926 resultados para pediatric anesthesia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary Objective: To document the clinical characteristics of acute dysphagia in a group of pediatric patients after traumatic brain injury (TBI). Research Design: Prospective group study. Methods: Fourteen subjects (7 males, 7 females), aged 4 years 1 month to 15 years, with moderate or severe TBI (Glasgow Coma Scale [GCS] < 12). Subjects were assessed via clinical bedside examination documenting cognitive status, oromotor function, feeding function, dietary recommendations, and an indication of overall feeding severity Results: A pattern of impaired cognition, altered behavior related to feeding, severe tonal and postural deficits, oromotor, respiratory, and laryngeal impairments, and oral sensitivity issues was revealed. Conclusions: Swallowing impairment was affected by multilevel deficits, which both individually and in combination had a negative impact on swallowing competence and safety. In light of deficits identified, which could not be observed on videofluoroscopic investigation alone, this study highlighted the importance of the clinical bedside examination in assessing dysphagia in pediatric patients post-TBI for identifying targets for intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Remote access to pediatric cardiology diagnostic services is enabled by real-time transmission of echocardiographic images. Several transmission bandwidths have been used but there has been little analysis of image quality provided by different bandwidths. We designed a study of the quality of transmitted images at various bandwidths. Methods: Two echocardiographers viewed randomly a series of 13 recorded pediatric echocardiographic images either directly or after transmission using 1 of 4 bandwidths: 256; 384; 512; or 768 kbps. An image clarity scoring scale was used to assess image quality of cardiac structures. Results: Measurable differences were found in image quality with different transmission bandwidths; 512 kbps was the minimum for consistently clear imaging of all cardiac structures examined. Conclusion: Bandwidth greater than 512 kbps confers sharper images subjectively although this could not be quantified by our methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Flexible video bronchoscopes, in particular the Olympus BF Type 3C160, are commonly used in pediatric respiratory medicine. There is no data on the magnification and distortion effects of these bronchoscopes yet important clinical decisions are made from the images. The aim of this study was to systematically describe the magnification and distortion of flexible bronchoscope images taken at various distances from the object. Methods: Using images of known objects and processing these by digital video and computer programs both magnification and distortion scales were derived. Results: Magnification changes as a linear function between 100 mm ( x 1) and 10 mm ( x 9.55) and then as an exponential function between 10 mm and 3 mm ( x 40) from the object. Magnification depends on the axis of orientation of the object to the optic axis or geometrical axis of the bronchoscope. Magnification also varies across the field of view with the central magnification being 39% greater than at the periphery of the field of view at 15 mm from the object. However, in the paediatric situation the diameter of the orifices is usually less than 10 mm and thus this limits the exposure to these peripheral limits of magnification reduction. Intraclass correlations for measurements and repeatability studies between instruments are very high, r = 0.96. Distortion occurs as both barrel and geometric types but both types are heterogeneous across the field of view. Distortion of geometric type ranges up to 30% at 3 mm from the object but may be as low as 5% depending on the position of the object in relation to the optic axis. Conclusion: We conclude that the optimal working distance range is between 40 and 10 mm from the object. However the clinician should be cognisant of both variations in magnification and distortion in clinical judgements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven captive male African wild dogs (Lycaon pictus) weighing 25-32 kg each, were anesthetized by i.m. injection via hand syringe with a combination of 1.5 mg/kg ketamine, 40 mu g/kg medetomidine, and 0.05 mg/kg atropine. Following endotracheal intubation, each animal was connected to a bain closed-circuit system that delivered 1.5% isoflurane and 2 L/min oxygen. Atipamezole (0.1 mg/kg i.v.; 0.1 mg/kg i.m.) was given at the end of each procedure (60 min following injection of medetomidine/ketamine/atropine). Time to sternal recumbency was 5-8 min. Times to standing after atipamezole administration were 8-20 min. This anesthetic regimen was repeated on three separate occasions (September 2000, February 2002, and October 2002) on all males to perform electroejaculation procedures. Each procedure was < 80 min from injection to standing. Dogs showed excellent muscle relaxation during the procedures. Arterial blood samples were collected at 10-min intervals for blood gases in one procedure (September 2000). Separate venous samples were taken from each dog during each procedure for hematology and biochemistry. These values were within the normal range for this species. Arterial hemoglobin oxygen saturation (SpO2) and heart rate (HR) were monitored continuously in addition to other anesthesia monitoring procedures (body temperature, respiratory rate [RR], capillary refill time, blink response, pupil position, deep pain perception reflex). All dogs maintained relatively stable SpO2 profiles during monitoring, with a mean (+/- SD) SpO2 of 92% +/- 5.4%. All other physiological variables (HR, RR, body temperature, blood pressure) were within normal limits. Following each procedure, normal behavior was noted in all dogs. All the dogs were reunited into the pack at completion of their anesthetic procedures. An injectable medetomidine-ketamine-atropine combination with maintenance by gaseous isoflurane and oxygen provides an inexpensive, reliable anesthetic for captive African wild dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain anatomy is characterized by dramatic growth from the end of the second trimester through the neonatal stage. The characterization of normal axonal growth of the white matter tracts has not been well-documented to date and could provide important clues to understanding the extensive inhomogeneity of white matter injuries in cerebral palsy (CP) patients. However, anatomical studies of human brain development during this period are surprisingly scarce and histology-based atlases have become available only recently. Diffusion tensor magnetic resonance imaging (DTMRI) can reveal detailed anatomy of white matter. We acquired diffusion tensor images (DTI) of postmortem fetal brain samples and in vivo neonates and children. Neural structures were annotated in two-dimensional (2D) slices, segmented, measured, and reconstructed three-dimensionally (3D). The growth status of various white matter tracts was evaluated on cross-sections at 19-20 gestational weeks, and compared with 0-month-old neonates and 5- to 6-year-old children. Limbic, commissural, association, and projection white matter tracts and gray matter structures were illustrated in 3D and quantitatively characterized to assess their dynamic changes. The overall pattern of the time courses for the development of different white matter is that limbic fibers develop first and association fibers last and commissural and projection fibers are forming from anterior to posterior part of the brain. The resultant DTNIRI-based 3D human brain data will be a valuable resource for human brain developmental study and will provide reference standards for diagnostic radiology of premature newborns. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador: