909 resultados para comparison methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: After several years of increasing 'normalisation' of cannabis use in Switzerland at the beginning of the new millennium, a reversed tendency, marked among others by a more stringent law-enforcement, set in. The presentation examines the question of where adolescents and young adults obtained cannabis, within the context of this societal change. In addition, it compares the sources of supply for cannabis with those found in studies of other European countries. Methods: Analyses are based on data from the Swiss Cannabis Monitoring Study. As part of this longitudinal, representative population survey, more than 5000 adolescents and young adults were interviewed by telephone on the topic of cannabis. Within the total sample, 593 (2004) or 554 (2007) respectively, current cannabis users replied to the questions on sources of supply. Changes in law-enforcement and societal climate concerning cannabis are assessed based on relevant literature, media reports and parliamentary discussions. Results: Whereas 22% of cannabis users stated in 2004 that they bought their cannabis from vendors in hemp shops, this proportion drastically decreased to 6% three years later. At the same time, cannabis was obtained increasingly from friends, while the proportion of users who purchased cannabis from dealers in the alleyway, more than doubled from 6% (2004) to 13% (2007). It was male cannabis users, and in particular, young adult and frequent users, who have moved into the alleyways. Generally, users who buy cannabis in the alleyway show more cannabis-related problems than those who mainly name other sources of supply, even when adjusted for sex, age and frequency of cannabis use. Discussion: Possible consequences of these changes in cannabis supply, like the risk of merging a previously cannabis-only market with other 'harder' drugs markets, are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the International Olympic Committee (IOC) accredited laboratories, specific methods have been developed to detect anabolic steroids in athletes' urine. The technique of choice to achieve this is gas-chromatography coupled with mass spectrometry (GC-MS). In order to improve the efficiency of anti-doping programmes, the laboratories have defined new analytical strategies. The final sensitivity of the analytical procedure can be improved by choosing new technologies for use in detection, such as tandem mass spectrometry (MS-MS) or high resolution mass spectrometry (HRMS). A better sample preparation using immuno-affinity chromatography (IAC) is also a good tool for improving sensitivity. These techniques are suitable for the detection of synthetic anabolic steroids whose structure is not found naturally in the human body. The more and more evident use, on a large scale, of substances chemically similar to the endogenous steroids obliges both the laboratory and the sports authorities to use the steroid profile of the athlete in comparison with reference ranges from a population or with intraindividual reference values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Number of larval instars, age structure and environmental effects on these parameters represent basic information in the study of insect population biology. When species have economic importance, this information is essential in order to choose the best period to apply different control methods and to determine the stages of the life cycle of the insect that are most susceptible to each treatment. The family Simuliidae has many species of medical/veterinary importance in the world, and some studies in the temperate region have suggested that the number of larval instars and the larval size can vary according to the season, gender and some environmental factors, such as temperature and diet. This study, with the zoophilic species Simulium perflavum Roubaud, is the first in the Neotropics observing some of these factors and will serve as a template for other species of medical importance in the region. S. perflavum larvae were collected in five streams in Central Amazônia (Manaus and Presidente Figueiredo counties, State of Amazonas), in Sept./Oct. 1996 (dry season) and Feb./Mar. 1997 (rainy season). These larvae were measured (lateral length of head capsule and width of cephalic apodema) to determine the number of larval instars (n=3985), to compare the larval size between seasons and genders (last and penultimate larval instars, n=200). Seven larval instars were determined for this species using frequency distributions, t-tests and Crosby´s growth rule. Significant differences were not detected (t-test, p>0.05) in larval size between seasons and genders. Our results differ from some found in temperate regions suggesting that in the Neotropical region the larval size in different seasons and different genders remains constant, although some environmental parameters, such as diet, change depending on the season.