916 resultados para All plastic device
Resumo:
Stations on Bus Rapid Transit (BRT) lines ordinarily control line capacity because they act as bottlenecks. At stations with passing lanes, congestion may occur when buses maneuvering into and out of the platform stopping lane interfere with bus flow, or when a queue of buses forms upstream of the station blocking inflow. We contend that, as bus inflow to the station area approaches capacity, queuing will become excessive in a manner similar to operation of a minor movement on an unsignalized intersection. This analogy was used to treat BRT station operation and to analyze the relationship between station queuing and capacity. We conducted microscopic simulation to study and analyze operating characteristics of the station under near steady state conditions through output variables of capacity, degree of saturation and queuing. In the first of two stages, a mathematical model was developed for all stopping buses potential capacity with bus to bus interference and the model was validated. Secondly, a mathematical model was developed to estimate the relationship between average queue and degree of saturation and calibrated for a specified range of controlled scenarios of mean and coefficient of variation of dwell time.
Resumo:
The desire to solve problems caused by socket prostheses in transfemoral amputees and the acquired success of osseointegration in the dental application has led to the introduction of osseointegration in the orthopedic surgery. Since its first introduction in 1990 in Gothenburg Sweden the osseointegrated (OI) orthopedic fixation has proven several benefits[1]. The surgery consists of two surgical procedures followed by a lengthy rehabilitation program. The rehabilitation program after an OI implant includes a specific training period with a short training prosthesis. Since mechanical loading is considered to be one of the key factors that influence bone mass and the osseointegration of bone-anchored implants, the rehabilitation program will also need to include some form of load bearing exercises (LBE). To date there are two frequently used commercially available human implants. We can find proof in the literature that load bearing exercises are performed by patients with both types of OI implants. We refer to two articles, a first one written by Dr. Aschoff and all and published in 2010 in the Journal of Bone and Joint Surgery.[2] The second one presented by Hagberg et al in 2009 gives a very thorough description of the rehabilitation program of TFA fitted with an OPRA implant. The progression of the load however is determined individually according to the residual skeleton’s quality, pain level and body weight of the participant.[1] Patients are using a classical bathroom weighing scale to control the load on the implant during the course of their rehabilitation. The bathroom scale is an affordable and easy-to-use device but it has some important shortcomings. The scale provides instantaneous feedback to the patient only on the magnitude of the vertical component of the applied force. The forces and moments applied along and around the three axes of the implant are unknown. Although there are different ways to assess the load on the implant for instance through inverse dynamics in a motion analysis laboratory [3-6] this assessment is challenging. A recent proof- of-concept study by Frossard et al (2009) showed that the shortcomings of the weighing scale can be overcome by a portable kinetic system based on a commercial transducer[7].
Resumo:
The consequences of falls are often dreadful for individuals with lower limb amputation using bone-anchored prosthesis.[1-5] Typically, the impact on the fixation is responsible for bending the intercutaneous piece that could lead to a complete breakage over time. .[3, 5-8] The surgical replacement of this piece is possible but complex and expensive. Clearly, there is a need for solid data enabling an evidence-based design of protective devices limiting impact forces and torsion applied during a fall. The impact on the fixation during an actual fall is obviously difficult to record during a scientific experiment.[6, 8-13] Consequently, Schwartze and colleagues opted for one of the next best options science has to offer: simulation with an able-bodied participant. They recorded body movements and knee impacts on the floor while mimicking several plausible falling scenarios. Then, they calculated the forces and moments that would be applied at four levels along the femur corresponding to amputation heights.[6, 8-11, 14-25] The overall forces applied during the falls were similar regardless of the amputation height indicating that the impact forces were simply translated along the femur. As expected, they showed that overall moments generally increased with amputation height due to changes in lever arm. This work demonstrates that devices preventing only against force overload do not require considering amputation height while those protecting against bending moments should. Another significant contribution is to provide, for the time, the magnitude of the impact load during different falls. This loading range is crucial to the overall design and, more precisely, the triggering threshold of protective devices. Unfortunately, the analysis of only a single able-bodied participant replicating falls limits greatly the generalisation of the findings. Nonetheless, this case study is an important milestone contributing to a better understanding of load impact during a fall. This new knowledge will improve the treatment, the safe ambulation and, ultimately, the quality of life of individuals fitted with bone-anchored prosthesis.
