637 resultados para Aberración intraocular


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To provide a consistent standard for the evaluation of different types of presbyopic correction. SETTING: Eye Clinic, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Presbyopic corrections examined were accommodating intraocular lenses (IOLs), simultaneous multifocal and monovision contact lenses, and varifocal spectacles. Binocular near visual acuity measured with different optotypes (uppercase letters, lowercase letters, and words) and reading metrics assessed with the Minnesota Near Reading chart (reading acuity, critical print size [CPS], CPS reading speed) were intercorrelated (Pearson product moment correlations) and assessed for concordance (intraclass correlation coefficients [ICC]) and agreement (Bland-Altman analysis) for indication of clinical usefulness. RESULTS: Nineteen accommodating IOL cases, 40 simultaneous contact lens cases, and 38 varifocal spectacle cases were evaluated. Other than CPS reading speed, all near visual acuity and reading metrics correlated well with each other (r>0.70, P<.001). Near visual acuity measured with uppercase letters was highly concordant (ICC, 0.78) and in close agreement with lowercase letters (+/- 0.17 logMAR). Near word acuity agreed well with reading acuity (+/- 0.16 logMAR), which in turn agreed well with near visual acuity measured with uppercase letters 0.16 logMAR). Concordance (ICC, 0.18 to 0.46) and agreement (+/- 0.24 to 0.30 logMAR) of CPS with the other near metrics was moderate. CONCLUSION: Measurement of near visual ability in presbyopia should be standardized to include assessment of near visual acuity with logMAR uppercase-letter optotypes, smallest logMAR print size that maintains maximum reading speed (CPS), and reading speed. J Cataract Refract Surg 2009; 35:1401-1409 (C) 2009 ASCRS and ESCRS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. To evaluate the haemodynamic features of young healthy myopes and emmetropes, in order to ascertain the perfusion profile of human myopia and its relationship with axial length prior to reaching a degenerative state. Methods The retrobulbar, microretinal and pulsatile ocular blood flow (POBF) of one eye of each of twenty-two high myopes (N=22, mean spherical equivalent (MSE) =-5.00D), low myopes (N=22, MSE-1.00 to-4.50D) and emmetropes (N=22, MSE±0.50D) was analyzed using color Doppler Imaging, Heidelberg retinal flowmetry and ocular blood flow analyser (OBF) respectively. Intraocular pressure, axial length (AL), systemic blood pressure, and body mass index were measured. Results. When compared to the emmetropes and low myopes, the AL was greater in high myopia (p<0.0001). High myopes showed higher central retinal artery resistance index (CRA RI) (p=0.004), higher peak systolic to end diastolic velocities ratio (CRA ratio) and lower end diastolic velocity (CRA EDv) compared to low myopes (p=0.014, p=0.037). Compared to emmetropes, high myopes showed lower OBFamplitude (OBFa) (p=0.016). The POBF correlated significantly with the systolic and diastolic blood velocities of the CRA (p=0.016, p=0.036). MSE and AL correlated negatively with OBFa (p=0.03, p=0.003), OBF volume (p=0.02, p<0.001), POBF (p=0.01, p<0.001) and positively with CRA RI (p=0.007, p=0.05). Conclusion. High myopes exhibited significantly reduced pulse amplitude and CRA blood velocity, the first of which may be due to an OBF measurement artefact or real decreased ocular blood flow pulsatility. Axial length and refractive error correlated moderately with the ocular pulse and with the resistance index of the CRA, which in turn correlated amongst themselves. It is hypothesized that the compromised pulsatile and CRA haemodynamics observed in young healthy myopes is an early feature of the decrease in ocular blood flow reported in pathological myopia. Such vascular features would increase the susceptibility for vascular and age-related eye diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To evaluate the effect of latanoprost 0.005% on the optic nerve head (ONH) and retinal circulation of newly diagnosed and previously untreated primary open-angle glaucoma (POAG) patients. Methods Twenty-two newly diagnosed and previously untreated POAG patients (mean age±SD: 68.38±11.92 years) were included in this longitudinal open-label study. Patients were treated with latanoprost 0.005% once a day. Intraocular pressure (IOP), systemic blood pressure (BP), mean ocular perfusion pressure (MOPP), and ocular perfusion parameters ‘volume’, ‘velocity’, and ‘flow’ measured at the optic nerve head (ONH) and retina by means of Heidelberg Retina Flowmeter system were evaluated during a 6-month follow-up period. Results Treatment with latanoprost 0.005% resulted in a significant decrease in IOP (P<0.0001) and increase in MOPP (P<0.0001). After correcting for changes in MOPP, the blood velocity measured at the ONH level was significantly higher after 6 months of treatment than at baseline (P=0.0310). In addition, blood volume and flow measured at the peripapillary retina level improved after 3 and 6 months of treatment (P=0.0170; P=0.0260, and P=0.0170; P=0.0240 respectively). Conclusion Previously untreated POAG patients exhibit reduced IOP, increased MOPP and improved ocular perfusion at the ONH and retina levels when treated with Latanoprost 0.005%. These effects could be beneficial for glaucoma patients suffering from ocular vascular dysregulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to investigate the influence of corneal topography and thickness on intraocular pressure (IOP) and pulse amplitude (PA) as measured using the Ocular Blood Flow Analyzer (OBFA) pneumatonometer (Paradigm Medical Industries, Utah, USA). Methods. 47 university students volunteered for this cross-sectional study: mean age 20.4 yrs, range 18 to 28 yrs; 23 male, 24 female. Only the measurements from the right eye of each participant were used. Central corneal thickness and mean corneal radius were measured using Scheimpflug biometry and corneal topographic imaging respectively. IOP and PA measurements were made with the OBFA pneumatonometer. Axial length was measured using A-scan ultrasound, due to its known correlation with these corneal parameters. Stepwise multiple regression analysis was used to identify those components that contributed significant variance to the independent variables of IOP and PA. Results. The mean IOP and PA measurements were 13.1 (SD 3.3) mmHg and 3.0 (SD 1.2) mmHg respectively. IOP measurements made with the OBFA pneumatonometer correlated significantly with central corneal thickness (r = +0.374, p = 0.010), such that a 10 mm change in CCT was equivalent to a 0.30 mmHg change in measured IOP. PA measurements correlated significantly with axial length (part correlate = -0.651, p < 0.001) and mean corneal radius (part correlate = +0.459, p < 0.001) but not corneal thickness. Conclusions. IOP measurements taken with the OBFA pneumatonometer are correlated with corneal thickness, but not axial length or corneal curvature. Conversely, PA measurements are unaffected by corneal thickness, but correlated with axial length and corneal radius. These parameters should be taken into consideration when interpreting IOP and PA measurements made with the OBFA pneumatonometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High levels of corneal astigmatism are prevalent in a significant proportion of the population. During cataract surgery pre-existing astigmatism can be corrected using single or paired incisions on the steep axis of the cornea, using relaxing incisions or with the use of a toric intraocular lens. This review provides an overview of the conventional methods of astigmatic correction during cataract surgery and in particular, discusses the various types of toric lenses presently available and the techniques used in determining the correct axis for the placement of such lenses. Furthermore, the potential causes of rotation in toric lenses are identified, along with techniques for assessing and quantifying the amount of rotation and subsequent management options for addressing post-operative rotation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the relationship between ocular perfusion pressure and color Doppler measurements in patients with glaucoma. MATERIALS AND METHODS: Twenty patients with primary open-angle glaucoma with visual field deterioration in spite of an intraocular pressure lowered below 21 mm Hg, 20 age-matched patients with glaucoma with stable visual fields, and 20 age-matched healthy controls were recruited. After a 20-minute rest in a supine position, intraocular pressure and color Doppler measurements parameters of the ophthalmic artery and the central retinal artery were obtained. Correlations between mean ocular perfusion pressure and color Doppler measurements parameters were determined. RESULTS: Patients with glaucoma showed a higher intraocular pressure (P <.0008) and a lower mean ocular perfusion pressure (P <.0045) compared with healthy subjects. Patients with deteriorating glaucoma showed a lower mean blood pressure (P =.033) and a lower end diastolic velocity in the central retinal artery (P =.0093) compared with normals. Mean ocular perfusion pressure correlated positively with end diastolic velocity in the ophthalmic artery (R = 0.66, P =.002) and central retinal artery (R = 0.74, P <.0001) and negatively with resistivity index in the ophthalmic artery (R = -0.70, P =.001) and central retinal artery (R = -0.62, P =.003) in patients with deteriorating glaucoma. Such correlations did not occur in patients with glaucoma with stable visual fields or in normal subjects. The correlations were statistically significantly different between the study groups (parallelism of regression lines in an analysis of covariance model) for end diastolic velocity (P =.001) and resistivity index (P =.0001) in the ophthalmic artery, as well as for end diastolic velocity (P =.0009) and resistivity index (P =. 