943 resultados para statistical significance


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare the healing and bony crest resorption at implants installed conventionally or applying an edentulous ridge expansion (ERE) technique in the maxilla.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted bilaterally. In the left side of the maxilla (Test), the flaps were elevated and the buccal plate of the alveoli and septa was removed. After 3 months of healing, partial-thickness (split) flaps were dissected and the residual alveolar bone was exposed. In the right side of the maxilla, an implant was installed conventionally (Type IV; Control) while, in the left side, the ERE technique was adopted. Hence, an expansion of the buccal bony crest was obtained, and the implant was subsequently installed (Test). After 3 months of healing, biopsies were obtained and ground sections were prepared for histological analyses.Results: A buccal vertical resorption of the bony crest of 2.2 +/- 1.2 mm and 1.6 +/- 0.7 mm was found at the test and control sites, respectively. The difference, however, did not reach statistical significance. The coronal level of osseointegration at the buccal aspect was located at 3.1 +/- 1.0 mm and 2.2 +/- 0.7 mm from the implant shoulder at the test and control sites, respectively, the difference being statistically significant. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 43% to 48% at the buccal and lingual sites. No differences reached statistical significance.Conclusions: Implants installed by applying an ERE technique may osseointegrate similarly to conventional implant installation. However, vertical and horizontal resorption of the displaced buccal bony wall occurred as well.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To study bony and soft tissue changes at implants installed in alveolar bony ridges of different widths.Material and methods: In 6 Labrador dogs, the mandibular premolars and first molars were extracted, and a buccal defect was created in the left side at the third and fourth premolars by removing the buccal bone and the inter-radicular and interdental septa. Three months after tooth extraction, full-thickness mucoperiosteal flaps were elevated, and implants were installed, two at the reduced (test) and two at the regular-sized ridges (control). Narrow or wide abutments were affixed to the implants. After 3 months, biopsies were harvested, and ground sections prepared for histological evaluation.Results: A higher vertical buccal bony crest resorption was found at the test (1.5 +/- 0.7 mm and 1.0 +/- 0.7 mm) compared to the control implants (1.0 +/- 0.5 mm and 0.7 +/- 0.4 mm), for both wide and narrow abutment sites. A higher horizontal alveolar resorption was identified at the control compared to the test implants. The difference was significant for narrow abutment sites. The peri-implant mucosa was more coronally positioned at the narrow abutment, in the test sites, while for the control sites, the mucosal adaptation was more coronal at the wide abutment sites. These differences, however, did not reach statistical significance.Conclusions: Implants installed in regular-sized alveolar ridges had a higher horizontal, but a lower vertical buccal bony crest resorption compared to implants installed in reduced alveolar ridges. Narrow abutments in reduced ridges as well as wide abutments in regular-sized ridges yielded less soft tissue recession compared to their counterparts.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare the hard tissue changes at implants installed applying edentulous ridge expansion (E.R.E.) at sites with a buccal bony wall thickness of 1 or 2 mm.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted, and the buccal alveolar bony plates and septa were removed. After 3 months of healing, partial-thickness flaps were dissected, and the E.R.E. was applied bilaterally. Hence, an expansion of the buccal bony crest was obtained in both sides of the maxilla with a displacement of either a 1- or a 2-mm-wide buccal bony plate at the test and control sites, respectively. After 3 months of healing, biopsies were obtained for histological analyses.Results: A buccal vertical resorption of the alveolar crest of 2.3 +/- 0.8 and 2.1 +/- 1.1 mm, and a coronal level of osseointegration at the buccal aspect of 2.7 +/- 0.5 and 2.9 +/- 0.9 mm were found at the test (1 mm) and control (2 mm) sites, respectively. The differences did not reach statistical significance. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 62% to 73% at the buccal and lingual sites. No statistically significant differences were found. Horizontal volume gains of 1.8 and 1.1 mm were observed at the test and control sites, respectively, and the difference being statistically significant.Conclusions: Implants installed using the E.R.E. technique yielded a high degree of osseointegration. It is suggested that the displacement of buccal bony plates of 1 mm thickness is preferable compared with that of wider dimensions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study analyzes the repair process of autogenous bone graft in a block fixed with ethyl cyanoacrylate and 2-octyl cyanoacrylate adhesives in rat calvaria. Forty-eight rats, divided into 3 groups, received round osteotomies at the right parietal bone for the attainment of autogenous bone graft fragment, which was fixed at the opposite side to the donor site with ethyl cyanoacrylate (ethyl group) and 2-octyl cyanoacrylate (octyl group) adhesives. In the control group, bone fragment was only juxtaposed at the parietal bone surface without any fixation material. The animals were euthanized after 10 and 60 postoperative days. The calvariae were processed in a laboratory for the attainment of slides stained through the hematoxylin and eosin technique for histological and histometric analysis. The qualitative analysis showed a discrete inflammatory infiltrate in the control group and moderate inflammatory infiltrate in the ethyl and octyl groups at the 10-day period, which remained at the 60-day period, mainly in the octyl group. The bone fragment remained bonded to the recipient site through the adhesive, but graft incorporation was not observed in any of the specimens. Resorption was higher in the octyl group followed by the ethyl and control groups, both at the 10-and 60-day periods, but with no statistical significance (P < .05). Although promoting graft fixation and its maintenance at the recipient site, both studied adhesives did not allow the graft incorporation, producing a localized and discrete inflammatory reaction, which persisted at 60 days, being more intense in the octyl cyanoacrylate group.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biological behavior of the root canal filling sealers: Endofill, Endomethasone and Sealer 26 when in contact with the subcutaneous connective tissue of rat. For the study one control and three experimental groups were used. A total of 15 animals were divided into 5 for each period: 7, 21, and 60 days. The obtained histological sections were processed and stained using the hematoxiline & eosine technique. The histological sections were subjective and comparatively analyzed using optic microscopy. The intensity of the inflammatory reaction and the level of fibrosis of the tissue were registered. The results were registered in scores and statistical analysis by KRUSKAL-WALLIS p<0,05 and MILLER methods. The statistical analysis revealed that in the period of 60 days, there was statistical significance to group II (Endofill) between group (control) and III (Endomethasone) with mononuclear cells into connective tissue. All materials promoted inflammatory reaction more intense at 7 and 21 days with the Endomethasone showing the best results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background There are limited studies on the prevalence and risk factors associated with hepatitis C virus (HCV) infection. Objective Identify the prevalence and risk factors for HCV infection in university employees of the state of São Paulo, Brazil. Methods Digital serological tests for anti-HCV have been performed in 3153 volunteers. For the application of digital testing was necessary to withdraw a drop of blood through a needlestick. The positive cases were performed for genotyping and RNA. Chi-square and Fisher’s exact test were used, with P-value <0.05 indicating statistical significance. Univariate and multivariate logistic regression were also used. Results Prevalence of anti-HCV was 0.7%. The risk factors associated with HCV infection were: age >40 years, blood transfusion, injectable drugs, inhalable drugs (InDU), injectable Gluconergam®, glass syringes, tattoos, hemodialysis and sexual promiscuity. Age (P=0.01, OR 5.6, CI 1.4 to 22.8), InDU (P<0.0001, OR=96.8, CI 24.1 to 388.2), Gluconergam® (P=0.0009, OR=44.4, CI 4.7 to 412.7) and hemodialysis (P=0.0004, OR=90.1, CI 7.5 – 407.1) were independent predictors. Spatial analysis of the prevalence with socioeconomic indices, Gross Domestic Product and Human Development Index by the geoprocessing technique showed no positive correlation. Conclusions The prevalence of HCV infection was 0.7%. The independent risk factors for HCV infection were age, InDU, Gluconergan® and hemodialysis. There was no spatial correlation of HCV prevalence with local economic factors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS