921 resultados para test development


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Making research relevant to development is a complex, non-linear and often unpredictable process which requires very particular skills and strategies on the part of researchers. The National Centre of Competence in Research (NCCR) North-South provides financial and technical support for researchers so that they can effectively cooperate with policy-makers and practitioners. An analysis of 10 years of experience translating research into development practise in the NCCR North-South revealed the following four strategies as particularly relevant: a) research orientation towards the needs and interests of partners; b) implementation of promising methods and approaches; c) communication and dissemination of research results; and d) careful analysis of the political context through monitoring and learning approaches. The NCCR North-South experience shows that “doing excellent research” is just one piece of the mosaic. It is equally important to join hands with non-academic partners from the very beginning of a research project, in order to develop and test new pathways for sustainable development. Capacity building – in the North and South – enables researchers to do both: To do excellent research and to make it relevant for development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is the first part of a study investigating a model-based transient calibration process for diesel engines. The motivation is to populate hundreds of parameters (which can be calibrated) in a methodical and optimum manner by using model-based optimization in conjunction with the manual process so that, relative to the manual process used by itself, a significant improvement in transient emissions and fuel consumption and a sizable reduction in calibration time and test cell requirements is achieved. Empirical transient modelling and optimization has been addressed in the second part of this work, while the required data for model training and generalization are the focus of the current work. Transient and steady-state data from a turbocharged multicylinder diesel engine have been examined from a model training perspective. A single-cylinder engine with external air-handling has been used to expand the steady-state data to encompass transient parameter space. Based on comparative model performance and differences in the non-parametric space, primarily driven by a high engine difference between exhaust and intake manifold pressures (ΔP) during transients, it has been recommended that transient emission models should be trained with transient training data. It has been shown that electronic control module (ECM) estimates of transient charge flow and the exhaust gas recirculation (EGR) fraction cannot be accurate at the high engine ΔP frequently encountered during transient operation, and that such estimates do not account for cylinder-to-cylinder variation. The effects of high engine ΔP must therefore be incorporated empirically by using transient data generated from a spectrum of transient calibrations. Specific recommendations on how to choose such calibrations, how many data to acquire, and how to specify transient segments for data acquisition have been made. Methods to process transient data to account for transport delays and sensor lags have been developed. The processed data have then been visualized using statistical means to understand transient emission formation. Two modes of transient opacity formation have been observed and described. The first mode is driven by high engine ΔP and low fresh air flowrates, while the second mode is driven by high engine ΔP and high EGR flowrates. The EGR fraction is inaccurately estimated at both modes, while EGR distribution has been shown to be present but unaccounted for by the ECM. The two modes and associated phenomena are essential to understanding why transient emission models are calibration dependent and furthermore how to choose training data that will result in good model generalization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Students frequently hold a number of misconceptions related to temperature, heat and energy. There is not currently a concept inventory with sufficiently high internal reliability to assess these concept areas for research purposes. Consequently, there is little data on the prevalence of these misconceptions amongst undergraduate engineering students. PURPOSE (HYPOTHESIS) This work presents the Heat and Energy Concept Inventory (HECI) to assess prevalent misconceptions related to: (1) Temperature vs. Energy, (2) Temperature vs. Perceptions of Hot and Cold, (3) Factors that affect the Rate vs. Amount of Heat Transfer and (4) Thermal Radiation. The HECI is also used to document the prevalence of misconceptions amongst undergraduate engineering students. DESIGN/METHOD Item analysis, guided by classical test theory, was used to refine individual questions on the HECI. The HECI was used in a one group, pre-test-post-test design to assess the prevalence and persistence of targeted misconceptions amongst a population of undergraduate engineering students at diverse institutions. RESULTS Internal consistency reliability was assessed using Kuder-Richardson Formula 20; values were 0.85 for the entire instrument and ranged from 0.59 to 0.76 for the four subcategories of the HECI. Student performance on the HECI went from 49.2% to 54.5% after instruction. Gains on each of the individual subscales of the HECI, while generally statistically significant, were similarly modest. CONCLUSIONS The HECI provides sufficiently high estimates of internal consistency reliability to be used as a research tool to assess students' understanding of the targeted concepts. Use of the instrument demonstrates that student misconceptions are both prevalent and resistant to change through standard instruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigates