989 resultados para 1.0-1.1 phi
Resumo:
The present work aimed to evaluate, through ten different studies, the therapeutic efficacy of a new pour-on formulation, containing 1.5 per cent ivermectin +0.5 per cent abamectin, against parasites of cattle. Results obtained on trials against Rhipicephalus (Boophilus) microplus showed that the pour-on combination of 1.5 per cent ivermectin +0.5 per cent abamectin obtained superior efficacy indexes against this ectoparasite, when compared with formulations containing 0.5 per cent ivermectin, 1 per cent ivermectin and the combination of 1 per cent abamectin +20 per cent levamisole. The results of efficacy of the ivermectin+abamectin and the 0.5 per cent ivermectin against Haematobia irritans were similar. Against Cochliomyia hominivorax larvae, all pour-on formulations tested (1.5 per cent ivermectin +0.5 per cent abamectin, 0.5 per cent ivermectin and 0.5 per cent abamectin), as well as 1 per cent doramectin administered subcutaneously, were considered ineffective. Cattle medicated with 1.5 per cent ivermectin +0.5 per cent abamectin, pour-on, remained free from parasitism by Dermatobia hominis larvae during 42 days (96 per cent efficacy), while values superior to 90 per cent were obtained by 0.5 per cent ivermectin (92 per cent) and 0.5 per cent abamectin (93 per cent) until the 42nd and 35th days post treatment, respectively. Against Haemonchus placei and Oesophagostomum radiatum, the pour-on of ivermectin+abamectin showed better efficacy than the 0.5 per cent ivermectin and 0.5 per cent abamectin. As to Cooperia punctata, there was no difference regarding efficacy results obtained by the avermectins combination and abamectin. The pour-on combination of 1.5 per cent ivermectin +0.5 per cent abamectin obtained high efficacy against R. (B.) microplus, D. hominis and some species of cattle gastrointestinal helminths when compared with formulations of 0.5 per cent ivermectin and 0.5 per cent abamectin administered through the same route.
Resumo:
Ceramic powders based on Zn3Ga2Ge2O10: Cr3+ X% (X = 0.0; 0.5; 0.75; 1.0) were synthesized by solid-state reaction method. The gallium-zinc germanate doped with chromium presents an interesting property of phosphorescence, that means, it is capable of emitting light when excited by a source of radiation, and such emission remains for some time after stopping the source. For this reason, these materials can be widely applied in night-vision surveillance, (through the use of solar energy, for example), electronic devices screen, emergency routes signals, control panels indicators in dark environments, etc. In this job were considered different amounts of dopant in order to perform a comparison of structural and photoluminescent properties. For that, some analyses were performed on samples, such as XRD, FT-Raman, SEM, UV-vis and photoluminescence measurements (PL). Such analysis allowed to infer that the presence of chromium results in no phase transformation, so that the four compositions have the same set of phases: cubic, rhombohedral and hexagonal. Although the structure was not changed, chromium influences other properties / characteristics of these materials. Examples are: increase of band-gap, decrease of average particle size, small changes in binding energy checked by Raman and especially the increase of photoluminescent property. The chromium ions have great ease in replacing gallium ions in octahedral sites, resulting in emission of light with a wavelength of about 700 nm (infrared region), which is justified by the spin-forbidden 2E 4A2 transition. In other words, chromium is a favorable luminescent center, acting as a trap in the crystal structure, since it imprisons the excitation energy easily and releases it gradually, allowing the phosphorescence. It was observed that the composition ... (Complete abastract click electronic access below)
Resumo:
