956 resultados para SALIVARY FLOW-RATE
Resumo:
A sensitive, precise, and specific high-performance liquid chromatographic (HPLC) method was developed for the assay of gatifloxacin (GATX) in raw material and tablets. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was carried out by reversed-phase chromatography on a C18 absorbosphere column (250 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of acetic acid 50/o--acetonitrile-methanol (70 + 15 + 15, v/v/v) pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 287 nm. The calibration graph for GATX was linear from 4.0 to 14.0 mu g/mL. The interday and intraday precisions (relative standard deviation) were less than 1.05%.
Resumo:
A sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of 1% acetic acid-acetonitrile-methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanol-water (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 mu g/mL. The values for interday and intraday precision (relative standard deviation) were < 1 %. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In asthmatic, the lung hyperinflation leaves the inspiratory muscle at a suboptimal position in length-tension relationship, reducing the capacity of to generate tension. The increase in transversal section area of the inspiratory muscles could reverse or delay the deterioration of inspiratory muscle function. Objective: To evaluate the evidence for the efficacy of inspiratory muscle training (IMT) with an external resistive device in patients with asthma. Methods: A systematic review with meta-analysis was carried out. The sources researched were the Cochrane Airways Group Specialised Register of trials, Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 11 of 12, 2012), MEDLINE, EMBASE, PsycINFO, CINAHL, AMED, ClinicalTrials.gov and reference lists of articles. All databases were searched from their inception up to November 2012 and there was no restriction on the language of publication. Randomised controlled trials that involved the use of an external inspiratory muscle training device versus a control (sham or no inspiratory training device) were considered for inclusion. Two reviewers independently selected articles for inclusion, evaluated risk of bias in studies and extracted data. Results: A total of five studies involving 113 asthmatic patients were included. Three clinical trials were produced by the same group. The included studies showed a significant increase in maximal inspiratory pressure (MD 13.34 cmH2O, 95% CI 4.70 to 21.98), although the confidence intervals were wide. There was no statistically significant difference between the IMT group and the control group for maximal expiratory pressure, peak expiratory flow rate, forced expiratory volume in one second, forced vital capacity, sensation of dyspnea and use of beta2-agonist. There were no studies describing exacerbation events that required a course of oral and inhaled corticosteroids or emergency department visits, inspiratory muscle endurance, hospital admissions and days of work or school. Conclusions: There is no conclusive evidence in this review to support or refute inspiratory muscle training for asthma, once the evidence was limited by the small number of studies included, number of participants in them together with the risk of bias. More well conducted randomized controlled trials are needed, such trials should investigate respiratory muscle strength, exacerbation rate, lung function, symptoms, hospital admissions, use of medications and days off work or school. IMT should also be assessed in the context of more severe asthma
Resumo:
The purpose of this work is to explain the concept of cutting fluids reasonable usage through the fluid minimum quantity in grinding processes. on that purpose, the development of a new nozzle and an own and adequate methodology should be required in order to obtain good results and compare them to the conventional methods. The analysis of the grinding wheel/cutting fluid performance was accomplished from the following input parameters: flow rate variation by nozzle diameter changes (three diameters values: 3mm, 4mm and 5mm), besides the conventional round nozzle already within the machine. Integral oil and a synthetic emulsion were used as cutting fluids and a conventional grinding wheel was employed. The workpieces were made of steel VC 131, tempered and quenched with 60HRc. Thus, as the flow rate and the nozzle diameter changes, keeping steady fluid jet velocity (equal to cutting velocity), attempted to find the best machining conditions, with the purpose to obtain a decrease on the cutting fluid volume, taking into consideration the analysis of the process output variables such as cutting strength, cutting specific energy, grinding wheel