862 resultados para subjective and objective video quality assessment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ongoing development of the digital media has brought a new set of challenges with it. As images containing more than three wavelength bands, often called spectral images, are becoming a more integral part of everyday life, problems in the quality of the RGB reproduction from the spectral images have turned into an important area of research. The notion of image quality is often thought to comprise two distinctive areas – image quality itself and image fidelity, both dealing with similar questions, image quality being the degree of excellence of the image, and image fidelity the measure of the match of the image under study to the original. In this thesis, both image fidelity and image quality are considered, with an emphasis on the influence of color and spectral image features on both. There are very few works dedicated to the quality and fidelity of spectral images. Several novel image fidelity measures were developed in this study, which include kernel similarity measures and 3D-SSIM (structural similarity index). The kernel measures incorporate the polynomial, Gaussian radial basis function (RBF) and sigmoid kernels. The 3D-SSIM is an extension of a traditional gray-scale SSIM measure developed to incorporate spectral data. The novel image quality model presented in this study is based on the assumption that the statistical parameters of the spectra of an image influence the overall appearance. The spectral image quality model comprises three parameters of quality: colorfulness, vividness and naturalness. The quality prediction is done by modeling the preference function expressed in JNDs (just noticeable difference). Both image fidelity measures and the image quality model have proven to be effective in the respective experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The service quality of any sector has two major aspects namely technical and functional. Technical quality can be attained by maintaining technical specification as decided by the organization. Functional quality refers to the manner which service is delivered to customer which can be assessed by the customer feed backs. A field survey was conducted based on the management tool SERVQUAL, by designing 28 constructs under 7 dimensions of service quality. Stratified sampling techniques were used to get 336 valid responses and the gap scores of expectations and perceptions are analyzed using statistical techniques to identify the weakest dimension. To assess the technical aspects of availability six months live outage data of base transceiver were collected. The statistical and exploratory techniques were used to model the network performance. The failure patterns have been modeled in competing risk models and probability distribution of service outage and restorations were parameterized. Since the availability of network is a function of the reliability and maintainability of the network elements, any service provider who wishes to keep up their service level agreements on availability should be aware of the variability of these elements and its effects on interactions. The availability variations were studied by designing a discrete time event simulation model with probabilistic input parameters. The probabilistic distribution parameters arrived from live data analysis was used to design experiments to define the availability domain of the network under consideration. The availability domain can be used as a reference for planning and implementing maintenance activities. A new metric is proposed which incorporates a consistency index along with key service parameters that can be used to compare the performance of different service providers. The developed tool can be used for reliability analysis of mobile communication systems and assumes greater significance in the wake of mobile portability facility. It is also possible to have a relative measure of the effectiveness of different service providers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The daily-to-day of medical practice is marked by a constant search for an accurate diagnosis and therapeutic assessment. For this purpose the doctor serves up a wide variety of imaging techniques, however, the methods using ionizing radiation still the most widely used because it is considered cheaper and above all very efficient when used with control and quality. The optimization of the risk-benefit ratio is considered a major breakthrough in relation to conventional radiology, though this is not the reality of computing and digital radiology, where Brazil has not established standards and protocols for this purpose. This work aims to optimize computational chest radiographs (anterior-posterior projection-AP). To achieve this objective were used a homogeneous phantoms that simulate the characteristics of absorption and scattering of radiation close to the chest of a patient standard. Another factor studied was the subjective evaluation of image quality, carried out by visual grading assessment (VGA) by specialists in radiology, using an anthropomorphic phantom to identify the best image for a particular pathology (fracture or pneumonia). Quantifying the corresponding images indicated by the radiologist was performed from the quantification of physical parameters (Detective Quantum Efficiency - DQE, Modulation Transfer Function - MTF and Noise Power Spectrum - NPS) using the software MatLab®. © 2013 Springer-Verlag.