748 resultados para hybrid glasses
Resumo:
An interferometric technique was used to determine the temperature coefficient of the optical path length (dS/dT) as a function of the temperature in several optical glasses. The temperature range was between 25degreesC and 180degreesC. The studied samples included undoped and doped oxide glasses, such as low silica calcium aluminosilicate, phosphates, borates and also chalcogenides. The oxide glasses had dS/dT between 10 X 10(-6) K-1 and 20x10(-6) K-1, while for the chalcogenides, these were around 70 x 10(-6)K(-1). The results showed that dS/dTs increased with the temperature in all samples. For samples doped with Nd the dS/dT values were found to be independent of concentration. on the other hand, for the phosphate glass doped with Cr, dS/dT increased about 5% when compared with the Nd doped one. In conclusion, the used interferometric method, which is a considerably simpler and a lower cost technique, and is a useful tool to measure dS/dT in semi-transparent glasses as a function of the composition and temperature. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Potassium aluminum phosphate (KAP) glasses in the system xKPO(3)-(100-x)AI(PO3)3 with x = 10, 30 and 50 mol% were prepared in the metaphosphate composition. The glasses were doped with MnO2 and their thermoluminescent (TL) response was investigated. Raman spectra showed that these glasses did not undergo structural changes with the substitution of manganese ions. The glass composition x = 50 mol% doped with 1.0 mol% of MnO2 presented the best TL response. The material displayed good sensitivity for gamma-rays, X-rays and UV light. The emission curves exhibited two TL peaks, one at a low temperature (similar to 150 degrees C) and the other at a high temperature (similar to 365 degrees C), whose positions were dependent on the type of exciting radiation applied. The results of the present study indicated that the high temperature peak is a good candidate for TL dosimetric investigations. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Nucleation process and crystal growth for three samples of the (20-x)Li(2)O-80TeO(2)-xWO(3) glass system were studied using X-ray diffraction and differential scanning calorimetry techniques. X-ray diffraction data confirmed the amorphous characteristic of the as-quenched samples and indicated the growth of crystalline phases formed due to the thermal treatment for annealed samples. These results reveal the presence of three distinct gamma-TeO(2), alpha-TeO(2) and alpha-Li(2)Te(2)O(5) crystalline phases in the TL sample, and two distinct alpha-TeO(2) and gamma-TeO(2) crystalline phases in the TLW5 and TLW10 samples. The activation energy and the Avrami exponent were determined from DSC measurements. The activation energy values X-ray diffraction data of the TLW10 glass sample suggest that gamma-TeO(2) phase occur before the alpha-TeO(2). The results obtained for the Avrami exponent point to that the nucleation process is volumetric and that the crystal growth is two or three-dimensional.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs.Methods: Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed before surgery and at 30, 60, 90, 120, 180 and 360 days post-operation.Results: Excellent weight bearing was noticed in the operated limb in seven dogs. Dislocation followed by loosening of the prosthesis was noticed in two dogs, which were therefore properly treated with a femoral head osteotomy. Femoral fracture occurred in one dog, which was promptly treated with full implant removal and femoral osteosynthesis.Conclusions: The canine modular hybrid total hip arthroplasty provided excellent functionality of the operated limb.
Resumo:
Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.
Resumo:
Purpose: the purpose of the present study was to evaluate the histologic results of bone cavities that were surgically created in the mandibles of Cebus apella monkeys and filled with autogenous bone, PerioGlas, FillerBone, or Bone Source. Materials and Methods: Surgical cavities 5 mm in diameter were prepared through both mandibular cortices in the mandibular angle region. The cavities were randomly filled, and the animals were divided into groups according to the material employed: Group 1 cavities were filled with autogenous corticocancellous bone; group 2 cavities were filled with calcium phosphate cement (BoneSource); and group 3 and group 4 cavities were filled with bioactive glass (FillerBone and PerioGlas, respectively). After 180 days the animals were sacrificed, and specimens were prepared following routine laboratory procedures for hematoxylin/eosin staining and histologic evaluation. Results: the histologic analysis showed that autogenous bone allowed total repair of the bone defects; bioactive glasses (FillerBone and PerioGlas) allowed total repair of the defects with intimate contact of the remaining granules and newly formed bone; and the cavities filled with calcium phosphate cement (BoneSource) were generally filled by connective fibrous tissue, and the material was almost totally resorbed. Discussion: the autogenous bone, FillerBone, and PerioGlas provided results similar to those in the current literature, showing that autogenous bone is the best Choice for filling critical-size defects. Synthetic implanted materials demonstrated biocompatibility, but the bioglasses demonstrated osteoconductive activity that did not occur with calcium phosphate (BoneSource). Conclusion: According to the methodology used in this study, it can be concluded that the utilization of autogenous bone and bioactive glasses permitted the repair of surgically created critical-size defects by newly formed bone; the synthetic implanted materials demonstrated biocompatibility, and the bioactive glasses demonstrated osteoconductive activity. The PerioGlas was mostly resorbed and replaced by bone and the remaining granules were in close contact with bone; the FillerBone showed many granules in contact with the newly formed bone; BoneSource did not permit repair of the critical-size defects, and the defects were generally filled by connective fibrous tissue.
