967 resultados para detectors
Resumo:
Observing high-energy gamma-rays from Active Galactic Nuclei (AGN) offers a unique potential to probe extremely tiny values of the intergalactic magnetic field (IGMF), a long standing question of astrophysics, astropa rticle physics and cosmology. Very high energy (VHE) photons from blazars propagating along the line of sight interact with the extragalactic background light (EBL) and produce e + e − pairs. Through inverse-Compton interaction, mainly on the cosmic microwave background (CMB), these pairs generate secondary GeV-TeV compo- nents accompanying the primary VHE signal. Such secondary components would be detected in the gamma-ray range as delayed “pair echos” for very weak IGMF ( B< 10 − 16 G ), while they should result in a spatially extended ga mma-ray emission around the source for higher IGMF values ( B> 10 − 16 G ). Coordinated observations with space (i.e. Fermi) and ground- based gamma-ray instruments, such as the pre sent Cherenkov experiments H.E.S.S., MAGIC and VERITAS, the future Cherenkov Telescope Array (CTA) Observatory, and the wide-field detectors such as HAWC and LHAASO, should allow to analyze and finally detect such echos, extended emission or pair halos, and to further characterize the IGMF.
Resumo:
The Space Telescope Imaging Spectrograph (STIS) has been on orbit for approximately 16 years as one of the 2nd generation instruments on the Hubble Space Telescope (HST). Its operations were interrupted by an electronics failure in 2004, but STIS was successfully repaired in May 2009 during Service Mission 4 (SM4) allowing it to resume science observations. The Instrument team continues to monitor its performance and work towards improving the quality of its products. Here we present updated information on the status of the FUV and NUV MAMA and the CCD detectors onboard STIS and describe recent changes to the STIS calibration pipeline. We also discuss the status of efforts to apply a pixel-based correction for charge transfer inefficiency (CTI) effects to STIS CCD data. These techniques show promise for ameliorating the effects of ongoing radiation damage on the quality of STIS CCD data.
Resumo:
Doppler Broadening Spectroscopy of the large Ge crystal of an HPGe detector was perforrned using positrons from pair production of 6.13 MeV ϒ-rays from the 19F(p,αϒ) 16O reaction. Two HPGe detectors facing opposite sides of the Ge crystal acting as target provided both coincidence and singles spectra. Changes in the shape of the annihilation peak were observed when the high voltage applied to the target detector was switched on or off, amounting to somewhat less than 20% when the areas of equivalent energy intervals in the corresponding normalized spectra are compared.
Resumo:
The energetic stability and the electronic properties of vacancies (VX) and antisites (XY) in PbSe and PbTe are investigated. PbSe and PbTe are narrow band gap semiconductors and have the potential to be used in infrared detectors, laser, and diodes. They are also of special interest for thermoelectric devices (TE). The calculations are based in the Density Functional Theory (DFT) and the General Gradient Approximation (GGA) for the exchange-correlation term, as implemented in the VASP code. The core and valence electrons are described by the Projected Augmented Wave (PAW) and the Plane Wave (PW) methods, respectively. The defects are studied in the bulk and nanowire (NW) system. Our results show that intrinsec defects (vacancies and antisites) in PbTe have lower formation energies in the NW as compared to the bulk and present a trend in migrate to the surface of the NW. For the PbSe we obtain similar results when compare the formation energy for the bulk and NW. However, the Pb vacancy and the antisites are more stable in the core of the NW. The intrinsec defects are shallow defects for the bulk system. For both PbSe and PbTe VPb is a shallow acceptor defect and VSe and VT e are shallow donor defects for the PbSe and PbTe, respectively. Similar electronic properties are observed for the antisites. For the Pb in the anion site we obtain an n-type semiconductor for both PbSe and PbTe, SeP b is a p-type for the PbSe, and T eP b is a n-type for PbTe. Due the quantum con¯nement effects present in the NW (the band gap open), these defects have different electronic properties for the NW as compared to the bulk. Now these defects give rise to electronic levels in the band gap of the PbTe NW and the VT e present a metallic character. For the PbSe NW a p-type and a n-type semiconductor is obtained for the VP b and P bSe, respectively. On the other hand, deep electronic levels are present in the band gap for the VSe and SePb. These results show that due an enhanced in the electronic density of states (DOS) near the Fermi energy, the defective PbSe and PbTe are candidates for efficient TE devices.
Resumo:
The observation of ultrahigh energy neutrinos (UHE vs) has become a priority in experimental astroparticle physics. UHE vs can be detected with a variety of techniques. In particular, neutrinos can interact in the atmosphere (downward-going v) or in the Earth crust (Earth-skimming v), producing air showers that can be observed with arrays of detectors at the ground. With the surface detector array of the Pierre Auger Observatory we can detect these types of cascades. The distinguishing signature for neutrino events is the presence of very inclined showers produced close to the ground (i.e., after having traversed a large amount of atmosphere). In this work we review the procedure and criteria established to search for UHEs in the data collected with the ground array of the Pierre Auger Observatory.This includes Earth-skimming as well as downward-going neutrinos. No neutrino candidates have been found, which allows us to place competitive limits to the diffuse flux of UHE vs in the EeV range and above.
Resumo:
The nature of the dark matter in the Universe is one of the greatest mysteries in modern astronomy. The neutralino is a nonbaryonic dark matter candidate in minimal supersymmetric extensions to the standard model of particle physics. If the dark matter halo of our galaxy is made up of neutralinos some would become gravitationally trapped inside massive bodies like the Earth. Their pair-wise annihilation produces neutrinos that can be detected by neutrino experiments looking in the direction of the centre of the Earth. The AMANDA neutrino telescope, currently the largest in the world, consists of an array of light detectors buried deep in the Antarctic glacier at the geographical South Pole. The extremely transparent ice acts as a Cherenkov medium for muons passing the array and using the timing information of detected photons it is possible to reconstruct the muon direction. A search has been performed for nearly vertically upgoing neutrino induced muons with AMANDA-B10 data taken over the three year period 1997-99. No excess above the atmospheric neutrino background expectation was found. Upper limits at the 90 % confidence level has been set on the annihilation rate of neutralinos at the centre of the Earth and on the muon flux induced by neutrinos created by the annihilation products.
Resumo:
[ES] Este Trabajo de Fin de Grado describe el desarrollo de un prototipo para plataformas móviles, que permite determinar si un pez alcanza la talla mínima establecida para su consumo. Para ello se realiza la detección y segmentación de un pez, para posteriormente determinar si cumple con la talla mínima, utilizando como referencia una moneda de un euro para calibrar el tamaño. La detección se realiza aplicando la implementación del esquema de Viola-Jones, integrada en la librería OpenCV, creando una serie de detectores propios tanto para los peces como para la moneda. Asimismo se ha utilizado SDK del que dispone dicha librería para desarrollar la aplicación en plataforma móvil Android.
Resumo:
[EN]OpenCV includes di erent object detectors based on the Viola-Jones framework. Most of them are specialized to deal with the frontal face pattern and its inner elements: eyes, nose, and mouth. In this paper, we focus on the ear pattern detection, particularly when a head pro le or almost pro le view is present in the image. We aim at creating real-time ear detectors based on the general object detection framework provided with OpenCV. After training classi ers to detect left ears, right ears, and ears in general, the performance achieved is valid to be used to feed not only a head pose estimation system but also other applications such as those based on ear biometrics.
Resumo:
[EN] This paper analyzes the detection and localization performance of the participating face and eye algorithms compared with the Viola Jones detector and four leading commercial face detectors. Performance is characterized under the different conditions and parameterized by per-image brightness and contrast. In localization accuracy for eyes, the groups/companies focusing on long-range face detection outperform leading commercial applications.
Resumo:
During recent years a consistent number of central nervous system (CNS) drugs have been approved and introduced on the market for the treatment of many psychiatric and neurological disorders, including psychosis, depression, Parkinson disease and epilepsy. Despite the great advancements obtained in the treatment of CNS diseases/disorders, partial response to therapy or treatment failure are frequent, at least in part due to poor compliance, but also genetic variability in the metabolism of psychotropic agents or polypharmacy, which may lead to sub-therapeutic or toxic plasma levels of the drugs, and finally inefficacy of the treatment or adverse/toxic effects. With the aim of improving the treatment, reducing toxic/side effects and patient hospitalisation, Therapeutic Drug Monitoring (TDM) is certainly useful, allowing for a personalisation of the therapy. Reliable analytical methods are required to determine the plasma levels of psychotropic drugs, which are often present at low concentrations (tens or hundreds of nanograms per millilitre). The present PhD Thesis has focused on the development of analytical methods for the determination of CNS drugs in biological fluids, including antidepressants (sertraline and duloxetine), antipsychotics (aripiprazole), antiepileptics (vigabatrin and topiramate) and antiparkinsons (pramipexole). Innovative methods based on liquid chromatography or capillary electrophoresis coupled to diode-array or laser-induced fluorescence detectors have been developed, together with the suitable sample pre-treatment for interference removal and fluorescent labelling in case of LIF detection. All methods have been validated according to official guidelines and applied to the analysis of real samples obtained from patients, resulting suitable for the TDM of psychotropic drugs.
