948 resultados para Angular acceleration


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to diagnosis oral lesions related to HIV infection in individuals followed in the General Hospital of the School of Medicine of Ribeirao Preto, University of Sao Paulo, Brazil. The presence of oral lesions was correlated with gender, age, smoking habit, levels of CD4 lymphocytes, HIV load, time of HIV seropositivity, AIDS condition, use of removable dental prosthesis, and use of HAART. Materials and Methods: 340 HIV infected individuals were selected for this study, all participants of the study were examined by only one practiced dentist which performed anamnesis, peribuccal and oral examination. Results: Oral lesions were observed in 113 of 340 (33.2%) HIV infected individuals. These oral lesions included: oral candidiasis (17.7%) of pseudomembranous (10.8%) and of erythematous types (6.9%), angular cheilitis (13.9%), hairy leukoplakia (11.8%), and oral ulcers (2.1%). Oral candidiasis lesions were more frequently observed in women (p. 033). Smoking addict participants presented a high frequency of tongue hairy leukoplakia (p. 038) and a reduced frequency of oral ulcers (p. 018). Hairy leukoplakia and pseudomembranous candidiasis were inversely correlated to CD4+ L levels and directly correlated with HIV load, behaving as immune depression markers. Hairy leukoplakia and pseudomembranous candidiasis also showed an inverse correlation with HAART use (p < .0001). Patients using mobile dental prosthesis presented a high frequency of erythematous candidiasis (p. 003). Conclusion: The inverse correlation with CD4+ L level and the direct correlation with HIV load suggest that oral lesions could be used as alternative clinical markers for poor immune condition in HIV infected individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Twenty-three patients (median age 23 months) who underwent Fallot`s tetralogy repair were investigated prospectively to detect a possible association between histopathologic myocardial remodeling and echocardiographic findings of systolic or diastolic ventricular dysfunction. Methods: Intraoperatively resected infundibular bands and subendocardial biopsy samples from the right ventricle (RV) and left ventricle were obtained for histopathologic evaluation. Tissue Doppler echocardiographic interrogation of the ventricles was performed before surgery and in the postoperative period. Results: Histopathologic data revealed hypertrophy of the RV cardiomyocytes and increased interstitial collagen in both ventricles. Mean values of RV isovolumic acceleration decreased significantly at the third evaluation compared with the preoperative values (P = .006). RV myocardial fibrosis greater than 8.3% was associated with a probability of altered E` of at least 0.7 (odds ratio = 2.31). Conclusion: Preoperative histologic myocardial remodeling influenced the postoperative RV function in this group of patients with late repair. Further studies are necessary to evaluate the myocardium in younger patients and to define its influence in the long-term follow-up. (J Am Soc Echocardiogr 2010;23:912-8.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the oral status, salivary flow rate, Candida carriage in saliva, and prevalence of Candida albicans colonization in several areas of the mouth in patients with primary and secondary Sjogren`s syndrome as opposed to those of healthy subjects. Study design: Thirty-seven patients with Sjogren`s syndrome (SS), [14 patients with primary SS (SS-1) and 23 patients with secondary SS (SS-2)], along with 37 healthy controls were examined in regard to number of teeth, pro-bing pocket depth (PPD), approximal plaque index (API), bleeding on probing (BOP), presence of prosthetic appliances and smoking habits. Salivary flow rate (SFR), Candida carriage in saliva, presence of Candida albicans colonization on buccal, angular, palatal and sulcular areas, on dentures and on the tongue`s dorsal surface were determined. Statistical analyses were performed using the 2-tailed Fisher exact and Kruskal-Wallis test. Results: No statistically significant difference was found between SS-1 and SS-2 groups based on the parameters analysed. Statistically significant differences were observed between patients with SS and healthy subjects in terms of SFR, oral signs and symptoms, API, BOP, C. albicans colonization on tongue and buccal area, and Candida carriage in saliva. In the gingival crevicular fluid positive C. albicans colonization was found in only one subject of SS subgroup. Conclusions: SS patients carry a higher risk of having periodontitis and are more predisposed to develop candidiasis. C. albicans is scarcely detected in gingival crevicular fluid despite high scores on C. albicans colonization in different areas of the oral cavity in SS patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: In this study, we compared the dentoalveolar changes of Class II patients treated with Jones jig and pendulum appliances. Methods: The experimental group comprised 40 Class II malocclusion subjects, divided into 2 groups: group 1 consisted of 20 patients (11 boys, 9 girls) at a mean pretreatment age of 13.17 years, treated with