001) in the central retinal artery. CONCLUSIONS: The present findings suggest that alterations in ocular blood flow regulation may contribute to the progression in glaucomatous damage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Imaging of the crystalline lens and intraocular lens is becoming increasingly more important to optimize the refractive outcome of cataract surgery, to detect and manage complications and to ascertain advanced intraocular lens performance. This review examines recent advances in anterior segment imaging. RECENT FINDINGS: The main techniques used for imaging the anterior segment are slit-lamp biomicroscopy, ultrasound biomicroscopy, scheimpflug imaging, phakometry, optical coherence tomography and magnetic resonance imaging. They have principally been applied to the assessment of intraocular lens centration, tilt, position relative to the iris and movement with ciliary body contraction. SUMMARY: Despite the advances in anterior chamber imaging technology, there is still the need for a clinical, high-resolution, true anatomical, noninvasive technique to image behind the peripheral iris. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We assess the accuracy of the Visante anterior segment optical coherence tomographer (AS-OCT) and present improved formulas for measurement of surface curvature and axial separation. Measurements are made in physical model eyes. Accuracy is compared for measurements of corneal thickness (d1) and anterior chamber depth (d2) using-built-in AS-OCT software versus the improved scheme. The improved scheme enables measurements of lens thickness (d 3) and surface curvature, in the form of conic sections specified by vertex radii and conic constants. These parameters are converted to surface coordinates for error analysis. The built-in AS-OCT software typically overestimates (mean±standard deviation(SD)]d1 by +62±4 μm and d2 by +4±88μm. The improved scheme reduces d1 (-0.4±4 μm) and d2 (0±49 μm) errors while also reducing d3 errors from +218±90 (uncorrected) to +14±123 μm (corrected). Surface x coordinate errors gradually increase toward the periphery. Considering the central 6-mm zone of each surface, the x coordinate errors for anterior and posterior corneal surfaces reached +3±10 and 0±23 μm, respectively, with the improved scheme. Those of the anterior and posterior lens surfaces reached +2±22 and +11±71 μm, respectively. Our improved scheme reduced AS-OCT errors and could, therefore, enhance pre- and postoperative assessments of keratorefractive or cataract surgery, including measurement of accommodating intraocular lenses. © 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wardop first described retinoblastoma in 1809. It is the most common intraocular tumour of childhood and the most common tumour of the retina. It was originally thought to be a glioma arising from glial cells of the retina. However, in 1926 it was recognised as a tumour of undifferentiated photoreceptor cells. This article describes the basic clinical and pathological aspects of retinoblastoma, the advances in molecular genetics which have led to the discovery of the gene responsible, and the defects which have been discovered in the retinoblastoma gene.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need to measure the response of the oculomotor system, such as ocular accommodation, accurately and in real-world environments is essential. New instruments have been developed over the past 50 years to measure eye focus including the extensively utilised and well validated Canon R-1, but in general these have had limitations such as a closed field-of-view, a poor temporal resolution and the need for extensive instrumentation bulk preventing naturalistic performance of environmental tasks. The use of photoretinoscopy and more specifically the PowerRefractor was examined in this regard due to its remote nature, binocular measurement of accommodation, eye movement and pupil size and its open field-of-view. The accuracy of the PowerRefractor to measure refractive error was on averaging similar, but more variable than subjective refraction and previously validated instrumentation. The PowerRefractor was found to be tolerant to eye movements away from the visual axis, but could not function with small pupil sizes in brighter illumination. The PowerRefractor underestimated the lead of accommodation and overestimated the slope of the accommodation stimulus response curve. The PowerRefractor and the SRW-5000 were used to measure the oculomotor responses in a variety of real-world environment: spectacles compared to single vision contract lenses; the use of multifocal