Resumo:
ALICE, that is an experiment held at CERN using the LHC, is specialized in analyzing lead-ion collisions. ALICE will study the properties of quarkgluon plasma, a state of matter where quarks and gluons, under conditions of very high temperatures and densities, are no longer confined inside hadrons. Such a state of matter probably existed just after the Big Bang, before particles such as protons and neutrons were formed. The SDD detector, one of the ALICE subdetectors, is part of the ITS that is composed by 6 cylindrical layers with the innermost one attached to the beam pipe. The ITS tracks and identifies particles near the interaction point, it also aligns the tracks of the articles detected by more external detectors. The two ITS middle layers contain the whole 260 SDD detectors. A multichannel readout board, called CARLOSrx, receives at the same time the data coming from 12 SDD detectors. In total there are 24 CARLOSrx boards needed to read data coming from all the SDD modules (detector plus front end electronics). CARLOSrx packs data coming from the front end electronics through optical link connections, it stores them in a large data FIFO and then it sends them to the DAQ system. Each CARLOSrx is composed by two boards. One is called CARLOSrx data, that reads data coming from the SDD detectors and configures the FEE; the other one is called CARLOSrx clock, that sends the clock signal to all the FEE. This thesis contains a description of the hardware design and firmware features of both CARLOSrx data and CARLOSrx clock boards, which deal with all the SDD readout chain. A description of the software tools necessary to test and configure the front end electronics will be presented at the end of the thesis.
Resumo:
Several activities were conducted during my PhD activity. For the NEMO experiment a collaboration between the INFN/University groups of Catania and Bologna led to the development and production of a mixed signal acquisition board for the Nemo Km3 telescope. The research concerned the feasibility study for a different acquisition technique quite far from that adopted in the NEMO Phase 1 telescope. The DAQ board that we realized exploits the LIRA06 front-end chip for the analog acquisition of anodic an dynodic sources of a PMT (Photo-Multiplier Tube). The low-power analog acquisition allows to sample contemporaneously multiple channels of the PMT at different gain factors in order to increase the signal response linearity over a wider dynamic range. Also the auto triggering and self-event-classification features help to improve the acquisition performance and the knowledge on the neutrino event. A fully functional interface towards the first level data concentrator, the Floor Control Module, has been integrated as well on the board, and a specific firmware has been realized to comply with the present communication protocols. This stage of the project foresees the use of an FPGA, a high speed configurable device, to provide the board with a flexible digital logic control core. After the validation of the whole front-end architecture this feature would be probably integrated in a common mixed-signal ASIC (Application Specific Integrated Circuit). The volatile nature of the configuration memory of the FPGA implied the integration of a flash ISP (In System Programming) memory and a smart architecture for a safe remote reconfiguration of it. All the integrated features of the board have been tested. At the Catania laboratory the behavior of the LIRA chip has been investigated in the digital environment of the DAQ board and we succeeded in driving the acquisition with the FPGA. The PMT pulses generated with an arbitrary waveform generator were correctly triggered and acquired by the analog chip, and successively they were digitized by the on board ADC under the supervision of the FPGA. For the communication towards the data concentrator a test bench has been realized in Bologna where, thanks to a lending of the Roma University and INFN, a full readout chain equivalent to that present in the NEMO phase-1 was installed. These tests showed a good behavior of the digital electronic that was able to receive and to execute command imparted by the PC console and to answer back with a reply. The remotely configurable logic behaved well too and demonstrated, at least in principle, the validity of this technique. A new prototype board is now under development at the Catania laboratory as an evolution of the one described above. This board is going to be deployed within the NEMO Phase-2 tower in one of its floors dedicated to new front-end proposals. This board will integrate a new analog acquisition chip called SAS (Smart Auto-triggering Sampler) introducing thus a new analog front-end but inheriting most of the digital logic present in the current DAQ board discussed in this thesis. For what concern the activity on high-resolution vertex detectors, I worked within the SLIM5 collaboration for the characterization of a MAPS (Monolithic Active Pixel Sensor) device called APSEL-4D. The mentioned chip is a matrix of 4096 active pixel sensors with deep N-well implantations meant for charge collection and to shield the analog electronics from digital noise. The chip integrates the full-custom sensors matrix and the sparsifification/readout logic realized with standard-cells in STM CMOS technology 130 nm. For the chip characterization a test-beam has been set up on the 12 GeV PS (Proton Synchrotron) line facility at CERN of Geneva (CH). The collaboration prepared a silicon strip telescope and a DAQ system (hardware and software) for data acquisition and control of the telescope that allowed to store about 90 million events in 7 equivalent days of live-time of the beam. My activities concerned basically the realization of a firmware interface towards and from the MAPS chip in order to integrate it on the general DAQ system. Thereafter I worked on the DAQ software to implement on it a proper Slow Control interface of the APSEL4D. Several APSEL4D chips with different thinning have been tested during the test beam. Those with 100 and 300 um presented an overall efficiency of about 90% imparting a threshold of 450 electrons. The test-beam allowed to estimate also the resolution of the pixel sensor providing good results consistent with the pitch/sqrt(12) formula. The MAPS intrinsic resolution has been extracted from the width of the residual plot taking into account the multiple scattering effect.
