985 resultados para failure rates
Resumo:
Biofilm formation has been pointed as a major concern in different industrial applications, namely on biomedical implants and surgical instruments, which has prompted the development of new strategies for production of efficient antimicrobial surfaces. In this work, nano âgalvanic couples were created to enhance the antibacterial properties of silver, by embedding it into amorphous carbon (a-C) matrix. The developed Ag/a-C nanocomposite coatings, deposited by magnetron sputtering, revealed an outstanding antibacterial activity against S.epidermidis, promoting a total reduction in biofilm formation with no bacteria counts in all dilution. The open circuit potential (OCP) tests in 0.9% NaCl confirmed that a-C shows a positive \OCP\ value, in contrast to Ag coating, thus enhancing the ionization of biocidal Ag+ due to the nano-galvanic couple activation. This result was confirmed by the inductively coupled plasma-optical emission spectroscopy (ICP-OES), which revealed a higher Ag ionization rate in the nanocomposite coating in comparison with the Ag coating. The surface of Ag/a-C and Ag coatings immersed in 0.9% NaCl were monitored by scanning electron microscopy (SEM) over a period of 24 hours, being found that the Ag ionization determined by ICP-OES was accompanied by an Ag nanoparticles coalescence and agglomeration in Ag/a-C coating.
Resumo:
OBJECTIVE: To compare the effects of 3 types of noninvasive respiratory support systems in the treatment of acute pulmonary edema: oxygen therapy (O2), continuous positive airway pressure, and bilevel positive pressure ventilation. METHODS: We studied prospectively 26 patients with acute pulmonary edema, who were randomized into 1 of 3 types of respiratory support groups. Age was 69±7 years. Ten patients were treated with oxygen, 9 with continuous positive airway pressure, and 7 with noninvasive bilevel positive pressure ventilation. All patients received medicamentous therapy according to the Advanced Cardiac Life Support protocol. Our primary aim was to assess the need for orotracheal intubation. We also assessed the following: heart and respiration rates, blood pressure, PaO2, PaCO2, and pH at begining, and at 10 and 60 minutes after starting the protocol. RESULTS: At 10 minutes, the patients in the bilevel positive pressure ventilation group had the highest PaO2 and the lowest respiration rates; the patients in the O2 group had the highest PaCO2 and the lowest pH (p<0.05). Four patients in the O2 group, 3 patients in the continuous positive pressure group, and none in the bilevel positive pressure ventilation group were intubated (p<0.05). CONCLUSION: Noninvasive bilevel positive pressure ventilation was effective in the treatment of acute cardiogenic pulmonary edema, accelerated the recovery of vital signs and blood gas data, and avoided intubation.
Resumo:
We report the case of a 21-year-old male with high-output heart failure due to a femoral arteriovenous fistula caused by a firearm wound. A new balloon expandable stent covered with polytetrafluorethylene was implanted in the artery to occlude the arteriovenous fistula. The fistula was immediately occluded and the artery remained patent. On the following day, the patient felt much better, with no symptoms of heart failure. Additional follow-up is required to assure the usefulness of this less invasive procedure in the treatment of arteriovenous fistulas.
Resumo:
OBJECTIVE: To verify whether the guidelines for the treatment of heart failure have been adopted at a university hospital. The guidelines recommend the following: use of angiotensin-converting enzyme inhibitors for all patients with systolic ventricular dysfunction, use of digitalis and diuretics for symptomatic patients, use of beta-blockers for patients in functional classes II or III, use of spironolactone for patients in functional classes III or IV. METHODS: We analyzed the prescriptions of 199 patients. All these patients had ejection fraction (EF) <=0.50, their ages ranged from 25 to 86 years, and 142 were males. Cardiomyopathy was the most frequent diagnosis: 67 (33.6%) patients had dilated cardiomyopathy, 65 (32.6%) had ischemic cardiomyopathy. RESULTS: Angiotensin-converting enzyme inhibitors were prescribed for 93% of the patients. 71.8% also had a prescription for digitalis, 86.9% for diuretics, 27.6% for spironolactone, 12% for beta-blockers, 37.2% for acetylsalicylic acid, 6.5% for calcium channel antagonists, and 12.5% for anticoagulants. In regard to vasodilators, 71% of the patients were using captopril (85.2mg/day), 20% enalapril (21.4mg/day), 3% hydralazine and nitrates. In 71.8% of the cases, the dosages prescribed were in accordance with those recommended in the large studies. CONCLUSION: Most patients were prescribed the same doses as those recommended in the large studies. Brazilian patients tolerate well the doses recommended in the studies, and that not using these doses may be a consequence of the physician's fear of prescribing them and not of the patient's intolerance.
