986 resultados para Ultrasonography
Resumo:
The aim of this study was to evaluate modifications occurring in semitendinous muscle after transposition as a ventral perineal muscle flap using electromyography, ultrasonography, and morphological studies. Ten male crossbreed dogs of 3-4 year old were used. The left semitendinous muscle was cut close to the popliteus lymph node, rotated and sutured at the perineal region. The contralateral muscle was considered as control. Motor nerve conduction studies of both sciatic-tibial nerves, and electromyographic and ultrasonographic examinations of both semitendinous muscles were performed before surgery and 15, 30, 60, and 90 days postoperatively. Semitendinous muscle samples were collected for morphological analysis 90 days after surgery. No alterations were observed in clinical gait examinations, or in goniometrical and electroneuromyographical studies in pelvic limbs after surgery. Electromyography demonstrated that the transposed muscle was able to contract, but atrophy was detected by ultrasonography and morphological analysis.
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.
Resumo:
OBJETIVO: Utilizar a ultrassonografia do esôfago intra-abdominal para avaliar o tempo de trânsito esofágico para água e iogurte, em posição ortostática, e avaliar a influência do gênero e índice de massa corpórea. MATERIAIS E MÉTODOS: Foram estudados 89 indivíduos adultos jovens, sem clínica de doenças do trato gastrintestinal superior, sendo 40 do gênero feminino (média de 20,13 ± 1,62 anos) e 49 do gênero masculino (média de 20,43 ± 2,17 anos). O tempo de trânsito esofágico foi cronometrado, com o paciente em posição ortostática, durante a deglutição de água e iogurte. RESULTADOS: O tempo de trânsito esofágico para as mulheres e para os homens foi, respectivamente: para água, de 5,84 ± 1,60 segundos versus 6,66 ± 1,68 segundos, e para iogurte, de 9,12 ± 1,96 segundos versus 9,28 ± 1,70 segundos. Não se constatou diferença entre os gêneros masculino e feminino, apesar de o fator índice de massa corpórea ser menor nas mulheres. CONCLUSÃO: Os dados obtidos do tempo de trânsito esofágico para alimento líquido (água) e pastoso (iogurte), em posição ortostática, em adultos jovens não mostraram diferença entre os gêneros, mesmos nas mulheres com índice de massa corpórea menor em relação aos homens.
Resumo:
This is a case report of a true and dissecting aneurysm of the superior labial artery in a 51-year-old patient without risk factors for vascular pathology. The patient complained of swelling of the upper lip, mostly on the left side. A Doppler ultrasonography was used in the diagnosis. The definitive treatment was surgical resection, and the histopathological analysis confirmed the diagnosis. The progress of the patient was satisfactory, leaving a slight change in sensitivity in the area. This seems to be the first reported case of true and dissecting aneurysm of the superior labial artery in the medical literature.
Resumo:
Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]
Resumo:
Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.
Resumo:
O diagnóstico da trombose venosa profunda sintomática está bem estabelecido com o uso do mapeamento dúplex, que apresenta sensibilidade de 100% e especificidade de 98%, para trombose venosa profunda proximal, e sensibilidade de 94% e especificidade de 75%, para distal. Na trombose venosa profunda recente e assintomática, o diagnóstico com o mapeamento dúplex ainda não está bem estabelecido, mostrando uma queda na acurácia desse método diagnóstico. Essa queda é devida ao fato de o trombo recente não ser oclusivo, apresentar a mesma ecogenicidade do sangue e uma consistência diminuída, prejudicando o teste da compressibilidade, que é o mais sensível para diagnóstico da trombose venosa profunda. Nesta revisão, serão revistos artigos publicados que avaliaram a acurácia do mapeamento dúplex no diagnóstico da trombose venosa profunda assintomática.
