941 resultados para catheterization Swan Ganz
Resumo:
After trans-catheter aortic valve implantation (TAVI), the need for postinterventional pacemaker (PM) implantation can occur in as many as 10-50% of cases, but it is not yet clear, how this need can be predicted. The aim of this study was to assess the possible predictive factors of post TAVI PM implantation based on Computed Tomography (CT) measured aortic valve calcification and its distribution.
Resumo:
In most patients with atrial fibrillation (AF) and stroke, there is thrombotic embolization from the left atrial appendage (LAA). Percutaneous closure of the LAA is a novel alternative for the treatment of patients with AF at a high risk of stroke, in whom long-term anticoagulation therapy is not possible or not desired. This study details the initial experience with the Amplatzer Cardiac Plug (ACP) in humans.
Resumo:
Objectives: We aimed at comparing the long term clinical outcome of SES and PES in routine clinical practice. Background: Although sirolimus-eluting stents (SES) more effectively reduce neointimal hyperplasia than paclitaxel-eluting stents (PES), uncertainty prevails whether this difference translates into differences in clinical outcomes outside randomized controlled trials with selected patient populations and protocol-mandated angiographic follow-up. Methods: Nine hundred and four consecutive patients who underwent implantation of a drug-eluting stent between May 2004 and February 2005: 467 patients with 646 lesions received SES, 437 patients with 600 lesions received PES. Clinical follow-up was obtained at 2 years without intervening routine angiographic follow-up. The primary endpoint was a composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). Results: At 2 years, the primary endpoint was less frequent with SES (12.9%) than PES (17.6%, HR = 0.70, 95% CI 0.50–0.98, P = 0.04). The difference in favor of SES was largely driven by a lower rate of target lesion revascularisation (TLR; 4.1% vs. 6.9%, P = 0.05), whereas rates of death (6.4% vs. 7.6%, P = 0.49), MI (1.9% vs. 3.2%, P = 0.21), or definite stent thrombosis (0.6% vs. 1.4%, P = 0.27) were similar for both stent types. The benefit regarding reduced rates of TLR was significant in nondiabetic (3.6% vs. 7.1%, P = 0.04) but not in diabetic patients (5.6% vs. 6.1%, P = 0.80). Conclusions: SES more effectively reduced the need for repeat revascularization procedures than PES when used in routine clinical practice. The beneficial effect is maintained up to 2 years and may be less pronounced in diabetic patients.
Resumo:
Objective Femoroacetabular impingement may be a risk factor for hip osteoarthritis in men. An underlying hip deformity of the cam type is common in asymptomatic men with nondysplastic hips. This study was undertaken to examine whether hip deformities of the cam type are associated with signs of hip abnormality, including labral lesions and articular cartilage damage, detectable on magnetic resonance imaging (MRI). Methods In this cross-sectional, population-based study in asymptomatic young men, 1,080 subjects underwent clinical examination and completed a self-report questionnaire. Of these subjects, 244 asymptomatic men with a mean age of 19.9 years underwent MRI. All MRIs were read for cam-type deformities, labral lesions, cartilage thickness, and impingement pits. The relationship between cam-type deformities and signs of joint damage were examined using logistic regression models adjusted for age and body mass index. Odds ratios (ORs) and 95% confidence intervals (95% CIs) were determined. Results Sixty-seven definite cam-type deformities were detected. These deformities were associated with labral lesions (adjusted OR 2.77 [95% CI 1.31, 5.87]), impingement pits (adjusted OR 2.9 [95% CI 1.43, 5.93]), and labral deformities (adjusted OR 2.45 [95% CI 1.06, 5.66]). The adjusted mean difference in combined anterosuperior femoral and acetabular cartilage thickness was −0.19 mm (95% CI −0.41, 0.02) lower in those with cam-type deformities compared to those without. Conclusion Our findings indicate that the presence of a cam-type deformity is associated with MRI-detected hip damage in asymptomatic young men.
