921 resultados para AUTOMATED PERIMETRY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50μgcm(-2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ammonium nitrate fuel oil (ANFO) is an explosive used in many civil applications. In Brazil, ANFO has unfortunately also been used in criminal attacks, mainly in automated teller machine (ATM) explosions. In this paper, we describe a detailed characterization of the ANFO composition and its two main constituents (diesel and a nitrate explosive) using high resolution and accuracy mass spectrometry performed on an FT-ICR-mass spectrometer with electrospray ionization (ESI(±)-FTMS) in both the positive and negative ion modes. Via ESI(-)-MS, an ion marker for ANFO was characterized. Using a direct and simple ambient desorption/ionization technique, i.e., easy ambient sonic-spray ionization mass spectrometry (EASI-MS), in a simpler, lower accuracy but robust single quadrupole mass spectrometer, the ANFO ion marker was directly detected from the surface of banknotes collected from ATM explosion theft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To study the effects of pupillary constriction on frequency doubling perimetry in a group of normal subjects. Methods: Eighteen healthy volunteers participated in the study. Only one eye per patient (right eye) underwent frequency doubling perimetry (Full Threshold C-20 strategy). For the second session, one drop of 2% pilocarpine was administered to the volunteers' right eye and the examination was repeated after 60 minutes. Results: Sixty minutes after administration of 2% pilocarpine, there was a significant reduction of the pupillary diameter from 4.22 ± 0.17 mm to 1.55 ± 0.51 mm (p<0.05). There was a significant reduction of the mean retinal sensibility after pupillary constriction. The threshold sensitivity of the central 5º worsened by 5.67 ± 2.49 dB; the area between 2.5º and 10º worsened by 4.49 ± 2.73 dB; and the area between 10º and 20º worsened by 5.10 ± 3.55 dB (p<0.01). A reduction of 4.06 ± 2.67 dB was observed in the mean deviation, as well as an increase of 0.64 ± 0.94 dB in the pattern standard deviation (p<0.01). No differences were observed regarding the number of fixation losses, false-positive and false-negatives responses, and duration of the examination. Conclusion: Changes in pupillary diameter may produce significant declines in threshold sensitivities of the 20º visual field tested by frequency doubling perimetry. These results suggest that is important to maintain a constant pupillary diameter in seriate examinations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the learning effect, short-term fluctuation and long-term fluctuation in healthy subjects undergoing frequency doubling perimetry (FDP). METHODS: Twenty healthy young subjects underwent FDT (program N30, full threshold) in one eye (right). Each subject was tested once in the first three sessions and three times in the fourth session. Both short- and long-term fluctuations were studied as the average fluctuation of all the tested points or as a point-to-point fluctuation. To study the learning effect, the MDs values of the first session were compared to the second, third and fourth sessions. RESULTS: In the short-term analysis (3 examination done in the last session), the total mean sensitivity was 31.91 ± 1.20 dB and the mean MD and PSD were 0.84 ± 1.85 and 3.73 ± 1.55 dB, respectively. The average short-term fluctuation was 1.72 ± 0.38 dB. When the four examination, performed at different visits, were compared, the average mean sensitivity of all sessions and the average long-term fluctuation were 31.75 ± 1.11 and 2.16 ± 0.26 dB, respectively. The MD averages of the first, second, third and fourth tests were 0.11 ± 2.14 dB, 0.47 ± 1.64 dB, 1.16 ± 1.62 dB and 0.98 ± 1.92 dB respectively. The MD difference between the first and the third and between the first and the fourth examinations were statistically significant (p<0.05). CONCLUSION: The threshold sensitivity detected by FDP is influenced by both short- and long-term fluctuations. We observed a mild learning effect that shoud be taken into account whenever a patient undergoes this test for the first time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aims of this study were to carry out a serological survey of canine leishmaniasis and identify the phlebotomine fauna in the urban area of Bonito, Mato Grosso do Sul. The serological survey was conducted on a sample of 303 dogs, by means of the indirect immunofluorescence test. Phlebotomines were captured using automated