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A crescente utilização dos serviços de telecomunicações principalmente sem fio tem exigido a adoção de novos padrões de redes que ofereçam altas taxas de transmissão e que alcance um número maior de usuários. Neste sentido o padrão IEEE 802.16, no qual é baseado o WiMAX, surge como uma tecnologia em potencial para o fornecimento de banda larga na próxima geração de redes sem fio, principalmente porque oferece Qualidade de Serviço (QoS) nativamente para fluxos de voz, dados e vídeo. A respeito das aplicações baseadas vídeo, tem ocorrido um grande crescimento nos últimos anos. Em 2011 a previsão é que esse tipo de conteúdo ultrapasse 50% de todo tráfego proveniente de dispositivos móveis. Aplicações do tipo vídeo têm um forte apelo ao usuário final que é quem de fato deve ser o avaliador do nível de qualidade recebida. Diante disso, são necessárias novas formas de avaliação de desempenho que levem em consideração a percepção do usuário, complementando assim as técnicas tradicionais que se baseiam apenas em aspectos de rede (QoS). Nesse sentido, surgiu a avaliação de desempenho baseada Qualidade de Experiência (QoE) onde a avaliação do usuário final em detrimento a aplicação é o principal parâmetro mensurado. Os resultados das investigações em QoE podem ser usados como uma extensão em detrimento aos tradicionais métodos de QoS, e ao mesmo tempo fornecer informações a respeito da entrega de serviços multimídias do ponto de vista do usuário. Exemplos de mecanismos de controle que poderão ser incluídos em redes com suporte a QoE são novas abordagens de roteamento, processo de seleção de estação base e tráfego condicionado. Ambas as metodologias de avaliação são complementares, e se usadas de forma combinada podem gerar uma avaliação mais robusta. Porém, a grande quantidade de informações dificulta essa combinação. Nesse contexto, esta dissertação tem como objetivo principal criar uma metodologia de predição de qualidade de vídeo em redes WiMAX com uso combinado de simulações e técnicas de Inteligência Computacional (IC). A partir de parâmetros de QoS e QoE obtidos através das simulações será realizado a predição do comportamento futuro do vídeo com uso de Redes Neurais Artificiais (RNA). Se por um lado o uso de simulações permite uma gama de opções como extrapolação de cenários de modo a imitar as mesmas situações do mundo real, as técnicas de IC permitem agilizar a análise dos resultados de modo que sejam feitos previsões de um comportamento futuro, correlações e outros. No caso deste trabalho, optou-se pelo uso de RNAs uma vez que é a técnica mais utilizada para previsão do comportamento, como está sendo proposto nesta dissertação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SynopsisBackgroundCellulite refers to skin relief alterations in womens thighs and buttocks, causing dissatisfaction and search for treatment. Its physiopathology is complex and not completely understood. Many therapeutic options have been reported with no scientific evidence about benefits. The majority of the studies are not controlled nor randomized; most efficacy endpoints are subjective, like not well-standardized photographs and investigator opinion. Objective measures could improve severity assessment. Our purpose was to correlate non-invasive instrumental measures and standardized clinical evaluation.MethodsTwenty six women presenting cellulite on buttocks, aged from 25 to 41, were evaluated by: body mass index; standardized photography analysis (10-point severity and 5-point photonumeric scales) by five dermatologists; cutometry and high-frequency ultrasonography (dermal density and dermis/hypodermis interface length). Quality of life impact was assessed. Correlations between clinical and instrumental parameters were performed.ResultsGood agreement among dermatologists and main investigator perceptions was detected. Positive correlations: body mass index and clinical scores; ultrasonographic measures. Negative correlation: cutometry and clinical scores. Quality of life score was correlated to dermal collagen density.ConclusionCellulite caused impact in quality of life. Poor correlation between objective measures and clinical evaluation was detected. Cellulite severity assessment is a challenge, and objective parameters should be optimized for clinical trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the hygienic and sanitary conditions of pettreats from an export industry. The occurrence of Salmonella, enumerated sulfite-reducing Clostridium (SRC), coagulase-positive Staphylococcus (CPS) and total(TC) and thermotolerant coliforms (TTC) was studied. Of the 108 samples ana-lyzed, 22 were contaminated by some microorganism. TC were detected at twosamples (3.5 × 101and 4.5 × 101colony-forming units [cfu]/g), SRC in 19 samples(1.0 × 101to 1.3 × 105cfu/g) and Salmonella spp. at only one sample; CPS andTTC were not detected. These findings indicate the microbiological safety of mostitems, except for a mix of dried bovine offal, with 1.3 × 105cfu/g of SRC, and onemix of dehydrated bovine viscera contaminated with Salmonella. The current pro-duction processes and the food safety management system are adequate to guar-antee the production of microbiologically safe foods, but that some improvementscan still be made with regard to cleaning and disinfection and hygiene training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a