Resumo:
It is proposed that an ideal osteochondral allograft for cartilage repair consists of a devitalized bone but functional cartilage. The different modes of nutrient supply in vivo for bone (vascular support) and cartilage (diffusion) suggest that a modulation of storage conditions could differentially affect the respective cells, resulting in the proposed allograft. For this purpose, osteochondral tissues from porcine humeral heads were either cultured at 37°C for up to 24 hr or stored at 4°C for 24 hr, the temperature at which osteochondral allografts are routinely stored. Functionality of the cells was assessed by in situ hybridization for transcripts encoding collagen types I and II. At 37°C, a time-dependent significant reduction of the bone surface covered with functional cells was observed with only 5% ± 5% coverage left at 24 hr compared with 41% ± 10% at 0 hr. Similarly, cartilage area containing functional cells was significantly reduced from 84% ± 7% at 0 hr to 70% ± 3% after 24 hr. After 24 hr at 4°C, a significantly reduced amount of functional cells covering bone surfaces was observed (27% ± 5%) but not of cells within the cartilage (79% ± 8%). In the applied experimental setup, bone cells were more affected by tissue culture at 37°C than cartilage cells. Even though chondrocytes appear to be more sensitive to 37°C than to 4°C, the substantially reduced amount of functional bone cells at 37°C warrants further investigation of whether a preincubation of osteochondral allografts at 37°C--prior to regular storage at 4°C--might result in an optimized osteochondral allograft with devitalized bone but viable cartilage.
Resumo:
The iliocapsularis muscle is a little known muscle overlying the anterior hip capsule postulated to function as a stabilizer of dysplastic hips. Theoretically, this muscle would be hypertrophied in dysplastic hips and, conversely, atrophied in stable and well-constrained hips. However, these observations have not been confirmed and the true function of this muscle remains unknown.
Resumo:
The authors report on the use of 5 French diagnostic catheters to deliver a stent-on-a-wire system during a double vessel coronary intervention.
Resumo:
Temporary percutaneous left ventricular assist devices (TPLVAD) can be inserted and removed in awake patients. They substitute left ventricular function for a period of up to a few weeks and provide an excellent backup and bridge to recovery or decision.
Resumo:
The ABSORB cohort A trial using the bioresorbable everolimus-eluting scaffold (BVS revision 1.0, Abbott Vascular) demonstrated a slightly higher acute recoil with BVS than with metallic stents. To reinforce the mechanical strength of the scaffold, the new BVS scaffold (revision 1.1) with modified strut design was developed and tested in the ABSORB cohort B trial. This study sought to evaluate and compare the in vivo acute scaffold recoil of the BVS revision 1.0 in ABSORB cohort A and the BVS revision 1.1 in ABSORB cohort B with the historical recoil of the XIENCE V® everolimus-eluting metal stent (EES, SPIRIT I and II).
Resumo:
Accurate diagnosis of the causes of chest pain and dyspnea remain challenging. In this preliminary observational study with a 5-year follow-up, we attempted to find a simplified approach to selecting patients with chest pain needing immediate care based on the initial evaluation in ED. During a 24-month period were randomly selected 301 patients and a conditional inference tree (CIT) was used as the basis of the prognostic rule. Common diagnoses were musculoskeletal chest pain (27%), ACS (19%) and panic attack (12%). Using variables of ACS symptoms we estimated the likelihood of ACS based on a CIT to be high at 91% (32), low at 4% (198) and intermediate at 20.5-40% in (71) patients. Coronary catheterization was performed within 24 hours in 91% of the patients with ACS. A culprit lesion was found in 79%. Follow-up (median 4.2 years) information was available for 70% of the patients. Of the 164 patients without ACS who were followed up, 5 were treated with revascularization for stable angina pectoris, 2 were treated with revascularization for myocardial infarction, and 25 died. Although a simple triage decision tree could theoretically help to efficient select patients needing immediate care we need also to be vigilant for those presenting with atypical symptoms.