839 resultados para stent coronariano


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To explore the use of telementoring for distant teaching and training in endovascular aortic aneurysm repair (EVAR). METHODS: According to a prospectively designed study protocol, 48 patients underwent EVAR: the first 12 patients (group A) were treated at a secondary care center by an experienced interventionist, who was training the local team; a further 12 patients (group B) were operated by the local team at their secondary center with telementoring by the experienced operator from an adjacent suite; and the last 24 patients (group C) were operated by the local team with remote telementoring support from the experienced interventionist at a tertiary care center. Telementoring was performed using 3 video sources; images were transmitted using 4 ISDN lines. EVAR was performed using intravascular ultrasound and simultaneous fluoroscopy to obtain road mapping of the abdominal aorta and its branches, as well as for identifying the origins of the renal arteries, assessing the aortic neck, and monitoring the attachment of the stent-graft proximally and distally. RESULTS: Average duration of telementoring was 2.1 hours during the first 12 patients (group B) and 1.2 hours for the remaining 24 patients (group C). There was no difference in procedural duration (127+/-59 minutes in group A, 120+/-4 minutes in group B, and 119+/-39 minutes in group C; p=0.94) or the mean time spent in the ICU (26+/-15 hours in group A, 22+/-2 hours in group B, and 22+/-11 hours for group C; p=0.95). The length of hospital stay (11+/-4 days in group A, 9+/-4 days in group B, and 7+/-1 days in group C; p=0.002) was significantly different only for group C versus A (p=0.002). Only 1 (8.3%) patient (in group A: EVAR performed by the experienced operator) required conversion to open surgery because of iliac artery rupture. This was the only conversion (and the only death) in the entire study group (1/12 in group A versus 0/36 in groups B + C, p=0.31). CONCLUSIONS: Telementoring for EVAR is feasible and shows promising results. It may serve as a model for development of similar projects for teaching other invasive procedures in cardiovascular medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The role of angioplasty/stenting procedures, neurointerventionist experience, vascular risk factors, medical treatment and blood flow velocities were analysed to identify possible causes of intra-stent restenosis (ISR) following stenting of cervical and/or intracranial arteries, assuming progressive atherosclerosis to be the shared mechanism in both territories. Patients. 26 cerebrovascular patients subjected to stenting of severe (≥85%) symptomatic or asymptomatic carotid stenoses or moderate-to-severe (≥50%) intracranial or vertebral stenoses were included. METHODS: Clinical, radiological and ultrasonographic follow-up data were analysed retrospectively. RESULTS: Overall, stenting of the internal carotid artery (ICA) induced significant reductions in peak systolic velocities at 2 years (96±31cm/s vs. 358.2±24.9cm/s at baseline). The procedure-related ischemic complications rate was 7.4% (one hemispheric stroke and one TIA). The rate of ISR≤50% was 8% in the ICA at 2 years; was 50% in the common carotid artery (CCA) at 1 year, with concomitant distal ICA stenosis in 75% of CCA stenting, but all ISR were asymptomatic. Patients with ISR of the ICA were significantly younger (56.8±4.5 vs. 71.3±3.6 years, P=0.042) and had significantly more risk factors (5.5±0.9 vs. 3±0.3, P=0.012). No ISR≥70% was detected. CONCLUSIONS: ISR is relatively infrequent and, when present, it is mild and asymptomatic. Restenosis is more frequent in younger patients and those with several risk factors, and it may also be related to stenting of previous carotid endarterectomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To compare safety and efficacy of bridging approach with intravenous (IV) thrombolysis in patients with acute anterior strokes and proximal occlusions. PATIENTS AND METHODS: Consecutive patients with ischemic anterior strokes admitted within a 4 h 30 min window in two different centers were included. The first center performed IV therapy (alteplase 0.6 mg/kg) during 30 min and, in absence of clinical improvement, mechanical thrombectomy with flow restoration using a Solitaire stent (StS); the second carried out IV thrombolysis (alteplase 0.9 mg/kg) alone. Only T, M1 or M2 occlusions present on CT angiography were considered. Endpoints were clinical outcome and mortality at 3 months. RESULTS: There were 63 patients in the bridging and 163 in the IV group. No significant differences regarding baseline characteristics were observed. At 3 months, 46% (n = 29) of the patients treated in the combined and 23% (n = 38) of those treated in the IV group had a modified Rankin scale (mRS) of 0-1 (P < 0.001). A statistical significant difference was observed for all sites of occlusion. In a logistic regression model, National Institute of Health Stroke Scale (NIHSS) and bridging therapy were