981 resultados para Ultrasound examination
Resumo:
Ultrasound elastography tracks tissue displacements under small levels of compression to obtain images of strain, a mechanical property useful in the detection and characterization of pathology. Due to the nature of ultrasound beamforming, only tissue displacements in the direction of beam propagation, referred to as 'axial', are measured to high quality, although an ability to measure other components of tissue displacement is desired to more fully characterize the mechanical behavior of tissue. Previous studies have used multiple one-dimensional (1D) angled axial displacements tracked from steered ultrasound beams to reconstruct improved quality trans-axial displacements within the scan plane ('lateral'). We show that two-dimensional (2D) displacement tracking is not possible with unmodified electronically-steered ultrasound data, and present a method of reshaping frames of steered ultrasound data to retain axial-lateral orthogonality, which permits 2D displacement tracking. Simulated and experimental ultrasound data are used to compare changes in image quality of lateral displacements reconstructed using 1D and 2D tracked steered axial and steered lateral data. Reconstructed lateral displacement image quality generally improves with the use of 2D displacement tracking at each steering angle, relative to axial tracking alone, particularly at high levels of compression. Due to the influence of tracking noise, unsteered lateral displacements exhibit greater accuracy than axial-based reconstructions at high levels of applied strain. © 2011 SPIE.
Resumo:
For raw, iced and frozen samples of fish and prawn, significant difference was observed in total plate counts done with various diluents, the significance level ranging from 5% to 0.1%. For raw fish, N-saline, seawater and quarter strength Ringers' solution gave maximum total plate counts. In the case of iced-fish, n-saline yielded highest total plate counts. For frozen samples, however, peptone water and n-saline gave good recoveries. Trials with suitable combinations of diluents showed that though some of them were as good as the control, namely n-saline, none were superior in any way.
Resumo:
The phylogenetic relationships among rhacophorid frogs are under dispute. We use partial sequences of three mitochondrial (12S rRNA, 16S rRNA, and cytochrome b) and three nuclear protein-coding (Rag-1 rhodopsin exon 1, and tyrosinase exon 1) genes from 57
Resumo:
A critical examination of the market quality of split, dried and smoked bream (Tilapia spp.) was chemically, bacteriologically and organoleptically conducted for the period of August 1968 to January 1969. The aim of this survey was to obtain basic information for the development of national quality standards for the commodity. Relationships of cooked meat score to pH, fish size, appearance and smell score, and water content wcre significantly correlated and responsive. Therefore, these parameters were proposed to be used as indices for the quality standards of the products.
Resumo:
Integration of a piezoelectric high frequency ultrasound (HFUS) array with a microfabricated application specific integrated circuit (ASIC) performing a range of functions has several advantages for ultrasound imaging. The number of signal cables between the array/electronics and the data acquisition / imaging system can be reduced, cutting costs and increasing functionality. Electrical impedance matching is also simplified and the same approach can reduce overall system dimensions for applications such as endoscopic ultrasound. The work reported in this paper demonstrates early ASIC operation with a piezocomposite HFUS array operating at approximately 30 MHz. The array was tested in three different modes. Clear signals were seen in catch-mode, with an external transducer as a source of ultrasound, and in pitch-mode with the external transducer as a receiver. Pitch-catch mode was also tested successfully, using sequential excitation on three array elements, and viable signals were detected. However, these were relatively small and affected by interference from mixed-signal sources in the ASIC. Nevertheless, the functionality and compatibility of the two main components of an integrated HFUS - ASIC device have been demonstrated and the means of further optimization are evident.
Resumo:
Interest is growing around the application of lean techniques to new product introduction (NPI). Although a relatively emergent topic compared with the application of 'lean' within the factory, since 2000 there has been an exponential rise in the literature on this subject. However, much of this work focuses on describing and extolling the virtues of the 'Toyota approach' to design. Therefore, by way of a stock take for the UK, the present authors' research has set out to understand how well lean product design practices have been adopted by leading manufacturers. This has been achieved by carrying out in-depth case studies with three carefully selected manufacturers of complex engineered products. This paper describes these studies, the detailed results and subsequent findings, and concludes that both the awareness and adoption of practices is generally embryonic and far removed from the theory advocated in the literature. © IMechE 2007.
