940 resultados para reproducibility of calculated surfaces
Resumo:
Aim: Pleural effusion is common in cancer patients and to determine its malignant origin is of huge clinical significance. PET/CT with 18F-FDG is of diagnostic value in staging and follow-up, but its ability to differentiate between malignant and benign effusions is not precisely known. Patients, methods: We examined 50 PET/CT from 47 patients (29 men, 18 women, 60±16 years) with pleural effusion and known cancer (24 NSCLC, 7 lymphomas, 5 breasts, 4 GIST, 3 mesotheliomas, 2 head and neck, 2 malignant teratoma, 1 colorectal, 1 oesophageal, 1 melanoma) for FDG uptake in the effusions using SUVmax. This was correlated to cytopathology performed after a median of 21 days (interquartile range -3 to 23), which included pH, relative distribution (macrophages, neutrophils, eosinophils, basophils, lymphocytes, plasmocytes), and absolute cell count. Results: Malignant cells were found in 17 effusions (34%) (6 NSCLC, 5 lymphomas, 2 breasts, 2 mesotheliomas, 2 malignant teratomas). SUV in malignant effusions were higher than in benign ones [3.7 (95%CI 1.8-5.6) vs. 1.7 g/ml (1.5-1.9), p = 0.001], with a correlation between malignant effusion and SUV (Spearman coefficient r = 0.50, p = 0.001), but not with other cytopathological or radiological parameters (ROC area 0.83±0.06). Using a 2.2-mg/l SUV threshold, 12 PET/CT studies were positive and 38 negative with sensitivity, specificity, positive and negative predictive values of 53%, 91%, 75% and 79%, respectively. For NSCLC only (n = 24), ROC area was 0.95±0.04, 7 studies were positive and 17 negative with a sensitivity, specificity, positive and negative predictive values of 83%, 89%, 71 and 94%, respectively. Conclusion: PET/CT may help to differentiate the malignant or benign origin of a pleural effusion with a high specificity in patients with known cancer, in particular NSCLC.
Resumo:
Two goals were pursued in this research: first, to evaluate statistically some effects of sample preparation and instrument geometry on reproducibility of X-ray diffraction intensity data; and second, to develop a procedure for finding minimum peak and background counting times for a desired level of accuracy. The ratio of calcite to dolomite in limestones was determined in trials. Ultra-fine wet grinding of the limestone in porcelain impact type ball mill gave most consistent X-ray results, but caused considerable line broadening, and peaks were best measured on an area count basis. Sample spinning reduced variance about one third, and a coarse beam-medium detector slit arrangement was found to be best. An equation is developed relating coefficient of variation of a count ratio to peak and background counts. By use of the equation or graphs the minimum coefficient of variation is predicted from one fast scan, and the number and optimum arrangement of additional counting periods to reduce variation to a desired limit may be obtained. The calculated coefficient is the maximum which may be attributed to the counting statistic but does not include experimental deviations.
Resumo:
PCR methods are reliable and suitable to in situ identify dermatophytes, yeasts and non dermatophyte moulds (NDM) in onychomycosis. Onychomycosis insensitive to standard treatment with topical agents as well as with oral terbinafine or itraconazole revealed Fusarium spp., Acremonium spp. and Aspergillus spp. as infectious agents. However, NDM onychomycosis could be efficiently cured using topical amphotericin B. In conclusion, correct fungal species identification is important in onychomycoses in order to prescribe adequate treatments since dermatophytes and moulds have different sensitivities to antifungal drugs.
Resumo:
The Iowa Department of Transportation research project HR-1013 is the evaluation of a prototype continuous monitoring nuclear density unit. The Unit, the Consolidation Monitoring Device (CMD), mounts on the rear of a slip-form paver and measures the density of the concrete while still in the plastic state. The evaluation performed determined the usefulness, accuracy, precision and reproducibility of the unit. The CMD was calibrated and tested in the laboratory for one week before field evaluation. The field evaluation consisted of monitoring at least 5 miles of paving and then correlating the CMD data with two conventional density methods. The two supplemental methods were density measurement with a Troxler nuclear gauge and densities obtained from core samples.