contact lenses by pre-presbyopes (relevant to studies on myopia retardation); and ‘accommodating’ intraocular lenses. Due to the accuracy concerns with the PowerRefractor, a purpose-built photoretinoscope was designed to measure the oculomotor response to a monocular head-mounted display. In conclusion, this thesis has shown the ability of photoretinoscopy to quantify changes in the oculomotor system. However there are some major limitations to the PowerRefractor, such as the need for individual calibration for accurate measures of accommodation and vergence, and the relatively large pupil size necessary for measurement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There were three principle aims to this thesis. Firstly, the acquisition protocols of clinical blood flow apparatus were investigated in order to optimise them for both cross-sectional and longitudinal application. Secondly, the effects of physiological factors including age and systematic circulation on ocular blood flow were investigated. Finally, the ocular perfusion characteristics of patients diagnosed with ocular diseases considered to be of a vascular origin were investigated. The principle findings of this work are:- 1) Optimisation of clinical investigationsPhotodiode sensitivity of the scanning laser Doppler flowmeter should be kept within a range of 70-150 DC when acquiring images of the retina and optic nerve head in order to optimise the reproducibility of capillary blood flow measures. Account of the physiological spatial variation in retinal blood flow measures can be made using standard analysis protocols of the scanning laser Doppler flowmeter combined with a local search strategy. Measurements of pulsatile ocular blood flow using the ocular blood flow analyser are reproducible, however this reproducibility can be improved when consecutive intraocular pressure pulses are used to calculate pulsatile ocular blood flow. Spectral analysis of the intraocular pressure pulse-wave is viable and identifies the first four harmonic components of the waveform. 2) Physiological variation in ocular perfusionAge results in a significant reduction in perfusion of the retinal microcirculation, which is not evident in larger vessel beds such as the choroid. Despite known asymmetry in the systemic vasculature, no evidence of interocular asymmetry in ocular perfusion is apparent. 3) Pathological variation in ocular perfusionIn primary open angle glaucoma, perfusion is reduced in the retinal microcirculation of patients classified as having early to moderate visual field defects. However, ocular pulsatility defects are masked when patients and subjects are matched for systemic variables (pulse rate and mean arterial pressure); differentiation is facilitated by the application of waveform analysis to the continuos intraocular pressure curve even in the early stages of disease. Diabetic patients with adequate glycaemic control, exhibit maintenance of macular blood flow, macular topography and visual function following phacoemulsification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study utilized the advanced technology provided by automated perimeters to investigate the hypothesis that patients with retinitis pigmentosa behave atypically over the dynamic range and to concurrently determine the influence of extraneous factors on the format of the normal perimetric sensitivity profile. The perimetric processing of some patients with retinitis pigmentosa was considered to be abnormal in either the temporal and/or the spatial domain. The standard size III stimulus saturated the central regions and was thus ineffective in detecting early depressions in sensitivity in these areas. When stimulus size was scaled in inverse proportion to the square root of ganglion cell receptive field density (M-scaled), isosensitive profiles did not result, although cortical representation was theoretically equivalent across the visual field. It was conjectured that this was due to variations in the ganglion cell characteristics with increasing peripheral angle, most notably spatial summation. It was concluded that the development of perimetric routines incorporating stimulus sizes adjusted in proportion to the coverage factor of retinal ganglion cells would enhance the diagnostic capacity of perimetry. Good general and local correspondence was found between perimetric sensitivity and the available retinal cell counts. Intraocular light scatter arising both from simulations and media opacities depressed perimetric sensitivity. Attenuation was greater centrally for the smaller LED stimuli, whereas the reverse was true for the larger projected stimuli. Prior perimetric experience and pupil size also demonstrated eccentricity-dependent effect on sensitivity. Practice improved perimetric sensitivity for projected stimuli at eccentricities greater than or equal to 30o; particularly in