Resumo:
Congenital hypothyroidism associated with thyroid hypoplasia can be caused by several genetic defects, including mutations in the TSH beta -subunit, the TSH receptor, the G(A)alpha -subunit, and the transcription factor PAX8. Four girls with sporadic congenital hypothyroidism and hypoplastic thyroid glands were analyzed for mutations in PAX8 and TTF2 (FKHL15). Mutations in the coding region of the TSH beta -subunit gene, the TSH receptor gene, and exons 8 and 9 of G(mu)alpha had been excluded previously. Serum TSH concentrations were 150 mU/liter or more, TG levels were within normal limits, and thyroid autoantibodies were absent. Technetium scintigraphies did not reveal the presence of thyroid tissue, but ultrasonography documented hypoplastic, normally located glands.One patient was found to harbor a heterozygous transversion 119A -->C in exon 3 of PAX8 replacing a conserved glutamine by proline in the paired box domain (Q40P). Analysis of her family members revealed that her mother, who has a thyroid gland of normal size and mild, adult-onset autoimmune hypothyroidism, is also heterozygous for this mutation. Functional analyses of the PAX8 Q40P mutation showed impaired binding to a PAX8 response element and absent transactivation of a thyroid peroxidase promoter luciferase reporter gene.These findings confirm the important role of PAX8 in the development of the thyroid, but they indicate that PAX8 gene mutations may have a variable penetrance or expressivity. The absence of mutations in the coding sequences of the analyzed genes in the three other patients supports the concept that the pathogenesis of congenital hypothyroidism associated with thyroid hypoplasia is diverse.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Diversos fatores podem contribuir para a formação de cálculos urinários, dentre estes, o desequilíbrio nutricional e a dureza da água consumida pelos ruminantes. O objetivo deste estudo foi identificar as características de propriedades que predispõem à urolitíase, através da avaliação da água, da dieta e determinações séricas e urinárias de cálcio, fósforo, magnésio, cloretos, sódio, potássio, cálculo da excreção fracionada (EF) dos eletrólitos, e da creatinina, proteína total, albumina e globulinas séricas. Foram colhidas amostras de sangue e urina de bovinos, Guzerá, criados semi intensivamente, distribuídos por dois grupos. O primeiro denominado grupo urolitíase (Gu), composto de animais com histórico, sinais clínicos e confirmação ultrassonográfica que apresentavam urolitíase; o segundo: grupo controle (Gc), sem histórico, nem sintomas da doença. Os bovinos do grupo urolitíase consumiam água com dureza total na concentração de 166,0mg CaCO3/L. A dieta dos animais do Gu apresentava maior concentração de fósforo e relação Ca:P inadequada. Os teores de fósforo sérico e urinário dos animais do Gu foram maiores do que os do Gc, assim como a concentração sérica de magnésio (p<0,05). Não houve aumento nas concentrações de creatinina no grupo urolitíase, mas ocorreu hipoproteinemia por hipoglobulinemia (p<0,05). As EFs de cálcio, fósforo e sódio não diferiram entre os grupos (p>0,05), mas houve diminuição significativa nas EFs de magnésio, cloretos e de potássio do grupo urolitíase (p<0,05). A união destes fatores contribuiu para a ocorrência da urolitíase, sendo dureza total da água e a alta concentração de fósforo na dieta os principais fatores na gênese dos cálculos em bovinos.
Resumo:
Uma cadela, Dachshund, quatro anos, foi encaminhada ao H.V. da FMVZ-UNESP-Botucatu-SP com histórico de prostração, emagrecimento progressivo, anorexia, cansaço e tosse seca. Ao exame clínico observou-se apatia, secreção nasal serosa bilateral e dispnéia intensa. Radiografia torácica demonstrou efusão pleural, edema pulmonar acentuado, desvio dorsal da traquéia e possível massa mediastinal. A ultra-sonografia, após drenagem torácica, confirmou a presença de massa mediastinal, sendo classificada como neoplasia maligna de origem epitelial pela citologia aspirativa por agulha fina. O animal veio a óbito logo após o diagnóstico de neoplasia. À necropsia constatou-se massa mediastinal encapsulada, consistência macia e superfície de corte com coloração branco-acinzentada e áreas necrótico-hemorrágicas, localizada na região ântero-ventral do tórax. O exame histopatológico demonstrou células epiteliais neoplásicas, células linfóides (timócitos) com morfologia normal, vasos sangüíneos de pequeno e médio calibre, formações císticas com conteúdo eosinofílico e corpúsculos de Hassall. A imunohistoquímica apresentou positividade para citoqueratina AE1/AE3 e UCHL, confirmando o diagnóstico de timoma.
