1000 resultados para neutralization power
Resumo:
INTRODUCTION: We examined the power spectral changes of the compound muscle action potential (M wave) evoked during isometric contractions of increasing strength. METHODS: Surface electromyography (sEMG) of the vastus lateralis and medialis was recorded from 20 volunteers who performed 4-s step-wise isometric contractions of different intensities. A maximal M wave was elicited by a single stimulus to the femoral nerve and superimposed on the voluntary contractions. The spectral characteristics (Fmean and Fmedian) of sEMG and M-wave signals were calculated. RESULTS: M-wave spectral indicators increased systematically with contraction intensity up to 60% MVC and then leveled off at higher forces. Over the 10-60% MVC range, the increase in spectral indicators was 3 times higher for M waves (36%) than for sEMG (12%). CONCLUSIONS: The consistent increase in M-wave spectral characteristics with force is due to the fact that the number of motor units recruited by the superimposed supramaximal stimulus is approximately stable.
Resumo:
This study deals with the statistical properties of a randomization test applied to an ABAB design in cases where the desirable random assignment of the points of change in phase is not possible. In order to obtain information about each possible data division we carried out a conditional Monte Carlo simulation with 100,000 samples for each systematically chosen triplet. Robustness and power are studied under several experimental conditions: different autocorrelation levels and different effect sizes, as well as different phase lengths determined by the points of change. Type I error rates were distorted by the presence of autocorrelation for the majority of data divisions. Satisfactory Type II error rates were obtained only for large treatment effects. The relationship between the lengths of the four phases appeared to be an important factor for the robustness and the power of the randomization test.
Resumo:
Tutkimuksen tarkoituksena oli selvittää typenoksidien vähennysmahdollisuudet Stora Enson Varkauden tehtaiden sellutehtaalla ja voimalaitoksella. Tutkimuksessa käsiteltiin tehdasalueen suurimpia typenoksidien päästölähteitä: soodakattilaa, meesauunia, kuorikattilaa, öljykattilaa ja muovi-alumiinijakeen kaasutuslaitosta. Tutkimuksessa selvitettiin typenoksidipäästöjen syntymekanismit ja erilaisiin polttotekniikoihin soveltuvat typenoksidien vähennystekniikat. Varkauden tehtaiden typenoksidien vuosipäästö vuonna 2001 oli 836 tonnia. Kansallinen lainsäädäntö, kansainväliset sopimukset sekä paras käytettävissä oleva tekniikka (BAT) huomioiden selvitettiin kuhunkin kohteeseen parhaiten soveltuvat ratkaisut. Tutkimuksen perusteella laadittiin toimenpideohjelma, joka määrittelee suositeltavan toteutusjärjestyksen typenoksidien vähennystoimenpiteille. Toimenpideohjelman tärkeimpinä kriteereinä pidettiin vuonna 2004 tulevan uuden ympäristöluvan arvioituja luparajoja sekä toimenpiteiden kustannustehokkuutta. Toteutusjärjestyksessä ensimmäiseksi valittiin koeajojakson järjestäminen ajon optimoimiseksi kiertopetikattilalla ja toiseksi meesauunin ajon optimointi jatkuvatoimisen NOx-analysaattorin avulla. Seuraaviksi toimenpiteiksi ehdotettiin vertikaali-ilmajärjestelmän käyttöönottoa soodakattilalla sekä SNCR-järjestelmän asennusta kuorikattilalle. Saavutettava NOx-vähennys tulisi olemaan 10 – 45 % ja hinta 30 – 3573 EUR vähennettyä NOx-tonnia kohti. Tutkimuksen osana Ilmatieteen laitoksella teetetyn typenoksidien leviämisselvityksen mukaan Stora Enson tehtaiden NOx-päästöjen vaikutus Varkauden ilmanlaatuun on hyvin pieni. Suurin osa NOx-päästöistä aiheutuu liikenteestä.
