805 resultados para Self-Oscillating Or Self-Rotating


Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the human pulp response following direct pulp capping with a current self-etching bonding agent and calcium hydroxide (CH). Methods: Thirty-three sound human premolars had their pulp tissue mechanically exposed. Sterile distilled water was used to control the hemorrhage and exudation from the pulp exposure site. The pulps were capped with Clearfil Liner Bond 2 (CLB-2) or CH and the cavities were filled with a resin composite (Z-100) according to the manufacturer's instructions. After 5, 30 and 120-300 days, the teeth were extracted and processed for microscopic examination. Results: At short-term, CLB-2 elicited a mild to moderate inflammatory pulp response with dilated and congested blood vessels adjacent to pulp exposure site. With time, macrophages and giant cells engulfing globules and particulates of resinous material displaced into the pulp space were observed. This chronic inflammatory pulp response triggered by fragments of bonding agent displaced into the pulp space did not allow pulp repair interfering with the dentin bridging. On the other hand, pulps capped with CH exhibited an initial organization of elongated pulp cells underneath the coagulation necrosis. Pulp repair and complete dentin bridge formation was observed at long-term evaluation. Significance: The present study demonstrated that CH remains the pulp capping agent of choice for mechanically exposed human pulps. CLB-2 did not allow complete connective tissue repair adjacent to the pulp exposure site. Consequently, this bonding agent cannot be recommended for pulp therapy of sound human teeth. © 2001 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In engineering practical systems the excitation source is generally dependent on the system dynamic structure. In this paper we analyze a self-excited oscillating system due to dry friction which interacts with an energy source of limited power supply (non ideal problem). The mechanical system consists of an oscillating system sliding on a moving belt driven by a limited power supply. In the oscillating system considered here, dry friction acts as an excitation mechanism for stick-slip oscillations. The stick-slip chaotic oscillations are investigated because the knowledge of their dynamic characteristics is an important step in system design and control. Many engineering systems present stick-slip chaotic oscillations such as machine tools, oil well drillstrings, car brakes and others.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In this work, the dynamic behavior of self-synchronization and synchronization through mechanical interactions between the nonlinear self-excited oscillating system and two non-ideal sources are examined by numerical simulations. The physical model of the system vibrating consists of a non-linear spring of Duffing type and a nonlinear damping described by Rayleigh's term. This system is additional forced by two unbalanced identical direct current motors with limited power (non-ideal excitations). The present work mathematically implements the parametric excitation described by two periodically changing stiffness of Mathieu type that are switched on/off. Copyright © 2005 by ASME.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of dentin surface treatments on the tensile bond strength (TBS) of the self-etching primer Clearfil SE Bond (CSE) and the one-step self-etching One-Up Bond F (OUB). The exposed flat dentin surfaces of twenty-four sound third molars were prepared with diamond bur at high-speed, carbide bur at low-speed or wet ground with #600 grit SiC paper. The adhesive systems were applied to the dentin surfaces and light-cured according to the manufacturers' instructions. A 6-mm high composite crown was incrementally built-up and each increment was light-cured for 40 seconds. After being stored in water (37°C/24 h), the samples were serially sectioned parallel to the long axis, forming beams (n = 20) with a cross-sectional area of approximately 0.8 mm 2. The specimens were tested in a Universal Testing Machine at 0.5 mm/min. The cross-sectional area was measured and the results (MPa) were analyzed by two-way ANOVA and Tukey Test (p < 0.05). Overall, the groups treated with CSE exhibited the highest TBS for all surface treatments. Dentin surfaces prepared with carbide bur at low speed reduced TBS in the CSE group; however, OUB was not affected by surface treatments. The effect of surface abrasive methods on TBS was material-dependent.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

