990 resultados para SCORE TEST
Resumo:
AbstractBackground:Myocardial perfusion scintigraphy (MPS) in patients not reaching 85% of the maximum predicted heart rate (MPHR) has reduced sensitivity.Objectives:In an attempt to maintain diagnostic sensitivity without losing functional exercise data, a new exercise and dipyridamole combined protocol (EDCP) was developed. Our aim was to evaluate the feasibility and safety of this protocol and to compare its diagnostic sensitivity against standard exercise and dipyridamole protocols.Methods:In patients not reaching a sufficient exercise (SE) test and with no contraindications, 0.56 mg/kg of dipyridamole were IV administered over 1 minute simultaneously with exercise, followed by 99mTc-MIBI injection.Results:Of 155 patients, 41 had MPS with EDCP, 47 had a SE test (≥ 85% MPHR) and 67 underwent the dipyridamole alone test (DIP). They all underwent coronary angiography within 3 months. The three stress methods for diagnosis of coronary lesions had their sensitivity compared. For stenosis ≥ 70%, EDCP yielded 97% sensitivity, SE 90% and DIP 95% (p = 0.43). For lesions ≥ 50%, the sensitivities were 94%, 88% and 95%, respectively (p = 0.35). Side effects of EDCP were present in only 12% of the patients, significantly less than with DIP (p < 0.001).Conclusions:The proposed combined protocol is a valid and safe method that yields adequate diagnostic sensitivity, keeping exercise prognostic information in patients unable to reach target heart rate, with fewer side effects than the DIP.
Resumo:
AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.
Resumo:
AbstractBackground:The relationship between psychiatric illness and heart disease has been frequently discussed in the literature. The aim of the present study was to investigate the relationship between anxiety, depression and overall psychological distress, and coronary slow flow (CSF).Methods:In total, 44 patients with CSF and a control group of 50 patients with normal coronary arteries (NCA) were prospectively recruited. Clinical data, admission laboratory parameters, and echocardiographic and angiographic characteristics were recorded. Symptom Checklist 90 Revised (SCL-90-R), Beck Depression Inventory (BDI), and Beck Anxiety Inventory (BAI) scales were administered to each patient.Results:The groups were comparable with respect to age, sex, and atherosclerotic risk factors. In the CSF group, BAI score, BDI score, and general symptom index were significantly higher than controls (13 [18.7] vs. 7.5 [7], p = 0.01; 11 [14.7] vs. 6.5 [7], p = 0.01; 1.76 [0.81] vs. 1.1[0.24], p = 0.01; respectively). Patients with CSF in more than one vessel had the highest test scores. In univariate correlation analysis, mean thrombolysis in myocardial infarction (TIMI) frame counts were positively correlated with BAI (r = 0.56, p = 0.01), BDI (r = 0.47, p = 0.01), and general symptom index (r = 0.65, p = 0.01). The psychiatric tests were not correlated with risk factors for atherosclerosis.Conclusion:Our study revealed higher rates of depression, anxiety, and overall psychological distress in patients with CSF. This conclusion warrants further studies.
