998 resultados para COLUMN-SWITCHING TECHNIQUE
Resumo:
The strong influence of the winter North Atlantic Oscillation (NAO) on the total ozone column (TOC) in the Northern Hemisphere has been reported in a number of previous studies. In this study we show that this influence is not restricted to the winter season but is also significant in summer. Especially interesting effects of the summer NAO (SNAO) on the TOC are observed over the eastern Mediterranean region, where a strongly positive SNAO index is related to the creation of a geopotential height-negative anomaly over Greece with maximum amplitude at 200 hPa. Another anomaly was observed west of the Iberian Peninsula with similar effects on the TOC. Analyzing 26 years of Total Ozone Mapping Spectrometer (TOMS) and Ozone Monitoring Instrument (OMI) data from the equator to midlatitudes (60°) in the Northern Hemisphere, we demonstrate that the SNAO accounts for up to 30% of the TOC variability with a strong latitudinal and longitudinal dependence. Additionally, we obtain significant correlations between the NAO index and the thermal tropopause pressure and also with the geopotential heights at 200 and 500 hPa. Finally, some indirect connections between NAO and the TOC through teleconnections are also discussed.
Resumo:
In this paper we propose the use of the independent component analysis (ICA) [1] technique for improving the classification rate of decision trees and multilayer perceptrons [2], [3]. The use of an ICA for the preprocessing stage, makes the structure of both classifiers simpler, and therefore improves the generalization properties. The hypothesis behind the proposed preprocessing is that an ICA analysis will transform the feature space into a space where the components are independent, and aligned to the axes and therefore will be more adapted to the way that a decision tree is constructed. Also the inference of the weights of a multilayer perceptron will be much easier because the gradient search in the weight space will follow independent trajectories. The result is that classifiers are less complex and on some databases the error rate is lower. This idea is also applicable to regression
Resumo:
La surveillance financière contemporaine est toute entière associée à la volonté de tirer avantage des technologies de l'information et de la communication dans le but d'identifier et de suivre les flux de capitaux au nom de la lutte contre le blanchiment d'argent et le financement du terrorisme. Légitimées pour éviter tout blocage abrupt des mobilités, les techniques destinées à financer ces flux tendent à cadrer la circulation financière. Leur mise en place crée des obligations pour de nombreux acteurs économiques érigés en filtres protecteurs de l'architecture financière internationale. L'importance de cette logique de traçabilité a été amplifiée au lendemain des attentats du 11 septembre 2001, avec une stigmatisation accrue de tout ce qui n'est pas "traçable". L'objectif de cet article est précisément d'éclairer cette articulation entre promotion de la traçabilité et effets de stigmatisation dans un contexte bien précis de "panique morale" et de mise en priorité des problématiques antiterroristes. Le traitement réservé aux systèmes informels de transfert d'argent, souvent regroupés de manière abusive sous le terme <i>hawala</i>, en est l'exemple frappant.
Resumo:
Low-copy-number molecules are involved in many functions in cells. The intrinsic fluctuations of these numbers can enable stochastic switching between multiple steady states, inducing phenotypic variability. Herein we present a theoretical and computational study based on Master Equations and Fokker-Planck and Langevin descriptions of stochastic switching for a genetic circuit of autoactivation. We show that in this circuit the intrinsic fluctuations arising from low-copy numbers, which are inherently state-dependent, drive asymmetric switching. These theoretical results are consistent with experimental data that have been reported for the bistable system of the gallactose signaling network in yeast. Our study unravels that intrinsic fluctuations, while not required to describe bistability, are fundamental to understand stochastic switching and the dynamical relative stability of multiple states.
Resumo:
OBJECTIVE: Skeletal Muscle Biopsy is a minor surgical procedure for the diagnosis of different neuromuscular pathological conditions and has recently gained popularity also in the research field of age-related muscular modifications and sarcopenia. Few studies focused on the application of mini-invasive muscular biopsy in both normal and pathological conditions. The aim of our study was to describe a mini invasive ultrasound-guided skeletal muscular biopsy technique in complete spinal cord injured (SCI) patients and healthy controls with a tri-axial end-cut needle. PATIENTS AND METHODS: Skeletal muscle biopsies were collected from 6 chronic SCI patients and 3 healthy controls vastus lateralis muscle with a tri-axial end cut needle (Biopince© - Angiotech). Muscle samples were stained for ATPase to determine fibers composition, moreover, gene expression of cyclooxygenase-1 (COX-1) and prostaglandin E2 receptor has been analyzed by Real Time RT-PCR. RESULTS: All the procedures were perfomed easily without failures and complications. Control tissue was macroscopically thicker than SCI one. Control specimen displayed an equal distribution of type I and type II fibers, while SCI sample displayed a prevalence of type II fibers SCI specimen displayed a significant reduction in COX-1 gene expression. This mini-invasive approach was easy, accurate and with low complication rate in performing skeletal muscle biopsy in both SCI patients and controls. CONCLUSIONS: This technique could be useful in conditions in which the overall quantity of specimen required is small like for molecular biology analysis. For histological diagnostic purposes and/or conditions in which the original tissue is already pathologically modified, this technique should be integrated with more invasive techniques.