Resumo:
The OPERA experiment aims at the direct observation of ν_mu -> ν_tau oscillations in the CNGS (CERN Neutrinos to Gran Sasso) neutrino beam produced at CERN; since the ν_e contamination in the CNGS beam is low, OPERA will also be able to study the sub-dominant oscillation channel ν_mu -> ν_e. OPERA is a large scale hybrid apparatus divided in two supermodules, each equipped with electronic detectors, an iron spectrometer and a highly segmented ~0.7 kton target section made of Emulsion Cloud Chamber (ECC) units. During my research work in the Bologna Lab. I have taken part to the set-up of the automatic scanning microscopes studying and tuning the scanning system performances and efficiencies with emulsions exposed to a test beam at CERN in 2007. Once the triggered bricks were distributed to the collaboration laboratories, my work was centered on the procedure used for the localization and the reconstruction of neutrino events.
Resumo:
Mycotoxins are heterogeneous chemical compounds characterized by a low molecular weight and synthesized by the secondary metabolism of different molds. Fumonisins are water-soluble mycotoxins produced by Fusarium species spoiling corn and derived produc ts. These mycotoxins can be a health hazard when consuming contaminated cereals, but they can reach humans also indirectly through the consumption of food products derived from animals fed with contaminated feed. Fumonisins have been associated with several animal and human diseases: they are suspected risk factors for esophageal and liver cancers, neural tube defects and cardiovascular problems. Improved methods are needed to accurately assess fumonisins concentrations in food of vegetable and animal origin, in order to prevent acute and chronic human exposure. The aim of the present work was to evaluate the versatility and the performances of mass spectrometry, coupled with liquid chromatography, in fumonisins analysis from foods and matrices of animal origin. Different methods for the identification and quantification of fumonisins and related products have been developed and validated to determine fumonisin B1 in milk, fumonisin B1, fumonisin B2 and their complete hydrolyzed products (HFB1 and HFB2) in pig liver and fumonisins B1 and B2 in complete and complementary dry dog food. The experimental procedures have been carefully studied, considering matrices features, number and type of molecules to detect. Therefore, several extraction, clean up and separation techniques were tested in order to obtain the better conditions of sample processing. The fit for purpose sample preparation, matched with high mass spectrometry sensibility and specificity, have allowed to achieve good results in any tested animal matrices. Hence, the developed methods were validated and have shown a high accuracy, sensibility and precision, fulfilling performance requirements of Decision 2002/657/EC and of European Project Standard, Measuring and Testing (SMT). In any developed method, the analytes were identified and quantified even at very low concentrations : the limits of quantification resulted lower than other similar works, performed with different detectors. These methods were applied to some commercial samples and to some samples collected for research projects in the Department of Veterinary Public Health and Animal Pathology (DVPHAP) of University of Bologna. Although the disclosed data must be considered completely preliminary and without statistical significance, they emphasize the presence of mycotoxins in animal products. The outcomes obtained from the processed samples (bovine milk, pig liver and dry dog food) suggest the efficacy of these methods also on other food matrices, confirming the versatility and the performances of mass spectrometry, coupled with liquid chromatography, in fumonisins analysis. Moreover the results underline the need to set up a large scale monitoring in order to evaluate the presence of fumonisins in food of animal origin for human consumption.
Resumo:
This thesis is about three major aspects of the identification of top quarks. First comes the understanding of their production mechanism, their decay channels and how to translate theoretical formulae into programs that can simulate such physical processes using Monte Carlo techniques. In particular, the author has been involved in the introduction of the POWHEG generator in the framework of the ATLAS experiment. POWHEG is now fully used as the benchmark program for the simulation of ttbar pairs production and decay, along with MC@NLO and AcerMC: this will be shown in chapter one. The second chapter illustrates the ATLAS detectors and its sub-units, such as calorimeters and muon chambers. It is very important to evaluate their efficiency in order to fully understand what happens during the passage of radiation through the detector and to use this knowledge in the calculation of final quantities such as the ttbar production cross section. The last part of this thesis concerns the evaluation of this quantity deploying the so-called "golden channel" of ttbar decays, yielding one energetic charged lepton, four particle jets and a relevant quantity of missing transverse energy due to the neutrino. The most important systematic errors arising from the various part of the calculation are studied in detail. Jet energy scale, trigger efficiency, Monte Carlo models, reconstruction algorithms and luminosity measurement are examples of what can contribute to the uncertainty about the cross-section.