the effect of cell phones on economic development and growth by performing an econometric analysis using data from the International Telecommunications Union and the Penn World Table. It discusses the various ways cell phones can make markets more efficient and how the diffusion of information andknowledge plays into development. Several approaches (OLS, Fixed Effects, 2SLS) were used to test over 20 econometric models. Overall, the mobile cellular subscriptions rate was found to have a positive and significant impact on countries’ level of real per capitaGDP and GDP growth rate. Furthermore, the study provides policy implications for the use of technology to promote global growth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study deals with the development of the retentive forces of double crowns intraorally measured. Twenty-five combined fixed-removable prostheses with a total of 84 double crowns were included in the study. The intraoral measurement was performed at 72 defined measuring points directly adjacent to the double crowns of the dentures. The measurement was performed 4-6 weeks (baseline), 6 months (recall 1), and 18 months (recall 2) after the insertion of the restoration. A specifically designed measuring device was used. The median values for the single measuring points reached 4.705 N at the baseline, 5.190 N after 6 months, and 3.740 N after 18 months. The measured values were analyzed according to differences between the median retention forces at the three defined points in time. The statistical analysis of the median values showed no statistical difference for the retention force change after 6 months but for the decrease until the second recall (Mann-Whitney test). The retention force per denture was calculated by a summation of the single measuring points. At the baseline, 12.9 N was reached. The forces did only decrease slightly and were not statistically significant. The results indicate that retention force values of double crowns, measured intraorally at the patient, do not relevantly change clinically within the first 1.5 years. Within the limitations of this study, it can be stated that wear does not influence the retentive forces of double crowns within the first 18 months. After this period the retention force should be still sufficient for denture retention.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper is to examine ways in which pedagogy and gender of instructor impact the development of self-regulated learning strategies as assessed by the Motivated Strategies for Learning Questionnaire (MSLQ) in male and female undergraduate engineering students. Pedagogy was operationalized as two general formats: lecture plus active learning techniques or problem-base/project-based learning. One hundred seventy-six students from four universities participated in the study. Within-group analyses found significant differences with regard to pedagogy, instructors’ gender, and student gender on the learning strategies and motivation subscales as operationalized by the MSLQ. Male and females students reported significant post-test differences with regard to the gender of instructor and the style of pedagogy. The results of this study showed a pattern where more positive responses for students of both genders were found with the same-gendered instructor. The results also suggested that male students responded more positively to project and problem-based courses with changes evidenced in motivation strategies and resource management. Female students showed decreases in resource management in these two types of courses. Further, female students reported increases in the lecture with active learning courses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vascular and soft tissue calcification contributes to cardiovascular morbidity and mortality in both the general population and CKD. Because calcium and phosphate serum concentrations are near supersaturation, the balance of inhibitors and promoters critically influences the development of calcification. An assay that measures the overall propensity for calcification to occur in serum may have clinical use. Here, we describe a nanoparticle-based assay that detects, in the presence of artificially elevated calcium and phosphate concentrations, the spontaneous transformation of spherical colloidal primary calciprotein particles (CPPs) to elongate crystalline secondary CPPs. We used characteristics of this transition to describe the intrinsic capacity of serum to inhibit the precipitation of calcium and phosphate. Using this assay, we found that both the sera of mice deficient in fetuin-A, a serum protein that inhibits calcification, and the sera of patients on hemodialysis have reduced intrinsic properties to inhibit calcification. In summary, we developed a nanoparticle-based test that measures the overall propensity for calcification in serum. The clinical use of the test requires evaluation in a prospective study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PurposeTo investigate the causal relationship between acute postoperative endophthalmitis (POE) after cataract surgery and the biomaterial properties of the intraocular lens (IOLs) implanted.MethodsThis retrospective cohort study included all patients who had undergone cataract surgery with IOL implantation at the Lyon Croix-Rousse University Hospital between 1st January 1994 and 31st December 2004. Details respecting the type of IOL implanted (material and manufacturer) were meticulously recorded. The number of patients presenting with POE within 6 weeks of cataract surgery was documented together with their medical characteristics. These data were then compared, and Fisher's exact test was used to establish the significance of any apparent associations.ResultsEight of the 5837 eyes manifested acute POE (0.14%). Seven of these were composed of polymethylmethacrylate (PMMA) and one of heparinized PMMA. Patients with PMMA IOLs carried a higher risk of developing POE than did those implanted with either heparinized PMMA (P=0.001), hydrophilic acrylic, or hydrophobic acrylic IOLs (P=0.002).ConclusionsThe incidence of acute POE after cataract surgery in our hospital is similar to that currently reported for other institutions in developed countries. Our results add further evidence that IOL material and type are factors contributing to the risk to develop an acute POE after cataract surgery, and that PMMA IOLs may be associated with an increased risk of POE.Eye advance online publication, 15 September 2006; doi:10.1038/sj.eye.6702544.