Ceramic powders based on Zn3Ga2Ge2O10: Cr3+ X% (X = 0.0; 0.5; 0.75; 1.0) were synthesized by solid-state reaction method. The gallium-zinc germanate doped with chromium presents an interesting property of phosphorescence, that means, it is capable of emitting light when excited by a source of radiation, and such emission remains for some time after stopping the source. For this reason, these materials can be widely applied in night-vision surveillance, (through the use of solar energy, for example), electronic devices screen, emergency routes signals, control panels indicators in dark environments, etc. In this job were considered different amounts of dopant in order to perform a comparison of structural and photoluminescent properties. For that, some analyses were performed on samples, such as XRD, FT-Raman, SEM, UV-vis and photoluminescence measurements (PL). Such analysis allowed to infer that the presence of chromium results in no phase transformation, so that the four compositions have the same set of phases: cubic, rhombohedral and hexagonal. Although the structure was not changed, chromium influences other properties / characteristics of these materials. Examples are: increase of band-gap, decrease of average particle size, small changes in binding energy checked by Raman and especially the increase of photoluminescent property. The chromium ions have great ease in replacing gallium ions in octahedral sites, resulting in emission of light with a wavelength of about 700 nm (infrared region), which is justified by the spin-forbidden 2E 4A2 transition. In other words, chromium is a favorable luminescent center, acting as a trap in the crystal structure, since it imprisons the excitation energy easily and releases it gradually, allowing the phosphorescence. It was observed that the composition ... (Complete abastract click electronic access below)
Resumo:
With Hg-199 atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm for which the FWHM is similar to 15 Hz. Here we lock an ultrastable laser to this ultranarrow S-1(0) - P-3(0) clock transition and achieve a fractional frequency instability of 5.4 x 10(-15) / root tau for tau <= 400 s. The highly stable laser light used for the atom probing is derived from a 1062.6 nm fiber laser locked to an ultrastable optical cavity that exhibits a mean drift rate of -6.0 x 10(-17) s-(1) (-16.9 mHzs(-1) at 282 THz) over a six month period. A comparison between two such lasers locked to independent optical cavities shows a flicker noise limited fractional frequency instability of 4 x 10(-16) per cavity. (c) 2012 Optical Society of America
Resumo:
Experimental flow boiling heat transfer results are presented for horizontal 1.0 and 2.2 mm I. D. (internal diameter) stainless steel tubes for tests with R1234ze(E), a new refrigerant developed as a substitute for R134a with a much lower global warming potential (GWP). The experiments were performed for these two tube diameters in order to investigate a possible transition between macro and microscale flow boiling behavior. The experimental campaign includes mass velocities ranging from 50 to 1500 kg/m(2) s, heat fluxes from 10 to 300 kW/m(2), exit saturation temperatures of 25, 31 and 35 degrees C, vapor qualities from 0.05 to 0.99 and heated lengths of 180 mm and 361 mm. Flow pattern characterization was performed using high speed videos. Heat transfer coefficient, critical heat flux and flow pattern data were obtained. R1234ze(E) demonstrated similar thermal performance to R134a data when running at similar conditions. [DOI: 10.1115/1.4004933]
Resumo:
We estimate the masses of the 1(--) heavy four-quark and molecule states by combining exponential Laplace (LSR) and finite energy (FESR) sum rules known perturbatively to lowest order (LO) in alpha(s) but including non-perturbative terms up to the complete dimension-six condensate contributions. This approach allows to fix more precisely the value of the QCD continuum threshold (often taken ad hoc) at which the optimal result is extracted. We use double ratio of sum rules (DRSR) for determining the SU(3) breakings terms. We also study the effects of the heavy quark mass definitions on these LO results. The SU(3) mass-splittings of about (50-110) MeV and the ones of about (250-300) MeV between the lowest ground states and their 1st radial excitations are (almost) heavy-flavor independent. The mass predictions summarized in Table 4 are compared with the ones in the literature (when available) and with the three Y-c(4260, 4360, 4660) and Y-b(10890) 1(--) experimental candidates. We conclude (to this order approximation) that the lowest observed state cannot be a pure 1(--) four-quark nor a pure molecule but may result from their mixings. We extend the above analyzes to the 0(++) four-quark and molecule states which are about (0.5-1) GeV heavier than the corresponding 1(--) states, while the splittings between the 0(++) lowest ground state and the 1st radial excitation is about (300-500) MeV. We complete the analysis by estimating the decay constants of the 1(--) and 0(++) four-quark states which are tiny and which exhibit a 1/M-Q behavior. Our predictions can be further tested using some alternative non-perturbative approaches or/and at LHCb and some other hadron factories. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
Der radiative Zerfall eines Hyperons in ein leichteres Hyperon und ein Photon erlaubt eine Untersuchung der Struktur der elektroschwachen Wechselwirkung von Hadronen. Dazu wird die Zerfallsasymmetrie $alpha$ betrachtet. Sie beschreibt die Verteilung des Tochterhyperons bezüglich der Polarisation $vec{P}$ des Mutterhyperons mit $dN / d cos(Theta) propto 1 + alpha |vec{P}| cos(Theta)$, wobei $Theta$ der Winkel zwischen $vec{P}$ und dem Impuls des Tochterhyperons ist. Von besonderem Interesse ist der radiative Zerfall $Xi^0 to Lambda gamma$, für den alle Rechnungen auf Quarkniveau eine positive Asymmetrie vorhersagen, wohingegen bisher eine negative Asymmetrie von $alpha_{Lambda gamma} = -0,73 +- 0,17$ gemessen wurde. Ziel dieser Arbeit war es, die bisherigen Messungen zu überprüfen und die Asymmetrie mit einer deutlich höheren Präzision zu bestimmen. Ferner wurden die Zerfallsasymmetrie des radiativen Zerfalls $Xi^0 to Sigma^0 gamma$ ermittelt und zum Test der angewandten Analysemethode der gut bekannte Zerfall $Xi^0 to Lambda pi^0$ herangezogen. Während der Datennahme im Jahr 2002 zeichnete das NA48/1-Experiment am CERN gezielt seltene $K_S$- und Hyperonzerfälle auf. Damit konnte der weltweit größte Datensatz an $Xi^0$-Zerfällen gewonnen werden, aus dem etwa 52.000 $Xi^0 to Lambda gamma$-Zerfälle, 15.000 $Xi^0 to Sigma^0 gamma$-Zerfälle und 4 Mill. $Xi^0 to Lambda pi^0$-Zerfälle mit nur geringem Untergrund extrahiert wurden. Ebenso wurden die entsprechenden $antiXi$-Zerfälle mit etwa einem Zehntel der obigen Ereigniszahlen registriert. Die Bestimmung der Zerfallsasymmetrien erfolgte durch den Vergleich der gemessene Daten mit einer detaillierten Detektorsimulation und führte zu den folgenden Resultaten dieser Arbeit: $alpha_{Lambda gamma} = -0,701 +- 0,019_{stat} +- 0,064_{sys}$, $alpha_{Sigma^0 gamma} = -0,683 +- 0,032_{stat} +- 0,077_{sys}$, $alpha_{Lambda pi^0} = -0,439 +- 0,002_{stat} +- 0,056_{sys}$, $alpha_{antiLambda gamma} = 0,772 +- 0,064_{stat} +- 0,066_{sys}$, $alpha_{antiSigma^0 gamma} = 0,811 +- 0,103_{stat} +- 0,135_{sys}$, $alpha_{antiLambda pi^0} = 0,451 +- 0,005_{stat} +- 0,057_{sys}$. Somit konnte die Unsicherheit der $Xi^0 to Lambda gamma$-Zerfallsasymmetrie auf etwa ein Drittel reduziert werden. Ihr negatives Vorzeichen und damit der Widerspruch zu den Vorhersagen der Quarkmodellrechnungen ist so zweifelsfrei bestätigt. Mit den zum ersten Mal gemessenen $antiXi$-Asymmetrien konnten zusätzlich Grenzen auf eine mögliche CP-Verletzung in den $Xi^0$-Zerfällen, die $alpha_{Xi^0} neq -alpha_{antiXi}$ zur Folge hätte, bestimmt werden.