Resumo:
AbstractBackground:Risk scores for cardiac surgery cannot continue to be neglected.Objective:To assess the performance of “Age, Creatinine and Ejection Fraction Score” (ACEF Score) to predict mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery, and to compare it to other scores.Methods:A prospective cohort study was carried out with the database of a Brazilian tertiary care center. A total of 2,565 patients submitted to elective surgeries between May 2007 and July 2009 were assessed. For a more detailed analysis, the ACEF Score performance was compared to the InsCor’s and EuroSCORE’s performance through correlation, calibration and discrimination tests.Results:Patients were stratified into mild, moderate and severe for all models. Calibration was inadequate for ACEF Score (p = 0.046) and adequate for InsCor (p = 0.460) and EuroSCORE (p = 0.750). As for discrimination, the area under the ROC curve was questionable for the ACEF Score (0.625) and adequate for InsCor (0.744) and EuroSCORE (0.763).Conclusion:Although simple to use and practical, the ACEF Score, unlike InsCor and EuroSCORE, was not accurate for predicting mortality in patients submitted to elective coronary artery bypass graft and/or heart valve surgery in a Brazilian tertiary care center. (Arq Bras Cardiol. 2015; [online].ahead print, PP.0-0)
Frequency of Cardiovascular Involvement in Familial Amyloidotic Polyneuropathy in Brazilian Patients
Resumo:
Background:Familial amyloidotic polyneuropathy (FAP) is a rare disease diagnosed in Brazil and worldwide. The frequency of cardiovascular involvement in Brazilian FAP patients is unknown.Objective:Detect the frequency of cardiovascular involvement and correlate the cardiovascular findings with the modified polyneuropathy disability (PND) score.Methods:In a national reference center, 51 patients were evaluated with clinical examination, electrocardiography (ECG), echocardiography (ECHO), and 24-hour Holter. Patients were classified according to the modified PND score and divided into groups: PND 0, PND I, PND II, and PND > II (which included PND IIIa, IIIb, and IV). We chose the classification tree as the statistical method to analyze the association between findings in cardiac tests with the neurological classification (PND).Results:ECG abnormalities were present in almost 2/3 of the FAP patients, whereas ECHO abnormalities occurred in around 1/3 of them. All patients with abnormal ECHO also had abnormal ECG, but the opposite did not apply. The classification tree identified ECG and ECHO as relevant variables (p < 0.001 and p = 0.08, respectively). The probability of a patient to be allocated to the PND 0 group when having a normal ECG was over 80%. When both ECG and ECHO were abnormal, this probability was null.Conclusions:Brazilian patients with FAP have frequent ECG abnormalities. ECG is an appropriate test to discriminate asymptomatic carriers of the mutation from those who develop the disease, whereas ECHO contributes to this discrimination.
Resumo:
Abstract Background: The Walking Estimated-Limitation Calculated by History (WELCH) questionnaire has been proposed to evaluate walking impairment in patients with intermittent claudication (IC), presenting satisfactory psychometric properties. However, a Brazilian Portuguese version of the questionnaire is unavailable, limiting its application in Brazilian patients. Objective: To analyze the psychometric properties of a translated Brazilian Portuguese version of the WELCH in Brazilian patients with IC. Methods: Eighty-four patients with IC participated in the study. After translation and back-translation, carried out by two independent translators, the concurrent validity of the WELCH was analyzed by correlating the questionnaire scores with the walking capacity assessed with the Gardner treadmill test. To determine the reliability of the WELCH, internal consistency and test–retest reliability with a seven-day interval between the two questionnaire applications were calculated. Results: There were significant correlations between the WELCH score and the claudication onset distance (r = 0.64, p = 0.01) and total walking distance (r = 0.61, p = 0.01). The internal consistency was 0.84 and the intraclass correlation coefficient between questionnaire evaluations was 0.84. There were no differences in WELCH scores between the two questionnaire applications. Conclusion: The Brazilian Portuguese version of the WELCH presents adequate validity and reliability indicators, which support its application to Brazilian patients with IC.
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2009
Resumo:
Abstract Background: Studies have shown the impact of atrial fibrillation (AF) on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1), which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2), which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36) to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC). Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40) had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.
Resumo:
Abstract Background: GRACE risk score (GS) is a scoring system which has a prognostic significance in patients with non-ST segment elevation myocardial infarction (non-STEMI). Objective: The present study aimed to determine whether end-systolic or end-diastolic epicardial fat thickness (EFT) is more closely associated with high-risk non-STEMI patients according to the GS. Methods: We evaluated 207 patients who had non-STEMI beginning from October 2012 to February 2013, and 162 of them were included in the study (115 males, mean age: 66.6 ± 12.8 years). End-systolic and end-diastolic EFTs were measured with echocardiographic methods. Patients with high in-hospital GS were categorized as the H-GS group (in hospital GS > 140), while other patients were categorized as the low-to-moderate risk group (LM-GS). Results: Systolic and diastolic blood pressures of H-GS patients were lower than those of LM-GS patients, and the average heart rate was higher in this group. End-systolic EFT and end-diastolic EFT were significantly higher in the H-GS group. The echocardiographic assessment of right and left ventricles showed significantly decreased ejection fraction in both ventricles in the H-GS group. The highest correlation was found between GS and end-diastolic EFT (r = 0.438). Conclusion: End-systolic and end-diastolic EFTs were found to be increased in the H-GS group. However, end-diastolic EFT and GS had better correlation than end-systolic EFT and GS.
