942 resultados para direct healthcare cost


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of HRM perceptions is a growing interest in the literature, as one of the antecedents of HRM outcomes. Regardless, not only the cognitive aspect of perception is interesting in this field (what you think) but also the affective perspective is of interest (how you feel about it). In this study we propose a scale for assessing satisfaction with the perceptions of the HRM practices. A 24 item Likert-type scale was developed considering literature review, to assess subjects’ satisfaction with Human Resources Practices in a healthcare setting. Talked reflections were held and a survey encompassing all workers from a Hospital was conducted later, with a sample of 922 subjects. Exploratory and Confirmatory Factor Analysis were performed; reliability was tested using Cronbach’s alpha. The scale presents good psychometric properties with alpha values that range from .71 to .91. Exploratory and Confirmatory Factor Analysis demonstrated that the scale presents a very good fit with CFI= 0.94, AGFI= 0.88, and RMSEA= 0.07. The present study represents a first approach in the usage of this scale and despite having a large sample, respondents originate from a single institution. This study presents a pertinent scale towards measuring a seldom explored construct of the worker-organization relationship. The scale is parsimonious and results are promising. There seems to be very little research on how subjects feel about the HRM practices. This construct, very much in line with more recent studies concerning worker perceptions can be especially interesting in the context of the worker-organization relationship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - A prevalência da obesidade não teve alterações significativas em Portugal. Uma vez que os recursos são escassos e é cada vez mais premente distribuí-los de forma racional, torna-se importante conhecer o impacto económico da obesidade para o país e perceber se os custos se alteraram. Objectivo: Actualizar, à luz de evidência mais recente, a estimativa dos custos directos com internamento hospitalar atribuíveis à obesidade, em Portugal, no ano 2008. Metodologia: Foi estimado o custo directo da obesidade, na componente internamento, a partir da metodologia custo da doença, utilizando uma abordagem baseada na prevalência. Os dados da prevalência advém do estudo epidemiológico mais recente em Portugal (14,4%). Os valores de risco relativo utilizados provêm da meta análise epidemiológica mais completa. Foi calculado, a partir destes dados, o risco atribuível populacional (RAP) de cada patologia. Através da base de dados nacional dos episódios de internamento, fez-se uma pesquisa de todos os episódios de internamento relativos às comorbilidades associadas à obesidade e aplicou-se o respectivo RAP. Com base na portaria n.º 839-A/2009 de 31 Julho atribuíramse os custos. Resultados: Os custos directos com a obesidade, na componente internamento, no ano 2008 foram de 85,9 milhões de euros, o que corresponde a 0,92% da despesa total em saúde. Os três maiores contribuintes para esta despesa são as patologias do sistema circulatório e cerebrovascular, a osteoartrite e os episódios relativos ao tratamento da obesidade em si. Conclusões: O impacto económico relativo ao internamento da obesidade diminuiu em Portugal. Este estudo surge então, como ponto de partida para estudar os custos totais com a obesidade e a efectividade das estratégias de prevenção.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A monitorização da qualidade da energia eléctrica tem revelado importância crescente na gestão e caracterização da rede eléctrica. Estudos revelam que os custos directos relacionados com perda de qualidade da energia eléctrica podem representar cerca de 1,5 % do PIB nacional. Para além destes, tem-se adicionalmente os custos indirectos o que se traduz num problema que necessita de minimização. No contexto da minimização dos danos causados pela degradação de energia, são utilizados equipamentos com capacidade de caracterizar a energia eléctrica através da sua monitorização. A utilização destes equipamentos têm subjacente normas de qualidade de energia, que impõem requisitos mínimos de modo a enquadrar e classificar eventos ocorridos na rede eléctrica. Deste modo obtêm-se dados coerentes provenientes de diferentes equipamentos. A monitorização dos parâmetros associados à energia eléctrica é frequentemente realizada através da instalação temporária dos esquipamentos na rede eléctrica, o que resulta numa observação de distúrbios a posteriori da sua ocasião. Esta metodologia não permite detectar o evento eléctrico original mas, quando muito, outros que se espera que sejam semelhantes ao ocorrido. Repare-se, no entanto, que existe um conjunto alargado de eventos que não são repetitivos, constituindo assim uma limitação aquela metodologia. Este trabalho descreve uma alternativa à metodologia de utilização tradicional dos equipamentos. A solução consiste em realizar um analisador de energia que faça parte integrante da instalação e permita a monitorização contínua da rede eléctrica. Este equipamento deve ter um custo suficientemente baixo para que seja justificável nesta utilização alternativa. O analisador de qualidade de energia a desenvolver tem por base o circuito integrado ADE7880, que permite obter um conjunto de parâmetros da qualidade de energia eléctrica de acordo com as