Resumo:
The cleaning capacity of hybrid and rotary instrumentation techniques in mesial flattened canals of mandibular first molars was evaluated by morphometrical analysis in this study. Twenty human mandibular first molars were randomly assigned into two groups, according to instrumentation technique, as follows: group 1, instrumentation with ProTaper Starter Kit (Dentsply/Maillefer) rotary system; group 2, manual instrumentation using K files (Dentsply/Maillefer) by crown-down technique in middle and apical thirds, cervical preparation with Gates-Glidden #1 and #2 (Dentsply/Maillefer) burs, and to finalise the preparation, ProTaper F2 and F3 rotary files. Serial transverse cross-sections (5 mu m) of the apical third, stained with hematoxylin and eosin, were analysed at 100 x original magnification. The images were submitted to morphometrical analysis with an integration grid to determine the percentage of root canal area with debris. Statiscal analysis (t-Student, P < 0.05) showed significant difference between the techniques (P < 0.05), although neither completely cleaned the root canal.
Resumo:
Entre as maiores aplicações da cultura de tecidos de plantas está a propagação massal de mudas de plantas ornamentais. O objetivo deste trabalho foi avaliar o cultivo in vitro de um híbrido de orquídea Brassocattleya em diferentes concentrações de NH4NO3, KNO3 e BAP. Foram utilizadas sementes do híbrido de orquídea Brassocattleya 'Pastoral' e as plantas foram cultivadas em meio MS com redução pela metade das fontes de P, Mg e Ca e adição de 25 g L-1 de sacarose, 100 mg L-1 de mio-inositol, 1,5 g L-1 de carvão ativo e 6,5 g L-1 de ágar-ágar, sendo o pH ajustado para 5,8. Como tratamentos foram usados quatro concentrações dos sais NH4NO3 e KNO3 (2x; 1x; ½ e ¼ do meio MS) e três concentrações de BAP (0,0; 0,5 e 1,0 mg L-1). Avaliou-se a multiplicação, o crescimento em altura, massa fresca e seca, além dos teores de açucares redutores na massa seca das mudas. Observou-se grande influência das doses de NH4NO3 e KNO3 sobre o crescimento em altura das mudas, massa fresca e seca e teores de açucares redutores em Bc. ('Pastoral' x Auto). A dose de ¼ da utilizada no meio MS promoveu aumento significativo do crescimento das plantas. Para multiplicação, houve melhor resultado com a dose de ½ dos sais NH4NO3 e KNO3 utilizados no meio MS e 1,0 mg L-1 de BAP.
Resumo:
No presente trabalho foi avaliada a influência do ácido giberélico e do regime hídrico na indução e qualidade do florescimento de duas orquídeas híbridas dos gêneros Cattleya (C.) e Brassocattleya (Bc.). O experimento foi realizado no Setor de Biotecnologia e Orquidicultura da Fundação Shunji Nishimura de Tecnologia, Pompéia-SP. Foram testadas cinco concentrações de GA3 (0, 125, 250, 500 e 1.000 mg L-1) em quatro aplicações consecutivas via pulverização foliar, em plantas adultas que já haviam florescido ao menos uma vez, além de duas condições hídricas (uma e quatro irrigações por semana). As aplicações foram feitas nos meses de outubro e novembro para Bc. Marcella Koss e janeiro e fevereiro para C. Irene Holguin. Não foi possível induzir a floração em Cattleya Irene Holguin com o uso de ácido giberélico. Para Bc. Marcella Koss, a aplicação de 250 mg L-1 de GA3, associado à diminuição na frequência de irrigação, induziu cerca de 83% das plantas ao florescimento. Na mesma concentração de GA3, porém em condições de irrigação frequente, apenas 17% das plantas foram induzidas a florescer. O número e o tamanho das flores aumentaram com a aplicação de concentrações maiores de GA3 utilizadas no experimento. A realização deste trabalho permitiu desenvolver uma técnica comercial com o uso de ácido giberélico (GA3) para a indução do florescimento do híbrido de orquídea Bc. Marcella Koss.
Resumo:
O setor de floricultura movimenta cerca de um bilhão de dólares no Brasil e o desenvolvimento de técnicas direcionadas ao controle do florescimento é necessário. O presente trabalho avaliou a influência do ácido giberélico (GA3) no desenvolvimento vegetativo e reprodutivo de plantas jovens de Phalaenopsis FSNT 'Dai-Itigo', híbrido de coloração rósea. A aplicação do GA3 foi feita via pulverização foliar nas concentrações de 0, 125, 250, 500 e 1.000 mg L -1. O comprimento das folhas aumentou consideravelmente com o uso do GA3 em baixas concentrações, porém houve diminuição da largura foliar das plantas tratadas com esse fitorregulador. A aplicação do GA3 na concentração de 125 mg L -1 apresentou os melhores resultados para a promoção do florescimento e qualidade da floração deste híbrido de orquídea. Nesse tratamento, aproximadamente 50% das plantas pulverizadas apresentaram floração cerca de 6-12 meses antes da floração das plantas sem aplicação do fitorregulador. em conclusão, a qualidade da floração e das flores foi melhor no tratamento com 125 mg L -1 de GA3.