Resumo:
CONTEXTO E OBJETIVO: A biópsia da próstata não é um procedimento isento de riscos. Existe preocupação com respeito às complicações e quais seriam os melhores antibióticos usados antes do procedimento. O objetivo foi determinar a taxa de complicações e os possíveis fatores de risco para complicação na biópsia da próstata. TIPO DE ESTUDO E LOCAL: Estudo prospectivo clínico, realizado no Hospital das Clínicas de Botucatu. MÉTODOS: Foram realizadas biópsias em 174 pacientes que apresentavam anormalidade ao exame digital da próstata ou antígeno prostático específico maior que 4 ng/ml ou ambos. Todos os pacientes realizaram enema e antibioticoprofilaxia previamente ao exame. As complicações foram anotadas após o término do procedimento e em consultas posteriores. Algumas condições foram investigadas como possíveis fatores de risco para biópsias de próstata: idade, câncer da próstata, diabetes melito, hipertensão arterial sistêmica, antecedentes de prostatite, uso de ácido acetilsalicílico, volume prostático, número de biópsias e uso de sonda vesical. RESULTADOS: As complicações hemorrágicas foram mais comuns (75,3%) enquanto que as infecciosas ocorreram em 19% dos casos. O tipo mais freqüente foi a hematúria, ocorrendo em 56% dos pacientes. A infecção do trato urinário ocorreu em 16 pacientes (9,2%). Sepse foi observada em três pacientes (1,7%). Não houve óbitos. em 20% dos pacientes não foram observadas complicações após o exame. A presença da sonda vesical foi fator de risco para complicações infecciosas (p < 0,05). O número maior de amostras nas biópsias foi relacionado à hematúria, sangramento retal e complicações infecciosas (p < 0,05). As demais condições investigadas não se relacionaram com complicações pós-biópsia da próstata. CONCLUSÕES: As complicações pós-biópsia da próstata foram em sua maioria autolimitadas. A taxa de complicações graves foi baixa, sendo a biópsia de próstata guiada pelo ultra-som segura e eficaz. A retirada de um maior número de fragmentos na biópsia relaciona-se com hematúria, sangramento retal e complicações infecciosas. A sonda vesical foi um fator de risco para complicações infecciosas.
Resumo:
OBJETIVO: Estudo comparativo da receptividade (colaboração) e sensibilidade da seriografia do esôfago, estômago e duodeno em relação à ultrassonografia do esôfago intra-abdominal em pacientes com suspeita de refluxo gastroesofágico. MATERIAIS E MÉTODOS: Foram incluídos no estudo 42 pacientes pediátricos (26 masculinos, com idade média de 33,64 ± 34,33 meses, e 16 femininos, com idade média de 31,02 ± 35,56 meses) com suspeita de refluxo gastroesofágico, os quais foram submetidos, inicialmente, a seriografia do esôfago, estômago e duodeno, e posteriormente, a ultrassonografia do esôfago intra-abdominal. RESUL-TADOS: A análise estatística comparativa entre os sexos e as idades sugere não haver evidência de associação com a colaboração, tanto para a seriografia do esôfago, estômago e duodeno como para a ultrassonografia do esôfago intra-abdominal. Entretanto, na classificação quanto ao tipo de colaboração, a técnica de seriografia do esôfago, estômago e duodeno apresentou menos de 50% de colaboração, enquanto 80,49% dos pacientes colaboraram com a ultrassonografia do esôfago intra-abdominal. Quanto à sensibilidade do diagnóstico de refluxo gastroesofágico, a técnica de ultrassonografia do esôfago intra-abdominal (85,7%) foi significativamente superior à de seriografia do esôfago, estômago e duodeno (47,6%). CONCLUSÃO: O presente estudo sugere que se proceda a ultrassonografia do esôfago intra-abdominal, mesmo na ausência de refluxo gastroesofágico na seriografia do esôfago, estômago e duodeno.
Resumo:
As múltiplas características distintas do leite materno e do leite de vaca fazem com que o esvaziamento gástrico seja mais rápido após ingestão do primeiro. Esta rapidez do esvaziamento gástrico pode estar associada ao esvaziamento da vesícula biliar, também mais rápido. O objetivo do trabalho foi determinar se há diferença na velocidade de esvaziamento da vesícula biliar, por método ultra-sonográfico, após ingestão de leite materno e leite de vaca. Estudamos 47 crianças menores de dois anos, 22 após uma refeição com leite materno e 25 após uma refeição com leite de vaca. A vesícula biliar foi medida após um período de quatro a seis horas de jejum e uma hora após uma refeição (leite materno ou leite de vaca), e a contração da vesícula biliar foi avaliada, em porcentagem, pela diferença de volume da vesícula biliar entre as duas medidas e expressa em porcentagem do volume inicial. As medianas das porcentagens do volume inicial para as crianças alimentadas com leite materno e leite de vaca foram, respectivamente, 92,25% e 53,8%, diferença estatisticamente significativa. Portanto, a contração da vesícula biliar após uma refeição com leite de vaca é muito mais lenta do que aquela após uma refeição com leite materno.