Resumo:
The concept of specificity of exercise prescription and training is a longstanding and widely accepted foundation of the exercise sciences. Simply, the principle holds that training adaptations are achieved relative to the stimulus applied. That is, the manipulation of training variables (e.g. intensity or loading, mode, volume and frequency) directly influences the acute training stimulus, and so the long-term adaptive response (Young et al., 2001; Bird et al., 2005). Translating this concept to practice then recommends that exercise be prescribed specific to the desired outcomes, and the more closely this is achieved, the greater the performance gain is likely to be. However, the cardiovascular and metabolic adaptations traditionally associated with long, slow distance training types, similarly achieved using high-intensity training methods (for a review see Gibala et al., 2012), highlights understanding of underlying physiology as paramount for effective training program design. Various other factors including illness, sleep and psychology also impact on the training stimulus (Halson, 2014) and must be managed collectively with appropriate post-exercise recovery to continue performance improvements and reduce overtraining and injury risks (Kenttä and Hassmén, 1998).
Resumo:
PURPOSE To assess the performance of the 2Win eccentric videorefractor in relation to subjective refraction and table-mounted autorefraction. METHODS Eighty-six eyes of 86 adults (46 male and 40 female subjects) aged between 20 and 25 years were examined. Subjective refraction and autorefraction using the table-mounted Topcon KR8800 and the handheld 2Win videorefractor were carried out in a randomized fashion by three different masked examiners. Measurements were repeated about 1 week after to assess instrument reproducibility, and the intertest variability was compared between techniques. Agreement of the 2Win videorefractor with subjective refraction and autorefraction was assessed for sphere and for cylindrical vectors at 0 degrees (J0) and 45 degrees (J45). RESULTS Reproducibility coefficients for sphere values measured by subjective refraction, Topcon KR8800, and 2Win (±0.42, ±0.70, and ±1.18, respectively) were better than their corresponding J0 (±1.0, ±0.85, and ±1.66) and J45 (±1.01, ±0.87, and ±1.31) vector components. The Topcon KR8800 showed the most reproducible values for mean spherical equivalent refraction and the J0 and J45 vector components, whereas reproducibility of spherical component was best for subjective refraction. The 2Win videorefractor measurements were the least reproducible for all measures. All refractive components measured by the 2Win videorefractor did not differ significantly from those of subjective refraction, in both sessions (p > 0.05). The Topcon KR8800 autorefractometer and the 2Win videorefractor measured significantly more positive spheres and mean spherical equivalent refraction (p < 0.0001), but the J0 and J45 vector components were similar (p > 0.05), in both sessions. CONCLUSIONS The 2Win videorefractor compares well, on average, with subjective refraction. The reproducibility values for the 2Win videorefractor were considerably worse than either subjective refraction or autorefraction. The wide limits of reproducibility of the 2Win videorefractor probably limit its usefulness as a primary screening device.
Resumo:
Achieving the combination of delayed and immediate release of a vaccine from a delivery device without applying external triggers remains elusive in implementing single administration vaccination strategies. Here a means of vaccine delivery is presented, which exploits osmosis to trigger delayed burst release of an active compound. Poly(-caprolactone) capsules of 2 mm diameter were prepared by dip-coating, and their burst pressure and release characteristics were evaluated. Burst pressures (in bar) increased with wall thickness (t in mm) following Pburst = 131.t + 3.4 (R2 = 0.93). Upon immersion in PBS, glucose solution-filled capsules burst after 8.7 ± 2.9 days. Copolymers of hydrophobic -caprolactone and hydrophilic polyethylene glycol were synthesized and their physico-chemical properties were assessed. With increasing hydrophilic content, the copolymer capsules showed increased water uptake rates and maximum weight increase, while the burst release was earlier: 5.6 ± 2.0 days and 1.9 ± 0.2 days for 5 and 10 wt% polyethylene glycol, respectively. The presented approach enables the reproducible preparation of capsules with high versatility in materials and properties, while these vaccine delivery vehicles can be prepared separately from, and independently of the active compound.
