made by carbon fibers pultruded with polymeric resins as matrix. In a order to evaluate if the resins more commonly used in structural composites can be applied as matrix to make possible to use the composite material as a core, we made carbon fibers systems pultruded with epoxy, phenolic and polyester resins as matrix and a mechanic and physic-chemistry characterization was done on the systems by Tensile and Poisson tests, differential sprobe calorimetry (DSC), thermogravimetric analysis (TGA) and Fourier transformed infrared spectroscopy (FTIR), following their correspondents standards

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solar energy can be considered the largest source of energy available on earth and has attracted in recent decades, attention and interest for its rational use. The use of energy sources in a sustainable way is essential to the survival of future generations, due to the scarcity of natural resources and their exploitation in a disorderly way. This academic work aims to bring a possible alternative to reduce the consumption of eletrical energy, at the University of Engineering – Campus of Guaratinguetá, through the use of a photovoltaic system interconnected to the LED bulbs. For this, the necessary data for the design of the photovoltaic system componentes and their acquisition costs were obtained and three differents configurations were developed to choose the one that bests fits the studied case, considering the return time of the initial investment (payback)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cassava wastewater, generated during the cassava processing, is a pollutant and toxic waste. This study compared the efficiency of the cassava wastewater treatment in three batch aerobic systems with a ru1nning time of 24 hours, and aeration stoppage of 12h with 2,500, 6,000 and 10,000 mg COD L-1 . The systems were evaluated for COD, pH, SVI and F/M. The results showed that the reactor with aeration stoppage for 12 hours, with 2,500 mg COD L-1 , presented the best reduction in a process with considerable energy consumption saving compared to traditional continuous systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reason of this work is perform a study about using of electrical energy to identify the opportunities through rational use of electrical energy. For that it was necessary perform an analysis of hired energy against consumption. Based in a guide of energy analysis were found the main consumers and verified the main problems, which generate excessive use of electrical energy in a plastic injection factory. It was also analyzed the painting line because there are some thermal equipment that use electrical energy. Based on the data obtained will be proposed ways to reduce the needless consumption and energy use of rationally and efficiently, in addition to re-evaluate the contracted demand based on the new policy of supplying and charging.It were also proposed thermodynamics solutions to reduce the energy consumed in thermal process

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses methods of reducing the electric energy consumption on residences by the means of constructive measures and replacement of electric devices. Analyzing their impacts on residential and national level based on data issued by IBGE (Brazilian Institute of Geography and Statistics) and PROCEL (National Program for Electricity Conservation).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work develops a residential automation system controlled by PIC microcontroller connected to a domestic network using the TCP/IP protocol. This was motivated by the viability of building an automation system to control basic elements of a house with low cost, which cannot be found nowadays. Initially is presented a brief history of the automation systems and an introduction about PIC microcontrollers. Afterwards is presented an overview of the system to be implemented. Then it is shown a suggested circuit and the sensor and actuator elements as well as the software to manage the system, this was all build and test in the laboratory. In the end are the results obtained from the prototype, like the energy consumption, the cost, efficiency and reliability

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FCAV