independent predictors of good outcome (respectively, P = 0.001 and P = 0.0018). Symptomatic hemorrhage was documented in 6.3% vs 3.7% in the bridging and in the IV group, respectively (P = 0.32). There was no difference in mortality. CONCLUSIONS: Our results suggest that patients treated with a bridging approach were more likely to have minimal or no deficit at all at 3 months as compared to the IV treated group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Els stents són unes pròtesis endovasculars. L’objectiu del projecte és el disseny i desenvolupament d’un utillatge que permeti la seva fabricació per tall làser. S’utilitzarà el làser del GREP (Grup de Recerca en Enginyeria de Producte, Procés i Producció) de la Universitat de Girona, el qual està instal•lat sobre el capçal d’un centre de mecanitzat convencional

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fallvignette: Ein 58-jähriger Mann hatte vor einem Jahr einen Herzinfarkt, der mit einem beschichteten Stent versorgt wurde. Im Beruf hat er eine verantwortungsvolle Position und ist häufig geschäftlich unterwegs. Er gibt an, dass er Mühe mit der Einnahme seiner fünf Medikamente (Statin, β-Blocker, ACE-Hemmer, Clopidogrel, Acetylsalizylsäure) hat und dass er ab und zu vergisst, eines zu nehmen. Frage: Könnte ihm ein Kombinationspräparat (Polypille) helfen, seine Medikamente regelmässig einzunehmen? Hintergrund: Weltweit sind Herz-Kreislauf-Erkrankungen die führende Ursache für Tod und Behinderung. Um diese Krankheitslast zu vermindern, ist eine bevölkerungsbezogene Prävention entscheidend, bei der bekannte kardiovaskuläre Risikofaktoren kontrolliert werden. Das Konzept der Polypille mit einer fixen Kombination von mindestens einem Antihypertensivum und einem Statin wurde vor allem in Hinblick auf Entwicklungs- und Schwellenländer entwickelt. Die Primärprävention ist in diesen Ländern schwierig durch führbar; eine einzige Tablette wäre dort eine kostengünstige Variante. Aber auch in reichen Ländern könnte die Polypille sinnvoll sein, um z.B. die Compliance bei multimorbiden Patienten zu verbessern. Als Polypille werden verschiedene Kombinationen von Medikamenten angeboten, ihre Wirksamkeit und möglichen Nebenwirkungen sind jedoch unklar. Ziel dieses Reviews war, ihre Wirksamkeit in der primären und sekundären Prävention bezüglich Mortalität, nicht-tödliche kardiovaskuläre Ereignisse und Blutdruck-bzw. Lipidsenkung zu überprüfen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). METHODS: We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. RESULTS: The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. CONCLUSION: Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To learn upon incidence, underlying mechanisms and effectiveness of treatment strategies in patients with central airway and pulmonary parenchymal aorto-bronchial fistulation after thoracic endovascular aortic repair (TEVAR). METHODS: Analysis of an international multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2012 with a total caseload of 4680 TEVAR procedures (14 centres). RESULTS: Twenty-six patients with a median age of 70 years (interquartile range: 60-77) (35% female) were identified. The incidence of either central airway (aorto-bronchial) or pulmonary parenchymal (aorto-pulmonary) fistulation (ABPF) in the entire cohort after TEVAR in the study period was 0.56% (central airway 58%, peripheral parenchymal 42%). Atherosclerotic aneurysm formation was the leading indication for TEVAR in 15 patients (58%). The incidence of primary endoleaks after initial TEVAR was n = 10 (38%), of these 80% were either type I or type III endoleaks. Fourteen patients (54%) developed central left bronchial tree lesions, 11 patients (42%) pulmonary parenchymal lesions and 1 patient (4%) developed a tracheal lesion. The recognized mechanism of ABPF was external compression of the bronchial tree in 13 patients (50%), the majority being due to endoleak formation, further ischaemia due to extensive coverage of bronchial feeding arteries in 3 patients (12%). Inflammation and graft erosion accounted for 4 patients (30%) each. Cumulative survival during the entire study period was 39%. Among deaths, 71% were attributed to ABPF. There was no difference in survival in patients having either central airway or pulmonary parenchymal ABPF (33 vs 45%, log-rank P = 0.55). Survival with a radical surgical approach was significantly better when compared with any other treatment strategy in terms of overall survival (63 vs 32% and 63 vs 21% at 1 and 2 years, respectively), as well as in terms of fistula-related survival (63 vs 43% and 63 vs 43% at 1 and 2 years, respectively). CONCLUSIONS: ABPF is a rare but highly lethal complication after TEVAR. The leading mechanism behind ABPF seems to be a continuing external compression of either the bronchial tree or left upper lobe parenchyma. In this setting, persisting or newly developing endoleak formation seems to play a crucial role. Prognosis does not differ in patients with central airway or pulmonary parenchymal fistulation. Radical bronchial or pulmonary parenchymal