Resumo:
Epigenetic silencing of the DNA repair protein O(6)-methylguanine-DNA methyltransferase (MGMT) by promoter methylation predicts successful alkylating agent therapy, such as with temozolomide, in glioblastoma patients. Stratified therapy assignment of patients in prospective clinical trials according to tumor MGMT status requires a standardized diagnostic test, suitable for high-throughput analysis of small amounts of formalin-fixed, paraffin-embedded tumor tissue. A direct, real-time methylation-specific PCR (MSP) assay was developed to determine methylation status of the MGMT gene promoter. Assay specificity was obtained by selective amplification of methylated DNA sequences of sodium bisulfite-modified DNA. The copy number of the methylated MGMT promoter, normalized to the beta-actin gene, provides a quantitative test result. We analyzed 134 clinical glioma samples, comparing the new test with the previously validated nested gel-based MSP assay, which yields a binary readout. A cut-off value for the MGMT methylation status was suggested by fitting a bimodal normal mixture model to the real-time results, supporting the hypothesis that there are two distinct populations within the test samples. Comparison of the tests showed high concordance of the results (82/91 [90%]; Cohen's kappa = 0.80; 95% confidence interval, 0.82-0.95). The direct, real-time MSP assay was highly reproducible (Pearson correlation 0.996) and showed valid test results for 93% (125/134) of samples compared with 75% (94/125) for the nested, gel-based MSP assay. This high-throughput test provides an important pharmacogenomic tool for individualized management of alkylating agent chemotherapy.
Resumo:
Assessing the total energy expenditure (TEE) and the levels of physical activity in free-living conditions with non-invasive techniques remains a challenge. The purpose of the present study was to investigate the accuracy of a new uniaxial accelerometer for assessing TEE and physical-activity-related energy expenditure (PAEE) over a 24 h period in a respiratory chamber, and to establish activity levels based on the accelerometry ranges corresponding to the operationally defined metabolic equivalent (MET) categories. In study 1, measurement of the 24 h energy expenditure of seventy-nine Japanese subjects (40 (SD 12) years old) was performed in a large respiratory chamber. During the measurements, the subjects wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd, Nagoya, Japan) on their belt. Two moderate walking exercises of 30 min each were performed on a horizontal treadmill. In study 2, ten male subjects walked at six different speeds and ran at three different speeds on a treadmill for 4 min, with the same accelerometer. O2 consumption was measured during the last minute of each stage and was expressed in MET. The measured TEE was 8447 (SD 1337) kJ/d. The accelerometer significantly underestimated TEE and PAEE (91.9 (SD 5.4) and 92.7 (SD 17.8) % chamber value respectively); however, there was a significant correlation between the two values (r 0.928 and 0.564 respectively; P<0.001). There was a strong correlation between the activity levels and the measured MET while walking (r(2) 0.93; P<0.001). Although TEE and PAEE were systematically underestimated during the 24 h period, the accelerometer assessed energy expenditure well during both the exercise period and the non-structured activities. Individual calibration factors may help to improve the accuracy of TEE estimation, but the average calibration factor for the group is probably sufficient for epidemiological research. This method is also important for assessing the diurnal profile of physical activity.
