918 resultados para thermogravimetry and differential thermal analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fire safety of light gauge cold-formed steel frame (LSF) wall systems is significant to the build-ing design. Gypsum plasterboard is widely used as a fire safety material in the building industry. It contains gypsum (CaSO4.2H2O), Calcium Carbonate (CaCO3) and most importantly free and chemically bound water in its crystal structure. The dehydration of the gypsum and the decomposition of Calcium Carbonate absorb heat, which gives the gypsum plasterboard fire resistant qualities. Recently a new composite panel system was developed, where a thin insulation layer was used externally between two plasterboards to improve the fire performance of LSF walls. In this research, finite element thermal models of both the traditional LSF wall panels with cavity insulation and the new LSF composite wall panels were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties of gypsum plaster-board, insulation materials and steel were used. The developed models were then validated by comparing their results with fire test results. This paper presents the details of the developed finite element models of non-load bearing LSF wall panels and the thermal analysis results. It has shown that finite element models can be used to simulate the thermal behaviour of LSF walls with varying configurations of insulations and plasterboards. The results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection. Effects of real fire conditions are also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Normal thoracic kyphosis Cobb angle for T5-T12 is most commonly reported as a range of 20-40º [1]. Patients with adolescent idiopathic scoliosis (AIS) exhibit a reduced thoracic kyphosis or hypokyphosis [2] accompanying the coronal and rotary distortion components. As a result, surgical restoration of the thoracic kyphosis while maintaining lumbar lordosis and overall sagittal balance is a critical aspect of achieving good clinical outcomes in AIS patients. Previous studies report an increase in thoracic kyphosis after anterior surgical approaches [3] and a flattening of sagittal contours following posterior approaches [4]. Difficulties with measuring sagittal parameters on radiographs are avoided with reformatted sagittal CT reconstructions due to the superior endplate clarity afforded by this imaging modality and are the subject of analysis in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Clarence-Moreton Basin (CMB) covers approximately 26000 km2 and is the only sub-basin of the Great Artesian Basin (GAB) in which there is flow to both the south-west and the east, although flow to the south-west is predominant. In many parts of the basin, including catchments of the Bremer, Logan and upper Condamine Rivers in southeast Queensland, the Walloon Coal Measures are under exploration for Coal Seam Gas (CSG). In order to assess spatial variations in groundwater flow and hydrochemistry at a basin-wide scale, a 3D hydrogeological model of the Queensland section of the CMB has been developed using GoCAD modelling software. Prior to any large-scale CSG extraction, it is essential to understand the existing hydrochemical character of the different aquifers and to establish any potential linkage. To effectively use the large amount of water chemistry data existing for assessment of hydrochemical evolution within the different lithostratigraphic units, multivariate statistical techniques were employed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study of the bulk formation of YBa2Cu3O7-x from the Y2BaCuO5 plus liquid regime reveals that phase formation occurs at appreciable rates below 950°C in air. This result has been observed for phase-pure YBa2Cu3O7-x starting material given two types of heat treatment: held at 1100°C and slow-cooled from 1030°C at 6°C/h or heat-treated isothermally. Differential thermal analysis, with a cooling rate of 10°C/min indicates that the degree of undercooling for the peritectic formation of YBa2Cu3O7-x is greater than 100°C. © 1994.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the increasingly competitive Australian tertiary education market, a consumer orientation is essential. This is particularly so for small regional campuses competing with larger universities in the state capitals. Campus management need to carefully monitor both the perceptions of prospective students within the catchment area, and the (dis)satisfaction levels of current students. This study reports the results of an exploratory investigation into the perceptions held of a regional campus, using two techniques that have arguably been underutilised in the education marketing literature. Repertory Grid Analysis, a technique developed almost fifty years ago, was used to identify attributes deemed salient to year 12 high school students at the time they were applying for university places. Importance-performance analysis (IPA), developed three decades ago, was then used to identify attributes that were determinant for a new cohort of first year undergraduate students. The paper concludes that group applications of Repertory Grid offer education market researchers a useful means for identifying attributes used by high school students to differentiate universities, and that IPA is a useful technique for guiding promotional decision making. In this case, the two techniques provided a quick, economical and effective snapshot of market perceptions, which can be used as a foundation for the development of an ongoing market research programme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This investigation has shown that by transforming free caustic in red mud (RM) to Bayer hydrotalcite (during the seawater neutralization (SWN) process) enables a more controlled release mechanism for the neutralization of acid sulfate soils. The formation of hydrotalcite has been confirmed by X-ray diffraction (XRD) and differential thermalgravimetric analysis (DTG), while the dissolution of hydrotalcite and sodalite has been observed through XRD, DTG, pH plots, and ICP-OES. Coupling of all techniques enabled three neutralization mechanisms to be determined: (1) free alkali, (2) hydrotalcite dissolution, and (3) sodalite dissolution. The mechanisms are determined on the basis of ICP-OES and kinetic information. When the mass of RM or SWN-RM is greater than 0.08 g/50 mL, the pH of solution increases to a suitable value for plant life with aluminum leaching kept at a minimum. To obtain a neutralization pH greater than 6 in 10 min, the following ratio of bauxite residue (g) in 50 mL with a known iron sulfate (Fe2(SO4)3) concentration can be determined as follows: 0.04 g:50 mL:0.1 g/L of Fe2(SO4)3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Small-angle and ultra-small-angle neutron scattering (SANS and USANS) measurements were performed on samples from the Triassic Montney tight gas reservoir in Western Canada in order to determine the applicability of these techniques for characterizing the full pore size spectrum and to gain insight into the nature of the pore structure and its control on permeability. The subject tight gas reservoir consists of a finely laminated siltstone sequence; extensive cementation and moderate clay content are the primary causes of low permeability. SANS/USANS experiments run at ambient pressure and temperature conditions on lithologically-diverse sub-samples of three core plugs demonstrated that a broad pore size distribution could be interpreted from the data. Two interpretation methods were used to evaluate total porosity, pore size distribution and surface area and the results were compared to independent estimates derived from helium porosimetry (connected porosity) and low-pressure N2 and CO2 adsorption (accessible surface area and pore size distribution). The pore structure of the three samples as interpreted from SANS/USANS is fairly uniform, with small differences in the small-pore range (<2000 Å), possibly related to differences in degree of cementation, and mineralogy, in particular clay content. Total porosity interpreted from USANS/SANS is similar to (but systematically higher than) helium porosities measured on the whole core plug. Both methods were used to estimate the percentage of open porosity expressed here as a ratio of connected porosity, as established from helium adsorption, to the total porosity, as estimated from SANS/USANS techniques. Open porosity appears to control permeability (determined using pressure and pulse-decay techniques), with the highest permeability sample also having the highest percentage of open porosity. Surface area, as calculated from low-pressure N2 and CO2 adsorption, is significantly less than surface area estimates from SANS/USANS, which is due in part to limited accessibility of the gases to all pores. The similarity between N2 and CO2-accessible surface area suggests an absence of microporosity in these samples, which is in agreement with SANS analysis. A core gamma ray profile run on the same core from which the core plug samples were taken correlates to profile permeability measurements run on the slabbed core. This correlation is related to clay content, which possibly controls the percentage of open porosity. Continued study of these effects will prove useful in log-core calibration efforts for tight gas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cold–formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis provides an experimental and computational platform for investigating the performance and behaviour of water filled, plastic portable road safety barriers in an isolated impact scenario. A schedule of experimental impact tests were conducted assessing the impact response of an existing design of road safety barrier utilising a novel horizontal impact testing system. A coupled finite element and smooth particle hydrodynamic model of the barrier system was developed and validated against the results of the experimental tests. The validated model was subsequently used to assess the effect of certain composite materials on the impact performance of the water filled, portable road safety barrier system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cross-sectional survey was conducted, and the construct validity and reliability of the Brisbane Practice Environment Measure in an Australian sample of registered nurses were examined. Nurses were randomly selected from the database of an Australian nursing organization. The original 33 items of the Brisbane Practice Environment Measure were utilized to inform the psychometric properties using confirmatory factor analysis. The Cronbach's alpha was 0.938 for the total scale and ranged 0.657–0.887 for the subscales. A five-factor structure of the measure was confirmed, χ2 = 944.622, (P < 0.01), χ2/d.f. ratio = 2.845, Tucker Lewis Index 0.929, Root Mean Square Error = 0.061 and Comparative Fit Index = 0.906. The selected 28 items of the measure proved reliable and valid in measuring effects of the practice environment upon Australian nurses. The implications are that regular measurement of the practice environment using these 28 items might assist in the development of strategies which might improve job satisfaction and retention of registered nurses in Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis examines the effectiveness of offences in the Copyright Act 1968 (Cth) in the online environment. The application of social norm theories suggests that the offences will be ineffective in creating an effective deterrent to non-commercial copyright infringement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goals of this project were to determine the education and training needs of health consumers and the relevant health workforce and to identify and map the available education and training activities and resources. The methods used to collect the data included online surveys and one on one interviews of relevant patients and their carers. The project manager actively sought to engage with the key wound management leaders and advanced clinicians to gain their support and views on the priority education and training issues. The response to all data collection methods was pleasing with almost five hundred responses to the general wound workforce online survey. The data supported the need for more wound management education and training and identified some particular topics of need, such as utilising wound investigations and understanding wound products, pharmaceuticals and devices. The occupational groups with the highest need appear to be those working in primary health care, such as practice nurses and GPs, and those working in residential aged care facilities. The education and training stocktake identified a wide range of activities currently available, the majority being provided in a face to face format. The next stage of the project will be to form some clear and achievable priority action areas based on the available data. An online directory of wound management education and training activities and resources will be developed and further development will be undertaken on a knowledge and skills framework for the wound management workforce. Additionally, transfer of learning factors in the general practice environment will be assessed and strategies will be developed to improve the pre-entry or undergraduate wound management training within relevant higher education programs.