PURPOSE: To investigate the penetration (tags) of adhesive materials into enamel etched with phosphoric acid or treated with a self-etching adhesive, before application of a pit-and-fissure sealant. MATERIALS AND METHODS: The sample comprised six study groups with six specimens each. Before pit-and-fissure sealing with the materials Clinpro SealantTM (Groups I and II), Vitro Seal ALPHA (Groups III and IV) and Fuji II LC (Groups V and VI), the teeth in Groups I, III, and V were etched with 35% phosphoric acid for 30 seconds. Teeth in Groups II, IV, and VI received application of the self-etching adhesive Adper Prompt L-Pop. The treated teeth were sectioned buccolingually, ground to 100-microm thickness, decalcified, and analyzed by conventional light microscopy at 400x magnification. RESULTS: The teeth etched with phosphoric acid exhibited significantly greater penetration than specimens treated with self-etching adhesive. CLINICAL SIGNIFICANCE: When compared with enamel treated with a self-etching adhesive, the penetration (tags) of adhesive materials into enamel was greater when applied on enamel etched with phosphoric acid.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This study subjected two self-adhesive resin cements and two conventional resin cements to dry and aging conditions, to compare their microtensile bond strengths (MTBS) to dentin. Using four different luting systems (n = 10), 40 composite resin blocks (each 5x5x4 mm) were cemented to flat human crown dentin surfaces. The specimens were stored in water for 24 hours (37°C), at which point each specimen was sectioned along two axes to obtain beams that were divided randomly into two groups: dry samples, which were tested immediately, and samples that were subjected to accelerated aging conditions (12, 000 thermocycles followed by storage for 150 days). The μTBS results were affected significantly by the luting system used (P < 40001). Only the μTBS of Rely-X Unicem was reduced significantly after aging; the μTBS remained stable or increased for the other self-adhesive resin cement and the two conventional cements.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the correlation between the hybrid layer thickness, resin tag length and resin bond strength of a self-etching adhesive system to sound dentin tissue in vivo. After performing restorative procedures and tooth extractions, ten specimens were sectioned in a mesiodistal direction. One dental section was used for light microscope analysis, in which both the resin tag length and hybrid layer thickness were measured, while the other section was analyzed using a microtensile test (0.5 mm/min). The fractured surface of the latter section was characterized using a stereoscopic magnifying glass (40x magnifcation). The results were subject to statistical analysis using the Pearson Correlation Test (a = 0.05). The hybrid layer thickness, resin tag length and resin bond strength mean values were 2.19 microm (0.34), 4.34 microm (0.28) and 9.73 MPa (5,55), respectively. In addition, correlation tests between the resin tag length and the resin bond strength (r=0.014) and also between the hybrid layer thickness and bond strength (r=0.43), showed no statistically significant correlation. The microtensile bond strength of Adper Prompt L Pop self-etching adhesive system does not depend on hybrid layer thickness or resin tag length.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We show that self-localized ground states can be created in the spin-balanced gas of fermions with repulsion between the spin components, whose strength grows from the center to periphery, in combination with the harmonic-oscillator (HO) trapping potential acting in one or two transverse directions. We also consider the ground state in the noninteracting Fermi gas under the action of the spatially growing tightness of the one- or two-dimensional (1D or 2D) HO confinement. These settings are considered in the framework of the Thomas-Fermi-von Weizsäcker (TF-vW) density functional. It is found that the vW correction to the simple TF approximation (the gradient term) is nearly negligible in all situations. The properties of the ground state under the action of the 2D and 1D HO confinement with the tightness growing in the transverse directions are investigated too for the Bose-Einstein condensate with the self-repulsive nonlinearity. © 2013 American Physical Society.