wide range of video services over complex transmission networks, and in some cases end users fail to receive an acceptable quality level. In this paper, the different factors that degrade users' quality of experience (QoE) in video streaming service that use TCP as transmission protocol are studied. In this specific service, impairment factors are: number of pauses, their duration and temporal location. In order to measure the effect that each temporal segment has in the overall video quality, subjective tests. Because current subjective test methodologies are not adequate to assess video streaming over TCP, some recommendations are provided here. At the application layer, a customized player is used to evaluate the behavior of player buffer, and consequently, the end user QoE. Video subjective test results demonstrate that there is a close correlation between application parameters and subjective scores. Based on this fact, a new metrics named VsQM is defined, which considers the importance of temporal location of pauses to assess the user QoE of video streaming service. A useful application scenario is also presented, in which the metrics proposed herein is used to improve video services(1).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The HAM/TSP caused by HTLV-1 infection usually affects patients to disabling states, and sometimes can lead them to paraplegia presenting symptoms of depression and anxiety, impacting on quality of life. Objective: The purpose of this study was to evaluate the frequency of depression and anxiety and its impact on quality of life in HTLV-1-infected TSP/HAM patients. Material and Methods: This was a cross-sectional study including 67 asymptomatic (control group) and 63 with TSP/HAM subjects. The instruments used were a demographic questionnaire, scales for anxiety and depression diagnosis (BDI and BAI), questionnaire for the assessment of Quality of Life of the World Health Organization (WHOQOL-Brief) and neurological scale to measure the disability level (Osame’s Disability Status Scale). All patients had HTLV-I diagnosis by serological and molecular approaches, monitored at Instituto de Infectologia Emílio Ribas from May 2008 to July 2009. Data were analyzed statistically by frequencies, the Mann-Whitney test and the Spearman correlation test. Data among groups were analyzed and correlated with functional and severity aspects. Results: The results showed that patients with HAM/TSP compared to asymptomatic carriers had higher rates of depression (p < 0.001) and anxiety (p < 0.001), and impairment on quality of life in the areas of: dissatisfaction with health (p < 0.001), physical (p < 0.001) and the environment (p = 0.003). The main factors that correlated with levels of depression and anxiety and the domains of the WHOQOL-brief were: education, family income and social class. Conclusion: A well conducted evaluation and counseling may help in treatment, for a better quality of life of these patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Patients' health related quality of life (HRQoL) has rarely been systematically monitored in general practice. Electronic tools and practice training might facilitate the routine application of HRQoL questionnaires. Thorough piloting of innovative procedures is strongly recommended before the conduction of large-scale studies. Therefore, we aimed to assess i) the feasibility and acceptance of HRQoL assessment using tablet computers in general practice, ii) the perceived practical utility of HRQoL results and iii) to identify possible barriers hindering wider application of this approach. Methods Two HRQoL questionnaires (St. George's Respiratory Questionnaire SGRQ and EORTC QLQ-C30) were electronically presented on portable tablet computers. Wireless network (WLAN) integration into practice computer systems of 14 German general practices with varying infrastructure allowed automatic data exchange and the generation of a printout or a PDF file. General practitioners (GPs) and practice assistants were trained in a 1-hour course, after which they could invite patients with chronic diseases to fill in the electronic questionnaire during their waiting time. We surveyed patients, practice assistants and GPs regarding their acceptance of this tool in semi-structured telephone interviews. The number of assessments, HRQoL results and interview responses were analysed using quantitative and qualitative methods. Results Over the course of 1 year, 523 patients filled in the electronic questionnaires (1–5 times; 664 total assessments). On average, results showed specific HRQoL impairments, e.g. with respect to fatigue, pain and sleep disturbances. The number of electronic assessments varied substantially between practices. A total of 280 patients, 27 practice assistants and 17 GPs participated in the telephone interviews. Almost all GPs (16/17 = 94%; 95% CI = 73–99%), most practice assistants (19/27 = 70%; 95% CI = 50–86%) and the majority of patients (240/280 = 86%; 95% CI = 82–91%) indicated that they would welcome the use of electronic HRQoL questionnaires in the future. GPs mentioned availability of local health services (e.g. supportive, physiotherapy) (mean: 9.4 ± 1.0 SD; scale: 1 – 10), sufficient extra time (8.9 ± 1.5) and easy interpretation of HRQoL results (8.6 ± 1.6) as the most important prerequisites for their use. They believed HRQoL assessment facilitated both communication and