979 resultados para frequency shift keying (FSK) signals


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde: an important industrial compound used in the manufacture of synthetic resins and chemical compounds such as lubricants and adhesives; also applied as a disinfectant, preservative and in cosmetics productions; relevant workplace exposure to FA also occurs in anatomy, pathology and in mortuaries; classified by IARC as carcinogenic to humans (Group 1), based on sufficient evidence in humans and experimental animals; manifold in vitro studies indicated that FA can induce genotoxic effects in proliferating cultured mammalian cells. Aim of the study: to evaluate if years of exposure induced a genotoxic biomarkers increase, namely MN in lymphocytes and buccal cells, in workers occupationally exposed to FA (factory and pathology anatomy laboratory).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Formaldehyde is classified by IARC as carcinogenic to humans (nasopharyngeal cancer). Tobacco smoke has been epidemiologically associated to a higher risk of development of cancer, especially in the oral cavity, larynx and lungs, as these are places of direct contact with many carcinogenic tobacco’s compounds. XRCC3 is involved in homologous recombination repair of cross-links and chromosomal double-strand breaks (Thr241Met polymorphism). The aim of the study is to determine whether there is an in vivo association between genetic polymorphism of the gene XRCC3 and the frequency of genotoxicity biomarkers in subjects exposed or not to formaldehyde and with or without tobacco consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho utiliza uma estrutura pin empilhada, baseada numa liga de siliceto de carbono amorfo hidrogenado (a-Si:H e/ou a-SiC:H), que funciona como filtro óptico na zona visível do espectro electromagnético. Pretende-se utilizar este dispositivo para realizar a demultiplexagem de sinais ópticos e desenvolver um algoritmo que permita fazer o reconhecimento autónomo do sinal transmitido em cada canal. O objectivo desta tese visa implementar um algoritmo que permita o reconhecimento autónomo da informação transmitida por cada canal através da leitura da fotocorrente fornecida pelo dispositivo. O tema deste trabalho resulta das conclusões de trabalhos anteriores, em que este dispositivo e outros de configuração idêntica foram analisados, de forma a explorar a sua utilização na implementação da tecnologia WDM. Neste trabalho foram utilizados três canais de transmissão (Azul – 470 nm, Verde – 525 nm e Vermelho – 626 nm) e vários tipos de radiação de fundo. Foram realizadas medidas da resposta espectral e da resposta temporal da fotocorrente do dispositivo, em diferentes condições experimentais. Variou-se o comprimento de onda do canal e o comprimento de onda do fundo aplicado, mantendo-se constante a intensidade do canal e a frequência de transmissão. Os resultados obtidos permitiram aferir sobre a influência da presença da radiação de fundo e da tensão aplicada ao dispositivo, usando diferentes sequências de dados transmitidos nos vários canais. Verificou-se, que sob polarização inversa, a radiação de fundo vermelho amplifica os valores de fotocorrente do canal azul e a radiação de fundo azul amplifica o canal vermelho e verde. Para polarização directa, apenas a radiação de fundo azul amplifica os valores de fotocorrente do canal vermelho. Enquanto para ambas as polarizações, a radiação de fundo verde, não tem uma grande influência nos restantes canais. Foram implementados dois algoritmos para proceder ao reconhecimento da informação de cada canal. Na primeira abordagem usou-se a informação contida nas medidas de fotocorrente geradas pelo dispositivo sob polarização inversa e directa. Pela comparação das duas medidas desenvolveu-se e testou-se um algoritmo que permite o reconhecimento dos canais individuais. Numa segunda abordagem procedeu-se ao reconhecimento da informação de cada canal mas com aplicação de radiação de fundo, tendo-se usado a informação contida nas medidas de fotocorrente geradas pelo dispositivo sob polarização inversa sem aplicação de radiação de fundo com a informação contida nas medidas de fotocorrente geradas pelo dispositivo sob polarização inversa com aplicação de radiação de fundo. Pela comparação destas duas medidas desenvolveu-se e testou-se o segundo algoritmo que permite o reconhecimento dos canais individuais com base na aplicação de radiação de fundo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present results on the optimization of multilayered a-SiC:H heterostructures for wavelength-division (de) multiplexing applications. The non selective WDM device is a double heterostructure in a glass/ITO/a-SiC:H (p-i-n) /a-SiC:H(-p) /a-Si:H(-i')/a-SiC:H (-n')/ITO configuration. The single or the multiple modulated wavelength channels are passed through the device, and absorbed accordingly to its wavelength, giving rise to a time dependent wavelength electrical field modulation across it. The effect of single or multiple input signals is converted to an electrical signal to regain the information (wavelength, intensity and frequency) of the incoming photogenerated carriers. Here, the (de) multiplexing of the channels is accomplished electronically, not optically. This approach offers advantages in terms of cost since several channels share the same optical components; and the electrical components are typically less expensive than the optical ones. An electrical model gives insight into the device operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify the association between food group consumption frequency and serum lipoprotein levels among adults. METHODS: The observations were made during a cross-sectional survey of a representative