the Jones jig appliance for 0.91 years; group 2 comprised 20 patients (8 boys, 12 grls) at a mean pretreatment age of 13.98 years, treated with the pendulum appliance for 1.18 years. Only active treatment time of molar distalization was evaluated in the predistalization and postdistalization lateral cephalograms. Molar, second premolar, and incisor angular and linear variables were obtained. The intergroup treatment changes in these variables were compared with independent t tests. Results: The maxillary second premolars showed greater mesial tipping and extrusion in the Jones jig group, indicating more anchorage loss during molar distalization with this appliance. The amounts and the monthly rates of molar distalization were similar in both groups. Conclusions: The Jones jig group showed greater mesial tipping and extrusion of the maxillary second premolars. The mean amounts and the monthly rates of first molar distalization were similar in both groups. (Am J Orthod Dentofacial Orthop 2009;135:336-42)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: In premolar extraction cases, root parallelism is recommended to preserve the stability of space closures. The influence of the degree of root parallelism on relapse of tooth extraction spaces has been a controversial topic in the literature. The aim of this study was to compare the angle between the long axes of the canine and the second premolarin patients with and without stability of extraction-space closures. Methods: A sample of 56 patients, treated with 4 premolar extractions, was divided into 2 groups: group 1, consisting of 25 patients with reopening of extraction spaces; and group 2, consisting of 31 patients without reopening of extraction spaces. Panoramic radiographs of each patient were analyzed at the posttreatment and 1-year posttreatment stages. The data were statistically analyzed by using chi-square tests, t tests, analysis of variance (ANOVA), and Pearson correlation coefficients. Results: The results showed that the groups did not differ regarding the angle between the canine and the second premolar, and there was no correlation between angular changes and reopening of extraction spaces, showing that dental angular changes are not determining factors for relapse, and other factors should be investigated. Conclusions: The final angle and the posttreatment changes observed in the angle between the long axes of the canine and the second premolar showed no influence on the relapse of extraction spaces. (Am J Orthod Dentofacial Orthop 2011; 139: e505-e510)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the increasing utilization of all-ceramic crown systems, their mechanical performance relative to that of metal ceramic restorations (MCR) has yet to be determined. This investigation tested the hypothesis that MCR present higher reliability over two Y-TZP all-ceramic crown systems under mouth-motion fatigue conditions. A CAD-based tooth preparation with the average dimensions of a mandibular first molar was used as a master die to fabricate all restorations. One 0.5-mm Pd-Ag and two Y-TZP system cores were veneered with 1.5 mm porcelain. Crowns were cemented onto aged (60 days in water) composite (Z100, 3M/ESPE) reproductions of the die. Mouth-motion fatigue was performed, and use level probability Weibull curves were determined. Failure modes of all systems included chipping or fracture of the porcelain veneer initiating at the indentation site. Fatigue was an acceleration factor for all-ceramic systems, but not for the MCR system. The latter presented significantly higher reliability under mouth-motion cyclic mechanical testing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to analyze if the presence of impacted third molars, and their positions in the mandibular angle, can change the bone quality in this area, considering the measure of the cortical thickness in this region as representative or not for mandible fracture risk. Software was used to analyze 50 digital images from panoramic radiographs of patients who had one or two impacted third molars in the mandible, and 30 digital images of patients with agenesis of the mandibular third molar. The thickness of the cortical region of the mandible was measured; it was possible to draw a parallel line to the posterior portion of the mandible and a parallel line to the body of this bone on each side of the image. At the intersection of these lines near the distal portion of the second molar, another line was set up to serve as reference in the cortical thickness measurement. It could be concluded that the cortical thickness of the mandibular angle in male patients without impacted third molars was greater than the thickness in patients with these teeth, and no difference in thickness was found for the female group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polarized absorption and emission spectra of trigonal single crystals of an Er(III) complex coordinated to a heptadentate tripodal ligand are reported at temperatures between 8 and 298 K. The assigned energy levels below the onset of ligand absorption (< 25 000 cm(-1)) are fitted to a parametrized electronic Hamiltonian. The C-3 site symmetry of the