Resumo:
Purpose This study aimed to determine the feasibility and acceptability of actigraphy to monitor sleep quality and quantity in healthy self-rated good sleeper adults at home-based settings. Method Sixteen healthy volunteers (age > 18) were invited to participate. Each participant was provided with a wrist actigraph device to be worn for 24-hour/day for seven consecutive days to monitor their sleep-wake patterns. Actigraphy data were downloaded using-proprietary software to generate an individual-sleep report. Participants also completed a set of self-reported Health Related Quality of Life (HRQOL) using WHO (five) Well Being Index (WBI) questionnaires. Results Actigraphy was well accepted by all participants. Only 43.8% of the participants achieved normal total sleep time (TST) and 62.5% had a mean sleep efficiency value below the normal range. Despite a reduced quality of sleep among the participants, the self-reported HRQOL scores produced by the WHO-5 WBI showed a “fair” to “good” among the participants. Conclusions To maintain healthy well-being, it is vital to have efficient and quality sleep. Insufficient and poor sleep may contribute to various health problems and hazardous outcomes. People often believe they have normal and efficient sleep, not realising they may be developing poor sleep habits. This study found that actigraphy can be easily utilized to monitor sleep-wake patterns at home-based settings. We proposed that actigraphy could be adapted for use in the primary care settings (e.g. community pharmacy) to improve the sleep health management in the community.
Resumo:
By taking the advantage of the excellent mechanical properties and high specific surface area of graphene oxide (GO) sheets, we develop a simple and effective strategy to improve the interlaminar mechanical properties of carbon fiber reinforced plastic (CFRP) laminates. With the incorporation of graphene oxide reinforced epoxy interleaf into the interface of CFRP laminates, the Mode-I fracture toughness and resistance were greatly increased. The experimental results of double cantilever beam (DCB) tests demonstrated that, with 2 g/m2 addition of GO, the Mode-I fracture toughness and resistance of the specimen increase by 170.8% and 108.0%, respectively, compared to those of the plain specimen. The improvement mechanisms were investigated by the observation of fracture surface with scanning electron microscopies. Moreover, finite element analyses were performed based on the cohesive zone model to verify the experimental fracture toughness and to predict the interfacial tensile strength of CFRP laminates.
Resumo:
This report provides a qualitative evaluation of Unmanned Aircraft Systems (UAS) and on-board sensor technology for use in plant biosecurity in the Australian context. The more general term UAS describes both the Unmanned Aerial Vehicle (UAV) and all supporting components required to operate it. This may include a ground station, operator or pilot, and a launch and recovery device for example. The focus is to identify how and under what circumstances UAS may be useful for plant biosecurity. This can be used to help guide future decisions regarding investment in UAS for plant biosecurity.