sample of men and women over 20 years old living in Cotia county, S. Paulo, Brazil. Data on food frequency consumption, serum lipids, and other covariates were available for 1,045 adults. Multivariate analyses adjusted by age, gender, body mass index, waist-to-hip ratio, educational level, family income, physical activity, smoking, and alcohol consumption were performed. RESULTS: Consumption of processed meat, chicken, red meat, eggs and dairy foods were each positively and significantly correlated with LDL-C, whereas the intake of vegetables and fruits showed an inverse correlation. Daily consumption of processed meat, chicken, red meat, eggs, and dairy foods were associated with 16.6 mg/dl, 14.5 mg/dl, 11.1 mg/dl, 5.8 mg/dl, and 4.6 mg/dl increase in blood LDL-C, respectively. Increases of daily consumption of fruit and vegetables were associated with 5.2 mg/dl and 5.5 mg/dl decreases in LDL-C, respectively. Alcohol beverage consumption showed a significant positive correlation with HDL-C. CONCLUSIONS: Dietary habits in the study population seem to contribute substantially to the variation in blood LDL and HDL concentrations. Substantially CHD risk reduction could be achieved with dietary changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics of tunable wavelength filters based on a-SiC:H multilayered stacked pin cells are studied both theoretically and experimentally. The optical transducers were produced by PECVD and tested for a proper fine tuning of the cyan and yellow fluorescent proteins emission. The active device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures sandwiched between two transparent contacts. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. Cyan and yellow fluorescent input channels were transmitted together, each one with a specific transmission rate and different intensities. The multiplexed optical signal was analyzed by reading out, under positive and negative applied voltages, the generated photocurrents. Results show that the optimized optical transducer has the capability of combining the transient fluorescent signals onto a single output signal without losing any specificity (color and intensity). It acts as a voltage controlled optical filter: when the applied voltages are chosen appropriately the transducer can select separately the cyan and yellow channel emissions (wavelength and frequency) and also to quantify their relative intensities. A theoretical analysis supported by a numerical simulation is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the quality of life, life satisfaction, happiness and demands of work in workers with different work schedules. METHODS: The survey was carried out on professional workers in social care. Some were shiftworkers whose schedule included night shifts (N=311), some were shiftworkers without night shifts (N=207) and some were non-shiftworkers (N=1,210). Surveys were mailed and the response rate was 86%. For the purpose of this study several variables were selected from the Survey: The Quality of Life Profile, which measures importance, satisfaction, control and opportunities in nine domains of life plus measures of happiness, life satisfaction and demands of work. RESULTS: While both groups of shiftworkers, compared to non-shiftworkers, reported needing more physical effort to complete their work, and reported 'being' more physically tired, no differences were found in reports of overall happiness, life satisfaction or total quality of life. However, night-shiftworkers reported greater percentage of time unhappy than the other two groups of workers. In analyses of the quality of life, night-shiftworkers were less satisfied with domains of spiritual 'being' and physical and community 'belonging' than day-shiftworkers and non-shiftworkers. They also reported having fewer opportunities to improve their physical 'being', leisure, and personal growth than the other two groups. CONCLUSIONS: Quality of life in specific domains in night-shiftworkers was rated worse than in other groups of workers. Domain-based quality of life assessment gives more information regarding the particular needs of workers than overall or global measures of well-being.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To examine the effects of the length and timing of nighttime naps on performance and physiological functions, an experimental study was carried out under simulated night shift schedules. METHODS: Six students were recruited for this study that was composed of 5 experiments. Each experiment involved 3 consecutive days with one night shift (22:00-8:00) followed by daytime sleep and night sleep. The experiments had 5 conditions in which the length and timing of naps were manipulated: 0:00-1:00 (E60), 0:00-2:00 (E120), 4:00-5:00 (L60), 4:00-6:00 (L120), and no nap (No-nap). During the night shifts, participants underwent performance tests. A questionnaire on subjective fatigue and a critical flicker fusion frequency test were administered after the performance tests. Heart rate variability and rectal temperature were recorded continuously during the experiments. Polysomnography was also recorded during the nap. RESULTS: Sleep latency was shorter and sleep efficiency was higher in the nap in L60 and L120 than that in E60 and E120. Slow wave sleep in the naps in E120 and L120 was longer than that in E60 and L60. The mean reaction time in L60 became longer after the nap, and faster in E60 and E120. Earlier naps serve to counteract the decrement in performance and physiological functions during night shifts. Performance was somewhat improved by taking a 2-hour nap later in the shift, but deteriorated after a one-hour nap. CONCLUSIONS: Naps in the latter half of the night shift were superior to earlier naps in terms of sleep quality. However performance declined after a 1-hour nap taken later in the night shift due to sleep inertia. This study suggests that appropriate timing of a short nap must be carefully considered, such as a 60-min nap during the night shift.