light traps. The serological survey found that 30% of the dogs were seropositive, both from the center and from all districts of the town. A total of 2,772 specimens of phlebotomines were caught and the species most found was Lutzomyia longipalpis (90.4%), which corroborated its role as the vector of for canine visceral leishmaniasis in the region. Phlebotomines of the species Bichromomyia flaviscutellata (the main vector for Leishmania (Leishmania) amazonensis) and Nyssomyia whitmani (the vector for Leishmania (Viannia) brasiliensis) were also caught. The findings indicate the need for continuous epidemiological surveillance, with attention towards diminishing the vector breeding sites and the transmission of these diseases in that region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo. Estudar a mortalidade relacionada à paracoccidioidomicose informada em qualquer linha ou parte do atestado médico da declaração de óbito. Métodos. Os dados provieram dos bancos de causas múltiplas de morte da Fundação Sistema Estadual de Análise de Dados (SEADE) de São Paulo entre 1985 e 2005. Foram calculados os coeficientes padronizados de mortalidade relacionada à paracoccidioidomicose como causa básica, como causa associada e pelo total de suas menções. Resultados. No período de 21 anos ocorreram 1 950 óbitos, sendo a paracoccidioidomicose a causa básica de morte em 1 164 (59,7%) e uma causa associada de morte em 786 (40,3%). Entre 1985 e 2005 observou-se um declínio do coeficiente de mortalidade pela causa básica de 59,8% e pela causa associada, de 53,0%. O maior número de óbitos ocorreu entre os homens, nas idades mais avançadas, entre lavradores, com tendência de aumento nos meses de inverno. As principais causas associadas da paracoccidioidomicose como causa básica foram a fibrose pulmonar, as doenças crônicas das vias aéreas inferiores e as pneumonias. As neoplasias malignas e a AIDS foram as principais causas básicas estando a paracoccidioidomicose como causa associada. Verificou-se a necessidade de adequar as tabelas de decisão para o processamento automático de causas de morte nos atestados de óbito com a menção de paracoccidioidomicose. Conclusões. A metodologia das causas múltiplas de morte, conjugada com a metodologia tradicional da causa básica, abre novas perspectivas para a pesquisa que visa a ampliar o conhecimento sobre a história natural da paracoccidioidomicose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a considerable debate about the potential influence of fetal programming on cardiovascular diseases in adulthood. In the present prospective epidemiological cohort study, the relationship between birthweight and arterial elasticity in 472 children between 5 and 8 years of age was assessed. LAEI (large artery elasticity index), SAEI (small artery elasticity index) and BP (blood pressure) were assessed using the HDI/PulseWave CR-2000 CardioVascular Profiling System. Blood concentrations of glucose, total cholesterol and its fractions [LDL (low-density lipoprotein)-cholesterol and HDL (high-density lipoprotein)-cholesterol] and triacylglycerols (triglycerides) were determined by automated enzymatic methods. Insulin was assessed by a chemiluminescent method, insulin resistance by HOMA (homoeostasis model assessment) and CRP (C-reactive protein) by immunonephelometry. Two linear regression models were applied to investigate the relationship between the outcomes, LAEI and SAEI, and the following variables: birthweight, gestational age, glucose, LDL-cholesterol, HDL-cholesterol, triacylglycerols, insulin, CRP, HOMA, age, gender, waist circumference, per capita income, SBP (systolic BP) and DBP (diastolic BP). LAEI was positively associated with birthweight (P=0.036), waist circumference (P<0.001) and age (P<0.001), and negatively associated with CRP (P=0.024) and SBP (P<0.001). SAEI was positively associated with birthweight (P=0.04), waist circumference (P=0.001) and age (P<0.001), and negatively associated with DBP (P<0.001). Arterial elasticity was decreased in apparently healthy children who had lower birthweights, indicating an earlier atherogenetic susceptibility to cardiovascular diseases in adolescence and adult life. Possible explanations for the results include changes in angiogenesis during critical phases of intrauterine life caused by periods of fetal growth inhibition and local haemodynamic anomalies