normas de energia IEC 61000-4-30 e IEC 61000-4-7. Este analisador permite a recolha contínua de dados específicos da rede eléctrica, e que posteriormente serão armazenados e colocados à disposição do utilizador. Deste modo os dados recolhidos serão apresentados ao utilizador para consulta, de maneira a verificar, de modo continuo a eventual ocorrência das anomalias na rede. Os valores adquiridos podem ainda ser reutilizados vantajosamente para muitas outras finalidades tais como efectuar estudos sobre a optimização energética. O trabalho presentemente desenvolvido decorre de uma utilização alternativa do dispositivo WeSense Energy1 desenvolvido pela equipa da Evoleo Technologies. A presente vertente permite obter parâmetros determinados pelo ADE7880 tais como por exemplo harmónicos, eventos transitórios de tensão e corrente e o desfasamento entre fases, realizando assim uma nova versão do dispositivo, o WeSense Energy2. Adicionalmente este trabalho inclui a visualização remota dos através de uma página web.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, due to the widespread use of computers and the internet, students are trading libraries for the World Wide Web and laboratories with simulation programs. In most courses, simulators are made available to students and can be used to proof theoretical results or to test a developing hardware/product. Although this is an interesting solution: low cost, easy and fast way to perform some courses work, it has indeed major disadvantages. As everything is currently being done with/in a computer, the students are loosing the “feel” of the real values of the magnitudes. For instance in engineering studies, and mainly in the first years, students need to learn electronics, algorithmic, mathematics and physics. All of these areas can use numerical analysis software, simulation software or spreadsheets and in the majority of the cases data used is either simulated or random numbers, but real data could be used instead. For example, if a course uses numerical analysis software and needs a dataset, the students can learn to manipulate arrays. Also, when using the spreadsheets to build graphics, instead of using a random table, students could use a real dataset based, for instance, in the room temperature and its variation across the day. In this work we present a framework which uses a simple interface allowing it to be used by different courses where the computers are the teaching/learning process in order to give a more realistic feeling to students by using real data. A framework is proposed based on a set of low cost sensors for different physical magnitudes, e.g. temperature, light, wind speed, which are connected to a central server, that the students have access with an Ethernet protocol or are connected directly to the student computer/laptop. These sensors use the communication ports available such as: serial ports, parallel ports, Ethernet or Universal Serial Bus (USB). Since a central server is used, the students are encouraged to use sensor values results in their different courses and consequently in different types of software such as: numerical analysis tools, spreadsheets or simply inside any programming language when a dataset is needed. In order to do this, small pieces of hardware were developed containing at least one sensor using different types of computer communication. As long as the sensors are attached in a server connected to the internet, these tools can also be shared between different schools. This allows sensors that aren't available in a determined school to be used by getting the values from other places that are sharing them. Another remark is that students in the more advanced years and (theoretically) more know how, can use the courses that have some affinities with electronic development to build new sensor pieces and expand the framework further. The final solution provided is very interesting, low cost, simple to develop, allowing flexibility of resources by using the same materials in several courses bringing real world data into the students computer works.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO:Staphylococcus aureus é um dos principais agentes patogénicos humanos, sendo frequentemente associado a infecções nosocomiais e infecções na comunidade. A prevalência de S. aureus resistentes à meticilina (MRSA) em hospitais portugueses é uma das mais elevadas da Europa e tem sido caracterizada extensivamente; contrariamente, a prevalência e epidemiologia de MRSA na comunidade em Portugal não tem sido devidamente seguida. Com o objectivo de compreender as causas possíveis do aumento na frequência de MRSA num dos maiores hospitais centrais portugueses (HSM) ao longo de 17 anos, isolados de MRSA recolhidos em 1993 (n=54) e 2010 (n=180) de pus, sangue e urina foram analisados por PFGE, MLST, tipagem do spa e tipagem de SCCmec. Os resultados mostraram que ocorreu uma mudança global nos tipos clonais predominantes, onde o clone ST22-IVh substituiu os clones, ST239-IIIvar e ST247-I, representando mais de 70% da população actual. Além disso, entre 1993 e 2010 verificou-se um aumento na diversidade genética dos tipos clonais de MRSA. Para determinar a frequência e a natureza clonal de MRSA e S. aureus sensíveis à meticilina (MSSA) isolados de infecções de pele e tecidos moles (SSTI) em pessoas que frequentam centros de saúde em Portugal, 73 amostras foram recolhidas em nove centros de saúde (Rede Médicos Sentinela). Isolou-se um total de 40 S. aureus (55%), dos quais 17,5% eram MRSA. Os isolados de MRSA pertenciam aos clones ST22-IVh (n=4), ST5-IVc (n=2) e ST105-II (n=1), que foram descritos neste estudo como sendo clones de origem hospitalar. Os nossos resultados sugerem que o aumento da frequência de MRSA no HSM pode estar associado à emergência de um clone de MRSA com maior capacidade epidémica. Além disso, verificámos que a principal causa de SSTI em pessoas que frequentam centros de saúde em Portugal são MRSA de origem hospitalar e não MRSA associados à comunidade.------ABSTRACT: Staphylococcus aureus is one of the most important human pathogens, being a major cause of infections worldwide both in the hospital and in the community. In Portugal, the prevalence of methicillin resistant S. aureus (MRSA) in hospitals is one of the highest in Europe and has been characterized extensively; contrarily the prevalence and epidemiology of MRSA in the community has not been followed in a meaningful way. To understand the epidemiological events that could explain a steep increase in MRSA frequency in a major Portuguese central hospital (HSM) within a 17 year period, two MRSA collections recovered in 1993 (n=54) and 2010 (n=180) from pus, blood and urine were analyzed by PFGE, MLST, spa and SCCmec typing. The results showed that a major clonal shift occurred, wherein ST22-IVh clone has replaced the previous ST239-IIIvar and ST247-I clones and accounts for more than 70% of the present population. Moreover, an increase in genetic diversity of MRSA clonal types was observed between the two study periods. With the aim of determining the frequency and clonal nature of MRSA and methicillin-susceptible S. aureus (MSSA) causing skin and soft tissue infections (SSTI) in patients attending healthcare centers in Portugal, 73 samples were collected from nine healthcare centers (Medicos Sentinela Network). A total of 40 S. aureus were isolated, accounting for 55% of the SSTI, of which 17.5% were MRSA. MRSA isolates belonged to ST22-IVh (n=4), ST5-IVc (n=2) and ST105-II (n=1) that have also been described in the hospital in an equivalent period. Our results suggest that the increase in MRSA frequency in HSM may be associated to the emergence of a MRSA clone with higher epidemic potential. Moreover, we propose that the spillover of MRSA from the hospital rather than community-associated-MRSA was the main cause of SSTI in persons attending healthcare centers in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a low cost RTK-GPS system for localization of unmanned surface vehicles. The system is based on the use of standard low cost L1 band receivers and in the RTKlib open source software library. Mission scenarios with multiple robotic vehicles are addressed as the ones envisioned in the ICARUS search and rescue case where the possibility of having a moving RTK base on a large USV and multiple smaller vehicles acting as rovers in a local communication network allows for local relative localization with high quality. The approach is validated in operational conditions with results presented for moving base scenario. The system was implemented in the SWIFT USV with the ROAZ autonomous surface vehicle acting as a moving base. This setup allows for the performing of a missions in a wider range of environments and applications such as precise 3D environment modeling in contained areas and multiple robot operations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 316 samples of nasopharyngeal aspirate from infants up to two years of age with acute respiratory-tract illnesses were processed for detection of respiratory syncytial virus (RSV) using three different techniques: viral isolation, direct immunofluorescence, and PCR. Of the samples, 36 (11.4%) were positive for RSV, considering the three techniques. PCR was the most sensitive technique, providing positive findings in 35/316 (11.1%) of the samples, followed by direct immunofluorescence (25/316, 7.9%) and viral isolation (20/315, 6.3%) (p < 0.001). A sample was positive by immunofluorescence and negative by PCR, and 11 (31.4%) were positive only by RT-PCR. We conclude that RT-PCR is more sensitive than IF and viral isolation to detect RSV in nasopharyngeal aspirate specimens in newborn and infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Health promotion in hospital environments can be improved using the most recent information and communication technologies. The Internet connectivity to small sensor nodes carried by patients allows remote access to their bio-signals. To promote these features the healthcare wireless sensor networks (HWSN) are used. In these networks mobility support is a key issue in order to keep patients under realtime monitoring even when they move around. To keep sensors connected to the network, they should change their access points of attachment when patients move to a new coverage area along an infirmary. This process, called handover, is responsible for continuous network connectivity to the sensors. This paper presents a detailed performance evaluation study considering three handover mechanisms for healthcare scenarios (Hand4MAC, RSSI-based, and Backbone-based). The study was performed by simulation using several scenarios with different number of sensors and different moving velocities of sensor nodes. The results show that Hand4MAC is the best solution to guarantee almost continuous connectivity to sensor nodes with less energy consumption.