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The study examines the implications for shiftworkers of applying different numbers of teams in the organization of shiftwork. METHODS: The participating operators came from five different companies applying continuous shift rotation systems. The companies shared the same product organization and a common corporate culture belonging to the same multinational company. Each company had a shift system consisting of four, five or six teams, with the proportion of shifts outside day work decreasing as the number of teams increased. Questionnaire and documentary data were used as data sources. RESULTS: Operators in systems with additional teams had more daywork but also more irregular working hours due to both overtime and schedule changes. Operators using six teams used fewer social compensation strategies. Operators in four teams were most satisfied with their work hours. Satisfaction with the time available for various social activities outside work varied inconsistently between the groups. CONCLUSIONS: In rotating systems the application of more teams reduces the number of shifts outside day work. This apparent improvement for shiftworkers was counteracted by a concomitant irregularity produced by greater organizational requirements for flexibility. The balance of this interaction was found to have a critical impact on employees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Contribution to the discussion of the role of participation/consent of employees in working hours regulation. METHODS: Exploratory analysis of conflicts between preferences of employees and ergonomic recommendations in shift scheduling by analysing a large number of participative shift scheduling projects. RESULTS: The analysis showed that very often the pursuit of higher income played the major role in the decision making process of employees and employees preferred working hours in conflict with health and safety principles. CONCLUSIONS: First, the consent of employees or the works council alone does not ensure ergonomically sound schedules. Besides consent, risk assessment procedures seem to be a promising but difficult approach. Secondly, more research is necessary to check the applicability of recommendations under various settings, to support the risk assessment processes and to improve regulatory approaches to working hours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Faz-se nesta dissertação a análise do movimento humano utilizando sinais de ultrassons refletidos pelos diversos membros do corpo humano, designados por assinaturas de ultrassons. Estas assinaturas são confrontadas com os sinais gerados pelo contato dos membros inferiores do ser humano com o chão, recolhidos de forma passiva. O método seguido teve por base o estudo das assinaturas de Doppler e micro-Doppler. Estas assinaturas são obtidas através do processamento dos ecos de ultrassons recolhidos, com recurso à Short-Time Fourier Transform e apresentadas sobre a forma de espectrograma, onde se podem identificar os desvios de frequência causados pelo movimento das diferentes partes do corpo humano. É proposto um algoritmo inovador que, embora possua algumas limitações, é capaz de isolar e extrair de forma automática algumas das curvas e parâmetros característicos dos membros envolvidos no movimento humano. O algoritmo desenvolvido consegue analisar as assinaturas de micro-Doppler do movimento humano, estimando diversos parâmetros tais como o número de passadas realizadas, a cadência da passada, o comprimento da passada, a velocidade a que o ser humano se desloca e a distância percorrida. Por forma a desenvolver, no futuro, um classificador capaz de distinguir entre humanos e outros animais, são também recolhidas e analisadas assinaturas de ultrassons refletidas por dois animais quadrúpedes, um canino e um equídeo. São ainda estudadas as principais características que permitem classificar o tipo de animal que originou a assinatura de ultrassons. Com este estudo mostra-se ser possível a análise de movimento humano por ultrassons, havendo características nas assinaturas recolhidas que permitem a classificação do movimento como humano ou não humano. Do trabalho desenvolvido resultou ainda uma base de dados de assinaturas de ultrassons de humanos e animais que permitirá suportar trabalho de investigação e desenvolvimento futuro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The International Agency for Research on Cancer classified formaldehyde as carcinogenic to humans because there is “sufficient epidemiological evidence that it causes nasopharyngeal cancer in humans”. Genes involved in DNA repair and maintenance of genome integrity are critically involved in protecting against mutations that lead to cancer and/or inherited genetic disease. Association studies have recently provided evidence for a link between DNA repair polymorphisms and micronucleus (MN) induction. We used the cytokinesis-block micronucleus (CBMN assay) in peripheral lymphocytes and MN test in buccal cells to investigate the effects of XRCC3 Thr241Met, ADH5 Val309Ile, and Asp353Glu polymorphisms on the frequency of genotoxicity biomarkers in individuals occupationally exposed to formaldehyde (n = 54) and unexposed workers (n = 82). XRCC3 participates in DNA double-strand break/recombination repair, while ADH5 is an important component of cellular metabolism for the elimination of formaldehyde. Exposed workers had significantly higher frequencies (P < 0.01) than