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Green chemistry is an innovative way to approach the synthesis of metallic nanostructures employing eco-friendly substances (natural compounds) acting as reducing agents. Usually, slow kinetics are expected due to, use of microbiological materials. In this report we study composites of natural rubber (NR) membranes fabricated using latex from Hevea brasiliensis trees (RRIM 600) that works as reducing agent for the synthesis of gold nanoparticles. A straight and clean method is presented, to produce gold nanoparticles (AuNP) in a flexible substrate or in solution, without the use of chemical reducing reagents, and at the same time providing good size's homogeneity, reproducibility, and stability of the composites. Copyright © 2013 Flávio C. Cabrera et al.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objetivo Investigar a associação entre disfunção temporomandibular (DTM) dolorosa, auto-relato de zumbido e níveis de depressão. Método A amostra foi composta por 224 indivíduos com idades de 18 a 76 anos. O Research Diagnostic Criteria for Temporomandibular Disorders , eixo I, foi usado para classificar a DTM e o eixo II para obtenção do auto-relato de zumbido e dos níveis de depressão. Para a análise dos dados, foi aplicado o teste odds ratio (OR) com intervalo de confiança (IC) de 95%. Resultado Somente a presença de DTM dolorosa estava significativamente associada aos níveis de depressão moderado/severo (OR=9,3, 95%; IC: 3,44-25,11). A presença concomitante de DTM dolorosa e auto-relato de zumbido aumentaram a magnitude da associação com os níveis de depressão moderado/severo (OR=16,3; 95% IC: 6,58-40,51). Conclusão Disfunção temporomandibular dolorosa, altos níveis de depressão e auto-relato de zumbido estão fortemente associados. Entretanto, o desenho do estudo não permite estabelecer uma relação causal entre essas três entidades.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Our conception of education is that it is the responsible action whereby man becomes human, trains and faces the challenges that life and the world present, as man enters a larger, shared cultural tradition and thus joins the world. However such sharing implies that we must not just rely on tradition, but remain open to new ideas. It is essential for schooling to preserve a field where the art of living intersects with the world for which future generations are being prepared. It is in this field of intersection that this essay seeks to discuss Michel Foucault's thought, care of the self and the role played by others in the acquisition of ethical attitudes pertaining to one's conduct in life. Through reconstructing Foucault's ideas, we elaborate on the hypothesis that, before morally shaping students, teaching them values, or aiding in their skill acquisition in the sense prevailing in schooling today, it is important to understand the notion of care of the self (and how the notion implies interaction with others for effective care of the self). Care of the self is vital for thoroughly understanding the relationships between ethics and education in school. We particularly examine how Foucault's ideas and his analysis of the teacher's role in shaping the student's life conduct can help educators rethink pedagogical action in an ethical sense and find within it a certain openness to the formation of attitudes in educators and students

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This study evaluated the effect on micro-tensile bond strength (mu-TBS) of laser irradiation of etched/unetched dentin through an uncured self-etching adhesive. Dentinal surfaces were treated with Clearfil SE Bond Adhesive (CSE) either according to the manufacturer's instructions (CSE) or without applying the primer (CSE/NP). The dentin was irradiated through the uncured adhesive, using an Nd: YAG laser at 0.75 or 1 W power settings. The adhesive was cured, composite crowns were built up, and the teeth were sectioned into beams (0.49 mm(2)) to be stressed under tension. Data were analyzed using one-way ANOVA and Tukey statistics (alpha = 5%). Dentin of the fractured specimens and the interfaces of untested beams were observed under scanning electron microscopy (SEM). The results showed that non-etched irradiated surfaces presented higher mu-TBS than etched and irradiated surfaces (p < 0.05). Laser irradiation alone did not lead to differences in mu-TBS (p > 0.05). SEM showed solidification globules on the surfaces of the specimens. The interfaces were similar on irradiated and non-irradiated surfaces. Laser irradiation of dentin through the uncured adhesive did not lead to higher mu-TBS when compared to the suggested manufacturer's technique. However, this treatment brought benefits when performed on unetched dentin, since bond strengths were higher when compared to etched dentin.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the two-year clinical performance of Class III, IV, and V composite restorations using a two-step etch-and-rinse adhesive system (2-ERA) and three one-step self-etching adhesive systems (1-SEAs).Material and Methods: Two hundred Class III, IV, and V composite restorations were placed into 50 patients. Each patient received four composite restorations (Amaris, Voco), and these restorations were bonded with one of three 1-SEAs (Futurabond M, Voco; Clearfil S3 Bond, Kuraray; and Optibond All-in-One, Kerr) or one 2-ERA (Adper Single Bond 2/3M ESPE). The four adhesive systems were evaluated at baseline and after 24 months using the following criteria: restoration retention, marginal integrity, marginal discoloration, caries occurrence, postoperative sensitivity and preservation of tooth vitality. After two years, 162 restorations were evaluated in 41 patients. Data were analyzed using the chi(2) test (p<0.05).Results: There were no statistically significant differences between the 2-ERA and the 1-SEAs regarding the evaluated parameters (p>0.05).Conclusion: The 1-SEAs showed good clinical performance at the end of 24 months.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the influence of Nd:YAG laser on the shear bond strength to enamel and dentin of total and self-etch adhesives when the laser was applied over the adhesives, before they were photopolymerized, in an attempt to create a new bonding layer by dentin-adhesive melting.Material and Methods: One-hundred twenty bovine incisors were ground to obtain flat surfaces. Specimens were divided into two substrate groups (n=60): substrate E (enamel) and substrate D (dentin). Each substrate group was subdivided into four groups (n=15), according to the surface treatment accomplished: X (Xeno III self-etching adhesive, control), XL (Xeno III + laser Nd:YAG irradiation at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental), S (acid etching + Single Bond conventional adhesive, Control), and SL (acid etching + Single Bond + laser Nd:YAG at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental). The bonding area was delimited with 3-mm-diameter adhesive tape for the bonding procedures. Cylinders of composite were fabricated on the bonding area using a Teflon matrix. The teeth were stored in water at 37 degrees C/48 h and submitted to shear testing at a crosshead speed of 0.5 mm/min in a universal testing machine. Results were analyzed with three-way analysis of variance (ANOVA; substrate, adhesive, and treatment) and Tukey tests (alpha=0.05). ANOVA revealed significant differences for the substrate, adhesive system, and type of treatment: lased or unlased (p<0.05). The mean shear bond strength values (MPa) for the enamel groups were X=20.2 +/- 5.61, XL=23.6 +/- 4.92, S=20.8 +/- 4.55, SL=22.1 +/- 5.14 and for the dentin groups were X=14.1 +/- 7.51, XL=22.2 +/- 6.45, S=11.2 +/- 5.77, SL=15.9 +/- 3.61. For dentin, Xeno III self-etch adhesive showed significantly higher shear bond strength compared with Single Bond total-etch adhesive; Nd:YAG laser irradiation showed significantly higher shear bond strength compared with control (unlased).Conclusion: Nd:YAG laser application prior to photopolymerization of adhesive systems significantly increased the bond strength to dentin.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objective: To evaluate the velocity of canine retraction, anchorage loss and changes on canine and first molar inclinations using self-ligating and conventional brackets.Materials and Methods: Twenty-five adults with Class I malocclusion and a treatment plan involving extractions of four first premolars were selected for this randomized split-mouth control trial. Patients had either conventional or self-ligating brackets bonded to maxillary canines randomly. Retraction was accomplished using 100-g nickel-titanium closed coil springs, which were reactivated every 4 weeks. Oblique radiographs were taken before and after canine retraction was completed, and the cephalograms were superimposed on stable structures of the maxilla. Cephalometric points were digitized twice by a blinded operator for error control, and the following landmarks were collected: canine cusp and apex horizontal changes, molar cusp and apex horizontal changes, and angulation changes in canines and molars. The blinded data, which were normally distributed, were analyzed through paired t-tests for group differences.Results: No differences were found between the two groups for all variables tested.Conclusions: Both brackets showed the same velocity of canine retraction and loss of anteroposterior anchorage of the molars. No changes were found between brackets regarding the inclination of canines and first molars.