repair in combination with stent graft removal and aortic reconstruction seems to be the most durable treatment strategy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A persistência da veia cava superior esquerda com ausência da veia cava superior direita é uma anomalia rara, com menos de 150 casos descritos na literatura. A não-obliteração e regressão da veia cardinal anterior esquerda durante o desenvolvimento embriológico promove uma variação sistêmica de retorno venoso ao coração, com persistência da veia cava superior esquerda. Sua incidência varia de 0,3% em pacientes sem alterações cardíacas congênitas concomitantes a 4,3% naqueles com cardiopatias. Na maioria das vezes coexiste a veia cava superior direita, porém se houver regressão e degeneração da veia cardinal anterior direita, implicará a sua ausência e a drenagem venosa para o coração será feita pela veia cava superior esquerda ao átrio direito, através do seio coronariano. Mostramos um caso de um paciente submetido a radiografia de tórax e tomografia computadorizada para avaliação de doença pulmonar obstrutiva crônica, tendo como achado a persistência da veia cava superior esquerda com ausência da direita, sem qualquer cardiopatia associada e com a drenagem cardíaca sendo feita, através do seio coronariano, para o átrio direito.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Recently, it has been suggested that the type of stent used in primary percutaneous coronary interventions (pPCI) might impact upon the outcomes of patients with acute myocardial infarction (AMI). Indeed, drug-eluting stents (DES) reduce neointimal hyperplasia compared to bare-metal stents (BMS). Moreover, the later generation DES, due to its biocompatible polymer coatings and stent design, allows for greater deliverability, improved endothelial healing and therefore less restenosis and thrombus generation. However, data on the safety and performance of DES in large cohorts of AMI is still limited. AIM: To compare the early outcome of DES vs. BMS in AMI patients. METHODS: This was a prospective, multicentre analysis containing patients from 64 hospitals in Switzerland with AMI undergoing pPCI between 2005 and 2013. The primary endpoint was in-hospital all-cause death, whereas the secondary endpoint included a composite measure of major adverse cardiac and cerebrovascular events (MACCE) of death, reinfarction, and cerebrovascular event. RESULTS: Of 20,464 patients with a primary diagnosis of AMI and enrolled to the AMIS Plus registry, 15,026 were referred for pPCI and 13,442 received stent implantation. 10,094 patients were implanted with DES and 2,260 with BMS. The overall in-hospital mortality was significantly lower in patients with DES compared to those with BMS implantation (2.6% vs. 7.1%,p < 0.001). The overall in-hospital MACCE after DES was similarly lower compared to BMS (3.5% vs. 7.6%, p < 0.001). After adjusting for all confounding covariables, DES remained an independent predictor for lower in-hospital mortality (OR 0.51,95% CI 0.40-0.67, p < 0.001). Since groups differed as regards to baseline characteristics and pharmacological treatment, we performed a propensity score matching (PSM) to limit potential biases. Even after the PSM, DES implantation remained independently associated with a reduced risk of in-hospital mortality (adjusted OR 0.54, 95% CI 0.39-0.76, p < 0.001). CONCLUSIONS: In unselected patients from a nationwide, real-world cohort, we found DES, compared to BMS, was associated with lower in-hospital mortality and MACCE. The identification of optimal treatment strategies of patients with AMI needs further randomised evaluation; however, our findings suggest a potential benefit with DES.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Important clinical trials and therapeutic advances in the field of cardiology have been presented in 2014. New evidences on the management of acute myocardial infarction and the duration of dual antiplatelet therapy after coronary stent implantation have been published. A new class of therapeutic agents seems to offer promising perspectives for patients with heart failure and reduced ejection fraction. The new generation of subcutaneous or MRI-compatible implantable defibrillators is a major technological breakthrough. Finally, the European Society of Cardiology published new recommendations for the management of patients with cardiovascular diseases. This selective review of the literature summarizes the most important studies in the field of interventional cardiology, rhythmology, heart failure and cardiac imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Analisar a eficiência da angioplastia primária infra-inguinal como método de salvamento de membros em pacientes portadores de lesões tróficas por isquemia crítica. MATERIAIS E MÉTODOS: Foram analisados 36 pacientes submetidos a angioplastias primárias sem stent. Todos os pacientes apresentavam isquemia crítica com lesão trófica - grau III, categoria 5 de Rutherford -, sendo 17 lesões na artéria femoral superficial, 16 na artéria poplítea e 51 em artérias da perna, totalizando 