Resumo:
Abstract Background: Recent studies have shown changes in cardiac autonomic control of obese preadolescents. Objective: To assess the heart rate responses and cardiac autonomic modulation of obese preadolescents during constant expiratory effort. Methods: This study assessed 10 obese and 10 non-obese preadolescents aged 9 to 12 years. The body mass index of the obese group was between the 95th and 97th percentiles of the CDC National Center for Health Statistics growth charts, while that of the non-obese group, between the 5th and 85th percentiles. Initially, they underwent anthropometric and clinical assessment, and their maximum expiratory pressures were obtained. Then, the preadolescents underwent a constant expiratory effort of 70% of their maximum expiratory pressure for 20 seconds, with heart rate measurement 5 minutes before, during and 5 minutes after it. Heart rate variability (HRV) and heart rate values were analyzed by use of a software. Results: The HRV did not differ when compared before and after the constant expiratory effort intra- and intergroup. The heart rate values differed (p < 0.05) during the effort, being the total variation in non-obese preadolescents of 18.5 ± 1.5 bpm, and in obese, of 12.2 ± 1.3 bpm. Conclusion: The cardiac autonomic modulation did not differ between the groups when comparing before and after the constant expiratory effort. However, the obese group showed lower cardiovascular response to baroreceptor stimuli during the effort, suggesting lower autonomic baroreflex sensitivity.
Resumo:
Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h), 2 (TnT2h), 5 (TnT5h), and 8 hours (TnT8h) after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h). After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.
Resumo:
Wireless mesh networks present an attractive communication solution for various research and industrial projects. However, in many cases, the appropriate preliminary calculations which allow predicting the network behavior have to be made before the actual deployment. For such purposes, network simulation environments emulating the real network operation are often used. Within this paper, a behavior comparison of real wireless mesh network (based on 802.11s amendment) and the simulated one has been performed. The main objective of this work is to measure performance parameters of a real 802.11s wireless mesh network (average UDP throughput and average one-way delay) and compare the derived results with characteristics of a simulated wireless mesh network created with the NS-3 network simulation tool. Then, the results from both networks are compared and the corresponding conclusion is made. The corresponding results were derived from simulation model and real-worldtest-bed, showing that the behavior of both networks is similar. It confirms that the NS-3 simulation model is accurate and can be used in further research studies.
Resumo:
Das Prozessleitsystem PCS 7 beinhaltet softwaretechnische Lösungen für alle Hierarchieebenen der industriellen Automatisierung von der Unternehmensleitebene bis zur Anlagenfeldebene. Mit der Simulationssoftware WinMOD können Komponenten,Signale und Prozesse einer Industrieanlage nachgebildet werden. Zudem bietet WinMOD Schnittstellenlösungen für gängige Speicherprogrammierbare Steuerungen und eignet sich somit für den Factory Acceptance Test (FAT) von Prozessleitsystemen. Die FATs sollen sich hauptsächlich auf die Überprüfung von Signaladressierungen und von Ursache und Wirkung konzentrieren. Im Rahmen der vorliegenden Arbeit wurden ausgewählte PCS 7–Projekte untersucht und auf deren Grundlage Aussagen getroffen wie zukünftig Simulationen effektiv erstellt werden können. Hierzu wurden mithilfe von WinMOD Simulationsmodule angelegt - welche reale Komponenten des Anlagenfeldes ersetzen – , ihr Aufbau beschrieben und in einer Bibliothek zusammengefasst. Im Anschluss wird auf die Verwendung der Bibliothek für verschiedene Anwendungsfälle eingegangen und eine Lösung präsentiert, welche das Erstellen einer Simulation für spezifische Projekte optimiert. Das Ergebnis zeigt auf, dass WinMOD sowohl neue Möglichkeiten der Durchführung für einen FAT liefert, wobei die Simulationserstellung nur einen geringen Mehraufwand bedeutet und sich die Durchführung der Simulation ergonomischer und kürzer gestaltet.