938 resultados para ULTRASOUND-GUIDED BIOPSY
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
In cases of transjugular liver biopsies, the venous angle formed between the chosen hepatic vein and the vena cava main axis in a frontal plane can be large, leading to technical difficulties. In a prospective study including 139 consecutive patients who underwent transjugular liver biopsy using the Quick-Core biopsy set, the mean venous angle was equal to 49.6 degrees. For 21.1% of the patients, two attempts at hepatic venous catheterization failed because the venous angle was too large, with a mean of 69.7 degrees. In all of these patients, manual reshaping of the distal curvature of the stiffening metallic cannula, by forming a new mean angle equal to 48 degrees , allowed successful completion of the procedure in less than 10 min.
Resumo:
Using a large prospective cohort of over 12,000 women, we determined 2 thresholds (high risk and low risk of hip fracture) to use in a 10-yr hip fracture probability model that we had previously described, a model combining the heel stiffness index measured by quantitative ultrasound (QUS) and a set of easily determined clinical risk factors (CRFs). The model identified a higher percentage of women with fractures as high risk than a previously reported risk score that combined QUS and CRF. In addition, it categorized women in a way that was quite consistent with the categorization that occurred using dual X-ray absorptiometry (DXA) and the World Health Organization (WHO) classification system; the 2 methods identified similar percentages of women with and without fractures in each of their 3 categories, but the 2 identified only in part the same women. Nevertheless, combining our composite probability model with DXA in a case findings strategy will likely further improve the detection of women at high risk of fragility hip fracture. We conclude that the currently proposed model may be of some use as an alternative to the WHO classification criteria for osteoporosis, at least when access to DXA is limited.
Resumo:
Infection of an intervertebral disk is a serious condition. Diagnosis often is elusive and difficult. It is imperative to obtain appropriate microbiological specimens before initiation of treatment. The authors describe a 51-year-old woman with lumbar spondylodiscitis that was because of infection after the placement of an epidural catheter for postoperative analgesia. A spinal magnetic resonance imaging confirmed the diagnosis, but computed tomography-guided fine needle biopsy did not provide adequate material for a microbiologic diagnosis. Laparoscopic biopsies of the involved disk provided good specimens and a diagnosis of Propionibacterium acnes infection. The authors believe that this minimally invasive procedure should be performed when computed tomography-guided fine needle biopsy does not provide a microbiologic diagnosis in spondylodiscitis.
Resumo:
Objectives: Quantitative ultrasound (QUS) is an attractive method for assessing fracture risk because it is portable, inexpensive, without ionizing radiation, and available in areas of the world where DXA is not readily accessible or affordable. However, the diversity of QUS scanners and variability of fracture outcomes measured in different studies is an important obstacle to widespread utilisation of QUS for fracture risk assessment. We aimed in this review to assess the predictive power of heel QUS for fractures considering different characteristics of the association (QUS parameters and fracture outcomes measured, QUS devices, study populations, and independence from DXA-measured bone density).Materials/Methods : We conducted an inverse-variance randomeffects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound &SOS;, stiffness index &SI;, and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic, and major osteoporotic fractures) were reported based on study questions.Results : 21 studies including 55,164 women and 13,742 men were included with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fractures. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99), and QUI was 1.99 (95% CI 1.49-2.67). Validated devices from different manufacturers predicted fracture risks with a similar performance (meta-regression p-values>0.05 for difference of devices). There was no sign of publication bias among the studies. QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip DXA showed a significant and independent association with fracture risk (RR/SD for BUA =1.34 [95%CI 1.22-1.49]).Conclusions : This study confirms that QUS of the heel using validated devices predicts risk of different fracture outcomes in elderly men and women. Further research and international collaborations are needed for standardisation of QUS parameters across various manufacturers and inclusion of QUS in fracture risk assessment tools. Disclosure of Interest : None declared.
Resumo:
To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.
Resumo:
This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.
Resumo:
PURPOSE: Determine the effect of repeated intravitreal injections of ranibizumab (0.5 mg; 0.05 ml) on retrobulbar blood flow velocities (BFVs) using ultrasound imaging quantification in twenty patients with exudative age-related macular degeneration treated for 6 months. METHODS: Visual acuity (ETDRS), central macular thickness (OCT), peak-systolic, end-diastolic and mean-BFVs in central retinal (CRA), temporal posterior ciliary (TPCA) and ophthalmic (OA) arteries were measured before, 2 days, 3 weeks and 6 months after the first injection. Patients were examined monthly and received 1-5 additional injections depending on ophthalmologic examination results. RESULTS: Six months after the first injection, a significant increase in visual acuity 50.9 ± 25.9 versus 44.4 ± 21.7 (p < 0.01) and decrease in mean central macular thickness 267 ± 74 versus 377 ± 115 μm (p < 0.001) were observed compared to baseline. Although mean-BFVs decreased by 16%±3% in CRA and 20%±5% in TPCA (p < 0.001) 2 days after the first injection, no significant change was seen thereafter. Mean-BFVs in OA decreased by 19%±5% at week 3 (p < 0.001). However, the smallest number of injections (two injections) was associated with the longest time interval between the last injection and month 6 (20 weeks) and with the best return to baseline levels for mean-BFVs in CRA, suggesting that ranibizumab had reversible effects on native retinal vascular supply after its discontinuation. Moreover, a significant correlation between the number of injections and percentage of changes in mean-BFVs in CRA was observed at month 6 (R = 0.74, p < 0.001) unlike TPCA or OA. CONCLUSION: Ranibizumab could impair the native choroidal and retinal vascular networks, but its effect seems reversible after its discontinuation.
Resumo:
Knowledge of the pathological diagnosis before deciding the best strategy for treating parasellar lesions is of prime importance, due to the relative high morbidity and side-effects of open direct approaches to this region, known to be rich in important vasculo-nervous structures. When imaging is not evocative enough to ascertain an accurate pathological diagnosis, a percutaneous biopsy through the transjugal-transoval route (of Hartel) may be performed to guide the therapeutic decision.The chapter is based on the authors' experience in 50 patients who underwent the procedure over the ten past years. There was no mortality and only little (mostly transient) morbidity. Pathological diagnosis accuracy of the method revealed good, with a sensitivity of 0.83 and a specificity of 1.In the chapter the authors first recall the surgical anatomy background from personal laboratory dissections. They then describe the technical procedure, as well as the tissue harvesting method. Finally they define indications together with the decision-making process.Due to the constraint trajectory of the biopsy needle inserted through the Foramen Ovale, accessible lesions are only those located in the Meckel trigeminal Cave, the posterior sector of the cavernous sinus compartment, and the upper part of the petroclival region.The authors advise to perform this percutaneous biopsy method when imaging does not provide sufficient evidence of the pathological nature of the lesion, for therapeutic decision. Goal is to avoid unnecessary open surgery or radiosurgery, also inappropriate chemo-/radio-therapy.
Resumo:
PURPOSE: Prostate cancer is the most commonly diagnosed cancer in the United States. The diagnosis or followup of prostate cancer in men older than 50 years is based on digital rectal examination, measurement of the free-to-total prostatic specific antigen ratio and transrectal ultrasound assisted needle biopsy of the prostate. We developed and evaluated a noninvasive method for diagnosing prostate cancer based on the measurement of telomerase activity after prostatic massage in fresh voided urine or after urethral washing. MATERIALS AND METHODS: We obtained 36 specimens of cells after prostatic massage in the fresh voided urine of 16 patients who subsequently underwent radical prostatectomy and after urethral washing in 20 who underwent prostate needle biopsies. Ethylenediaminetetraacetic acid was immediately added to the collected urine or washing to a final concentration of 20 mM. After protein extraction by CHAPS buffer each specimen was tested for telomerase activity in a 2-step modified telomeric repeat amplification protocol assay. The 2 prostate cancer cell lines PC-3 and LNCaP with high telomerase activity were used as a positive control. RESULTS: Telomerase activity was detected in 14 of 24 samples with known prostate cancer (sensitivity 58%). In contrast, no telomerase activity was found in the 12 cases without histological evidence of prostate tumor (specificity 100%). Eight of 9 poorly differentiated cancers expressed telomerase activity (89%), while only 6 of 15 well and moderately differentiated cancers showed telomerase activity (40%). CONCLUSIONS: Our data illustrate that telomerase activity may be detected in voided urine or washing after prostatic massage in patients with prostate cancer. Sensitivity was higher for poorly differentiated tumors. This approach is not currently available for detecting prostate cancer in clinical practice. However, these results are promising and further studies are ongoing.
