957 resultados para echo chaining


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Barbiturates are regularly used as an anesthetic for animal experimentation and clinical procedures and are frequently provided with solubilizing compounds, such as ethanol and propylene glycol, which have been reported to affect brain function and, in the case of (1)H NMR experiments, originate undesired resonances in spectra affecting the quantification. As an alternative, thiopental can be administrated without any solubilizing agents. The aim of the study was to investigate the effect of deep thiopental anesthesia on the neurochemical profile consisting of 19 metabolites and on glucose transport kinetics in vivo in rat cortex compared with alpha-chloralose using localized (1)H NMR spectroscopy. Thiopental was devoid of effects on the neurochemical profile, except for the elevated glucose at a given plasma glucose level resulting from thiopental-induced depression of glucose consumption at isoelectrical condition. Over the entire range of plasma glucose levels, steady-state glucose concentrations were increased on average by 48% +/- 8%, implying that an effect of deep thiopental anesthesia on the transport rate relative to cerebral glucose consumption ratio was increased by 47% +/- 8% compared with light alpha-chloralose-anesthetized rats. We conclude that the thiopental-induced isoelectrical condition in rat cortex significantly affected glucose contents by depressing brain metabolism, which remained substantial at isoelectricity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Surface magnetic resonance imaging (MRI) for aortic plaque assessment is limited by the trade-off between penetration depth and signal-to-noise ratio (SNR). For imaging the deep seated aorta, a combined surface and transesophageal MRI (TEMRI) technique was developed 1) to determine the individual contribution of TEMRI and surface coils to the combined signal, 2) to measure the signal improvement of a combined surface and TEMRI over surface MRI, and 3) to assess for reproducibility of plaque dimension analysis. METHODS AND RESULTS: In 24 patients six black blood proton-density/T2-weighted fast-spin echo images were obtained using three surface and one TEMRI coil for SNR measurements. Reproducibility of plaque dimensions (combined surface and TEMRI) was measured in 10 patients. TEMRI contributed 68% of the signal in the aortic arch and descending aorta, whereas the overall signal gain using the combined technique was up to 225%. Plaque volume measurements had an intraclass correlation coefficient of as high as 0.97. CONCLUSION: Plaque volume measurements for the quantification of aortic plaque size are highly reproducible for combined surface and TEMRI. The TEMRI coil contributes considerably to the aortic MR signal. The combined surface and TEMRI approach improves aortic signal significantly as compared to surface coils alone. CONDENSED ABSTRACT: Conventional MRI aortic plaque visualization is limited by the penetration depth of MRI surface coils and may lead to suboptimal image quality with insufficient reproducibility. By combining a transesophageal MRI (TEMRI) with surface MRI coils we enhanced local and overall image SNR for improved image quality and reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Apoptotic arterial wall vascular smooth muscle cell death is known to contribute to plaque vulnerability and rupture. Novel apoptotic markers like apolipoprotein C-I have been implicated in apoptotic human vascular smooth muscle cell death via recruiting a neutral sphingomyelinase (N-SMase)-ceramide pathway. In vivo relevance of these observations in an animal model of plaque rupture has not been shown. METHODS AND RESULTS: Using Watanabe rabbits, we investigated three different groups (group 1, three normal Watanabe rabbits; group 2, six Watanabe rabbits fed with high cholesterol diet for 3 months; group 3, five Watanabe rabbits with similar diet but additional endothelial denudation). We followed progression of atherosclerosis to pharmacologically induced plaque rupture non-invasively using novel 3D magnetic resonance Fast-Field-Echo angiography (TR=7.2, TE=3.6 ms, matrix=512 x 512) and Fast-Spin-Echo vessel wall imaging methods (TR=3 heart beats, TE=10.5 ms, matrix=304 x 304) on 1.5 T MRI. MRI provided excellent image quality with good MRI versus histology vessel wall thickness correlation (r=0.8). In six animals of group 2/3 MRI detected neo-intimal dissection in the abdominal aorta which was accompanied by immuno-histochemical demonstration of concomitant aforementioned novel apoptotic markers, previously implicated in the apoptotic smooth muscle cell death in vitro. CONCLUSIONS: Our studies suggest a potential role for the signal transduction pathway involving apolipoprotein C-I for in vivo apoptosis and atherosclerotic plaque rupture visualized by MRI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. METHODS: Quadratic phase is imparted to the image to spread the signals in k-space (aka phase scrambling). By rewriting the Fourier transform as a convolution operation, a window can be introduced to the convolved chirp function, allowing a low-resolution image to be reconstructed from phase-scrambled data without prominent aliasing. This image (for each RF channel) can be used to derive coil sensitivities to drive existing parallel imaging techniques. As a proof of concept, the quadratic phase was applied by introducing an offset to the x(2) - y(2) shim and the data were reconstructed using adapted versions of the image space-based sensitivity encoding and GeneRalized Autocalibrating Partially Parallel Acquisitions algorithms. RESULTS: The method is demonstrated in a phantom (1 × 2, 1 × 3, and 2 × 2 acceleration) and in vivo (2 × 2 acceleration) using a 3D gradient echo acquisition. CONCLUSION: Phase scrambling can be used to perform parallel imaging acceleration without acquisition of separate coil calibration data, demonstrated here for a 3D-Cartesian trajectory. Further research is required to prove the applicability to other 2D and 3D sampling schemes. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to their relatively small size and central location within the thorax, improvement in signal-to-noise (SNR) is of paramount importance for in vivo coronary vessel wall imaging. Thus, with higher field strengths, coronary vessel wall imaging is likely to benefit from the expected "near linear" proportional gain in SNR. In this study, we demonstrate the feasibility of in vivo human high field (3 T) coronary vessel wall imaging using a free-breathing black blood fast gradient echo technique with respiratory navigator gating and real-time motion correction. With the broader availability of more SNR efficient fast spin echo and spiral techniques, further improvements can be expected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique for coronary vessel wall imaging. We hypothesized that such an approach would allow for in vivo imaging of coronary atherosclerosis. METHODS AND RESULTS: Ten subjects, including 5 healthy adult volunteers (aged 35+/-17 years, range 19 to 56 years) and 5 patients (aged 60+/-4 years, range 56 to 66 years) with x-ray-confirmed coronary artery disease (CAD), were studied with a T2-weighted, dual-inversion, fast spin-echo MR sequence. Multiple adjacent 5-mm cross-sectional images of the proximal right coronary artery were obtained with an in-plane resolution of 0.5x1.0 mm. A right hemidiaphragmatic navigator was used to facilitate free-breathing MR acquisition. Coronary vessel wall images were readily acquired in all subjects. Both coronary vessel wall thickness (1.5+/-0.2 versus 1.0+/-0.2 mm) and wall area (21.2+/-3.1 versus 13.7+/-4.2 mm(2)) were greater in patients with CAD (both P:<0.02 versus healthy adults). CONCLUSIONS: In vivo free-breathing coronary vessel wall and plaque imaging with MR has been successfully implemented in humans. Coronary wall thickness and wall area were significantly greater in patients with angiographic CAD. The presented technique may have potential applications in patients with known or suspected atherosclerotic CAD or for serial evaluation after pharmacological intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present strategies for chemical shift assignments of large proteins by magic-angle spinning solid-state NMR, using the 21-kDa disulfide-bond-forming enzyme DsbA as prototype. Previous studies have demonstrated that complete de novo assignments are possible for proteins up to approximately 17 kDa, and partial assignments have been performed for several larger proteins. Here we show that combinations of isotopic labeling strategies, high field correlation spectroscopy, and three-dimensional (3D) and four-dimensional (4D) backbone correlation experiments yield highly confident assignments for more than 90% of backbone resonances in DsbA. Samples were prepared as nanocrystalline precipitates by a dialysis procedure, resulting in heterogeneous linewidths below 0.2 ppm. Thus, high magnetic fields, selective decoupling pulse sequences, and sparse isotopic labeling all improved spectral resolution. Assignments by amino acid type were facilitated by particular combinations of pulse sequences and isotopic labeling; for example, transferred echo double resonance experiments enhanced sensitivity for Pro and Gly residues; [2-(13)C]glycerol labeling clarified Val, Ile, and Leu assignments; in-phase anti-phase correlation spectra enabled interpretation of otherwise crowded Glx/Asx side-chain regions; and 3D NCACX experiments on [2-(13)C]glycerol samples provided unique sets of aromatic (Phe, Tyr, and Trp) correlations. Together with high-sensitivity CANCOCA 4D experiments and CANCOCX 3D experiments, unambiguous backbone walks could be performed throughout the majority of the sequence. At 189 residues, DsbA represents the largest monomeric unit for which essentially complete solid-state NMR assignments have so far been achieved. These results will facilitate studies of nanocrystalline DsbA structure and dynamics and will enable analysis of its 41-kDa covalent complex with the membrane protein DsbB, for which we demonstrate a high-resolution two-dimensional (13)C-(13)C spectrum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the value of adding axial traction to direct MR arthrography of the shoulder, in terms of subacromial and glenohumeral joint space widths, and coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. MATERIALS AND METHODS: Twenty-one patients investigated by direct MR arthrography of the shoulder were prospectively included. Studies were performed with a 3 Tesla (T) unit and included a three-dimensional isotropic fat-suppressed T1-weighted gradient-recalled echo sequence, without and with axial traction (4 kg). Two radiologists independently measured the width of the subacromial, superior, and inferior glenohumeral joint spaces. They subsequently rated the amount of contrast material around the superior labrum-biceps tendon complex and between glenohumeral cartilage surfaces, using a three-point scale: 0 = no, 1 = partial, 2 = full. RESULTS: Under traction, the subacromial (Δ = 2.0 mm, P = 0.0003), superior (Δ = 0.7 mm, P = 0.0001) and inferior (Δ = 1.4 mm, P = 0.0006) glenohumeral joint space widths were all significantly increased, and both readers noted significantly more contrast material around the superior labrum-biceps tendon complex (P = 0.014), and between the superior (P = 0.001) and inferior (P = 0.025) glenohumeral cartilage surfaces. CONCLUSION: Direct MR arthrography of the shoulder under axial traction increases subacromial and glenohumeral joint space widths, and prompts better coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. J. Magn. Reson. Imaging 2013;37:1228-1233. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proton T1 relaxation times of metabolites in the human brain have not previously been published at 7 T. In this study, T1 values of CH3 and CH2 group of N-acetylaspartate and total creatine as well as nine other brain metabolites were measured in occipital white matter and gray matter at 7 T using an inversion-recovery technique combined with a newly implemented semi-adiabatic spin-echo full-intensity acquired localized spectroscopy sequence (echo time = 12 ms). The mean T1 values of metabolites in occipital white matter and gray matter ranged from 0.9 to 2.2 s. Among them, the T1 of glutathione, scyllo-inositol, taurine, phosphorylethanolamine, and N-acetylaspartylglutamate were determined for the first time in the human brain. Significant differences in T1 between white matter and gray matter were found for water (-28%), total choline (-14%), N-acetylaspartylglutamate (-29%), N-acetylaspartate (+4%), and glutamate (+8%). An increasing trend in T1 was observed when compared with previously reported values of N-acetylaspartate (CH3 ), total creatine (CH3 ), and total choline at 3 T. However, for N-acetylaspartate (CH3 ), total creatine, and total choline, no substantial differences compared to previously reported values at 9.4 T were discernible. The T1 values reported here will be useful for the quantification of metabolites and signal-to-noise optimization in human brain at 7 T. Magn Reson Med 69:931-936, 2013. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The differentiation between benign and malignant focal liver lesions plays an important role in diagnosis of liver disease and therapeutic planning of local or general disease. This differentiation, based on characterization, relies on the observation of the dynamic vascular patterns (DVP) of lesions with respect to adjacent parenchyma, and may be assessed during contrast-enhanced ultrasound imaging after a bolus injection. For instance, hemangiomas (i.e., benign lesions) exhibit hyper-enhanced signatures over time, whereas metastases (i.e., malignant lesions) frequently present hyperenhanced foci during the arterial phase and always become hypo-enhanced afterwards. The objective of this work was to develop a new parametric imaging technique, aimed at mapping the DVP signatures into a single image called a DVP parametric image, conceived as a diagnostic aid tool for characterizing lesion types. The methodology consisted in processing a time sequence of images (DICOM video data) using four consecutive steps: (1) pre-processing combining image motion correction and linearization to derive an echo-power signal, in each pixel, proportional to local contrast agent concentration over time; (2) signal modeling, by means of a curve-fitting optimization, to compute a difference signal in each pixel, as the subtraction of adjacent parenchyma kinetic from the echopower signal; (3) classification of difference signals; and (4) parametric image rendering to represent classified pixels as a support for diagnosis. DVP parametric imaging was the object of a clinical assessment on a total of 146 lesions, imaged using different medical ultrasound systems. The resulting sensitivity and specificity were 97% and 91%, respectively, which compare favorably with scores of 81 to 95% and 80 to 95% reported in medical literature for sensitivity and specificity, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Despite major advances in care of premature infants, survivors exhibit mild cognitive deficits in around 40%. Beside severe intraventricular haemorrhages (IVH) and cystic periventricular leucomalacia (PVL), more subtle patterns such as grade I and II IVH, punctuate WM lesions and diffuse PVL might be linked to the cognitive deficits. Grey matter disease is also recognized to contribute to long-term cognitive impairment.