731 resultados para effectiveness of methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The motivation for this paper is to present an approach for rating the quality of the parameters in a computer-aided design model for use as optimization variables. Parametric Effectiveness is computed as the ratio of change in performance achieved by perturbing the parameters in the optimum way, to the change in performance that would be achieved by allowing the boundary of the model to move without the constraint on shape change enforced by the CAD parameterization. The approach is applied in this paper to optimization based on adjoint shape sensitivity analyses. The derivation of parametric effectiveness is presented for optimization both with and without the constraint of constant volume. In both cases, the movement of the boundary is normalized with respect to a small root mean squared movement of the boundary. The approach can be used to select an initial search direction in parameter space, or to select sets of model parameters which have the greatest ability to improve model performance. The approach is applied to a number of example 2D and 3D FEA and CFD problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Whilst there are a number of methods available to characterise the cell surface hydrophobicity (CSH) and cell surface charge (CSC) of microorganisms, there is still debate concerning the correlation of results between individual methods. In this study, the techniques of bacterial adherence to hydrocarbons (BATH) and hydrophobic interaction chromatography (HTC) were used to measure CSH. Electrostatic interaction chromatography (ESIC) and zeta potential (ZP) measurements were used to determine CSC. To allow meaningful comparisons between the BATH and HIC tests, between ESIC and ZP and also between CSH and CSC, the buffer systems employed in each test were standardised (phosphate buffered saline, pH 7.3, 0.01 mM). Isolates of Staphylococcus epidermidis derived from microbial biofilm were used as the test organism in this study. The isolates examined exhibited primarily medium to high CSH and a highly negative CSC. Good correlation of CSH measurement was observed between the BATH and HIC tests (r = 0.89). Good correlation was observed between ESIC (anionic exchange column) and ZP measurements. No correlations were observed between isolate CSC and either increased or decreased CSH. It is recommended that whenever comparisons of various methods to determine either CSC or CSH (by partitioning methods), the buffer systems should remain constant throughout to achieve consistency of results.