Resumo:
Abstract—There are sometimes occasions when ultrasound beamforming is performed with only a subset of the total data that will eventually be available. The most obvious example is a mechanically-swept (wobbler) probe in which the three-dimensional data block is formed from a set of individual B-scans. In these circumstances, non-blind deconvolution can be used to improve the resolution of the data. Unfortunately, most of these situations involve large blocks of three-dimensional data. Furthermore, the ultrasound blur function varies spatially with distance from the transducer. These two facts make the deconvolution process time-consuming to implement. This paper is about ways to address this problem and produce spatially-varying deconvolution of large blocks of three-dimensional data in a matter of seconds. We present two approaches, one based on hardware and the other based on software. We compare the time they each take to achieve similar results and discuss the computational resources and form of blur model that each requires.
Resumo:
This paper is in two parts and addresses two of getting more information out of the RF signal from three-dimensional (3D) mechanically-swept medical ultrasound . The first topic is the use of non-blind deconvolution improve the clarity of the data, particularly in the direction to the individual B-scans. The second topic is imaging. We present a robust and efficient approach to estimation and display of axial strain information. deconvolution, we calculate an estimate of the point-spread at each depth in the image using Field II. This is used as of an Expectation Maximisation (EM) framework in which ultrasound scatterer field is modelled as the product of (a) a smooth function and (b) a fine-grain varying function. the E step, a Wiener filter is used to estimate the scatterer based on an assumed piecewise smooth component. In the M , wavelet de-noising is used to estimate the piecewise smooth from the scatterer field. strain imaging, we use a quasi-static approach with efficient based algorithms. Our contributions lie in robust and 3D displacement tracking, point-wise quality-weighted , and a stable display that shows not only strain but an indication of the quality of the data at each point in the . This enables clinicians to see where the strain estimate is and where it is mostly noise. deconvolution, we present in-vivo images and simulations quantitative performance measures. With the blurred 3D taken as OdB, we get an improvement in signal to noise ratio 4.6dB with a Wiener filter alone, 4.36dB with the ForWaRD and S.18dB with our EM algorithm. For strain imaging show images based on 2D and 3D data and describe how full D analysis can be performed in about 20 seconds on a typical . We will also present initial results of our clinical study to explore the applications of our system in our local hospital. © 2008 IEEE.
Resumo:
A number of acrosome reaction (AR) initiators have been found to be effective in inducing AR of human, laboratory and domestic animal sperm. Using an improved simple fluorescence microscopy, effects of gamma-aminobutyric acid (GABA), progesterone and ionophore A23187 on sperm AR of tree shrew, a useful animal model in biomedical research, have been investigated. Spontaneous AR in 4.92-7.53% of viable sperm was observed. Complete AR in 10.31-18.25% of viable tree shrew sperm was obviously induced by 5 mu M and 10 mu M calcium ionophore A23187, 1 mM GABA, and 5 mu M progesterone, and there were no significant differences between their abilities to initiate complete AR. No significant differences of AR percentages between 1- and 2-h treatments with A23187, progesterone and/or GABA were observed. These results suggested that the responses of tree shrew sperm to these AR initiators are similar to that of human and other mammalian sperm. (C) 1997 Elsevier Science B.V.
Resumo:
Several elastoplastic soil models have been proposed over the years that are formulated in strain space rather than stress space due to certain analytical and computational advantages. One such model, BRICK (Simpson 1992), has been continuously utilized and developed for industrial applications within Arup Geotechnics for more than two decades. This paper aims to describe the advantages and difficulties associated with strain space modeling. In addition, it will show how recent advances in modeling the effects of stress history, stiffness anisotropy, strength anisotropy and time-dependence in conventional stress space models can be transferred to the BRICK model. © 2010 Taylor & Francis Group, London.