Resumo:
The aim of this work is to present a new concept, called on-line desorption of dried blood spots (on-line DBS), allowing the direct analysis of a dried blood spot coupled to liquid chromatography mass spectrometry device (LC/MS). The system is based on an inox cell which can receive a blood sample (10 microL) previously spotted on a filter paper. The cell is then integrated into LC/MS system where the analytes are desorbed out of the paper towards a column switching system ensuring the purification and separation of the compounds before their detection on a single quadrupole MS coupled to atmospheric pressure chemical ionisation (APCI) source. The described procedure implies that no pretreatment is necessary in spite the analysis is based on whole blood sample. To ensure the applicability of the concept, saquinavir, imipramine, and verapamil were chosen. Despite the use of a small sampling volume and a single quadrupole detector, on-line DBS allowed the analyses of these three compounds over their therapeutic concentrations from 50 to 500 ng/mL for imipramine and verapamil and from 100 to 1000 ng/mL for saquinavir. Moreover, the method showed good repeatability with relative standard deviation (RSD) lower than 15% based on two levels of concentration (low and high). Function responses were found to be linear over the therapeutic concentration for each compound and were used to determine the concentrations of real patient samples for saquinavir. Comparison of the founded values with those of a validated method used routinely in a reference laboratory showed a good correlation between the two methods. Moreover, good selectivity was observed ensuring that no endogenous or chemical components interfered with the quantitation of the analytes. This work demonstrates the feasibility and applicability of the on-line DBS procedure for bioanalysis.
Resumo:
OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."
Resumo:
In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.
Resumo:
OBJECTIVE: to assess the levels and determinants of interleukin (IL)-1ß, IL-6, tumour necrosis factor (TNF)-a and C-reactive protein (CRP) in a healthy Caucasian population.METHODS: population sample of 2884 men and 3201 women aged 35 to 75. IL-1ß, IL-6 and TNF-a were assessed by a multiplexed particle-based flow cytometric assay and CRP by an immunometric assay.RESULTS: Spearman rank correlations between duplicate cytokine measurements (N?=?80) ranged between 0.89 and 0.96; intra-class correlation coefficients ranged between 0.94 and 0.97, indicating good reproducibility. Among the 6085 participants, 2289 (37.6%), 451 (7.4%) and 43 (0.7%) had IL-1ß, IL-6 and TNF-a levels below detection limits, respectively. Median (interquartile range) for participants with detectable values were 1.17 (0.48-3.90) pg/ml for IL-1ß; 1.47 (0.71-3.53) pg/ml for IL-6; 2.89 (1.82-4.53) pg/ml for TNF-a and 1.3 (0.6-2.7) ng/ml for CRP. On multivariate analysis, greater age was the only factor inversely associated with IL-1ß levels. Male sex, increased BMI and smoking were associated with greater IL-6 levels, while no relationship was found for age and leisure-time PA. Male sex, greater age, increased BMI and current smoking were associated with greater TNF-a levels, while no relationship was found with leisure-time PA. CRP levels were positively related to age, BMI and smoking, and inversely to male sex and physical activity.CONCLUSION: Population-based levels of several cytokines were established. Increased age and BMI, and to a lesser degree sex and smoking, significantly and differentially impact cytokine levels, while leisure-time physical activity has little effect.
Resumo:
OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.
Resumo:
OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.
Resumo:
The value of various indexes to characterize the stimulus-response curve of human motor nerves was assessed in 40 healthy subjects recruited from four European centers of investigation (Créteil, Lausanne, Liège, Marseille). Stimulus-response curves were established by stimulating the right median and ulnar motor nerves at the wrist, with stimulus durations of 0.05 and 0.5 ms. The following parameters were studied: the threshold intensity of stimulation to obtain 10% (I 10), 50% (I 50), and 90% (I 90) of the maximal compound muscle action potential, the ratios I 10/I 50, I 90/I 50, (I 90 - I 10)/I 10, (I 90-I 50)/I 50, and (I 50 - I 10)/I 10, and the slopes of the stimulus-response curves with or without normalization to I 50. For each parameter, within-center variability and reproducibility (in a test-retest study) were assessed and between-center comparisons were made. For most of the parameters, the results varied significantly within and between the centers. Within the centers, only the ratios I 10/I 50 and I 90/I 50 were found constant and reproducible. Between the centers, the absolute intensity thresholds (I 10, I 50, I 90) and the ratio I 90/I 50 did not show significant differences at stimulus duration of 0.5 ms, whatever the stimulated nerve. The reduced variability and good reproducibility of the ratios I 10/I 50 and I 90/I 50 open perspectives in neurophysiological practice for the use of these indexes of the stimulus-response curve, a rapid and noninvasive test.