Resumo:
Sähkönkulutuksen lyhyen aikavälin ennustamista on tutkittu jo pitkään. Pohjoismaisien sähkömarkkinoiden vapautuminen on vaikuttanut sähkönkulutuksen ennustamiseen. Aluksi työssä perehdyttiin aiheeseen liittyvään kirjallisuuteen. Sähkönkulutuksen käyttäytymistä tutkittiin eri aikoina. Lämpötila tilastojen käyttökelpoisuutta arvioitiin sähkönkulutusennustetta ajatellen. Kulutus ennusteet tehtiin tunneittain ja ennustejaksona käytettiin yhtä viikkoa. Työssä tutkittiin sähkönkulutuksen- ja lämpötiladatan saatavuutta ja laatua Nord Poolin markkina-alueelta. Syötettävien tietojen ominaisuudet vaikuttavat tunnittaiseen sähkönkulutuksen ennustamiseen. Sähkönkulutuksen ennustamista varten mallinnettiin kaksi lähestymistapaa. Testattavina malleina käytettiin regressiomallia ja autoregressiivistä mallia (autoregressive model, ARX). Mallien parametrit estimoitiin pienimmän neliösumman menetelmällä. Tulokset osoittavat että kulutus- ja lämpötiladata on tarkastettava jälkikäteen koska reaaliaikaisen syötetietojen laatu on huonoa. Lämpötila vaikuttaa kulutukseen talvella, mutta se voidaan jättää huomiotta kesäkaudella. Regressiomalli on vakaampi kuin ARX malli. Regressiomallin virhetermi voidaan mallintaa aikasarjamallia hyväksikäyttäen.
Resumo:
Pysyäkseen kilpailukykyisenä vapautuneilla sähkömarkkinoilla on voimalaitoksen energiantuotantokustannusten oltava mahdollisimman matalia, tinkimättä kuitenkaan korkeasta käytettävyydestä. Polttoaineen energiasisällön mahdollisimman hyvä hyödyntäminen on ratkaisevan tärkeää voimalaitoksen kannattavuudelle. Polttoainekustannusten osuus on konvektiivisilla laitoksilla yleensä yli puolet koko elinjakson kustannuksista. Kun vielä päästörajat tiukkenevat koko ajan, korostuu polttoaineen korkea hyötykäyttö entisestään. Korkea energiantuotannon luotettavuus ja käytettävyys ovat myös elintärkeitä pyrittäessä kustannusten minimointiin. Tässä työssä on käyty läpi voimalaitoksen kustannuksiin vaikuttavia käsitteitä, kuten hyötysuhdetta, käytettävyyttä, polttoaineen hintoja, ylös- ja alasajoja ja tärkeimpiä häviöitä. Ajostrategiassa ja poikkeamien hallinnassa pyritään hyvään hyötysuhteeseen ja alhaisiin päästöihin joka käyttötilanteessa. Lisäksi on tarkasteltu tiettyjen suureiden, eli höyryn lämpötilan ja paineen, savukaasun hapen pitoisuuden, savukaasun loppulämpötilan, sekä lauhduttimen paineen poikkeamien vaikutusta ohjearvostaan energiantuotantokustannuksiin. Happi / hiilimonoksidi optimoinnissa on otettu huomioon myös pohjatuhkan palamattomat.
Resumo:
Background The MPER region of the HIV-1 envelope glycoprotein gp41 is targeted by broadly neutralizing antibodies. However, the localization of this epitope in a hydrophobic environment seems to hamper the elicitation of these antibodies in HIV infected individuals. We have quantified and characterized anti-MPER antibodies by ELISA and by flow cytometry using a collection of mini gp41-derived proteins expressed on the surface of 293T cells. Longitudinal plasma samples from 35 HIV-1 infected individuals were assayed for MPER recognition and MPER-dependent neutralizing capacity using HIV-2 viruses engrafted with HIV-1 MPER sequences. Results Miniproteins devoid of the cysteine loop of gp41 exposed the MPER on 293T cell membrane. Anti-MPER antibodies were identified in most individuals and were stable when analyzed in longitudinal samples. The magnitude of the responses was strongly correlated with the global response to the HIV-1 envelope glycoprotein, suggesting no specific limitation for anti-MPER antibodies. Peptide mapping showed poor recognition of the C-terminal MPER moiety and a wide presence of antibodies against the 2F5 epitope. However, antibody titers failed to correlate with 2F5-blocking activity and, more importantly, with the specific neutralization of HIV-2 chimeric viruses bearing the HIV-1 MPER sequence; suggesting a strong functional heterogeneity in anti-MPER humoral responses. Conclusions Anti-MPER antibodies can be detected in the vast majority of HIV-1 infected individuals and are generated in the context of the global anti-Env response. However, the neutralizing capacity is heterogeneous suggesting that eliciting neutralizing anti-MPER antibodies by immunization might require refinement of immunogens to skip nonneutralizing responses.