Resumo:
Background The capacity to diagnosys, quantify and evaluate movement beyond the general confines of a clinical environment under effectiveness conditions may alleviate rampant strain on limited, expensive and highly specialized medical resources. An iPhone 4® mounted a three dimensional accelerometer subsystem with highly robust software applications. The present study aimed to evaluate the reliability and concurrent criterion-related validity of the accelerations with an iPhone 4® in an Extended Timed Get Up and Go test. Extended Timed Get Up and Go is a clinical test with that the patient get up from the chair and walking ten meters, turn and coming back to the chair. Methods A repeated measure, cross-sectional, analytical study. Test-retest reliability of the kinematic measurements of the iPhone 4® compared with a standard validated laboratory device. We calculated the Coefficient of Multiple Correlation between the two sensors acceleration signal of each subject, in each sub-stage, in each of the three Extended Timed Get Up and Go test trials. To investigate statistical agreement between the two sensors we used the Bland-Altman method. Results With respect to the analysis of the correlation data in the present work, the Coefficient of Multiple Correlation of the five subjects in their triplicated trials were as follows: in sub-phase Sit to Stand the ranged between r = 0.991 to 0.842; in Gait Go, r = 0.967 to 0.852; in Turn, 0.979 to 0.798; in Gait Come, 0.964 to 0.887; and in Turn to Stand to Sit, 0.992 to 0.877. All the correlations between the sensors were significant (p < 0.001). The Bland-Altman plots obtained showed a solid tendency to stay at close to zero, especially on the y and x-axes, during the five phases of the Extended Timed Get Up and Go test. Conclusions The inertial sensor mounted in the iPhone 4® is sufficiently reliable and accurate to evaluate and identify the kinematic patterns in an Extended Timed Get and Go test. While analysis and interpretation of 3D kinematics data continue to be dauntingly complex, the iPhone 4® makes the task of acquiring the data relatively inexpensive and easy to use.
Resumo:
Teaching Resource material prepared for DLB320 Landscape Horticulture, available to wider group of users via ePrints.
Resumo:
Teaching Resource materials prepared for DLB320 Landscape Horticulture (2015). CONTENTS 2 Old Brisbane Botanic Gardens Samples 3 Australian ICONS 4 Old Fashioned & Reliable 5 Palms & Bamboo 6 Cordylines & Dracaenas 7 Bromeliads & Succulents 8 Toxic & Poisonous Plants 9 Dangerous & Dirty Plants 10 Weeds, Pests & Diseases 11 Useful (Economic) Plants
Resumo:
Although kimberlite pipes/bodies are usually the remains of volcanic vents, in-vent deposits, and subvolcanic intrusions, the terminology used for kimberlite rocks has largely developed independently of that used in mainstream volcanology. Existing kimberlite terminology is not descriptive and includes terms that are rarely used, used differently, and even not used at all in mainstream volcanology. In addition, kimberlite bodies are altered to varying degrees, making application of genetic terminology difficult because original components and depositional textures are commonly masked by alteration. This paper recommends an approach to the terminology for kimberlite rocks that is consistent with usage for other volcanic successions. In modern terrains the eruption and emplacement origins of deposits can often be readily deduced, but this is often not the case for old, variably altered and deformed rock successions. A staged approach is required whereby descriptive terminology is developed first, followed by application of genetic terminology once all features, including the effects of alteration on original texture and depositional features, together with contact relationships and setting, have been evaluated. Because many volcanic successions consist of both primary volcanic deposits as well as volcanic sediments, terminology must account for both possibilities.
Resumo:
This descriptive correlational study examined relationships between mild stroke functional and psychosocial outcomes over the early post-discharge period among dyads of mild stroke patients (n=38) and their spousal caregivers (n=38). We measured patients' functional scores using the modified Rankin Scale; patients' and caregivers' quality of life (QoL) using Stroke Impact Scale and Short-Form 36 respectively, mood using the Beck Depression Inventory-II, and marital function scores using the Family Assessment Device. Spousal caregivers also completed the Bakas Caregiving Outcomes Scale as a measure of caregiver strain. The average age of stroke patients was 64 years and of spousal caregivers 58 years. All stroke patients were male; all spousal caregivers female. At three months post discharge, patient functional status scores had significantly improved from discharge (p=0.026) with a corresponding increase in QoL scores (p=0.012). Functional status was significantly correlated with patient perceptions of QoL at three months (r=.014, p=0.024) and spousal caregiver perceptions of physical domain QoL (r=.-.397, p=0.014). Spousal caregivers' mood at three months post discharge was strongly correlated with their perceptions of marital satisfaction (r=.578, p=0.000) and caregiver strain (r=-.620, p=0.000). In preparing patients for discharge following mild stroke, nurses must consider the psychological and social implications of the recovery process over time for both the patient with stroke and their spousal caregivers.