Resumo:
Hydrogenated nanocrystalline silicon (nc-Si:H) obtained by hot-wire chemical vapour deposition (HWCVD) at low substrate temperature (150 °C) has been incorporated as the active layer in bottom-gate thin-film transistors (TFTs). These devices were electrically characterised by measuring in vacuum the output and transfer characteristics for different temperatures. The field-effect mobility showed a thermally activated behaviour which could be attributed to carrier trapping at the band tails, as in hydrogenated amorphous silicon (a-Si:H), and potential barriers for the electronic transport. Trapped charge at the interfaces of the columns, which are typical in nc-Si:H, would account for these barriers. By using the Levinson technique, the quality of the material at the column boundaries could be studied. Finally, these results were interpreted according to the particular microstructure of nc-Si:H.
Resumo:
There are few clinical data on the combination abacavir/lamivudine plus raltegravir. We compared the outcomes of patients from the SPIRAL trial receiving either abacavir/lamivudine or tenofovir/emtricitabine at baseline who had taken at least one dose of either raltegravir or ritonavir-boosted protease inhibitors. For the purpose of this analysis, treatment failure was defined as virological failure (confirmed HIV-1 RNA ≥50 copies/ml) or discontinuation of abacavir/lamivudine or tenofovir/emtricitabine because of adverse events, consent withdrawal, or lost to follow-up. There were 143 (72.59%) patients with tenofovir/emtricitabine and 54 (27.41%) with abacavir/lamivudine. In the raltegravir group, there were three (11.11%) treatment failures with abacavir/lamivudine and eight (10.96%) with tenofovir/emtricitabine (estimated difference 0.15%; 95% CI -17.90 to 11.6). In the ritonavir-boosted protease inhibitor group, there were four (14.81%) treatment failures with abacavir/lamivudine and 12 (17.14%) with tenofovir/emtricitabine (estimated difference -2.33%; 95% CI -16.10 to 16.70). Triglycerides decreased and HDL cholesterol increased through the study more pronouncedly with abacavir/lamivudine than with tenofovir/emtricitabine and differences in the total-to-HDL cholesterol ratio between both combinations of nucleoside reverse transcriptase inhibitors (NRTIs) tended to be higher in the raltegravir group, although differences at 48 weeks were not significant. While no patient discontinued abacavir/lamivudine due to adverse events, four (2.80%) patients (all in the ritonavir-boosted protease inhibitor group) discontinued tenofovir/emtricitabine because of adverse events (p=0.2744). The results of this analysis do not suggest that outcomes of abacavir/lamivudine are worse than those of tenofovir/emtricitabine when combined with raltegravir in virologically suppressed HIV-infected adults.
Resumo:
The present study proposes a method based on ski fixed inertial sensors to automatically compute spatio-temporal parameters (phase durations, cycle speed and cycle length) for the diagonal stride in classical cross-country skiing. The proposed system was validated against a marker-based motion capture system during indoor treadmill skiing. Skiing movement of 10 junior to world-cup athletes was measured for four different conditions. The accuracy (i.e. median error) and precision (i.e. interquartile range of error) of the system was below 6ms for cycle duration and ski thrust duration and below 35ms for pole push duration. Cycle speed precision (accuracy) was below 0.1m/s (0.005m/s) and cycle length precision (accuracy) was below 0.15m (0.005m). The system was sensitive to changes of conditions and was accurate enough to detect significant differences reported in previous studies. Since capture volume is not limited and setup is simple, the system would be well suited for outdoor measurements on snow.
Resumo:
PURPOSE: A surgical gastrostomy is mandatory in cases where a PEG is not feasible. Various minimally invasive techniques have been described, but many involve unusable materials in small children and/or have risk of disunion. We describe a technique for true Stamm gastrostomy performed by laparoscopy (LSG) with a purse string suture and four points of attachment onto the wall. METHOD: We reviewed 20 children who underwent an LSG from 2010 to 2013. After incision of the skin at the location planned for the gastrostomy, using three 3-5mm ports the stomach is fixed to the wall by three suspension stitches, which are entered and then emerged subcutaneously. A fourth stitch of attachment is used to make an award on the stomach and tie around the gastrostomy tube. RESULTS: Mean age was 4.2years, with 70% aged <2years. All children were malnourished, most often severely. All but two underwent a concomitant fundoplication. Feeding through the gastrostomy started on D0 or D1. Total feeding by gastrostomy was achieved in a mean duration of 2.9day. Mean hospital stay was 4.5days. There was no perioperative complication. Mean follow-up was 14months. Once, the balloon was accidently deflated and reinflated in the wall leading to its necrosis. Five peristomial granulomas were noticed. It was always possible to replace the tube by a gastrostomy device at least 6weeks after surgery. CONCLUSION: This new technique for true Stamm gastrostomy by laparoscopy reproduces exactly the one done by laparotomy, without special equipment. It can be made since the neonatal period, in all the circumstances when a laparoscopy is possible.
Annuaire de la papeterie française et étrangère (technique, industriel et commercial, fondé en 1865)
Resumo:
Variante(s) de titre : Annuaire général de la papeterie française et étrangère
Annuaire de la papeterie française et étrangère (technique, industriel et commercial, fondé en 1865)
Resumo:
1865 (A1).