Resumo:
Résumé Etude de la valeur pronostique de la biopsie du ganglion sentinelle dans une étude prospective monocentrique de 327 patients atteints de mélanome malin But II s'agit de confirmer la validité de la biopsie du ganglion sentinelle, d'en définir la morbidité, d'investiguer les facteurs prédictifs pour le statut du ganglion sentinelle ainsi que de déterminer les facteurs pronostiques pour la survie sans récidive et la survie spécifique liée à la maladie. Matériel et méthode D'octobre 1997 à décembre 2004, 327 patients consécutifs présentant un mélanome cutané primaire des membres, du tronc et de la tête, sans adénopathie clinique ni métastase à distance ont été inclus. La biopsie du ganglion sentinelle a été réalisée selon la triple technique (lymphoscintigraphie, colorant bleu vital et sonde de détection gamma). Les paramètres et la survie ont été évalués par différentes analyses de régression logistique multiple selon Cox et la survie évaluée selon Kaplan Meier. Résultats Vingt-trois pour cent des patients présentaient au moins un ganglion sentinelle métastatique, ce qui était associé de façon significative à l'épaisseur selon Breslow (p<0.001). Le taux de succès de la biopsie du ganglion sentinelle était de 99.1% et sa morbidité de 7.6%. Avec une durée médiane de suivi de 33 mois, la survie sans récidive à 5 ans était de 43% pour les patients avec un ganglion sentinelle positif et de 83.5% pour ceux avec un ganglion sentinelle négatif. La survie spécifique liée à la maladie à 5 ans était de 49% pour les patients avec un ganglion sentinelle positif et de 87.4% pour ceux avec un ganglion sentinelle négatif. Le taux de faux négatif de la biopsie du ganglion sentinelle était de 8.6%. L'analyse multivariée a démontré que la survie sans récidive était significativement péjorée par :l'épaisseur selon Breslow (RR=5.6, p<0.001), un ganglion sentinelle positif (RR=5.0, p<0.001), et le sexe masculin (RR=2.9, p=0.001). La survie spécifique liée à la maladie était significativement diminuée par : un ganglion sentinelle métastatique (RR=8.4, p<O.OOI), le sexe masculin (RR=6.1, p<0.001), l'épaisseur selon Breslow (RR=3.2, p=0.013), et la présence d'une ulcération (RR=2.6, p=0.015). Conclusion La biopsie du ganglion sentinelle est une procédure fiable avec une haute sensibilité (91.4%) et une faible morbidité (7.6%). L'épaisseur selon Breslow était le seul facteur prédictif significatif pour le statut du ganglion sentinelle. La survie sans récidive était péjorée selon un ordre décroissant par :l'épaisseur selon Breslow, un ganglion sentinelle métastatique, et le sexe masculin. De façon similaire la survie spécifique liée à la maladie était péjorée par : un ganglion sentinelle métastatique, le sexe masculin, l'épaisseur selon Breslow, et une ulcération. Ces données renforcent le statut du ganglion sentinelle en tant que puissant moyen pour évaluer le stade tumoral ainsi que le pronostic.