934 resultados para high performance pilots


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cell culture of Maytenus ilicifolia were established in order to produce and to quantify the antitumoral and antioxidant quinonemethide triterpenes. In vitro calli were induced from leaf explants of native plants and cultured in semi-solid medium under controlled conditions of humidity, temperature and photoperiod. The quinonemethide triterpenes showed maximum accumulation in the logarithmic phase growth of the cell culture. A rapid, sensitive and reliable reverse-phase HPLC method was used for quantitative determination of the antitumoral and antioxidant quinonemethide triterpenes, 22β-hydroxymaytenin and maytenin in callus of Maytenus ilicifolia. Well resolved peaks with good detection response and linearity in the range 1.0 - 100 μg/mL were obtained. This quantitative work was performed by an external standard method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flutamide is a potent antiandrogen used for the treatment of prostatic cancer. A simple, sensitive and accurate high-performance liquid Chromatographic (HPLC) method is presented for quantitative determination of flutamide in tablets, using a reversed-phase technique and UV detection at 240 nm. The isocratic elution was used to quantify the analyte. The samples were chromatographed on Luna-C18 column and the mobile phase was 0.05 M phosphate buffer pH 4.0 - acetonitrile (50:50, v/v). The method was linear between 2.9 - 11.6 mg L -1. Over the tested concentration range the intra-day relative standard deviation for replicate analysis in tablets ranged from 0.44 to 0.78%. It was also found that the excipients in the commercial tablets did not interfere with the method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A specific and sensitive high-performance liquid chromatographic method was developed for the assay of praziquantel in raw materials and tablets. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay in the wavelenght selected. The method validation yielded good results and included the range, linearity, precision, accuracy, specificity and recovery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enantiomeric aglycone lignans contained in a mixture were separated from a fraction of the extract of the stems of Alibertia sessilis (Vell.) K. Schum. (Rubiaceae) by preparative high-performance liquid chromatography. An efficient and fast separation can be achieved with methanol-water (30:70, v/v). Their structures were identified as (+)-lyoniresinol 3α-O-β-glucopyranoside and (-)-lyoniresinol 3α-O-β-glucopyranoside, being reported for the first time in Rubiaceae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes an analytical method using high-performance liquid chromatographic (HPLC) separationcoupled with electrochemical detection to detect three dyes, Solvent Blue 14 (SB-14), Solvent Blue 35 (SB-35) andSolvent Red 24 (SR-24). The dyes were eluted and separated using a reversed-phase column (C-8) under isocraticelution with the mobile phase containing a mixture of acetonitrile/ammonium acetate (5.0 mmol L1) at the ratio of75: 25 (v/v). Two sample pretreatment methods were tested and successfully applied to quantify SB14, SB-35 and SR-24 dyes in gasoline samples. The proposed method was simple, fast and suitable to detect and quantify marker dyes ingasoline sample at low concentration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A glassy carbon electrode chemically modified with nickel nanoparticles coupled with reversed-phase chromatography with pulsed amperometric detection was used for the quantitative analysis of furanic aldehydes in a real sample of sugarcane bagasse hydrolysate. Chromatographic separation was carried out in isocratic conditions (acetonitrile/water, 1:9) with a flow rate of 1.0 mL/min, a detection potential of -50 mV vs. Pd, and the process was completed within 4 min. The analytical curves presented limits of detection of 4.0 × 10(-7) mol/L and 4.3 × 10(-7) mol/L, limits of quantification of 1.3 × 10(-6) and 1.4 × 10(-6) mol/L, amperometric sensitivities of 2.2 × 10(6) nA mol/L and 2.7 × 10(6) nA mol/L for furfural and 5-hydroxymethylfurfural, respectively. The values obtained in this sample by the standard addition method were 1.54 ± 0.02 g/kg for 5-hydroxymethylfurfural and 11.5 ± 0.2 g/kg for furfural. The results demonstrate that this new proposed method can be used for the quick detection of furanic aldehydes without the interference of other electroactive species, besides having other remarkable merits that include excellent peak resolution, analytical repeatability, sensitivity, and accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A stability-indication high performance liquid chromatographic method has been developed for the determination of norfloxacin in tablet dosage forms. Optimum separation was achieved in less than 7 minutes using Eclipse Plus Zorbax C18 Agilent, 150 mm×4.6 mm i.d., 5 μm particle size column. The analyte was resolved by using a mobile phase 5% acetic acid aqueous solution and methanol (80:20, v/v) at a flow rate 1.0 ml/min on an isocratic high performance liquid chromatographic system at a wavelength of 277 nm. Linearity, system suitability, precision, sensitivity, selectivity, specific, and robustness were established by International Conference Harmonization guidelines. For stress studies the drug was subjected to photolysis, oxidation, acid, alkaline and neutral conditions. The analytical conditions and the solvent developed provided good resolution within a short analysis time and economic advantages. The proposed method not required sophisticated and expensive instrumentation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Improving the charge capacity, electrochemical reversibility and stability of anode materials are main challenges for the development of Ni-based rechargeable batteries and devices. The combination of cobalt, as additive, and electrode material nanostructuration revealed a very promising approach for this purpose. The new alpha-NiCo mixed hydroxide based electrodes exhibited high specific charge/discharge capacity (355-714 C g(-1)) and outstanding structural stability, withstanding up to 700 redox cycles without any significant phase transformation, as confirmed by cyclic voltammetry, electrochemical quartz crystal microbalance and X-ray diffractometry. In short, the nanostructured alpha-NiCo mixed hydroxide materials possess superior electrochemical properties and stability, being strong candidates for application in high performance batteries and devices. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive analytical method for simultaneous determination of anastrozole, bicalutamide, and tamoxifen as well as their synthetic impurities, anastrozole pentamethyl, bicalutamide 3-fluoro-isomer, and tamoxifen e-isomer, was developed and validated by using high performance liquid chromatography (HPLC). The separation was achieved on a Symmetry (R) C-8 column (100 x 4.6 mm i.d., 3.5 mu m) at room temperature (+/- 24 degrees C), with a mobile phase consisting of acetonitrile/water containing 0.18% N,N dimethyloctylamine and pH adjusted to 3.0 with orthophosphoric acid (46.5/53.5, v/v) at a flow rate of 1.0 mL min(-1) within 20 min. The detection was made at a wavelength of 270 nm by using ultraviolet (UV) detector. No interference peaks from excipients and relative retention time indicated the specificity of the method. The calibration curve showed correlation coefficients (r) > 0.99 calculated by linear regression and analysis of variance (ANOVA). The limit of detection (LOD) and limit of quantitation (LOQ), respectively, were 2.2 and 6.7 mu g mL(-1) for anastrozole, 2.61 and 8.72 mu g mL(-1) for bicalutamide, 2.0 and 6.7 mu g mL(-1) for tamoxifen, 0.06 and 0.22 mu g mL(-1) for anastrozole pentamethyl, 0.02 and 0.07 mu g mL(-1) for bicalutamide 3-fluoro-isomer, and 0.002 and 0.007 mu g mL(-1) for tamoxifen e-isomer. Intraday and interday relative standard deviations (RSDs) were <2.0% (drugs) and <10% (degradation products) as well as the comparison between two different analysts, which were calculated by f test. (C) 2012 Elsevier B.V. All rights reserved.