Resumo:
OBJECTIVE: The biventricular pacing (BVP) approach has good results in the treatment of congestive heart failure (CHF) in patients (pts) with disorders of intraventricular conduction. METHODS: We have applied BVP to 28 pts, with left ventricular pacing using minitoracotomy in 3 pts and the transvenous aproach via coronary sinus in 25 pts. The mean duration of the QRS complexes was 187 ms, in the presence of the left branch block in 22 pts, and right branch block + divisional hemiblock in 6 pts. All pts had been considerated candidates to cardiac transplantation, and were under optimized drug therapy. Sixteen pts were in Functional Class (NYHA) IV, and 12 in class III. The ejection fraction varied from 22 to 46% (average = 34%). The pacing mode employed was biventricular triple-chamber in 22 pts, and bi-ventricular dual-chamber in 6 pts (one with ICD). RESULTS: The pts were followed up for a period that ranged from 10 days to 14 months (mean 5 months). All pts presented clinical improvement after implant, chaging the NYHA Functional Class at the end of follow-up to Class I (9pts), Class II (10 pts) and Class III (6 pts). The initial mean ejection fraction have-raised to 37%. Two pts died suddenly. One patient died due to a pulmonary fungal infection. CONCLUSION: Ventricular resynchronization through BVP, improved significantly the Functional Class and, therefore, the quality of life. Assessments of myocardial function acutely performed do not reflect the clinical improvement observed.
Resumo:
OBJECTIVE: To evaluate the relationship between 24-hour ambulatory arterial blood pressure monitoring and the prognosis of patients with advanced congestive heart failure. METHODS: We studied 38 patients with NYHA functional class IV congestive heart failure, and analyzed left ventricular ejection fraction, diastolic diameter, and ambulatory blood pressure monitoring data. RESULTS: Twelve deaths occurred. Left ventricular ejection fraction (35.2±7.3%) and diastolic diameter (72.2±7.8mm) were not correlated with the survival. The mean 24-hour (SBP24), waking (SBPw), and sleeping (SBPs) systolic pressures of the living patients were higher than those of the deceased patients and were significant for predicting survival. Patients with mean SBP24, SBPv, and SBPs > or = 105mmHg had longer survival (p=0.002, p=0.01 and p=0.0007, respectively). Patients with diastolic blood pressure sleep decrements (dip) and patients with mean blood pressure dip <=6mmHg had longer survival (p=0.04 and p=0.01, respectively). In the multivariate analysis, SBPs was the only variable with an odds ratio of 7.61 (CI: 1.56; 3704) (p=0.01). Patients with mean SBP<105mmHg were 7.6 times more likely to die than those with SBP > or = 105 mmHg CONCLUSION: Ambulatory blood pressure monitoring appears to be a useful method for evaluating patients with congestive heart failure.
Resumo:
PURPOSE: To analyze the influence of biventricular pacing (BP) on clinical behavior, ventricular arrhythmia (VA) prevalence, and left ventricular ejection fraction (LV EF) by gated ventriculography. METHODS: Twenty-four patients with left bundle branch block (LBBB) and NYHA class III and IV underwent pacemaker implantation and were randomized either to the conventional or BP group, all receiving BP after 6 months. RESULTS: Sixteen patients were in NYHA class IV (66.6%) and 8 were in class III (33.4%). After 1-year follow-up, 14 patients were in class II (70%) and 5 were in class III (25%). Two sudden cardiac deaths occurred. A significant reduction in QRS length was found with BP (p=0.006). A significant statistical increase, from a mean of 19.13 ± 5.19% (at baseline) to 25.33 ± 5.90% (with BP) was observed in LVEF Premature ventricular contraction prevalence decreased from a mean of 10,670.00 ± 12,595.39 SD or to a mean of 3,007.00 ± 3,216.63 SD PVC/24 h with BP (p<0.05). Regarding the hospital admission rate over 1 year, we observed a significant reduction from 60. To 16 admissions with BP (p<0.05). CONCLUSION: Patients with LBBB and severe heart failure experienced, with BP, a significant NYHA class and LVEF improvement. A reduction in the hospital admission rate and VA prevalence also occurred.