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hepatitis E virus (HEV) is responsible for many enterically transmitted viral hepatitides around the world. It is currently one of the waterborne diseases of global concern. In industrialized countries, HEV appears to be more common than previously thought, even if it is rarely virulent. In Switzerland, seroprevalence studies revealed that HEV is endemic, but no information was available on its environmental spread. The aim of this study was to investigate -using qPCR- the occurrence and concentration of HEV and three other viruses (norovirus genogroup II, human adenovirus-40 and porcine adenovirus) in influents and effluents of 31 wastewater treatment plants (WWTPs) in Switzerland. Low concentrations of HEV were detected in 40 out of 124 WWTP influent samples, showing that HEV is commonly present in this region. The frequency of HEV occurrence was higher in summer than in winter. No HEV was detected in WWTP effluent samples, which indicates a low risk of environmental contamination. HEV occurrence and concentrations were lower than those of norovirus and adenovirus. The autochthonous HEV genotype 3 was found in all positive samples, but a strain of the non-endemic and highly pathogenic HEV genotype I was isolated in one sample, highlighting the possibility of environmental circulation of this genotype. A porcine fecal marker (porcine adenovirus) was not detected in HEV positive samples, indicating that swine are not the direct source of HEV present in wastewater. Further investigations will be necessary to determine the reservoirs and the routes of dissemination of HEV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare three spin-echo sequences, transverse T1-weighted (T1WI), transverse fat-saturated (FS) T2-weighted (T2WI), and transverse gadolinium-enhanced (Gd) FS T1WI, for the visualisation of normal and abnormal finger A2 pulley with magnetic resonance (MR) imaging at 3 tesla (T). MATERIALS AND METHODS: Sixty-three fingers from 21 patients were consecutively investigated. Two musculoskeletal radiologists retrospectively compared all sequences to assess the visibility of normal and abnormal A2 pulleys and the presence of motion or ghost artefacts. RESULTS: Normal and abnormal A2 pulleys were visible in 94% (59/63) and 95% (60/63) on T1WI sequences, in 63% (40/63) and 60% (38/63) on FS T2WI sequences, and in 87% (55/63) and 73% (46/63) on Gd FS T1WI sequences when read by the first and second observer, respectively. Motion and ghost artefacts were higher on FS T2WI sequences. Seven among eight abnormal A2 pulleys were detected, and were best depicted with Gd FS T1WI sequences in 71% (5/7) and 86% (6/7) by the first and the second observer, respectively. CONCLUSION: In 3-T MRI, the comparison between transverse T1WI, FS T2WI, and Gd FS T1WI sequences shows that transverse T1WI allows excellent depiction of the A2 pulley, that FS T2WI suffers from a higher rate of motion and ghost artefacts, and transverse Gd FS T1WI is the best sequence for the depiction of abnormal A2 pulley.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the correlation between proportion method with mycobacteria growth indicator tube (MGIT) and E-test for Mycobacterium tuberculosis. Forty clinical isolates were tested. MGIT and E-test with the first line antituberculous drugs correlated with the proportion method. Our results suggested that MGIT and E-test methods can be routinely used instead of the proportion method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Lesion detection in multiple sclerosis (MS) is an essential part of its clinical diagnosis. In addition, radiological characterisation of MS lesions is an important research field that aims at distinguishing different MS types, monitoring drug response and prognosis. To date, various MR protocols have been proposed to obtain optimal lesion contrast for early and comprehensive diagnosis of the MS disease. In this study, we compare the sensitivity of five different MR contrasts for lesion detection: (i) the DIR sequence (Double Inversion Recovery, [4]), (ii) the Dark-fluid SPACE acquisition schemes, a 3D variant of a 2D FLAIR sequence [1], (iii) the MP2RAGE [2], an MP-RAGE variant that provides homogeneous T1 contrast and quantitative T1-values, and the sequences currently used for clinical MS diagnosis (2D FLAIR, MP-RAGE). Furthermore, we investigate the T1 relaxation times of cortical and sub-cortical regions in the brain hemispheres and the cerebellum at 3T. Methods 10 early-stage female MS patients (age: 31.64.7y; disease duration: 3.81.9y; disability score, EDSS: 1.80.4) and 10 healthy controls (age and gender-matched: 31.25.8y) were included in the study after obtaining informed written consent according to the local ethic protocol. All experiments were performed at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil [5]. The imaging protocol included the following sequences, (all except for axial FLAIR 2D with 1x1x1.2 mm3 voxel and 256x256x160 matrix): DIR (TI1/TI2/TR XX/3652/10000 ms, iPAT=2, TA 12:02 min), MP-RAGE (TI/TR 900/2300 ms, iPAT=3, TA 3:47 min); MP2RAGE (TI1/TI2/TR 700/2500/5000 ms, iPAT=3, TA 8:22 min, cf. [2]); 3D FLAIR SPACE (only for patient 4-6, TI/TR 1800/5000 ms, iPAT=2, TA=5;52 min, cf. [1]); Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix, TI/TR 2500/9000 ms, iPAT=2, TA 4:05 min). Lesions were identified by two experienced neurologist and radiologist, manually contoured and assigned to regional locations (s. table 1). Regional lesion masks (RLM) from each contrast were compared for number and volumes of lesions. In addition, RLM were merged in a single "master" mask, which represented the sum of the lesions of all contrasts. T1 values were derived for each location from this mask for patients 5-10 (3D FLAIR contrast was missing for patient 1-4). Results & Discussion The DIR sequence appears the most sensitive for total lesions count, followed by the MP2RAGE (table 1). The 3D FLAIR SPACE sequence turns out to be more sensitive than the 2D FLAIR, presumably due to reduced partial volume effects. Looking for sub-cortical hemispheric lesions, the DIR contrast appears to be equally sensitive to the MP2RAGE and SPACE, but most sensitive for cerebellar MS plaques. The DIR sequence is also the one that reveals cortical hemispheric lesions best. T1 relaxation times at 3T in the WM and GM of the hemispheres and the cerebellum, as obtained with the MP2RAGE sequence, are shown in table 2. Extending previous studies, we confirm overall longer T1-values in lesion tissue and higher standard deviations compared to the non-lesion tissue and control tissue in healthy controls. We hypothesize a biological (different degree of axonal loss and demyelination) rather than technical origin. Conclusion In this study, we applied 5 MR contrasts including two novel sequences to investigate the contrast of highest sensitivity for early MS diagnosis. In addition, we characterized for the first time the T1 relaxation time in cortical and sub-cortical regions of the hemispheres and the cerebellum. Results are in agreement with previous publications and meaningful biological interpretation of the data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The response of Arabidopsis to stress caused by mechanical wounding was chosen as a model to compare the performances of high resolution quadrupole-time-of-flight (Q-TOF) and single stage Orbitrap (Exactive Plus) mass spectrometers in untargeted metabolomics. Both instruments were coupled to ultra-high pressure liquid chromatography (UHPLC) systems set under identical conditions. The experiment was divided in two steps: the first analyses involved sixteen unwounded plants, half of which were spiked with pure standards that are not present in Arabidopsis. The second analyses compared the metabolomes of mechanically wounded plants to unwounded plants. Data from both systems were extracted using the same feature detection software and submitted to unsupervised and supervised multivariate analysis methods. Both mass spectrometers were compared in terms of number and identity of detected features, capacity to discriminate between samples, repeatability and sensitivity. Although analytical variability was lower for the UHPLC-Q-TOF, generally the results for the two detectors were quite similar, both of them proving to be highly efficient at detecting even subtle differences between plant groups. Overall, sensitivity was found to be comparable, although the Exactive Plus Orbitrap provided slightly lower detection limits for specific compounds. Finally, to evaluate the potential of the two mass spectrometers for the identification of unknown markers, mass and spectral accuracies were calculated on selected identified compounds. While both instruments showed excellent mass accuracy (<2.5ppm for all measured compounds), better spectral accuracy was recorded on the Q-TOF. Taken together, our results demonstrate that comparable performances can be obtained at acquisition frequencies compatible with UHPLC on Q-TOF and Exactive Plus MS, which may thus be equivalently used for plant metabolomics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The evaluation of new antimalarial agents using older methods of monitoring sensitivity to antimalarial drugs are laborious and poorly suited to discriminate stage-specific activity. We used flow cytometry to study the effect of established antimalarial compounds, cysteine protease inhibitors, and a quinolone against asexual stages of Plasmodium falciparum. Cultured P. falciparum parasites were treated for 48 h with different drug concentrations and the parasitemia was determined by flow cytometry methods after DNA staining with propidium iodide. P. falciparum erythrocytic life cycle stages were readily distinguished by flow cytometry. Activities of established and new antimalarial compounds measured by flow cytometry were equivalent to results obtained with microscopy and metabolite uptake assays. The antimalarial activity of all compounds was higher against P. falciparum trophozoite stages. Advantages of flow cytometry analysis over traditional assays included higher throughput for data collection, insight into the stage-specificity of antimalarial activity avoiding use of radioactive isotopes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To assess whether patients' characteristics and healthcare resources consumption and costs were different between native and migrant populations in Switzerland. METHODS: All adult patients followed-up in the Swiss HIV-cohort study in our institution during 2000-2003 were considered. Patients' characteristics were retrieved from the cohort database. Hospital and outpatient resource use were extracted from individual charts and valued with 2002 tariffs. RESULTS: The 66 migrants were younger (29 +/- 8 years versus 37 +/- 11, p < 0.001), less often of male gender (38 % versus 70 %, p < 0.001), predominantly infected via heterosexual contact (87 % versus 52 %, p < 0.01), with lower mean CD4 level at enrollment (326 +/- 235 versus 437 +/- 305, p = 0.002) than their 200 native counterparts. Migrants had fewer hospitalizations, more frequent outpatient visits, laboratory tests, and lower total cost of care per year of follow-up (<euro> 2'215 +/- 4'206 versus 4'155 +/- 12'304, p = 0.037). Resource use and costs were significantly higher in people with < 200 CD4 cell counts in both