¦OBJECTIVE: We intend to use novel MR techniques to study more precisely the different injury patterns. In particular MP2RAGE (magnetization prepared dual rapid echo gradient) produces high-resolution quantitative T1 relaxation maps. This contrast is known to reflect tissue anomalies such as white matter injury in general and dysmyelination in particular. We also used diffusion tensor imaging, a quantitative technique known to reflect white matter maturation and disease.¦DESIGN/METHODS: All preterm infants born under 30 weeks of GA were included. Serial 3T MR-imaging using a neonatal head-coil at DOL 3, 10 and at term equivalent age (TEA), using DTI and MP2RAGE sequences was performed. MP2RAGE generates a T1 map and allows calculating the relaxation time T1. Multiple measurements were performed for each exam in 12 defined white and grey matter ROIs.¦RESULTS: 16 patients were recruited: mean GA 27 2/7 w (191,2d SD±10,8), mean BW 999g (SD±265). 39 MRIs were realized (12 early: mean 4,83d±1,75, 13 late: mean 18,77d±8,05 and 14 at TEA: 88,91d±8,96). Measures of relaxation time T1 show a gradual and significant decrease over time (for ROI PLIC mean±SD in ms: 2100.53±102,75, 2116,5±41,55 and 1726,42±51,31 and for ROI central WM: 2302,25±79,02, 2315,02±115,02 and 1992,7±96,37 for early, late and TEA MR respectively). These trends are also observed in grey matter area, especially in thalamus. Measurements of ADC values show similar monotonous decrease over time.¦CONCLUSIONS: From these preliminary results, we conclude that quantitative MR imaging in very preterm infants is feasible. On the successive MP2RAGE and DTI sequences, we observe a gradual decrease over time in the described ROIs, representing the progressive maturation of the WM micro-structure and interestingly the same evolution is observed in the grey matter. We speculate that our study will provide normative values for T1map and ADC and might be a predictive factor for favourable or less favourable outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to determine the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography examination of the knee in terms of joint space width and amount of contrast material between the cartilage surfaces. Direct knee MR arthrography was performed in 11 patients on a 3-T MR imaging unit using a T1-weighted isotropic gradient echo sequence in a coronal plane with and without axial traction of 15 kg. Joint space widths were measured at the level of the medial and the lateral femorotibial joint with and without traction. The amount of contrast material in the medial and lateral femorotibial joint was assessed independently by two musculoskeletal radiologists in a semiquantitative manner using three grades ('absence of surface visualization, 'partial surface visualization or 'complete surface visualization'). With traction, joint space width increased significantly at the lateral femorotibial compartment (mean = 0.55 mm, p = 0.0105) and at the medial femorotibial compartment (mean = 0.4 mm, p = 0.0124). There was a trend towards an increased amount of contrast material in the femorotibial compartment with axial traction. Direct MR arthrography of the knee with axial traction showed a slight and significant increase of the width of the femorotibial compartment with a trend towards more contrast material between the articular cartilage surfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The aim of the study was to determine which, and to what extent, haemodynamic parameters contribute to the remodelling of the venous limb of the Brescia-Cimino haemodialysis access. METHODS: The dimensions of the radial artery and the venous limb of the haemodialysis access were measured by an echo-tracking technique. In six ESRD patients undergoing primary arteriovenous fistula (AVF) formation, vessel diameter, wall thickness, blood pressure and blood flow were measured after the operation, and at 1 and 3 months follow-up. The contralateral forearm vessels in their native position served as baseline values for comparison. RESULTS: The diameter of the proximal antecubital vein progressively increased over the study period without reaching significant differences (4430, 5041 and 6620 microm at weeks 1, 4 and 12 respectively), whereas the intima-media thickness remained unchanged. The venous dilatation was associated with a reduction of the mean shear stress that culminated after the operation and progressively returned to normal venous values at 3 months (24.5 vs 10.4 dyne/cm(2), P<0.043). Thus the venous limb of the AVF undergoes eccentric hypertrophy as demonstrated by the increase in wall cross-sectional area (4.42 vs 6.32 mm(2) at week 1 vs week 12, P<0.028). At the time of the operation, the blood pressure in the AVF was 151+/-14/92.4+/-11 mmHg vs 49+/-19/24.5+/-6 mmHg (means+/-SEM) for the radial artery and the venous limb of the vascular access, respectively. One year after the operation the blood pressure in the venous limb had not changed: 42+/-14/25.3+/-7 mmHg (means+/-SEM). Under these conditions, the systolo-diastolic diameter changes observed in the radial artery and the antecubital vein were within a similar range at all time points: 56+/-17 vs 90+/-26 microm (means+/-SEM) at week 12. CONCLUSIONS: The increased circumferential stress resulting from the flow-mediated dilatation rather than the elevation of blood pressure appears to represent the main contributing factor to the eccentric hypertrophy of the venous limb of Brescia-Cimino haemodialysis access.