the superior region. Increase in pupil size for LED stimuli enhanced sensitivity at eccentricities greater than 10o. Conversely, microfluctuation in the accommodative response during perimetric examination and the correction of peripheral refractive error had no significant influence on perimetric sensitivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automated perimetry has made viable a rapid threshold examination of the visual field and has reinforced the role of perimetry in the diagnostic procedure. The aim of this study was twofold: to isolate the influence of certain extraneous factors on the sensitivity gradient, since these might limit the early detection and accurate monitoring of visual field loss and to investigate the efficacy of certain novel combinations of stimulus parameters in the detection of early visual field loss. The work was carried out with particular reference to glaucoma and to ocular hypertension. The effects of media opacities on the visual field were assessed by forward intraocular light scatter (n= 15) and were found to mask diffuse glaucomatous visual field loss and underestimate focal loss. Correction of the visual field indices for the effects of forward intraocular light scatter (n= 26) showed the focal losses to be, in reality, unaffected. Measurements of back scatter underestimated forward intraocular light scatter (n= 60) and the resultant depression of the visual field. Perimetric sensitivity improved with patient learning (n= 25) and exhibited eccentricity- and depth-dependency effects whereby improvements in sensitivity were greatest for peripheral areas of the field and for those areas which initially demonstrated the lowest sensitivity. The effects of practice were retained over several months (n= 16). Perimetric sensitivity decreased during prolonged examination due to fatigue effects (n&61 19); these demonstrated a similar eccentricity-dependency, being greatest for eccentricities beyond 30o. Mean sensitivities over the range of adaptation levels employed obeyed the Weber-Fechner law (n= 10) and, as would be expected, were independent of pupil size. No relationship was found between short-term fluctuation and adaptation level. Detection of diffuse glaucomatous visual field loss was facilitated using a size III stimulus of duration 200msec at an adaptation level of 31.5asb, compared with a size III stimulus of duration 100msec at an adaptation level of 4asb (n= 20). In a pilot study (n= 10), temporal summation was found to be higher in glaucomatous patients compared with age-matched controls, although the difference was not statistically significant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The object of the study was to investigate, establish and quantify the relationship between contrast sensitivity, intraocular light scatter and glare. The aim was to establish the effects on vision, in an effort to provide a more comprehensive understanding of the visual world of subjects prone to increased light scatter in the eye. Disability glare refers to the reduction in visual performance produced by a glare source. The reduction in visual performance can be explained by intraocular scattered light producing a veiling luminance which is superimposed upon the retinal image. This veiling luminance lowers contrast thus sensitivity to the stimulus declines. The effect of glare of luminance and colour contrast sensitivity for young and elderly subjects was examined. For both age groups, disability glare was greatest for the red-green stimulus and least for the blue-yellow. The precise effect of a glare source on colour discrimination depends upon the interaction between the chromaticity of the glare source and that of the stimulus. The effect of a long wavelength pass (red) and a short wavelength pass filter (blue) on disability glare was examined. Disability glare was not significantly different with the red and blue filters, even in the presence of wavelength dependent scatter. An equation was derived which allowed an intrinsic Light Scatter Factor (LSF) to be determined for any given glare angle (Paulsson and Sjöstrand, 1980). Corrections to the formula to account for factors such as pupil size changes are unnecessary. The results confirm the suitability of measuring the LSF using contrast threshold with and without glare, provided that appropriate methods are used. Using this formula an investigation into the amount of wavelength dependent scatter indicated that wavelength dependent scatter in normal young, elderly or cataractous eyes is of little or no significance. Finally, it seemed desirable to investigate the effect ultraviolet (UV) radiation has on intraocular light scatter and subsequently visual performance. Overall the results indicated that the presence or absence of UV radiation has relatively little effect on visual function for the young, elderly or cataract patient.