groups. CONCLUSIONS: Migrant population had more advanced disease, more outpatient visits but less hospitalizations, resulting in lower costs of care when compared with native population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In occupational exposure assessment of airborne contaminants, exposure levels can either be estimated through repeated measurements of the pollutant concentration in air, expert judgment or through exposure models that use information on the conditions of exposure as input. In this report, we propose an empirical hierarchical Bayesian model to unify these approaches. Prior to any measurement, the hygienist conducts an assessment to generate prior distributions of exposure determinants. Monte-Carlo samples from these distributions feed two level-2 models: a physical, two-compartment model, and a non-parametric, neural network model trained with existing exposure data. The outputs of these two models are weighted according to the expert's assessment of their relevance to yield predictive distributions of the long-term geometric mean and geometric standard deviation of the worker's exposure profile (level-1 model). Bayesian inferences are then drawn iteratively from subsequent measurements of worker exposure. Any traditional decision strategy based on a comparison with occupational exposure limits (e.g. mean exposure, exceedance strategies) can then be applied. Data on 82 workers exposed to 18 contaminants in 14 companies were used to validate the model with cross-validation techniques. A user-friendly program running the model is available upon request.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Skin notations are used as a hazard identification tool to flag chemicals associated with a potential risk related to transdermal penetration. The transparency and rigorousness of the skin notation assignment process have recently been questioned. We compared different approaches proposed as criteria for these notations as a starting point for improving and systematizing current practice. METHODS: In this study, skin notations, dermal acute lethal dose 50 in mammals (LD(50)s) and two dermal risk indices derived from previously published work were compared using the lists of Swiss maximum allowable concentrations (MACs) and threshold limit values (TLVs) from the American Conference of Governmental Industrial Hygienists (ACGIH). The indices were both based on quantitative structure-activity relationship (QSAR) estimation of transdermal fluxes. One index compared the cumulative dose received through skin given specific exposure surface and duration to that received through lungs following inhalation 8 h at the MAC or TLV. The other index estimated the blood level increase caused by adding skin exposure to the inhalation route at kinetic steady state. Dermal-to-other route ratios of LD(50) were calculated as secondary indices of dermal penetrability. RESULTS: The working data set included 364 substances. Depending on the subdataset, agreement between the Swiss and ACGIH skin notations varied between 82 and 87%. Chemicals with a skin notation were more likely to have higher dermal risk indices and lower dermal LD(50) than chemicals without a notation (probabilities between 60 and 70%). The risk indices, based on cumulative dose and kinetic steady state, respectively, appeared proportional up to a constant independent of chemical-specific properties. They agreed well with dermal LD(50)s (Spearman correlation coefficients -0.42 to -0.43). Dermal-to-other routes LD(50) ratios were moderately associated with QSAR-based transdermal fluxes (Spearman correlation coefficients -0.2 to -0.3). CONCLUSIONS: The plausible but variable relationship between current skin notations and the different approaches tested confirm the need to improve current skin notations. QSAR-based risk indices and dermal toxicity data might be successfully integrated in a systematic alternative to current skin notations for detecting chemicals associated with potential dermal risk in the workplace. [Authors]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stress radiographs have been recommended in order to obtain a better objective quantification of abnormal compartment knee motion. This tool has showed to be superior in quantifying a posterior cruciate ligament (PCL) lesion compared to clinical or arthrometer evaluation. Different radiographic techniques have been described in literature to quantify posterior pathological laxity. In this study we evaluated the total amount of posterior displacement (PTD) and side to side difference (SSD), before and after surgical reconstruction of PCL or PCL and posterolateral complex (PLC), using two different stress radiography techniques (Telos stress and kneeling view). Twenty patients were included in this study. We found a statistical significant difference about both total PTD and SSD among the two techniques preoperatively and at follow-up, with greatest values occurring using the kneeling view. Although stress radiographies has been introduced to allow an objective quantification of laxity in ligamentous injured knee, we believe that further studies on a large numbers of subjects are required to define the relationship between PTD values, measured with stress knee radiography, particularly using kneeling view, and ligamentous knee injury, in order to obtain a real useful tool in the decision making process, as well as to evaluate the outcome after ligamentous surgery.