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background & aims.This study examined the relationship between birthweight and blood pressure in childhood. Methods.Prospective cohort study involving 472 Brazilian children ranging in age from 5 to 8 years. Birthweight, systolic blood pressure (SBP), diastolic blood pressure (DBP), body mass index (BMI), total cholesterol and fractions (LDL-c, HDL-c), and triglycerides were determined. Total cholesterol, LDL-c, HDL-c, and triglycerides were assessed by automated enzymatic methods. Blood pressure was measured with the HDI/Pulse Wave™ CR-2000 equipment. Multiple regression models were used to investigate the relationship between birthweight and SBP and DBP, controlling for the following variables: gender, age, BMI, total cholesterol, triglycerides, per capita income, and maternal education. Results.When adjusting for gender and BMI, we found a systolic blood pressure increase of 2.9 (95per cent CI = −5.33 to −0.56) mmHg per kilogram birthweight reduction. The unadjusted association was insignificant. Conclusion.Our data suggest that low birthweight is one of the factors contributing to blood pressure elevation at early ages. A way to prevent these diseases is by implementing public policies focused on good nutrition and adequate prenatal care for pregnant women

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic diseases that are typical of adulthood may originate in intra-uterine life through inadequate fetal development. The present epidemiological cohort study of 506 healthy children aged 5\20138 years evaluated the relationship between birth weight and insulin resistance in an age group that has been assessed in few similar studies. Insulin concentration was determined by chemiluminescence and insulin resistance by the homeostasis model assessment (HOMA). Blood glucose, total cholesterol and fractions (LDL cholesterol and HDL cholesterol) and TAG concentrations were determined by automated enzymatic methods. Linear regression analysis investigated the relationship between birth weight (assessed as a continuous variable and in three categories: small for gestational age, SGA; adequate for gestational age and large for gestational age) and the HOMA index, using backward stepwise selection and biological models to explain the causal pathway of the relationship. There were negativeassociations between birth weight (P < 0·001), SGA (P = 0·027) and the HOMA index, and a positive association between waist circumference (P < 0·001) and the HOMA index. Considering the significant associations between birth weight and waist circumference (P < 0·001) and waist circumference and insulin resistance (P < 0·001), we can probably suspect that lower birth weight is a common cause of higher waist circumference and insulin resistance. In summary, the results of the present study showed increased insulin resistance in apparently healthy, young children, who had lower weight at birth and higher measurements of waist circumference. There is a need to develop public health policies that adopt preventive measures to promote adequate maternal-fetal and child development and enable early diagnosis of metabolic abnormalities

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4', 4 ''-methylidynetris (N, N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO(-) in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 mu g of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L(-1) ClO(-), a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L(-1) ClO(-), a detection limit of 6.0 mu g L(-1) ClO(-), a sampling throughput of 84 determinations per hour, and a waste generation of 432 mu L per determination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new flow procedure based on multicommutation with chemiluminometric detection was developed to quantify gentamicin sulphate in pharmaceutical formulations. This approach is based on gentamicin's ability to inhibit the chemiluminometric reaction between luminol and hypochlorite in alkaline medium, causing a decrease in the analytical signal. The inhibition of the analytical signal is proportional to the concentration of gentamicin sulphate, within a linear range of 1 to 4 mu g mL(-1) with a coefficient variation <3%. A sample throughput of 55 samples h(-1) was obtained. The developed method is sensitive, simple, with low reagent consumption, reproducible, and inexpensive, and when applied to the analysis of pharmaceutical formulations (eye drops and injections) it gave results with RSD between 1.10 and 4.40%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims. We derive lists of proper-motions and kinematic membership probabilities for 49 open clusters and possible open clusters in the zone of the Bordeaux