Resumo:
The electromagnetic form factors of the proton are fundamental quantities sensitive to the distribution of charge and magnetization inside the proton. Precise knowledge of the form factors, in particular of the charge and magnetization radii provide strong tests for theory in the non-perturbative regime of QCD. However, the existing data at Q^2 below 1 (GeV/c)^2 are not precise enough for a hard test of theoretical predictions.rnrnFor a more precise determination of the form factors, within this work more than 1400 cross sections of the reaction H(e,e′)p were measured at the Mainz Microtron MAMI using the 3-spectrometer-facility of the A1-collaboration. The data were taken in three periods in the years 2006 and 2007 using beam energies of 180, 315, 450, 585, 720 and 855 MeV. They cover the Q^2 region from 0.004 to 1 (GeV/c)^2 with counting rate uncertainties below 0.2% for most of the data points. The relative luminosity of the measurements was determined using one of the spectrometers as a luminosity monitor. The overlapping acceptances of the measurements maximize the internal redundancy of the data and allow, together with several additions to the standard experimental setup, for tight control of systematic uncertainties.rnTo account for the radiative processes, an event generator was developed and implemented in the simulation package of the analysis software which works without peaking approximation by explicitly calculating the Bethe-Heitler and Born Feynman diagrams for each event.rnTo separate the form factors and to determine the radii, the data were analyzed by fitting a wide selection of form factor models directly to the measured cross sections. These fits also determined the absolute normalization of the different data subsets. The validity of this method was tested with extensive simulations. The results were compared to an extraction via the standard Rosenbluth technique.rnrnThe dip structure in G_E that was seen in the analysis of the previous world data shows up in a modified form. When compared to the standard-dipole form factor as a smooth curve, the extracted G_E exhibits a strong change of the slope around 0.1 (GeV/c)^2, and in the magnetic form factor a dip around 0.2 (GeV/c)^2 is found. This may be taken as indications for a pion cloud. For higher Q^2, the fits yield larger values for G_M than previous measurements, in agreement with form factor ratios from recent precise polarized measurements in the Q2 region up to 0.6 (GeV/c)^2.rnrnThe charge and magnetic rms radii are determined as rn⟨r_e⟩=0.879 ± 0.005(stat.) ± 0.004(syst.) ± 0.002(model) ± 0.004(group) fm,rn⟨r_m⟩=0.777 ± 0.013(stat.) ± 0.009(syst.) ± 0.005(model) ± 0.002(group) fm.rnThis charge radius is significantly larger than theoretical predictions and than the radius of the standard dipole. However, it is in agreement with earlier results measured at the Mainz linear accelerator and with determinations from Hydrogen Lamb shift measurements. The extracted magnetic radius is smaller than previous determinations and than the standard-dipole value.
Resumo:
To study the changes in blood volume and hormones controlling sodium and water homeostasis after infusions of 0.9% saline, Gelofusine (4% succinylated gelatin in 0.7% saline, weight-average molecular weight 30 kD), and Voluven (6% hydroxyethyl starch in 0.9% saline, weight-average molecular weight 130 kD) in healthy volunteers.
Resumo:
BACKGROUND: Chlorhexidine (CHX) rinsing after periodontal surgery is common. We assessed the clinical and microbiological effects of two CHX concentrations following periodontal surgery. MATERIALS AND METHODS: In a randomized, controlled clinical trial, 45 subjects were assigned to 4 weeks rinsing with a 0.05 CHX/herbal extract combination (test) or a 0.1% CHX solution. Clinical and staining effects were studied. Subgingival bacteria were assessed using the DNA-DNA checkerboard. Statistics included parametric and non-parametric tests (p<0001 to declare significance at 80% power). RESULTS: At weeks 4 and 12, more staining was found in the control group (p<0.05 and p<0.001, respectively). A higher risk for staining was found in the control group (crude OR: 2.3:1, 95% CI: 1.3 to 4.4, p<0.01). The absolute staining reduction in the test group was 21.1% (9 5% CI: 9.4-32.8%). Probing pocket depth (PPD) decreases were significant (p<0.001) in both groups and similar (p=0.92). No rinse group differences in changes of bacterial counts for any species were found between baseline and week 12. CONCLUSIONS: The test CHX rinse resulted in less tooth staining. At the study endpoint, similar and high counts of periodontal pathogens were found.
Resumo:
The use of water suppression for in vivo proton MR spectroscopy diminishes the signal intensities from resonances that undergo magnetization exchange with water, particularly those downfield of water. To investigate these exchangeable resonances, an inversion transfer experiment was performed using the metabolite cycling technique for non-water-suppressed MR spectroscopy from a large brain voxel in 11 healthy volunteers at 3.0 T. The exchange rates of the most prominent peaks downfield of water were found to range from 0.5 to 8.9 s(-1), while the T(1) relaxation times in absence of exchange were found to range from 175 to 525 ms. These findings may help toward the assignments of the downfield resonances and a better understanding of the sources of contrast in chemical exchange saturation transfer imaging.