Resumo:
OBJECTIVE: To report the hemodynamic and functional responses obtained with clinical optimization guided by hemodynamic parameters in patients with severe and refractory heart failure. METHODS: Invasive hemodynamic monitoring using right heart catheterization aimed to reach low filling pressures and peripheral resistance. Frequent adjustments of intravenous diuretics and vasodilators were performed according to the hemodynamic measurements. RESULTS: We assessed 19 patients (age = 48±12 years and ejection fraction = 21±5%) with severe heart failure. The intravenous use of diuretics and vasodilators reduced by 12 mm Hg (relative reduction of 43%) pulmonary artery occlusion pressure (P<0.001), with a concomitant increment of 6 mL per beat in stroke volume (relative increment of 24%, P<0.001). We observed significant associations between pulmonary artery occlusion pressure and mean pulmonary artery pressure (r=0.76; P<0.001) and central venous pressure (r=0.63; P<0.001). After clinical optimization, improvement in functional class occurred (P< 0.001), with a tendency towards improvement in ejection fraction and no impairment to renal function. CONCLUSION: Optimization guided by hemodynamic parameters in patients with refractory heart failure provides a significant improvement in the hemodynamic profile with concomitant improvement in functional class. This study emphasizes that adjustments in blood volume result in imme-diate benefits for patients with severe heart failure.
Resumo:
OBJECTIVE: The 6-minute walk test is an way of assessing exercise capacity and predicting survival in heart failure. The 6-minute walk test was suggested to be similar to that of daily activities. We investigated the effect of motivation during the 6-minute walk test in heart failure. METHODS: We studied 12 males, age 45±12 years, ejection fraction 23±7%, and functional class III. Patients underwent the following tests: maximal cardiopulmonary exercise test on the treadmill (max), cardiopulmonary 6-minute walk test with the walking rhythm maintained between relatively easy and slightly tiring (levels 11 and 13 on the Borg scale) (6EB), and cardiopulmonary 6-minute walk test using the usual recommendations (6RU). The 6EB and 6RU tests were performed on a treadmill with zero inclination and control of the velocity by the patient. RESULTS: The values obtained in the max, 6EB, and 6RU tests were, respectively, as follows: O2 consumption (ml.kg-1.min-1) 15.4±1.8, 9.8±1.9 (60±10%), and 13.3±2.2 (90±10%); heart rate (bpm) 142±12, 110±13 (77±9%), and 126±11 (89±7%); distance walked (m) 733±147, 332±66, and 470±48; and respiratory exchange ratio (R) 1.13±0.06, 0.9±0.06, and 1.06±0.12. Significant differences were observed in the values of the variables cited between the max and 6EB tests, the max and 6RU tests, and the 6EB and 6RU tests (p<0.05). CONCLUSION: Patients, who undergo the cardiopulmonary 6-minute walk test and are motivated to walk as much as they possibly can, usually walk almost to their maximum capacity, which may not correspond to that of their daily activities. The use of the Borg scale during the cardiopulmonary 6-minute walk test seems to better correspond to the metabolic demand of the usual activities in this group of patients.
Resumo:
El presente proyecto se desarrolló en tres universidades argentinas, una chilena y una portuguesa. En las universidades latinoamericanas asisten sujetos de distintas etnias (huarpes, aymarás, wichi, mapuches). Fueron objetivos de la investigación: a) identificar las motivaciones del ingreso a la Universidad y la evolución de sus expectativas (de futuro, de trabajo); b) conocer las representaciones que tienen del valor de la educación como vía de progreso; c) conocer las estrategias institucionales (curriculares, de convivencia, de servicios) para integrarlos y retenerlos. Los hallazgos muestran la baja efectividad de los programas implementados, con altos índices de fracaso y abandono.
Resumo:
OBJECTIVE: Exercise training programs have been proposed as adjuncts to treatment of heart failure. The effects of a 3-month-exercise-training-program with 3 exercise sessions per week were assessed in patients with stable systolic chronic heart failure. METHODS: We studied 24 patients with final left ventricle diastolic diameter of 70±10mm and left ventricular ejection fraction of 37±4%. Mean age was 52±16 years. Twelve patients were assigned to an exercise training group (G1), and 12 patients were assigned to a control group (G2). Patients underwent treadmill testing, before and after exercise training, to assess distance walked, heart rate, systolic blood pressure, and double product. RESULTS: In G2 group, before and after 3 months, we observed, respectively distance walked, 623±553 and 561± 460m (ns); peak heart rate, 142±23 and 146± 33b/min (ns); systolic blood pressure, 154±36 and 164±26 mmHg (ns); and double product, 22211± 6454 and 24293±7373 (ns). In G1 group, before and after exercise, we observed: distance walked, 615±394 and 970± 537m (p<0.003) peak heart rate, 143±24 and 143±29b/min (ns); systolic blood pressure, 136±33 and 133±24 mmHg (ns); and double product, 19907± 7323 and 19115±5776, respectively. Comparing the groups, a significant difference existed regarding the variation in the double product, and in distance walked. CONCLUSION: Exercise training programs in patients with heart failure can bring about an improvement in physical capacity.