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diagnosis of udder infections with Staphylococcus aureus by bacteriological milk testing of quarter milk samples is often not satisfactory. To get reliable results, repeated sampling is necessary, which is normally too expensive. Therefore, we developed a test that allows the highly specific detection of Staph. aureus in bovine milk samples at very low concentrations. It is based on a fast procedure to prepare bacteria from milk, followed by DNA extraction and quantitative PCR. The whole analysis is done within 5 h. For clinical milk samples, the analytical sensitivity of the assay was 50.7 times and 507 times higher than conventional bacteriology with 100 and 10 microL, respectively. The diagnostic specificity was 100%. The test is further characterized by a low intra- and interassay variability as well as by a good recovery of Staph. aureus from raw milk. Furthermore, a high correlation (R = 0.925) between the agar plate counts and the quantitative PCR methodology over the whole range of measurement was found. In addition, our test revealed considerably more positive results than bacteriology. Due to its favorable properties, the assay might become an important diagnostic tool in the context of bovine mastitis caused by Staph. aureus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A heterozygous missense mutation in the GH-1 gene converting codon 77 from arginine (R) to cysteine (C), which was previously reported to have some GH antagonistic effect, was identified in a Syrian family. The index patient, a boy, was referred for assessment of his short stature (-2.5 SDS) at the age of 6 years. His mother and grandfather were also carrying the same mutation, but did not differ in adult height from the other unaffected family members. Hormonal examination in all affected subjects revealed increased basal GH, low IGF-I concentrations, and subnormal IGF-I response in generation test leading to the diagnosis of partial GH insensitivity. However, GH receptor gene (GHR) sequencing demonstrated no abnormalities. As other family members carrying the GH-R77C form showed similar alterations at the hormonal level, but presented with normal final height, no GH therapy was given to the boy, but he was followed through his pubertal development which was delayed. At the age of 20 years he reached his final height, which was normal within his parental target height. Functional characterization of the GH-R77C, assessed through activation of Jak2/Stat5 pathway, revealed no differences in the bioactivity between wild-type-GH (wt-GH) and GH-R77C. Detailed structural analysis indicated that the structure of GH-R77C, in terms of disulfide bond formation, is almost identical to that of the wt-GH despite the introduced mutation (Cys77). Previous studies from our group demonstrated a reduced capability of GH-R77C to induce GHR/GH-binding protein (GHBP) gene transcription rate when compared with wt-GH. Therefore, reduced GHR/GHBP expression might well be the possible cause for the partial GH insensitivity found in our patients. In addition, this group of patients deserve further attention because they could represent a distinct clinical entity underlining that an altered GH peptide may also have a direct impact on GHR/GHBP gene expression causing partial GH insensitivity. This might be responsible for the delay of growth and pubertal development. Finally, we clearly demonstrate that GH-R77C is not invariably associated with short stature, but that great care needs to be taken in ascribing growth failure to various heterozygous mutations affecting the GH-IGF axis and that careful functional studies are mandatory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the introduction of the rope-pump in Nicaragua in the 1990s, the dependence on wells in rural areas has grown steadily. However, little or no attention is paid to rope-pump well performance after installation. Due to financial restraints, groundwater resource monitoring using conventional testing methods is too costly and out of reach of rural municipalities. Nonetheless, there is widespread agreement that without a way to quantify the changes in well performance over time, prioritizing regulatory actions is impossible. A manual pumping test method is presented, which at a fraction of the cost of a conventional pumping test, measures the specific capacity of rope-pump wells. The method requires only sight modifcations to the well and reasonable limitations on well useage prior to testing. The pumping test was performed a minimum of 33 times in three wells over an eight-month period in a small rural community in Chontales, Nicaragua. Data was used to measure seasonal variations in specific well capacity for three rope-pump wells completed in fractured crystalline basalt. Data collected from the tests were analyzed using four methods (equilibrium approximation, time-drawdown during pumping, time-drawdown during recovery, and time-drawdown during late-time recovery) to determine the best data-analyzing method. One conventional pumping test was performed to aid in evaluating the manual method. The equilibrim approximation can be performed while in the field with only a calculator and is the most technologically appropriate method for analyzing data. Results from