follow up of patients' conditions. Practice assistants emphasised that this process demonstrated an extra commitment to patient centred care; patients viewed it as a tool, which contributed to the physicians' understanding of their personal condition and circumstances. Conclusion This pilot study indicates that electronic HRQoL assessment is technically feasible in general practices. It can provide clinically significant information, which can either be used in the consultation for routine care, or for research purposes. While GPs, practice assistants and patients were generally positive about the electronic procedure, several barriers (e.g. practices' lack of time and routine in HRQoL assessment) need to be overcome to enable broader application of electronic questionnaires in every day medical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mobile multimedia ad hoc services run on dynamic topologies due to node mobility or failures and wireless channel impairments. A robust routing service must adapt to topology changes with the aim of recovering or maintaining the video quality level and reducing the impact of the user's experience. In those scenarios, beacon-less Opportunistic Routing (OR) increases the robustness by supporting routing decisions in a completely distributed manner based on protocol-specific characteristics. However, the existing beacon-less OR approaches do not efficiently combine multiple metrics for forwarding selection, which cause higher packet loss rate, and consequently reduce the video quality level. In this paper, we assess the robustness and reliability of our recently developed OR protocol under node failures, called cross-layer Link quality and Geographical-aware OR protocol (LinGO). Simulation results show that LinGO achieves multimedia dissemination with QoE support and robustness in scenarios with dynamic topologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose Recovery is a critical link between acute reactions to work-stressors and the development of health-impairments in the long run. Even though recovery is particularly necessary when recovery opportunities during work are insufficient, research on recovery during weekends, is still scarce. To fill this gap we tested, whether the inability to psychologically detach from work mediates the effect of social stressors at work on sleep quality on Sunday night. Design/Methodology Sixty full-time employees participated in the study. Daily assessment included diaries on psychological detachment and ambulatory actigraphy to assess psychophysiological indicators of sleep quality. Results Hierarchical regression analyses revealed social stressors at work to be related with psychological detachment and with several sleep quality parameters on Sunday night. Furthermore, psychological detachment from work mediated the effect of social stressors at work on sleep quality. Limitations Methodological considerations regarding the use of actigraphy data should be taken into account. Research/Practical Implications Our results show that social stressors at work may lower resources just before people get started into the new working week. Originality/Value This is the first study to show that social stressors at work are an antecedent of psychological detachment on Sunday evening and of objective sleep quality on Sunday.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Post-traumatic sleep-wake disturbances are common after acute traumatic brain injury. Increased sleep need per 24 h and excessive daytime sleepiness are among the most prevalent post-traumatic sleep disorders and impair quality of life of trauma patients. Nevertheless, the relation between traumatic brain injury and sleep outcome, but also the link between post-traumatic sleep problems and clinical measures in the acute phase after traumatic brain injury has so far not been addressed in a controlled and prospective approach. We therefore performed a prospective controlled clinical study to examine (i) sleep-wake outcome after traumatic brain injury; and (ii) to screen for clinical and laboratory predictors of poor sleep-wake outcome after acute traumatic brain injury. Forty-two of 60 included patients with first-ever traumatic brain injury were available for follow-up examinations. Six months after trauma, the average sleep need per 24 h as assessed by actigraphy was markedly increased in patients as compared to controls (8.3 ± 1.1 h versus 7.1 ± 0.8 h, P < 0.0001). Objective daytime sleepiness was found in 57% of trauma patients and 19% of healthy subjects, and the average sleep latency in patients was reduced to 8.7 ± 4.6 min (12.1 ± 4.7 min in controls, P = 0.0009). Patients, but not controls, markedly underestimated both excessive sleep need and excessive daytime sleepiness when assessed only by subjective means, emphasizing the unreliability of self-assessment of increased sleep propensity in traumatic brain injury patients. At polysomnography, slow wave sleep after traumatic brain injury was more consolidated. The most important risk factor for developing increased sleep need after traumatic brain injury was the presence of an intracranial haemorrhage. In conclusion, we provide controlled and objective evidence for a direct relation between sleep-wake disturbances and traumatic brain injury, and for clinically significant underestimation of post-traumatic sleep-wake disturbances by trauma patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.