998 resultados para monitoramento de umidade
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
A borracha natural (BN) de três clones de seringueira [Hevea brasiliensis (Willd. exAdr. de Juss. Muell.-Arg.)] de um período de sete meses foi obtida por coagulação do látex com solução de ácido acético a 10% e seca a 65°C. As curvas TG-DTG foram utilizadas para monitorar as propriedades térmicas da BN. Os resultados indicaram pequenas variações entre clones e coletas, exceto no valor de Tf-T0, indicando que o clone IAC 301 sofre degradação mais rápida durante o processo termo degradação da BN seca. Não houve diferenças significativas nos valores de Tg entre clones e coletas.
Resumo:
Environmental monitoring of aquatic systems is an important tool to support policy makers and environmental managers' decisions. Long-term, continuous collection of environmental data is fundamental to the understanding of an aquatic system. This paper aims to present the integrated system for environmental monitoring (SIMA), a long-term temporal series system with a web-based archive for limnological and meteorological data. The following environmental parameters are measured by SIMA: chlorophyll-a (µgL-1), water surface temperature (ºC), water column temperature by a thermistor string (ºC), turbidity (NTU), pH, dissolved oxygen concentration (mg L-1), electric conductivity (µS cm-1), wind speed (ms-1) and direction (º), relative humidity (%), shortwave radiation (Wm-2) and barometric pressure (hPa). The data were collected in a preprogrammed time interval (1 hour) and were transmitted by satellite in quasi-real time for any user within 2500 km of the acquisition point. So far, 11 hydroelectric reservoirs are being monitored with the SIMA buoy. Basic statistics (mean and standard deviation) and an example of the temporal series of some parameters were displayed at a database with web access. However, sensor and satellite problems occurred due to the high data acquisition frequency. Sensors problems occurred due to the environmental characteristics of each aquatic system. Water quality sensors rapidly degrade in acidic waters, rendering the collected data invalid. Data is also rendered invalid when sensors become infested with periphyton. Problems occur with the satellites' reception of system data when satellites pass over the buoy antenna. However, the data transfer at some inland locations was not completed due to the satellite constellation position. Nevertheless, the integrated system of water quality and meteorological parameters is an important tool in understanding the aquatic system dynamic. It can also be used to create hydrodynamics models of the aquatic system to allow for the study of meteorological implications to the water body.
Resumo:
The sugarcane crop plays an important role on Brazilian economy,, especially in the aspect related to alternative energy sources. Yield of ratoon cane (2nd cycle) was evaluated in relation to resistance to penetration, gravimetric moisture and organic matter in a Typic Tropustalf, in the municipality of Suzanápolis (SP), 20º28'10'' S and 50º49'20'' W, in the Brazilian cerrado, in 2009. The main purpose was to select, among the attributes surveyed, the one with the highest linear and spatial correlations that explains the variability of sugar cane yield. A geostatistical grid was installed in order to collect data from the soil as well from the plant, with 120 sampling points in an area of 14.53 ha. Organic matter correlated linearly and negatively with penetration resistance, indicating that the soil management practices that aim its increase in the soil profile can improve soil physical conditions, and consequently, the development and yield of sugarcane. Both gravimetric moisture (UG) and content of soil organic matter (OM) correlated directly, linearly (UG2 and MO1) and spatially (UG1 and MO1) with sugarcane yield, proving to be the best attributes, among the evaluated ones, to estimate and increase the sugarcane yield.
Resumo:
We studied the molecular epidemiology of Staphylococcus aureus strains potentially toxigenic, isolated from the production process of Minas frescal cheese in a small dairy plant in the state of São Paulo. For this, samples were taken during the period from June 2008 to July 2009. Samples were collected from the surface of the receiving and storage tanks of raw milk, the surface of the balance tank of pasteurized milk, the water supply system, the pipes and equipments, the hands of the handler and from the packaged cheese, totaling 140 samples. The colonies isolated on Baird-Parker Agar confirmed as Gram positive and positive for catalase, coagulase and acetoin production, were submitted to extraction of bacterial DNA using the Invitek - Uniscience® kit. Confirmation of the isolated species and enterotoxins SEA, SEB, SEC, SED and TSST-1 toxin was carried out through the amplification of specific fragments of chromosomal DNA. Among the 74 strains of isolated coagulase-positive staphylococci, only 41 (55.4%) strains were confirmed as Staphylococcus aureus, of which 25 (61.0%) were positive to the presence of staphylococcal toxins. The most frequently identified enterotoxin was SEA. The toxigenic strains of Staphylococcus aureus were more frequently isolated from hands of the handler (16.0%), raw milk receiving tank (12.0%), pasteurized milk for cheese making (12.0%) and fresh white cheese ready for consumption (12.0%).
Resumo:
Data from reference stations are widely used in GNSS (Global Navigation Satellite System) positioning, and can be used in relative positioning or network-based positioning concept. Positioning accuracy will be directly influenced by errors in signals collected in these stations. In this paper, it is aimed at evaluating these data quality using temporal series of multipath index MP1 and MP2. A statistical study of temporal series with 7 years of daily observations related to 7 stations from RBMC (Rede Brasileira de Monitoramento Contínuo) was accomplished. In order to investigate trends and seasonality a linear regression model, correlograms, and Fourier periodograms were used. We also used a harmonic adjust to identify peaks on temporal series. At last, the possible causes of seasonality found in some stations were discussed. It was also possible to identify peaks in MP values of March and October months (mainly in stations located near geomagnetic equator).
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
It is known that the urban environment modifies the energy balance between the surface and the atmosphere, causing changes in temperature, relative humidity, among other things, opening the way for studies aimed at urban climatology. Based on the theme of urban climate, this research focuses on the city of Assis, located west of São Paulo. The generation of urban climate is a result of various factors, among which stand out: the use and different land use, the thermodynamic properties of buildings, number of buildings in the urban, socioeconomic activities, etc.. In general, this increases the temperature and reducing relative humidity, providing thermal discomfort. The rural environment is used for comparison studies to this theme by presenting different characteristics in relation to the structure, morphology and urban functionality. The main objective of this study is to determine the characteristics of temperature and humidity environments with the habits and occupations of the different soils in winter, at night, one inserted into the urban fabric of Assis and the other in the rural environment, to verify for evidence of changes in climatic elements because of urbanization. To collect the data will be used mini automatic weather stations that record data on temperature and humidity. For analysis of the results will be made between the data obtained in the city and the countryside, developing graphics application using Excel to tabulate the data. It was found that there were differences in the thermo-hygrometric data collection points, showing a specific urban climate in the city of Assis
Resumo:
Technological advances and the availability of computational resources have been facilitating the collection and processing of data. Thus, the natural tendency of the monitoring processes is the simultaneous control of various quality characteristics. In automated processes, observations are generally autocorrelated. Studies with univariate graph for processes have shown that the autocorrelation reduces the ability of this signal changes in the process. In this paper, we study the multivariate autocorrelated processes. Through simulations are obtained properties of graphs, monitoring the mean vector, the properties of graphs VMAX, in monitoring the covariance matrix, and the properties of graphs MCMAX, the simultaneous monitoring of mean vector and covariance matrix. Conclude that increasing the autocorrelation and the number of variables being monitored, reduces the power of the graphics in signal of a special cause