this method overestimate specific capacity by 41% when compared to results from the conventional pumping test. The other analyes methods, requiring more sophisticated tools and higher-level interpretation skills, yielded results that agree to within 14% (pumping phase), 31% (recovery phase) and 133% (late-time recovery) of the conventional test productivity value. The wide variability in accuracy results principally from difficulties in achieving equilibrated pumping level and casing storage effects in the puping/recovery data. Decreases in well productivity resulting from naturally occuring seasonal water-table drops varied from insignificant in two wells to 80% in the third. Despite practical and theoretical limitations on the method, the collected data may be useful for municipal institutions to track changes in well behavior, eventually developing a database for planning future ground water development projects. Furthermore, the data could improve well-users’ abilities to self regulate well usage without expensive aquifer characterization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study describes the development and establishment of a proposed Simple Performance Test (SPT) specification in order to contribute to the asphalt materials technology in the state of Michigan. The properties and characteristic of materials, performance testing of specimens, and field analyses are used in developing draft SPT specifications. These advanced and more effective specifications should significantly improve the qualities of designed and constructed hot mix asphalt (HMA) leading to improvement in pavement life in Michigan. The objectives of this study include the following: 1) using the SPT, conduct a laboratory study to measure the parameters including the dynamic modulus terms (E*/sinϕ and E*) and the flow number (Fn) for typical Michigan HMA mixtures, 2) correlate the results of the laboratory study to field performance as they relate to flexible pavement performance (rutting, fatigue, and low temperature cracking), and 3) make recommendations for the SPT criteria at specific traffic levels (e.g. E3, E10, E30), including recommendations for a draft test specification for use in Michigan. The specification criteria of dynamic modulus were developed based upon field rutting performance and contractor warranty criteria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Organic amendments are commonly used to improve tree nursery soil conditions for increased seedling growth. However, few studies compare organic amendments effects on soil conditions, and fewer compare subsequent effects on seedling growth. The effects of three organic amendments on soil properties and seedling growth were investigated at the USDA Forest Service J.W. Toumey Nursery in Watersmeet, MI. Pine sawdust (red pine, Pinus resinosa), hardwood sawdust (maple, Acer spp. and aspen, Populus spp.), and peat were individually incorporated into a loamy sand nursery soil in August, 2006, and soil properties were sampled periodically for the next 14 months. Jack (Pinus banksiana), red, and white pine (Pinus strobus) were sown into test plots in June, 2007 and sampled for growth responses at the end of the growing season. It is hypothesized; pine sawdust and peat can be used as a satisfactory soil amendment to improve soil conditions and produce high quality seedlings, when compared to hardwood sawdust in bareroot nursery soils. This study has the potential to reduce nursery costs while broadening soil amendment options. The addition of peat and pine sawdust increased soil organic matter above control soil conditions after 14 months. However, hardwood sawdust-amended soils did not differ from control soils after same time period. High N concentrations in peat increased total soil N over the other treatments. Similarly, the addition of peat increased soil matric potential and available water over all other treatments. Seedlings grew tallest with the largest stem diameter, and had the largest biomass in both control soil and soil amended with peat, compared to either sawdust treatment. Seedlings grown in peat-amended soils had higher N concentrations than those grown in soils treated with pine sawdust, though neither was different from seedlings grown in control or hardwood sawdust-amended soils. Overall, peat is a well suited organic soil amendment for the enhancement of soil properties, but no amendments were able to increase one-year seedling growth over control soils.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Micro Combined Heat and Power (Micro-CHP) system produces both electricity and heat required for residential or small business applications. Use of Micro-CHP in a residential application not only creates energy and economic savings but also reduces the carbon foot print of the house or small business. Additionally, micro-CHP can subsidize its cost of operation by selling excess electricity produced back to the grid. Even though Micro-CHP remains attractive on paper, high initial cost and optimization issues in residential scale heat and electrical requirement has kept this technology from becoming a success. To understand and overcome all disadvantages posed my Micro-CHP system, a laboratory is developed to test different scenarios of Micro-CHP applications so that we can learn and improve the current technology. This report focuses on the development of this Micro-CHP laboratory including installation of Ecopower micro-CHP unit, developing fuel line and exhaust line for Ecopower unit, design of electrical and thermal loop, installing all the instrumentation required for data collection on the Ecopower unit and developing controls for heat load simulation using thermal loop. Also a simulation of Micro-CHP running on Syngas is done in Matlab. This work was supported through the donation of ‘Ecopower’ a Micro-CHP unit by Marathon Engine and through the support of Michigan Tech REF-IF grand.