controls for all genotoxicity biomarkers evaluated in this study. Moreover, there were significant associations between XRCC3 genotypes and nuclear buds, namely XRCC3 Met/Met (OR = 3.975, CI 1.053–14.998, P = 0.042) and XRCC3 Thr/Met (OR = 5.632, CI 1.673–18.961, P = 0.005) in comparison with XRCC3 Thr/Thr. ADH5 polymorphisms did not show significant effects. This study highlights the importance of integrating genotoxicity biomarkers and genetic polymorphisms in human biomonitoring studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A replicate evaluation of increased micronucleus (MN) frequencies in peripheral lymphocytes of workers occupationally exposed to formaldehyde (FA) was undertaken to verify the observed effect and to determine scoring variability. May–Grünwald–Giemsa-stained slides were obtained from a previously performed cytokinesis-block micronucleus test (CBMNT) with 56 workers in anatomy and pathology laboratories and 85 controls. The first evaluation by one scorer (scorer 1) had led to a highly significant difference between workers and controls (3.96 vs 0.81 MN per 1000 cells). The slides were coded before re-evaluation and the code was broken after the complete re-evaluation of the study. A total of 1000 binucleated cells (BNC) were analysed per subject and the frequency of MN (in ‰) was determined. Slides were distributed equally and randomly between two scorers, so that the scorers had no knowledge of the exposure status. Scorer 2 (32 exposed, 36 controls) measured increased MN frequencies in exposed workers (9.88 vs 6.81). Statistical analysis with the two-sample Wilcoxon test indicated that this difference was not significant (p = 0.17). Scorer 3 (20 exposed, 46 controls) obtained a similar result, but slightly higher values for the comparison of exposed and controls (19.0 vs 12.89; p = 0.089). Combining the results of the two scorers (13.38 vs 10.22), a significant difference between exposed and controls (p = 0.028) was obtained when the stratified Wilcoxon test with the scorers as strata was applied. Interestingly, the re-evaluation of the slides led to clearly higher MN frequencies for exposed and controls compared with the first evaluation. Bland–Altman plots indicated that the agreement between the measurements of the different scorers was very poor, as shown by mean differences of 5.9 between scorer 1 and scorer 2 and 13.0 between scorer 1 and scorer 3. Calculation of the intra-class correlation coefficient (ICC) revealed that all scorer comparisons in this study were far from acceptable for the reliability of this assay. Possible implications for the use of the CBMNT in human biomonitoring studies are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilayered heterostructures based on embedded a-Si:H and a-SiC:H p-i-n filters are analyzed from differential voltage design perspective using short- and long-pass filters. The transfer functions characteristics are presented. A numerical simulation is presented to explain the filtering properties of the photonic devices. Several monochromatic pulsed lights, separately (input channels) or in a polychromatic mixture (multiplexed signal) at different bit rates, illuminated the device. Steady-state optical bias is superimposed from the front and the back side. Results show that depending on the wavelength of the external background and impinging side, the device acts either as a short- or a long-pass band filter or as a band-stop filter. Particular attention is given to the amplification coefficient weights, which allow to take into account the wavelength background effects when a band or frequency needs to be filtered or the gate switch, in which optical active filter gates are used to select and filter input signals to specific output ports in wavelength division multiplexing (WDM) communication systems. This nonlinearity provides the possibility for selective removal or addition of wavelengths. A truth table of an encoder that performs 8-to-1 MUX function exemplifies the optoelectronic conversion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of a-SiC:H/a-Si:H pinpin photodiodes for optoelectronic applications as a WDM demultiplexer device has been demonstrated useful in optical communications that use the WDM technique to encode multiple signals in the visible light range. This is required in short range optical communication applications, where for costs reasons the link is provided by Plastic Optical Fibers. Characterization of these devices has shown the presence of large photocapacitive effects. By superimposing background illumination to the pulsed channel the device behaves as a filter, producing signal attenuation, or as an amplifier, producing signal gain, depending on the channel/background wavelength combination. We present here results, obtained by numerical simulations, about the internal electric configuration of a-SiC:H/a-Si:H pinpin photodiode. These results address the explanation of the device functioning in the frequency domain to a wavelength tunable photo-capacitance due to the accumulation of space charge localized at the bottom diode that, according to the Shockley-Read-Hall model, it is mainly due to defect trapping. Experimental result about measurement of the photodiode capacitance under different conditions of illumination and applied bias will be also presented. The combination of these analyses permits the description of a wavelength controlled photo-capacitance that combined with the series and parallel resistance of the diodes may result in the explicit definition of cut off frequencies for frequency capacitive filters activated by the light background or an oscillatory resonance of photogenerated carriers between the two diodes. (C) 2013 Elsevier B.V. All rights reserved.