84 angioplastias. Foram analisadas também as prevalências em relação a sexo, membro afetado, idade e principais comorbidades, sendo tecidas considerações técnicas sobre os procedimentos, assim como os materiais utilizados. RESULTADOS: Considerou-se sucesso quando a lesão trófica que motivou a angioplastia cicatrizou, ou o nível de amputação limitou-se a artelhos ou ao antepé, sem ter havido necessidade de procedimento cirúrgico de reconstituição do fluxo sanguíneo (bypass), independentemente de tempo, drogas associadas e números de desbridamentos realizados. CONCLUSÃO: As angioplastias no segmento femoropoplíteo e infrapoplíteo são procedimentos de elevado sucesso técnico, baixa morbidade e mortalidade, constituindo-se procedimento eficaz em pacientes com isquemia crítica de membro inferior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The prognosis of patients with cirrhosis and acute variceal bleeding is very poor when the standard-of-care fails to control bleeding. New treatment modalities are needed in these patients. AIM: To synthesise the available evidence on the efficacy of self-expanding metal stents (SEMS) in patients with cirrhosis and severe or refractory oesophageal variceal bleeding. METHODS: Meta-analysis of trials evaluating SEMS in patients with cirrhosis and severe or refractory oesophageal variceal bleeding. RESULTS: Thirteen studies were included. The pooled estimate rates were 0.40 (95% confidence interval, CI = 0.31-0.49) for death, 0.41 (95% CI = 0.29-0.53) for liver-related death and 0.36 (95% CI = 0.26-0.47) for death at day 30, with low heterogeneity between studies. The pooled estimate rates were 0.12 (95% CI = 0.07-0.21) for mortality related to variceal bleeding, and 0.18 (95% CI = 0.11-0.29) for failure to control bleeding with SEMS, with no or low heterogeneity between studies. The pooled estimate rate were 0.16 (95% CI = 0.04-0.48) for rebleeding after stent removal and 0.28 (95% CI = 0.17-0.43) for stent migration, with high heterogeneity. A significant proportion of patients had access to liver transplantation or to TIPSS [pooled estimate rate 0.10 (95% CI = 0.04-0.21) and 0.26 (95% CI = 0.18-0.36), respectively]. CONCLUSIONS: Fewer than 40% of patients treated with SEMS were dead at 1 month. SEMS can be used as a bridge to TIPSS or to liver transplantation in a significant proportion of patients. Additional studies are required to identify potential risk factors leading to a poor prognosis in patients with acute variceal bleeding in whom the use of SEMS could be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Quantificar a hiperplasia neointimal em artérias ilíacas após stent, correlacionando fatores clínicos, arteriais e materiais dos stents. MATERIAIS E MÉTODOS: De junho de 2003 a agosto de 2005, 60 pacientes realizaram angioplastia transluminal percutânea e stent. Desses, 30 foram reestudados com ultrassonografia intravascular. Os dados foram analisados no laboratório de análise quantitativa. RESULTA-DOS: Dezesseis pacientes eram do sexo masculino (53,3%) e 14 (46,7%), do sexo feminino. A média de idade foi de 60,3 anos. Apresentaram hipertensão arterial 22 pacientes (73,3%), tabagismo, 18 (62,1%), hiperlipidemia, 20 (66,7%), e diabetes, 9 (30%). Foram implantados 20 stents de nitinol (66,7%) e 10 de aço inoxidável (33,3%). Quatro pacientes eram TASC A (13,3%), 15 eram TASC B (50%) e 11, TASC C (36,7%). O volume da hiperplasia variou de 49,02 mm³ a 112,87 mm³ (média de 80,33 mm³). O percentual de obstrução intra-stent variou de 18% a 47% (média de 27,4%). Os resultados clínicos obtidos com stent se mantiveram até o reestudo. CONCLUSÃO: A hiperplasia neointimal sempre ocorre após a angioplastia transluminal percutânea e stent, porém os percentuais de obstrução não foram superiores a 50% em nenhum caso. Não houve diferença estatisticamente significante dos percentuais de obstrução intra-stent quanto aos materiais dos stents, aos fatores clínicos e aos fatores arteriais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A angiotomografia por multidetectores de coronárias constitui um método preciso para avaliação dos enxertos venosos e arteriais pós-revascularização coronariana e vem substituindo em parte o cateterismo, o qual é um método invasivo e de maior custo. Este ensaio iconográfico tem como objetivo a demonstração anatômica dos enxertos mais comumente utilizados, como diferenciar enxertos venosos e arteriais e como localizá-los. Os exames foram realizados em aparelhos de tomografia computadorizada multislice de 64 fileiras de detectores, com apneia, frequência cardíaca controlada e protocolos adequados com posterior reconstruções MPR, MIP e 3D, de acordo com o eletrocardiograma. A localização dos enxertos e anastomoses em tomografias computadorizadas direcionadas para as artérias coronárias e para o tórax pode dificultar a análise do exame pelo radiologista não familiarizado, sendo que o conhecimento das técnicas cirúrgicas utilizadas e dos possíveis trajetos das pontes de safena e enxertos arteriais ajuda na análise de ambos os exames, evitando também erros diagnósticos.