wear and surface roughness. It was verified that the 3mm diameter optimized nozzle and the integral oil, in general, was the best combination among all proposed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Atualmente a preocupação ambiental está fazendo com que as empresas busquem diminuir os impactos ambientais por elas causados, ao mesmo tempo em que melhoram a qualidade do produto e processos de fabricação. Logo, muitas pesquisas estão sendo desenvolvidas na área de usinagem para se analisar o real dano ao meio ambiente quando usados diferentes métodos de lubri-refrigeração. Este trabalho teve como objetivo analisar a qualidade da peça produzida e o desgaste do ferramental de corte de uma retificadora plana ao se usinar cerâmica de alumina com dois métodos distintos de aplicação de fluido de corte: método convencional com vazão de 458,3 mL/h e o método da mínima quantidade de lubrificação (MQL) com 100 mL/h. A partir dos resultados obtidos pode-se constatar que para os mesmos parâmetros de usinagem a técnica do MQL utilizou uma quantidade muito menor de fluido e garantiu bons resultados de desgaste diametral do rebolo. No entanto, a qualidade da peça foi bem pior para o método do MQL em relação a técnica de refrigeração convencional. Estes resultados mostraram que se utilizando formas alternativas de lubrificação para reduzir o uso do fluido de corte, são possíveis dependendo de quais fatores são mais importantes para o processo que se deseja. Nesse sentido, se o método do MQL fosse adotado pelas empresas dependentes da retificação, certamente iria trazer, de um lado, benefícios quanto a problemas de descarte e reciclagem de fluido de corte, mas por outro lado, levaria a uma menor qualidade superficial das peças.
Resumo:
The effects of combustion driven acoustic oscillations in carbon monoxide and nitrogen oxides emission rates of a combustor operated with liquefied petroleum gas (LPG) were investigated. Because the fuel does not contain nitrogen, tests were also conducted with ammonia injected in the fuel, in order to study the formation of fuel NOx. The main conclusions were: (a) the pulsating combustion process is more efficient than the non-pulsating one and (b) the pulsating combustion process generates higher rates of NOx, with and without ammonia injection, as shown by CO and NO concentrations as function of the O-2 concentration. An increase in the LPG flow rate, keeping constant the air to fuel ratio, increased the acoustic pressure amplitude and the frequency of oscillation. The injection of ammonia had no influence on either pressure amplitude or frequency. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
O presente trabalho objetivou a avaliação da remoção de matéria orgânica carbonácea e nitrogenada, bem como a determinação do fluxo crítico, em biorreator de membranas, com zona pré-anóxica, tratando águas residuárias industriais da produção de aminoácidos. O reator foi operado sob carga orgânica volumétrica de 1,91 kg.DQO.m-3.d-1 e 0,18 kg.NTK.m-3.d-1; a recirculação do reator aeróbio para o reator anóxico foi de quatro vezes a vazão afluente. O reator apresentou médias de remoção de DQO, NTK e NT de 97, 98 e 92%, respectivamente. O sistema de ultrafiltração foi testado em vários fluxos entre 25 e 37 L.m-2.h-1 e determinou-se o fluxo crítico de 28 L.m-2.h-1 quando operado com 11,4 g.L-1 de SST e 35 dias de tempo de retenção celular. Os resultados mostraram que houve viabilidade técnica no uso de biorreator de membranas para remoção de matéria orgânica de águas residuárias industriais da produção de aminoácidos.
Resumo:
A procedure for calculation of refrigerant mass flow rate is implemented in the distributed numerical model to simulate the flow in finned-tube coil dry-expansion evaporators, usually found in refrigeration and air-conditioning systems. Two-phase refrigerant flow inside the tubes is assumed to be one-dimensional, unsteady, and homogeneous. In themodel the effects of refrigerant pressure drop and the moisture condensation from the air flowing over the external surface of the tubes are considered. The results obtained are the distributions of refrigerant velocity, temperature and void fraction, tube-wall temperature, air temperature, and absolute humidity. The finite volume method is used to discretize the governing equations. Additionally, given the operation conditions and the geometric parameters, the model allows the calculation of the refrigerant mass flow rate. The value of mass flow rate is computed using the process of parameter estimation with the minimization method of Levenberg-Marquardt minimization. In order to validate the developed model, the obtained results using HFC-134a as a refrigerant are compared with available data from the literature.