Resumo:
Purpose: The purpose of this study is to examine a buyer's adoption of servitization and the associated implications for the relationships with its suppliers. Design/methodology/approach: The authors use the case study approach to examine the tripartite relationship between a manufacturing company and two of its two suppliers. The paper explores the perspectives of employees on multiple organisational levels, and collects evidence on both sides of a relationship. The authors use template analysis utilising Cannon and Perreault's relationship connectors framework to analyse the data. Findings: There are overarching implications of servitization adoption for buyer-supplier relationships. The implications are notable in all five relationship connectors. Parties expected more open exchange of information, operational linkages were strengthened and changes in the structural arrangements of relationships were witnessed. Legal contracts are complemented by relational norms. The authors also observed a departure away from a win-lose mentality and increased levels of supplier adaptation to support the buyer's provision of integrated solutions. Research limitations/implications: The findings are confined to this tripartite relationship and to an extent are context specific. Practical implications: The study unveils buyer-supplier relationships in a servitized context and provides managers with a better understanding of some of the potential implications that the adoption of a servitization strategy may have for managing buyer-supplier relationships. Originality/value: This is the first empirical study that explores the implications of servitization on buyer-supplier relationships. It advances the understanding of the implications that the adoption of servitization has on the manner in which two parties interrelate and conduct commercial exchange. © Emerald Group Publishing Limited.
Resumo:
The analysis of scientific data is integral to materials engineering and science. The correlation between measured variables is often quantified by estimating the coefficient of determination or the r2 value. This is the recognised procedure for determining linear relationships. The authors review the derivation of the r2 value and derive an associated quantity, termed the relative deviation (RD), which is the ratio of the root mean square of the deviations about the fitted line to the root mean square of the deviations about the y bar line expressed as a percentage. The relative deviation has an advantage over the coefficient of determination in that it has greater numerical sensitivity to changes in the spread of data about the fitted line, especially when the scatter is small. In addition, the relative deviation is able to define, in percentage terms, the reduction in scatter when different independent variables are correlated with a common dependent variable. Four case studies in the materials field (aggregate crushing value, Atterberg limits, permeability and creep of asphalt) from work carried out at the Queensland Main Roads Department are presented to show the use of the new parameter RD.
Resumo:
High-frequency ultrasound is needed for medical imaging with high spatial resolution. A key issue in the development of ultrasound imaging arrays to operate at high frequencies (≥30 MHz) is the need for photolithographic patterning of array electrodes. To achieve this directly on 1-3 piezocomposite, the material requires not only planar, parallel, and smooth surfaces, but also an epoxy composite filler that is resistant to chemicals, heat, and vacuum. This paper reports, first, on the surface finishing of 1-3 piezocomposite materials by lapping and polishing. Excellent surface flatness has been obtained, with an average surface roughness of materials as low as 3 nm and step heights between ceramic/polymer of ∼80 nm. Subsequently, high-frequency array elements were patterned directly on top of these surfaces using a photolithography process. A 30-MHz linear array electrode pattern with 50-μm element pitch has been patterned on the lapped and polished surface of a high-frequency 1-3 piezocomposite. Excellent electrode edge definition and electrical contact to the composite were obtained. The composite has been lapped to a final thickness of ∼55 μm. Good adhesion of electrodes on the piezocomposite has been achieved and electrical impedance measurements have demonstrated their basic functionality. The array was then packaged, and acoustic pulse-echo measurements were performed. These results demonstrate that direct patterning of electrodes by photolithography on 1-3 piezocomposite is feasible for fabrication of high-frequency ultrasound arrays. Furthermore, this method is more conducive to mass production than other reported array fabrication techniques.
Resumo:
Real-time cardiac ultrasound allows monitoring the heart motion during intracardiac beating heart procedures. Our application assists atrial septal defect (ASD) closure techniques using real-time 3D ultrasound guidance. One major image processing challenge is the processing of information at high frame rate. We present an optimized block flow technique, which combines the probability-based velocity computation for an entire block with template matching. We propose adapted similarity constraints both from frame to frame, to conserve energy, and globally, to minimize errors. We show tracking results on eight in-vivo 4D datasets acquired from porcine beating-heart procedures. Computing velocity at the block level with an optimized scheme, our technique tracks ASD motion at 41 frames/s. We analyze the errors of motion estimation and retrieve the cardiac cycle in ungated images. © 2007 IEEE.