PM2000 proper motion catalogue (+ 11 degrees <= delta <= + 18 degrees). We test different parametrisations of the proper motion and position distribution functions and select the most successful one. In the light of those results, we analyse some objects individually. Methods. We differenciate between cluster and field member stars, and assign membership probabilities, by applying a new and fully automated method based on both parametrisations of the proper motion and position distribution functions, and genetic algorithm optimization heuristics associated with a derivative-based hill climbing algorithm for the likelihood optimization. Results. We present a catalogue comprising kinematic parameters and associated membership probability lists for 49 open clusters and possible open clusters in the Bordeaux PM2000 catalogue region. We note that this is the first determination of proper motions for five open clusters. We confirm the non-existence of two kinematic populations in the region of 15 previously suspected non-existent objects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hemoglobinopathies were included in the Brazilian Neonatal Screening Program on June 6, 2001. Automated high-performance liquid chromatography (HPLC) was indicated as one of the diagnostic methods. The amount of information generated by these systems is immense, and the behavior of groups cannot always be observed in individual analyses. Three-dimensional (3-D) visualization techniques can be applied to extract this information, for extracting patterns, trends or relations from the results stored in databases. We applied the 3-D visualization tool to analyze patterns in the results of hemoglobinopathy based on neonatal diagnosis by HPLC. The laboratory results of 2520 newborn analyses carried out in 2001 and 2002 were used. The ""Fast"", ""F1"", ""F"" and ""A"" peaks, which were detected by the analytical system, were chosen as attributes for mapping. To establish a behavior pattern, the results were classified into groups according to hemoglobin phenotype: normal (N = 2169), variant (N = 73) and thalassemia (N = 279). 3-D visualization was made with the FastMap DB tool; there were two distribution patterns in the normal group, due to variation in the amplitude of the values obtained by HPLC for the F1 window. It allowed separation of the samples with normal Hb from those with alpha thalassemia, based on a significant difference (P < 0.05) between the mean values of the ""Fast"" and ""A"" peaks, demonstrating the need for better evaluation of chromatograms; this method could be used to help diagnose alpha thalassemia in newborns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper was to study a method based on gas production technique to measure the biological effects of tannins on rumen fermentation. Six feeds were used as fermentation substrates in a semi-automated gas method: feed A - aroeira (Astronium urundeuva); feed B - jurema preta (Mimosa hostilis), feed C - sorghum grains (Sorghum bicolor); feed D - Tifton-85 (Cynodon sp.); and two others prepared mixing 450 g sorghum leaves, 450 g concentrate (maize and soybean meal) and 100 g either of acacia (Acacia mearnsii) tannin extract (feed E) or quebracho (Schinopsis lorentzii) tannin extract (feed F) per kg (w:w). Three assays were carried out to standardize the bioassay for tannins. The first assay compared two binding agents (polyethylene glycol - PEG - and polyvinyl polypirrolidone - PVPP) to attenuate the tannin effects. The complex formed by PEG and tannins showed to be more stable than PVPP and tannins. Then, in the second assay, PEG was used as binding agent, and this assay was done to evaluate levels of PEG (0, 500, 750, 1000 and 1250 mg/g DM) to minimize the tannin effect. All the tested levels of PEG produced a response to evaluate tannin effects but the best response was for dose of 1000 mg/g DM. Using this dose of PEG, the final assay was carried out to test three compounds (tannic acid, quebracho extract and acacia extract) to establish a curve of biological equivalent effect of tannins. For this, five levels of each compound were added to I g of a standard feed (Lucerne hay). The equivalent effect showed not to be directly related to the chemical analysis for tannins. It was shown that different sources of tannins had different activities or reactivities. The curves of biological equivalence can provide information about tannin reactivity and its use seems to be important as an additional factor for chemical analysis. (C) 2007 Elsevier B.V. All rights reserved.