Er(HI) ion requires eight parameters for a full description of the ligand field within a one-electron operator description. This compound shows unusually large splittings of the multiplets, and the fitted parameters imply that this heptadentate ligand imparts the largest ligand field reported for an Er(III) complex. The ligand field was also interpreted within the angular overlap model (AOM). We derive the AOM matrix to include both sigma and anisotropic pi bonding and show that a useful description of the C-3 ligand field can be made using only five parameters. The success of the AOM description is encouraging for applications on isomorphous complexes within the lanthanide series and in describing the ligand field of low-symmetry complexes with less parameters than in the usual spherical harmonic expansion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We consider a possible technique for mode locking an atom laser, based on the generation of a dark soliton in a ring-shaped Bose-Einstein condensate, with repulsive atomic interactions. The soliton is a kink, with angular momentum per particle equal to (h) over bar /2. It emerges naturally when the condensate is stirred at the soliton velocity and cleansed with a periodic out coupler. The result is a replicating coherent field inside the atom laser, stabilized by topology. We give a numerical demonstration of the generation and stabilization of the soliton.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the effect of quantum interference on the population distribution and absorptive properties of a V-type three-level atom driven by two lasers of unequal intensities and different angular frequencies. Three coupling configurations of the lasers to the atom are analysed: (a) both lasers coupled to the same atomic transition, (b) each laser coupled to different atomic transition and (c) each laser coupled to both atomic transitions. Dressed stales for the three coupling configurations are identified, and the population distribution and absorptive properties of the weaker field are interpreted in terms of transition dipole moments and transition frequencies among these dressed states. In particular, we find that in the first two cases there is no population inversion between the bare atomic states, but the population can be trapped in a superposition of the dressed states induced by quantum interference and the stronger held. We show that the trapping of the population, which results from the cancellation of transition dipole moments, does not prevent the weaker field to be coupled to the cancelled (dark) transitions. As a result, the weaker field can be strongly amplified on transparent transitions. In the case of each laser coupled to both atomic transitions the population can be trapped in a linear superposition of the excited bare atomic states leaving the ground state unpopulated in the steady state. Moreover, we find that the absorption rate of the weaker field depends on the detuning of the strong field from the atomic resonances and the splitting between the atomic excited states. When the strong held is resonant to one of the atomic transitions a quasi-trapping effect appears in one of the dressed states. In the quasi-trapping situation all the transition dipole moments are different from zero, which allows the weaker field to be amplified on the inverted transitions. When the strong field is tuned halfway between the atomic excited states, the population is completely trapped in one of the dressed states and no amplification is found for the weaker field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on a proof of principle demonstration of an optically driven micromachine element. Optical angular momentum is transferred from a circularly polarized laser beam to a birefringent particle confined in an optical tweezers trap. The optical torque causes the particle to spin at up to 350 Hz, and this torque is harnessed to drive an optically trapped microfabricated structure. We describe a photolithographic method for producing the microstructures and show how a light driven motor could be used in a micromachine system. (C) 2001 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Growing evidence supports low-intensity pulsed ultrasound (US) as an osteogenic mechanical stimulus. Its effects on isolated bone cells and on fractured bone are established. However, its effects on osteoporosis are not clear. This study examined US effects on ovariectomy (OVX) induced bone changes within the rodent hindlimb (distal femur and proximal tibia), and on normal bone in animals following sham-OVX. Animals were exposed to daily unilateral active-US and contralateral inactive-US for 12 weeks. Bone status was assessed using dual energy X-ray absorptiometry and histomorphometry. Ovariectomy resulted in significant bone changes. Low-intensity pulsed US did not influence these changes. These results suggest that the US dose introduced may not be a beneficial treatment for osteoporosis, and that intact bone may be less sensitive to US than fractured bone and isolated bone cells. This may relate to the biophysical mechanisms of action of US, US-bone interactions and tissue level processes taking place.