Resumo:
Natural killer (NK) cells are cytotoxic lymphocytes that substantially contribute to the therapeutic benefit of antitumor antibodies like Rituximab, a crucial component in the treatment of B-cell malignancies. In chronic lymphocytic leukemia (CLL), the ability of NK cells to lyse the malignant cells and to mediate antibody-dependent cellular cytotoxicity upon Fc receptor stimulation is compromised, but the underlying mechanisms are largely unclear. We report here that NK-cells activation-dependently produce the tumor necrosis factor family member 'B-cell activating factor' (BAFF) in soluble form with no detectable surface expression, also in response to Fc receptor triggering by therapeutic CD20-antibodies. BAFF in turn enhanced the metabolic activity of primary CLL cells and impaired direct and Rituximab-induced lysis of CLL cells without affecting NK reactivity per se. The neutralizing BAFF antibody Belimumab, which is approved for treatment of systemic lupus erythematosus, prevented the effects of BAFF on the metabolism of CLL cells and restored their susceptibility to direct and Rituximab-induced NK-cell killing in allogeneic and autologous experimental systems. Our findings unravel the involvement of BAFF in the resistance of CLL cells to NK-cell antitumor immunity and Rituximab treatment and point to a benefit of combinatory approaches employing BAFF-neutralizing drugs in B-cell malignancies.
Resumo:
Several possible methods of increasing the efficiency and power of hydro power plants by improving the flow passages are investigated in this stydy. The theoretical background of diffuser design and its application to the optimisation of hydraulic turbine draft tubes is presented in the first part of this study. Several draft tube modernisation projects that have been carried out recently are discussed. Also, a method of increasing the efficiency of the draft tube by injecting a high velocity jet into the boundary layer is presented. Methods of increasing the head of a hydro power plant by using an ejector or a jet pump are discussed in the second part of this work. The theoretical principles of various ejector and jet pump types are presented and four different methods of calculating them are examined in more detail. A self-made computer code is used to calculate the gain in the head for two example power plants. Suitable ejector installations for the example plants are also discussed. The efficiency of the ejector power was found to be in the range 6 - 15 % for conventional head increasers, and 30 % for the jet pump at its optimum operating point. In practice, it is impossible to install an optimised jet pump with a 30 % efficiency into the draft tube as this would considerabely reduce the efficiency of the draft tube at normal operating conditions. This demonstrates, however, the potential for improvement which lies in conventional head increaser technology. This study is based on previous publications and on published test results. No actual laboratory measurements were made for this study. Certain aspects of modelling the flow in the draft tube using computational fluid dynamics are discussed in the final part of this work. The draft tube inlet velocity field is a vital boundary condition for such a calculation. Several previously measured velocity fields that have successfully been utilised in such flow calculations are presented herein.
Resumo:
In newly formed groups, informal hierarchies emerge automatically and readily. In this study, we argue that emergent group hierarchies enhance group performance (Hypothesis 1) and we assume that the more the power hierarchy within a group corresponds to the task-competence differences of the individual group members, the better the group performs (Hypothesis 2). Twelve three-person groups and 28 four-person groups were investigated while solving the Winter Survival Task. Results show that emerging power hierarchies positively impact group performance but the alignment between task-competence and power hierarchy did not affect group performance. Thus, emergent power hierarchies are beneficial for group performance and although they were on average created around individual group members' competence, this correspondence was not a prerequisite for better group performance.
Resumo:
Gender inequalities remain an issue in our society and particularly in the workplace. Several factors can explain this gender difference in top-level managerial positions such as career ambitions but also biases against women. In our chapter, we propose a model explaining why gender inequalities and particularly discrimination against women is still present in our societies despite social norms and existing legislation on gender equality. To this purpose, we review research on discrimination through two different approaches, (a) a prejudice approach through the justification-suppression model developed by Crandall and Eshleman (2003) and (b) a power approach through the social dominance theory (Pratto, Sidanius, Stallworth, & Malle, 1994; Sidanius & Pratto, 1999). In our work, we integrate these two approaches and propose a model of gender prejudice, power and discrimination. The integration of these two approaches contributes to a better understanding of how discrimination against women is formed and maintained over time.
Resumo:
This master’s thesis handles an operating model for an electric equipment supplier conducted sale oriented energy audit for pumping, fan and other motor applications at power plants. The study goes through the largest factors affecting internal electricity use at a power plant, finds an energy audit –like approach for the basis of information gathering and presents the information needed for conducting the analysis. The model is tested in practice at a kraft recovery boiler of a chemical pulping mill. Targets chosen represent some of the largest electric motor applications in the boiler itself and in its fuel handling. The energy saving potential of the chosen targets is calculated by simulating the energy consumption of the alternatives for controlling the targets, and thereafter combining the information with the volume flow duration curve. Results of the research are somewhat divaricated, as all the information needed is not available in the automation system. Some of the targets could be simulated and their energy saving potential calculated quite easily. At some of the targets chosen the monitoring was not sufficient enough for this and additional measurements would have been needed to base the calculations on. In traditional energy audits, energy efficiency of pump and fan applications is not necessarily examined. This means that there are good possibilities for developing the now presented targeted energy audit procedure basis further.